Bedienungsanleitung White Rodgers 1F95-1291

16 Seiten 0.91 mb
Download

Zur Seite of 16

Summary
  • White Rodgers 1F95-1291 - page 1

    Model Programming Choices 1F95-1291 7 Day 5/1/1 Day Non-Programmab le www .white-rodgers .com Big Blue Humidity Univ er sal T her mostat with Humidity/Dehumidity Control and Automa tic Heat/Cool Changeo v er Option P ART NO . 37-6914D Replaces 37-6914C 0905 Single Stage, Multi-Stage, Heat Pump Installation and Operating Instructions APPLICA TIONS 1 ...

  • White Rodgers 1F95-1291 - page 2

    2 Remove Old Thermostat Bef ore removing wires from old thermostat, mar k wires f or terminal identifi cation so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the ther mostat base. Forcing or pr ying on the thermostat will cause damage to the unit. 2. Place base ov er hole in w ...

  • White Rodgers 1F95-1291 - page 3

    3 WIRING DIA GRAMS Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single T ransformer Single Stage 1 (SS1) Multi Stage 2 (MS2) System RC RH C Y Y2 W/E W2 G O/B 6 L CLASS II TRANSFORMER HO T 24V AC NEUTRAL 120V AC Call for heat Heat mode-1st stage Heat mode-2nd stage No output 24 volt power f or cooling 24 volt power f or heatin ...

  • White Rodgers 1F95-1291 - page 4

    4 If you ha v e a single stage compressor system see the dia- gram belo w . A relay (customer provided) should be installed as shown in Fig 7 to s witch the fan speed to the ne xt lower speed on a call f or dehumidifi cation from the thermostat. The reduction in air fl o w allows the coil to remo ve more humidity from the air . The rela y should ...

  • White Rodgers 1F95-1291 - page 5

    5 Programming and Confi guration Items 1 Displa ys and "Keypad Loc kout" when in k eypad lock out mode. Displa ys and "T emperature Limit" and "Keypad Lock out" when limited range is activ ated and lock ed. Displa ys only "T emperature Limit" when limited range is activated. 2 Indicates period of day being p ...

  • White Rodgers 1F95-1291 - page 6

    6 INST ALLER/CONFIGURA TION MENU T o enter the menu: Press the Menu touch k ey . Press and hold f or 5 seconds the Installer Confi g touch ke y . This displays menu item #1 in the tab le below . Press to advance to the ne xt menu item or to return to a previous menu item. Press or to change a menu item option. CONFIGURA TION MENU Menu Reference Nu ...

  • White Rodgers 1F95-1291 - page 7

    7 INST ALLER/CONFIGURA TION MENU 1. This control can be confi gured f or : MS2 – Multi-Stage System (2 heat/2 cool) HP1 – Heat Pump with one stage of compressor (2 heat/1 cool) HP2 – Heat Pump with two stage compressor or two compressor system, Gas or Electric backup; (Dual Fuel see menu item 28) (4 heat/2 cool) SS1 – Single Stage System ( ...

  • White Rodgers 1F95-1291 - page 8

    8 12. Select Continuous Backlight – In low lighting condi- tions, displa y backlight improv es the displa y contrast. When C terminal is connected, selecting dL On will tur n the backlight on contin uously . Selecting dL Off will tur n the backlight on momentarily after any k ey is pressed. When C terminal is not powered (batter y only), dL On en ...

  • White Rodgers 1F95-1291 - page 9

    9 when you man ually raise the setting and want to allo w the thermostat to stage based on recent system performance. The F ast Cool feature operates the cooling stages in the same manner as F ast Heat, On or Off when the tempera- ture is lowered belo w the room setting. 27. Select Remote T emperature Sensor – Allows one wired remote temperature ...

  • White Rodgers 1F95-1291 - page 10

    10 cally reduces indoor humidity with a call f or Cooling if humidity is 2% abov e setting. Humidity is set by pressing the HUMIDITY ke y when in the appropriate mode, in this case Cooling , and pressing the or keys to set desired humidity le vel f ollowed by pressing Humidity key again. This dehumidifi cation f eature may use more energy by makin ...

  • White Rodgers 1F95-1291 - page 11

    11 Choose the System Setting (Cool, Off, Heat, Em, A uto) Press the SYSTEM ke y to select: Cool: Thermostat controls only the cooling system. Off: Heating and Cooling systems are off . Heat: Thermostat controls only the heating system. Em: Setting is av ailable only when the thermostat is confi g- ured in HP1 or HP2 mode. A uto: A uto Changeov er ...

  • White Rodgers 1F95-1291 - page 12

    12 PR OGRAMMING Set Current Time and Day 1. Press Menu ke y to enter installer menu. Then press Set Time once to indicate hour & AM or PM designation in clock displa y . 2. Press and hold either the or touch key until y ou reach the correct hour and AM or PM designation. 3. Press Set Time again to displa y minutes only in clock displa y . 4. Pr ...

  • White Rodgers 1F95-1291 - page 13

    13 PR OGRAMMING Planning Y our Program – Important The Heating and Cooling Program schedules belo w allow y ou to pencil in your o wn program times and temperatures . The 1F95-1291 comes confi gured f or 7 day progr amming and can also be confi gured f or 5+1+1 programming (see confi gur a- tion section). F actor y settings are listed on Monda ...

  • White Rodgers 1F95-1291 - page 14

    14 PR OGRAMMING Cooling Program W ake Up (Morning) Fan Leave For W ork (Day) Fan Return Home (Evening) Fan Go T o Bed (Night) Fan MON 6:00 AM 75°F A uto 8:00 AM 83°F A uto 5:00 PM 75°F Auto 10:00 PM 78°F A uto TUE WED THU FRI SA T 6:00 AM 75°F A uto 8:00 AM 83°F A uto 5:00 PM 75°F Auto 10:00 PM 78°F A uto SUN 6:00 AM 75°F A uto 8:00 AM 83? ...

  • White Rodgers 1F95-1291 - page 15

    15 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 f eet). T erminals +, S and - on the terminal block allo w connection of the remote sensor . The thermostat must hav e 24 V AC Common connection to terminal C for the remo ...

  • White Rodgers 1F95-1291 - page 16

    16 www.white-rodgers.com White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. HOMEO WNER HELP LINE: 1-800-284-2925 TR OUBLESHOO TING Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power ...

Produzent White Rodgers Kategorie Thermostat

Dokumente, die wir vom Produzenten des Geräts White Rodgers 1F95-1291 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen White Rodgers
- Bedienungsanleitungen 1F95-1291
- Produktkarten White Rodgers
- Informationsbroschüren
- oder Energieetiketten White Rodgers 1F95-1291
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung White Rodgers 1F95-1291.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen White Rodgers 1F95-1291, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen White Rodgers 1F95-1291. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts White Rodgers 1F95-1291 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts White Rodgers 1F95-1291, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von White Rodgers 1F95-1291 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von White Rodgers 1F95-1291 verständlich ist.

Eine gänzliche Bedienungsanleitung von White Rodgers sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von White Rodgers 1F95-1291 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von White Rodgers 1F95-1291 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich White Rodgers 1F95-1291, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts White Rodgers 1F95-1291 - die uns die ersten Schritte während der Nutzung von White Rodgers 1F95-1291 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit White Rodgers 1F95-1291 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von White Rodgers 1F95-1291 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich White Rodgers 1F95-1291?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit White Rodgers 1F95-1291 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit White Rodgers 1F95-1291 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)