-
Kenwood X1200M - page 1
X1200M CLASS D MONO PO WER AMPLIFIER 7 page 2-7 INSTR UCTION MANU AL AMPLIFICA TEUR MONO CLASSE D 7 page 8-13 MODE D’EMPLOI AMPLIFICADOR DE PO TENCIA CLASE D MONOFÓNICO 7 página 14-19 MANU AL DE INSTR UCCIONES © B64-4197-00/00 (KV) Take the time to read through this instruction manual. Familiarity with installation and operation procedures wil ...
-
Kenwood X1200M - page 2
2 English Sa fety pre cautions W ARNING T o prevent injury or fire, take the following precautions: • M ounting and wiring this product requires sk ills and exper ience. For safety ’ s sake, leave the mounting and wiring work to professionals. • When extending the ignition, batter y, or ground wires, mak e sure to use automotive- grade wires ...
-
Kenwood X1200M - page 3
English 3 Installation Acc essories Part name External V iew Number of Items Self-tapping screws (ø5 × 18 mm) 4 Hexagon Wrench (Large) 1 Hexagon Wrench (Small) 1 T erminal cover (P ower terminal) 1 Installation procedure Since there are large variety of settings and connections possible according to applications, read the instruction manual well ...
-
Kenwood X1200M - page 4
4 English P.CON SPEAKER OUTPUT REMOTE FUSE [ 30A x 3 ] GND BATT. LINE IN LINE OUT L R SPEAKER OUTPUT SPEAKER OUTPUT CAUTION • If sound is not output normally , immediately turn power off and check connections. • Be sure t o tur n the power off befor e changing the setting of any switch. • If the fuse blows, check wir es for shor ts, then repl ...
-
Kenwood X1200M - page 5
English 5 P.CON SPEAKER OUTPUT REMOTE GND BATT. LINE IN LINE OUT L R P.CON SPEAKER OUTPUT REMOTE GND BATT. LINE IN LINE OUT L R P.CON SPEAKER OUTPUT REMOTE GND BATT. LINE IN LINE OUT L R FUSE [ 30A x 3 ] FUSE [ 30A x 3 ] FUSE [ 30A x 3 ] INPUT SENSITIVITY [ V ] 0.2 [ MAX ] 0.3 0.5 1 2 3 4 [ MIN ] 5 LINE OUT FILTER ON OFF INPUT SENSITIVITY [ V ] 0.2 ...
-
Kenwood X1200M - page 6
6 English Controls 1 Fuse (30 A × 3) NOTE If you can’ t find the specified capacit y fuse at your store etc ., consult your Kenwood dealer . 2 Batter y terminal 3 Power control t erminal Controls the unit ON/OFF . NOTE Controls the unit power . Be sure to connect it with all the systems. 4 Ground terminal 5 Speaker output terminals As this unit ...
-
Kenwood X1200M - page 7
English 7 T roubleshooting Guide Specifications Specifications subject to change without notice. CEA-2006 RMS W atts per channel @ 4 ohms, 1 % THD+N ....................................................................................................................................................................... 800 W × 1 Signal to Noise R atio ...
-
Kenwood X1200M - page 8
8 Frençais Précautions de sécurité A VERTISSEMENT Pour éviter toute blessure et/ou incendie, veuillez prendre les précautions suivantes: • Le montage et le câblage de ce produit nécessite des compétences et de l'expérience. Pour des raisons de sécurité, laissez un professionnel effectuer le travail de montage et de câblage. • ...
-
Kenwood X1200M - page 9
Frençais 9 380 mm 320 mm ø 6 286 mm 272 mm Installation Acc essoires Nom de la pièce Vue extérieure Quantité Vis taraudeuses (ø5 × 18 mm) 4 Clé polygonale (grand) 1 Clé polygonale (petite) 1 Cache de bornier (Borne d’alimentation) 1 Procédure d'installation Etant donné que le nombre de réglages et de raccor dements est assez impo ...
-
Kenwood X1200M - page 10
10 Frençais P.CON SPEAKER OUTPUT REMOTE FUSE [ 30A x 3 ] GND BATT. LINE IN LINE OUT L R SPEAKER OUTPUT SPEAKER OUTPUT A TTENTION • En cas d'anomalie, mettr e immédiatement l'appareil hors tension et vérifier tous les raccordements. • V eiller à mettre l'appareil hors tension avant de changer la position des commutateurs. • ...
-
Kenwood X1200M - page 11
Frençais 11 ■ Connexion du câble de la téléc omma nd e (Ac cessoire optionnel) Câble de la télécommande (6,0 m : 19,7 ft) T élécommande A TTENTION • A vant de brancher les câbles de commande à distance, tournez toujours le bouton de réglage d’amplification des basses au maximum vers la gauche. P.CON SPEAKER OUTPUT REMOTE GND BATT. ...
-
Kenwood X1200M - page 12
12 Frençais P.CON SPEAKER OUTPUT REMOTE FUSE [ 30A x 3 ] GND BATT. LINE IN LINE OUT L R THERMAL MANAGEMENT PROTECTION INPUT SENSITIVITY [ V ] ISF FREQUENCY [ Hz ] LPF FREQUENCY [ Hz ] 0.2 [ MAX ] 0.3 0.5 200 LINE OUT FILTER ON OFF 150 100 70 35 40 15 20 25 30 50 1 2 3 4 [ MIN ] 5 Z ? ...
-
Kenwood X1200M - page 13
Frençais 13 Guide de depannage Spécifications Les spécifications sont sujettes à changements sans notification. CEA-2006 RMS (pression acoustique efficace) Watts par canal @ 4 ohms, 1 % THD+N ........................................................................................................... 800 W × 1 T aux signal/bruit (référence : 1 ...
-
Kenwood X1200M - page 14
14 Español Precauciones de seguridad ADVERTENCIA Par a evitar el riesgo de lesiones y/o fuego, observe las siguientes precauciones: • La instalación y cableado de este producto requiere de habilidad y experiencia. Por motivos de segur idad, deja la labor de instalación y montaje en manos de profesionales . • Cuando extienda los cables de la ...
-
Kenwood X1200M - page 15
Español 15 380 mm 320 mm ø 6 286 mm 272 mm Instalación Acc esorios Nombre de pieza Vista e x terior Unidades T ornillo autorroscantes (ø5 × 18 mm) 4 Llave hexagonal (Grande) 1 Llave hexagonal (P equeña) 1 Cubierta de terminales ( T erminal del cable de alimentación) 1 Procedimiento de instalación Como se puede hacer una gran variedad de aju ...
-
Kenwood X1200M - page 16
16 Español P.CON SPEAKER OUTPUT REMOTE FUSE [ 30A x 3 ] GND BATT. LINE IN LINE OUT L R SPEAKER OUTPUT SPEAKER OUTPUT Conexiones Entrada izquierda Entrada derecha Altavoz de subgra ves (I + D) (≥2Ω) Llave hexagonal (Pequeño) Llave hexagonal (Pequeño) Llave hexagonal (Grande) ADVERTENCIA Retire la lla ve de enc endido y desconecte el terminal ...
-
Kenwood X1200M - page 17
Español 17 P.CON SPEAKER OUTPUT REMOTE GND BATT. LINE IN LINE OUT L R P.CON SPEAKER OUTPUT REMOTE GND BATT. LINE IN LINE OUT L R P.CON SPEAKER OUTPUT REMOTE GND BATT. LINE IN LINE OUT L R FUSE [ 30A x 3 ] FUSE [ 30A x 3 ] FUSE [ 30A x 3 ] INPUT SENSITIVITY [ V ] 0.2 [ MAX ] 0.3 0.5 1 2 3 4 [ MIN ] 5 LINE OUT FILTER ON OFF INPUT SENSITIVITY [ V ] 0 ...
-
Kenwood X1200M - page 18
18 Español P.CON SPEAKER OUTPUT REMOTE FUSE [ 30A x 3 ] GND BATT. LINE IN LINE OUT L R THERMAL MANAGEMENT PROTECTION INPUT SENSITIVITY [ V ] ISF FREQUENCY [ Hz ] LPF FREQUENCY [ Hz ] 0.2 [ MAX ] 0.3 0.5 200 LINE OUT FILTER ON OFF 150 100 70 35 40 15 20 25 30 50 1 2 3 4 [ MIN ] 5 Z ...
-
Kenwood X1200M - page 19
Español 19 Guia Sobre Localización De A verias Especificaciones Las especificaciones se encuentran sujetas a cambios sin previo aviso. CEA-2006 Vatios RMS por canal @ 4 ohms, 1 % THD+N ................................................................................................................................................................... ...
-
Kenwood X1200M - page 20
X1200M_K_3Spanish.indd 20 08.10.21 3:56:24 PM ...
Haben Sie eine Frage bezüglich Kenwood X1200M?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Kenwood X1200M nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Kenwood X1200M hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.