    R1 P43 Pellet Stove Owners Manual SA VE THESE INSTRUCTIONS. Installation & Operating Manual R1 “Ce manuel est disponible en Français sur demande” SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INST ALL AND USE YOUR NEW ROOM HEA TER. F AILURE TO FOLLOW INSTRUCTIONS MA Y RESUL T IN PROPERTY DAMAGE, BODIL Y INJUR Y , OR EVEN DEA TH. ...

  • Harman Stove Company P43 - page 2

    2 P43 Pellet Stove Harman PP38+/P43 Pellet Stove Label measures: 4-3/8" high X 9-3/4"wide MINIMUM CLEARANCES TO COMBUSTIBLES: SIDEWALL T O STOVE 16" 10" BACKWALL T O STOVE 2" 2" CEILING TO ST OVE TOP 18" 18" STOVE CORNER T O DIAGONAL W ALL 9" 9" PREVENT HOUSE FIRES, OPERA TE WITH VIEWING & ASH D ...

  • Harman Stove Company P43 - page 3

    3 P43 Pellet Stove Safety Information 4 Installation 5 V enting 7 ESP Control 14 Automatic Operation 15 Manual Operation 18 Low Draft V oltage Adjustment 20 Room Sensor 21 Maintenance 22 T rouble Shooting 26 Feeder Parts 27 Specications    28 Options 29 Wiring Diagram 30 Parts List 31 W arranty 32 Ple ase read thi s entir e manual be ...

  • Harman Stove Company P43 - page 4

    4 P43 Pellet Stove DO NOT INST ALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT . DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SER VING ANOTHER APPLIANCE. MOBILE HOME INST ALLA TION SHOULD BE DONE IN ACCORDANCE WITH THE MANUF ACTURED HOME AND SAFETY ST ANDARD (HUD), CFR 3280, P ART 24. CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME F ...

  • Harman Stove Company P43 - page 5

    5 P43 Pellet Stove Assembly and Installation Unpacking The P43 is bolted (1/4 x 1" hex head bolts) to the skid to prevent movement during shipping. T o free the stove from the skid you must remove the hold-down bolts in the rear of the pedestal base. Removing rear cover panels The rear cover panels are secured to the stove with three bolts eac ...

  • Harman Stove Company P43 - page 6

    6 P43 Pellet Stove Installing Place the stove on a noncombustible oor protector that extends a minimum of 6 inches to the front, (mea- sured from the glass) 6 inches to the sides and 1 inch to the rear of the hopper . In some places, it is required that oor protection be installed under any horizon ...

  • Harman Stove Company P43 - page 7

    7 P43 Pellet Stove V enting Requirements for T erminating the V enting W ARNING: V enting terminals must not be recessed into a wall or siding. NOTE: Only approved pellet vent pipe, wall pass- throughs, and re stops should be used when venting through combustible materials. NOTE: Always take into consideration the ef f ...

  • Harman Stove Company P43 - page 8

    8 P43 Pellet Stove V enting A co mb us ti on b lo we r is us ed t o ext ra ct t he combustion gases from the rebox. This causes a negative pressure in the rebox and a positive pres - sure in the venting system as shown in Fig. 7. The longer the vent pipe and more elbows used in the system, th ...

  • Harman Stove Company P43 - page 9

    9 P43 Pellet Stove Outside air ex pipe goes here. Inlet Cover part# 1-10-08542 Flex pipe part# 1-00-08543 (25') Outside Air Here a refourbenetsof outside air: 1. Having air introduced from outside the living area boosts thermal efciency . Because the make up air is not being drawn in through leaky windows ...

  • Harman Stove Company P43 - page 10

    10 P43 Pellet Stove #2 Preferred method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to ve feet high and at lea st thre e i nch es fro m a co mbu sti ble w all . Thi s vertical sec ...

  • Harman Stove Company P43 - page 11

    1 1 P43 Pellet Stove #4 Installing into an existing chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable* you may want to install a liner as in method #7. In some places in the US and Canada it is required that the vent ...

  • Harman Stove Company P43 - page 12

    12 P43 Pellet Stove #6 Installing into an existing replace chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. In some places in the US and Canada it is re- quired that the vent pipe extend all the way to the top of the chimney . The pipe or liner inside th ...

  • Harman Stove Company P43 - page 13

    13 P43 Pellet Stove #8 Installing through the ceiling Through the ceiling vent, follow PLvent manufacturers recommendations when using wall and ceiling pass through. Note: Do not place joints within wall pass-throughs. Fig. 14 PL vent manufacturer's firestop spacer and support (See Page 6 for corner installation clearances) Minimum flue vent c ...

  • Harman Stove Company P43 - page 14

    14 P43 Pellet Stove P43 AUTOMA TIC IGNITION ESP CONTROL Feed adjuster Sets the maximum feed rate T est Runs all motors at full speed for one minut e to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remin d you that you are still in "T est Mode". Igniter ...

  • Harman Stove Company P43 - page 15

    15 P43 Pellet Stove P43 AUTOMA TIC IGNITION/OPERA TION Room T emperature Mode: This setting, see above, will produce a room temperature of 70 degrees with the distribution blower at medium speed. The P43 is a fully automatic stove that features two op era ting mod es ; Stov e T em pera ture Mod e and Roo m T emperature Mode . In Stove T emperature ...

  • Harman Stove Company P43 - page 16

    16 P43 Pellet Stove Stove T emperature Mode In the Stove T emperature Mode and with the igniter toggle switch in the Auto position, the stove will light automa tically and can be adjusted to the desire d setting using the same temperature control dial as is used in the Room T emperature Mode. The heat output and fuel consumption will remain constan ...

  • Harman Stove Company P43 - page 17

    17 P43 Pellet Stove Igniter Switch to"AUTO"(up position) Make sure the unit is plugged into a 120 V AC, 60 HZ electrical source. The power light should be the only light lit. 1. T urn Mode Selector to "OFF". 2. Fill hopper with pellets. 1 3. Clean burn pot with scraper , if necessary . 5 4. If starting after an empty hopper , tu ...

  • Harman Stove Company P43 - page 18

    18 P43 Pellet Stove The P43 Pellet Stove is capable of manual operation. This also allows the operator to manually control operation during an emergency (i.e. igniter failure, when using a 502H battery backup, as opposed to the 512H, or when using certain generators.) The unit can be switched between "AUTO" and "MANUAL" at any t ...

  • Harman Stove Company P43 - page 19

    19 P43 Pellet Stove P43 MANUAL ST ART UP Igniter Switch to"MANUAL" (down position) Make sure the unit is plugged into a 120 V AC, 60 HZ electrical source. The power light should be the only light lit. 1. T urn FEED ADJUSTER to desired feed rate . No. 4 is good for most pellets. 4 2. T urn the MODE SELECTOR to “OFF” and then to the des ...

  • Harman Stove Company P43 - page 20

    20 P43 Pellet Stove These units are pre-tested at the factory with exactly 120 V olts A.C., 60 Hz. They are checked and adjusted for rebox tightness, gasket leakage, motor operation and igniter operation. The P43 is then factory set at a mid -poi nt adju stme nt and in most case s will not need any adj ustm ent s. NOTE : The ...

  • Harman Stove Company P43 - page 21

    21 P43 Pellet Stove The room sensor is a small temperature sensor on the end of a 60" wire. This sensor is installed much like a standard wall thermostat. Because it is so small, it can be hidden along the trim of a door- way or even up the leg of a coffee table. There is a remote room sensor port on the rear of the unit for easy external conn ...

  • Harman Stove Company P43 - page 22

    22 P43 Pellet Stove Removing Ashes: When approximately 1 ton of pellets has been burned, it will be necessary to empty the ash pan. Ash es sh oul d be pla ced in a meta l cont ain er with a tight tting lid. The closed container of ashes should be placed on a noncombustible oor or on the ground, well away from all com - bustible materials, pen ...

  • Harman Stove Company P43 - page 23

    23 P43 Pellet Stove Exposed blower wheel and ue opening, NOTE: ESP probe is visible. Blower cover removed. ESP probe 8. Clean the combustion blower wheel with a brush and a vacuum cleaner . Note: Do not use a household vacuum to clean the stove. W e recommend that you usea shopvacuumthat isequipped witha nedust? ...

  • Harman Stove Company P43 - page 24

    24 P43 Pellet Stove Burn Pot Cleaning and Maintenance 1. Scrape the top holed surface and sides of the burn pot. (Fig 33) It is not neces sary to comple tely remove all material from the burn pot. The excess will be pushed out during the next use. 2. Loosen the (2) wing thumb screws on the lower front angle of the burn pot. (Fig. 34) 3. Li ft of f ...

  • Harman Stove Company P43 - page 25

    25 P43 Pellet Stove P43 Maintenance - Cleaning the Feeder Body Pellet nes will accumulate in the feeder body over a period of time; therefore, a yearly inspection and cleaning of this area must be performed. T ocleanoutnes: 1. Remove the rear cover panels. 2. Remove wing nut and feeder cover on the side of ...

  • Harman Stove Company P43 - page 26

    26 P43 Pellet Stove FEEDER DOES NOT FEED 1. No pellets in hopper . 2. Firebox draft may be too low for low draft pressure switch in feeder circuit to operate. Check for closed doors , loose or missing gasket on doors or hopper lid, or a faulty pressure switch. 3. Fe ed mot or wil l not ru n unt il th e ESP co ntr ol se nses 165 deg. F . Maybe you d ...

  • Harman Stove Company P43 - page 27

    27 P43 Pellet Stove P43 Feeder ...

  • Harman Stove Company P43 - page 28

    28 P43 Pellet Stove Weight 212 lbs. Blower 135 cfm Feed Rate approximate .75lb. to 5.5 lbs per hr Hopper Capacity 50 lbs Fuel Wood Pellets Flue Size 3 inch Outside Air Size 2 3/8" I.D. inch Fuse Rating 6 amp P43 Specications 12.375" 5.25" 32" 9" 22" 28.5" ...

  • Harman Stove Company P43 - page 29

    29 P43 Pellet Stove OPTIONS Side Heat Shields Side heat shields are available to reduce the clearance to combustible materials. Part #1-00-00000 Hopper Extension The hoppe r ext ensi on allows you to put more pellet fuel in the hopper and extends burn time on one load of pellets. The hopper extension adds 60 pounds to the existing 60 pound hopper c ...

  • Harman Stove Company P43 - page 30

    30 P43 Pellet Stove P43 Wiring Diagram ...

  • Harman Stove Company P43 - page 31

    31 P43 Pellet Stove Description Part Number Hopper Gasket(5 ft.) 0-88-00248 Ash Pan Assembly 1-10-7738108 Burn Pot Weldment 1-10-00675 Right Rear Shield 2-00-773828-1P Left Rear Shield 2-00-773828-2P Arrow Scraper 2-00-773850 Flame Guide 3-00-03000 Wiring Harness Assembly 3-20-08727 Thermister Probe 3-20-00844(red wire) Room Sensor 3-20-00906 Circu ...

  • Harman Stove Company P43 - page 32

    HARMAN GOLD W ARRANTY 6 YEAR TRANSFERABLE LIMITED W ARRANTY (Residential) 1 YEAR LIMITED W ARRANTY (Commercial) Harman warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service, for ...

Produzent Harman Stove Company Kategorie Stove

Dokumente, die wir vom Produzenten des Geräts Harman Stove Company P43 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Harman Stove Company
- Bedienungsanleitungen P43
- Produktkarten Harman Stove Company
- Informationsbroschüren
- oder Energieetiketten Harman Stove Company P43
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Harman Stove Company P43.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Harman Stove Company P43, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Harman Stove Company P43. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Harman Stove Company P43 ansehen.

Die komplette Bedienungsanleitung des Geräts Harman Stove Company P43, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Harman Stove Company P43 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Harman Stove Company P43 verständlich ist.

Eine gänzliche Bedienungsanleitung von Harman Stove Company sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Harman Stove Company P43 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Harman Stove Company P43 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Harman Stove Company P43, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Harman Stove Company P43 - die uns die ersten Schritte während der Nutzung von Harman Stove Company P43 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Harman Stove Company P43 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Harman Stove Company P43 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Harman Stove Company P43?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Harman Stove Company P43 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Harman Stove Company P43 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)