Bedienungsanleitung Konig CMP-BARSCAN30

48 Seiten Betrifft nicht
Download

Zur Seite of 48

Summary
  • Konig CMP-BARSCAN30 - page 1

    CONTENTS Getting Started ----------------------------------------------------------------------- 2 Setup Procedures --------------------------------------------------------------------- 3 Setup Menu------------------------------------------------------------------------------- 4 Setup flow Chart ----------------------------------------------------- ...

  • Konig CMP-BARSCAN30 - page 2

    Getting Started Installing Keyboard Wedge Scanner To install a keyboard wedge scanner, follow the steps listed below: 1) Make sure that the scanner has the correct Y (U)- cable for the system (a PC or terminal) 2) Turn off the power of the system 3) Unplug the keyboard from the system 4) Connect the Y (U)- cable to the system and keyboard 5) Turn o ...

  • Konig CMP-BARSCAN30 - page 3

    Setup Procedures 1) Locate a group that contains the parameters to be changed. 2) Scan the “Enter Group # ” label. The scanner will sound beeps indicate that setup is in progress 3) Scan the label representing the parameter to be changed 4) Scan the “Exit” to end the group currently selected, the scanner will sound beeps. 5) Repeat the proc ...

  • Konig CMP-BARSCAN30 - page 4

    Setup Flow Chart Set All Defaults Show Version ENTER GROUP SELECT ITEMS EXIT 4 ...

  • Konig CMP-BARSCAN30 - page 5

    Group 0: Interface Selection KEYBOARD RS-232 WAND OCIA RS-232 Reserved 2 DTMF Reserved 4 ENTER GROUP EXIT 5 ...

  • Konig CMP-BARSCAN30 - page 6

    Group 1: Device Selection for Keyboard Interface PC/AT, PS/2 50,60,70,80(*) PC/XT PS/2 25, 30 (NEC 9801) (IBM 5550) (PS 55) (NEC N5520) (ACER 7300) (KW1050D/CT-700A/WANG 5120) (WANG 5425) (MAC_SE) (LC-6533) ENTER GROUP EXIT 6 ...

  • Konig CMP-BARSCAN30 - page 7

    Group 1: Device Selection for Keyboard Interface (IBM3196,3197,3476,3477) Reserved Q Reserved R Reserved T IBM3197 IBM 3476 IBM3477 RESERVED 5 Reserved 6 RESERVED 7 Reserved 8 RESERVED 9 ENTER GROUP EXIT 7 ...

  • Konig CMP-BARSCAN30 - page 8

    Group 2: Intercharacter Delay Start Keyboard Setting Scan Enter Group 2 Label -- > Scan Start Keyboard (or RS-232) Setting Label --> Scan two digits labels in "Table-Hex" --> Scan Exit Label Start RS-232 Setting Keyboard Default Value: 05 RS-232 Default Value : 00 ENTER GROUP EXIT 8 ...

  • Konig CMP-BARSCAN30 - page 9

    Group 3: Language for Keyboard Interface U.S. (*) ENGLAND FRANCE GERMANY ITALY BELGIUM SWEDEN/FINLAND SPANISH DENMARK PORTUGAL SWISS NORWAY ENTER GROUP EXIT 9 ...

  • Konig CMP-BARSCAN30 - page 10

    Group 3: Language for Keyboard Interface CANADA HOLLAND POLAND LATIN JAPAN RESERVED 1 RESERVED 2 RESERVED 3 (IBM THINK-PAD FOR JAPAN) (PANASONIC CF-II FOR JAPAN) ENTER GROUP EXIT 10 ...

  • Konig CMP-BARSCAN30 - page 11

    Group 4: Terminator KEYBOARD NONE CR SPACE TAB ESC CTRL-C ESC ENTER GROUP EXIT 11 ...

  • Konig CMP-BARSCAN30 - page 12

    Group 4: Terminator RS-232 NONE CR CR/LF LF SPACE TAB ESC CTRL-C STX..ETX XON.. XOFF EOT ENTER GROUP EXIT 12 ...

  • Konig CMP-BARSCAN30 - page 13

    Group 5: Scan Mode 1: Trigger On/Off 2: Trigger On/Good Read Off (*) 3: Trigger On/Good Read Off/ Delay Timeout = ? 4: Continuous/Trigger Off 5: Continuous/LED Always on 6: Continuous/No Trigger 7: Continuous/Testing 8: Continuous/Trigger Off/ Delay Timeout = ? ENTER GROUP EXIT 13 ...

  • Konig CMP-BARSCAN30 - page 14

    Group 5: Scan Mode FLASH OFF(*) FLASH ON SHORT ZONE LONG ZONE LASER DELAY For Laser Scanner Mode Default Laser Delay Timeout = 60 sec. Scan Enter Group 5 Label Scan Laser Delay --> Refer to the Table-Hex at page 41 and select a value --> Scan Confirm in Table Hex. Scan Exit Label LAG-960TR - Auto Trigger mode AUTO TRIGGER Scan Enter Group 5 L ...

  • Konig CMP-BARSCAN30 - page 15

    Group 6: Preamble and Postamble Preamble Postamble Preamble & Postamble Setting: Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Refer to ASCII Table(page 44), scan two digits in Table-Hex (Page 43) Representing one character, maximum 10 characters can be accepted. --> Scan Confirm Label in Table-Hex (Page 43) Scan Ex ...

  • Konig CMP-BARSCAN30 - page 16

    Group 8: RS-232 Parameters Baud Rate 300 600 1200 2400 4800 9600(*) 19200 38400 Data Bit BIT 7 BIT 8 ENTER GROUP EXIT 16 ...

  • Konig CMP-BARSCAN30 - page 17

    Group 8: RS-232 Parameters Parity : NONE (*) ODD EVEN Handshaking: NONE (*) XON/OFF Scanner Ready Data Ready ACK/NAK ENTER GROUP EXIT 17 ...

  • Konig CMP-BARSCAN30 - page 18

    Group 8: RS-232 Parameters (CK/NAK Response Time CTS Observation Time:) 100 ms 300 ms 500 ms 1 sec. 3 sec (*) 5 sec. 10 sec. 00 ENTER GROUP EXIT 18 ...

  • Konig CMP-BARSCAN30 - page 19

    Group 9: CODE 39 / (CODE 32) Enable (*) Disable Standard (*) Full ASCII Transmit Start/End Character Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) Enable CODE 32 ENTER GROUP EXIT 19 ...

  • Konig CMP-BARSCAN30 - page 20

    Group 9: CODE 39 / (CODE 32) Verify Normal (*) Verify Strick ENTER GROUP EXIT 20 ...

  • Konig CMP-BARSCAN30 - page 21

    Group 10-1: Interleaved 2 OF 5 Disable (*) Enable Transmit Check Character Disable Enable (*) Verify Checksum Disable Enable Length Define Min: 4 Barcode Length Setting Max: 48 Scan Enter Group 10-1 Label --> Scan Length Define Label --> Scan Four Digit Labels in Table Hex (Page 43) --> Scan Confirm Label in Table-Hex --> Scan Exit Labe ...

  • Konig CMP-BARSCAN30 - page 22

    Group 10-2: Industrial 2 OF 5 / IATA Disable (*) Enable Transmit Check Character Disable Enable (*) Verify Checksum Disable Enable Length Define Min: 2 Barcode Length Setting Max: 24 Scan Enter Group 10-2 Label --> Scan Length Define Label --> Scan Four Digit Labels in Table Hex (Page 43) --> Scan Confirm Label in Table-Hex --> Scan Exi ...

  • Konig CMP-BARSCAN30 - page 23

    Enable Group 10-3: Matrix 2 of 5 Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) Length Define Min: 2 Barcode Length Setting Max: 40 Scan Enter Group 10-3 Label --> Scan Length Define Label --> Scan Four Digit Labels in Table Hex (Page 43) --> Scan Confirm Label in Table-Hex --> Scan Exi ...

  • Konig CMP-BARSCAN30 - page 24

    Scan Confirm Label in Table Hex --> Scan Exit Label Group 10-4: CHINA POSTAGE Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) Length Define Min: 2 Barcode Length Setting Max: 40 Scan Enter Group 10-3 Label --> Scan Length Define Label --> Scan Four Digit Labels in Table Hex (Page 43) --> ...

  • Konig CMP-BARSCAN30 - page 25

    Scan Confirm Label in Table Hex --> Scan Exit Label Group 11: CODE 128/(CODE 93)/(CODE 11)/(MSI-PLESSEY) CODE 128 Enable (*) Disable CODE 93 Enable Disable (*) Concatenation Enable Disable (*) ENTER GROUP EXIT 25 ...

  • Konig CMP-BARSCAN30 - page 26

    Note: Options marked by ( ) are only available upon request Group 11: CODE 128/(CODE 93)/(CODE 11)/(MSI-PLESSEY) Enable(*) Disable Number of Check Character One Two (*) Transmit Check Character Enable Disable (*) MSI/PLESSEY Enable (*) Disable ENTER GROUP EXIT 26 ...

  • Konig CMP-BARSCAN30 - page 27

    Note: Options marked by ( ) are only available upon request Group 12: (ISBN/ISSN) Disable (*) Enable ENTER GROUP EXIT 27 ...

  • Konig CMP-BARSCAN30 - page 28

    Note: Options marked by ( ) are only available upon request Group 13: CODABAR / NW7 Enable(*) Disable Transmit Start/End Character Disable (*) Enable Start/End Transmit Type ABCD/ABCD ABCD/TN*E abcd/abcd (*) abcd/tn*e ENTER GROUP EXIT 28 ...

  • Konig CMP-BARSCAN30 - page 29

    Group 14: (Code 4) Enable Disable (*) ENTER GROUP EXIT 29 ...

  • Konig CMP-BARSCAN30 - page 30

    Note: Options marked by ( ) are only available upon request Group 15-1: EAN-13/JAN-13 Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable Truncate Leading Zero Disable (*) Enable ENTER GROUP EXIT 30 ...

  • Konig CMP-BARSCAN30 - page 31

    Check-Digit On (*) Check-Digit Off Group 15-2: UPC-A Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable Truncate Leading Zero Disable (*) Enable ENTER GROUP EXIT 31 ...

  • Konig CMP-BARSCAN30 - page 32

    Group 15-3: EAN-8/JAN-8 Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Disable (*) Enable EAN Convert to EAN-13 Disable (*) Enable ENTER GROUP EXIT 32 ...

  • Konig CMP-BARSCAN30 - page 33

    Group 15-4: UPC-E / UCC EAN/128 Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable UCC/EAN/128 Disable (*) Enable UPC-E Convert to UPC-A ENTER GROUP EXIT 33 ...

  • Konig CMP-BARSCAN30 - page 34

    Disable Enable Group 16: General Parameters Upper Case Lower Case Universal ALT Mode Buzzer Pitch (Default : 16) Buzzer Duration (Default: 04) Buzzer Pitch & Buzzer Duration Setting: Scan Enter Group 16 Label --> Scan Buzzer Pitch or Buzzer Duration Label --> Scan Two Digit Labels in Table-Hex --> Scan Confirm Label in Table-Hex --> ...

  • Konig CMP-BARSCAN30 - page 35

    Turbo (*) Normal Group 17: Code ID Setting CODE 39 INTERLEAVED 2 OF 5 INDUSTRIAL 2 OF 5 MATRIX 2 OF 5 CHINA POSTAGE CODE 128 CODE 93 CODE 11 MSI/PLESSEY CODABAR/NW7 EAN-13/UPC-A EAN-8 UPC-E UPC-A ENTER GROUP EXIT 35 ...

  • Konig CMP-BARSCAN30 - page 36

    Note: Refer to ASCII Table, scan two hexadecimal labels in Table Hex to represent one character Group 18: WAND Type Parameters BAR=LOW BAR=HIGH(*) Scan Speed Lowest Low (*) High Highest Data Format Transmit in Normal Format (*) Transmit in Code 39 Format Transmit in Code 128 Format ENTER GROUP EXIT 36 ...

  • Konig CMP-BARSCAN30 - page 37

    Group 19-1: (Magnetic Parameters) Disable Enable (*) Track Order Track 1/2/3 (*) Track 1/3/2 Track 2/1/3 Track 2/3/1 Track 3/2/1 Track 3/1/2 ENTER GROUP EXIT 37 ...

  • Konig CMP-BARSCAN30 - page 38

    Note: Options marked by ( ) are only available upon request Group 19-1: (Magnetic Parameters) Track Selection Track 1&2&3 any (*) Track 1 only Track 2 only Track 3 only Track 1 and 2 Track 2 and 3 Track 1 and 2 and 3 ISO (*) (JIS-2) ENTER GROUP EXIT 38 ...

  • Konig CMP-BARSCAN30 - page 39

    Note: Options marked by ( ) are only available upon request Group 19-2: (Magnetic Parameters) Start Sentinel: (SS) Tk1 Default : % Tk2 Default Tk3 Default: ; ? End Sentinel: (ES) Tk1&2&3 Default: ? DLE: Tk1 Default : Null Tk2 Default: Null Tk3 Default: Null STX: Tk1&2&3 Default: Null Magnetic Output Data Format: ENTER GROUP EXIT 39 ...

  • Konig CMP-BARSCAN30 - page 40

    STX - Tk1 Start Sentinel - Tk1 Data - End Sentinel - Tk1 - DLE STX - Tk2 Start Sentinel - Tk2 Data - End Sentinel - Tk2 - DLE STX - Tk3 Start Sentinel - Tk3 Data - End Sentinel - Tk3 - DLE Note: Options marked by ( ) are only available upon request Group 20: (Function Key Emulation) Enable Disable (*) Enable Function Key Emulation: Scan Enter Group ...

  • Konig CMP-BARSCAN30 - page 41

    2: To scan a function key barcode label, full CODE 39 must be enabled. Please refer to Full CODE 39 Table to produce the function key barcode label. Full CODE 39 Enable Function Code for PC XT/AT F1 ($A) F7 ($G) F2 ($B) F8 ($H) F3 ($C) F9 ($I) F4 ($D) F10($J) F5 ($F) F11 ($K) F6 ($F) F12 ($L) 41 ...

  • Konig CMP-BARSCAN30 - page 42

    Function Code for PC XT/AT Enter ($M) End ($U) ($B) Tab ($N) PgUp ($V) BS ($O) PgDn ($W) Up ($P) Ins ($X) Down ($Q) Del ($Y) Left ($R) Esc (%A) Right ($S) 42 ...

  • Konig CMP-BARSCAN30 - page 43

    Home ($T) Table-Hex : HEXADECIMAL 0 1 2 3 4 5 6 7 8 9 A B C D 43 ...

  • Konig CMP-BARSCAN30 - page 44

    E F Confirm ASCII TABLE 44 ...

  • Konig CMP-BARSCAN30 - page 45

    Hexadecimal-Decimal Conversion Table 45 ...

  • Konig CMP-BARSCAN30 - page 46

    For Example: Hexadecimal Decimal 56 -> H:5 L:3 83 D5-> H:D L:5 213 PIN ASSIGNMENTS COLOR Function 9 Pin DSUB/AM P (F) 25 PIN DIN(M) 6 PIN DIN (M) 6 PIN MINI DIN (M) Yellow Start of Scan 1 --- 6 6 Orange Signal Data 2 2 2 4 White Led Indicator 3 --- --- --- Blue Trigger 5 5 5 1 Green Power Enable 6 4 4 2 Black GND 7 3 3 5 Red VCC+5V 9 1 1 3 Wa ...

  • Konig CMP-BARSCAN30 - page 47

    PIN ASSIGNMENTS RS-232 Signal Output COLOR FUNCTION 9 PIN DSUB/AMP(F) 25PIN DSUB(F) Black GND 5 7 Brown CTS 7 4 Grey RTS 8 5 Violet RX 3 2 Green TX 2 3 Red VCC+5V 9 25 Note : For PC applications , a cable with DC power jack is required to accept external power input. Keyboard Signal Output COLOR FUNCTION 5 PIN DIN (F) 5 PIN DIN (M) Black GND 4 4 Wh ...

  • Konig CMP-BARSCAN30 - page 48

    48 ...

Produzent Konig Kategorie Barcode readers

Dokumente, die wir vom Produzenten des Geräts Konig CMP-BARSCAN30 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Konig
- Bedienungsanleitungen CMP-BARSCAN30
- Produktkarten Konig
- Informationsbroschüren
- oder Energieetiketten Konig CMP-BARSCAN30
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Konig CMP-BARSCAN30.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Konig CMP-BARSCAN30, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Konig CMP-BARSCAN30. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Konig CMP-BARSCAN30 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Konig CMP-BARSCAN30, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Konig CMP-BARSCAN30 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Konig CMP-BARSCAN30 verständlich ist.

Eine gänzliche Bedienungsanleitung von Konig sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Konig CMP-BARSCAN30 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Konig CMP-BARSCAN30 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Konig CMP-BARSCAN30, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Konig CMP-BARSCAN30 - die uns die ersten Schritte während der Nutzung von Konig CMP-BARSCAN30 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Konig CMP-BARSCAN30 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Konig CMP-BARSCAN30 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Konig CMP-BARSCAN30?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Konig CMP-BARSCAN30 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Konig CMP-BARSCAN30 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)