APC SMT1000RMI2U-B - page 1
Oper at ion Ma nual Smart -UPS ® UP S 750/1000/ 1500/2200 V A Rack-mount 2U 120/ 2 30 V AC 3000 V A R ack-m oun t 2U 120/2 08 /23 0 V A C ...
-
APC SMT1000RMI2U-B - page 2
Cont ent s Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount i Ove r v iew ........ ....... ............ ............. ............ ...... ............. ... 1 Product Descript ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safe ty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
-
APC SMT1000RMI2U-B - page 3
Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount ii Emerg ency Power Of f . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 EP O Ov er vie w . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 No rm ally op en c on tac ts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
-
APC SMT1000RMI2U-B - page 4
1 Smar t-UPS 7 50-3000 VA 120/208/ 230 Vac Rack-mount Overview Prod uc t Description The APC ® by Schneider Elec tric Smart- UP S ® 750-3 000 V A 120/2 08/230 V a c Rack-mount is a hi gh performanc e unin terruptible power supply ( UPS). It provides protec tion for electr onic equi pment from utility powe r blackouts , brownouts, sags, an d sur g ...
-
APC SMT1000RMI2U-B - page 5
Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount 2 Rear p anel s Sm artSl ot for option al NMC ac ces sory card UPS i nput Circu it break er/Overload pr otection Control led outl et group Chass is ground conne ction s crew (TVSS GND) Outle ts EPO conne ctor USB port RJ45 c onnector - seria l UPS m o nitoring ...
-
APC SMT1000RMI2U-B - page 6
3 Smar t-UPS 7 50-3000 VA 120/208/ 230 Vac Rack-mount Specifications Ope r atin g C ond it ion s This unit is intended for i ndoor us e only . Select a l ocati on sturdy enough t o suppor t the weight of the UPS. Do not o perate the unit wher e there is excessi ve dus t, or t he temper ature or humidi ty are outside t he sp e c if ie d l im i ts. A ...
-
APC SMT1000RMI2U-B - page 7
Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount 4 Operat ion Conn ect Eq uipm ent to th e U PS Note: The UPS will char ge to 90% ca pacity in the first thr ee hours of normal operati on. Do not expect fu ll b att ery runtime capabili ty during this initi al charge period. 1. Connect equipm ent to the outl ets on the r ear panel of the UPS. Do ...
-
APC SMT1000RMI2U-B - page 8
5 Smar t-UPS 7 50-3000 VA 120/208/ 230 Vac Rack-mount Displa y Inter face Ov ervi ew Usin g the di splay inte rface Use the U P and D OWN buttons t o s croll th rough t he main menu options. Press E NT ER to view the sub- menus under each main menu option . P re ss E SC APE to exit a sub-menu and return to a main menu. St andard m enus The Stan dar ...
-
APC SMT1000RMI2U-B - page 9
Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount 6 Ad van ced me nu s The Advanc ed menus provide additi ona l options for th e UPS and are a vailabl e only if the display interf ace is configure d to us e the Advanced me nus. About Displ ay in format ion about th is un it: • Unit mod el number • Ser ial nu mber • Battery inform ation • ...
-
APC SMT1000RMI2U-B - page 10
7 Smar t-UPS 7 50-3000 VA 120/208/ 230 Vac Rack-mount Config uration UP S Sett ing s St a rt-up Se ttings Configure the se settings at initi al start-up, us ing the display inte rface or APC P o we rCh ute ® soft ware. Note: Durin g st art-up, u se the displ a y interface to c onfigure t hese settings. If not hing is selected, the unit wi ll use t ...
-
APC SMT1000RMI2U-B - page 11
Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount 8 Low T r an sfer Poin t 120 V : 106 V ac • 97 V ac • 100 V ac • 103 V ac • 106 V ac Se t th e tra ns fer p oi n t low er if the uti lit y volta ge is chronic ally lo w and the conne cted equip ment ca n tolera te this condit ion.T his set ting may also be adju sted usin g the powe r qual ...
-
APC SMT1000RMI2U-B - page 12
9 Smar t-UPS 7 50-3000 VA 120/208/ 230 Vac Rack-mount Main Outlet Grou p and the Switched Outle t Group Ov ervi ew The Main Outlet Gr o up and t he Switched Outlet Gr oup can be configu red to i ndependent ly turn of f, t urn on, shut down, and reboot co nnected equipment. (These features are not avai lable on the 750 V A tower units.) The Main Out ...
-
APC SMT1000RMI2U-B - page 13
Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount 10 N etw or k Ma na ge ment C ard Set ti n gs These setti ngs are available only on units tha t have a Network Management Card (NMC) and are set in the factor y . T he se se ttings can o nly be modified usi ng an external int erfa c e, l ike the NMC web inter face. • NMC IP Addre ss Mode • NM ...
-
APC SMT1000RMI2U-B - page 14
11 Smar t-UPS 750-3000 VA 120/2 08/230 Vac Rack- m ount Emer gency P ower Off EPO Over view The Emerge ncy Power Off (EPO) opt ion is a safety featu re that will immedia tely disconne c t all connected equ ipment from utili ty power . The UPS will immediate ly shut down and wi ll not switch to battery power . The UPS must be manually r estart e d t ...
-
APC SMT1000RMI2U-B - page 15
Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount 12 T roublesh oot ing Pr oblem and Possible Cause Solution The UPS will not turn on or t here is n o output The unit has not been turned o n. Pres s the ON butt on o nce to turn on the UPS. The UPS i s not c onnected to u tilit y power . Ens ure th at the po w e r cab le is s ecure ly con nec ted ...
-
APC SMT1000RMI2U-B - page 16
13 Smar t-UPS 750-3000 VA 120/2 08/230 Vac Rack- m ount The repl ace batte ry in dica tor is illum in ated The battery has a weak charge . Allow th e battery to rechar ge for at lea s t four hours. Then, perform a self-t est. I f the prob lem persis ts after rec harg ing, replace th e battery . The repla cement ba ttery is not pro perly conne cted. ...
-
APC SMT1000RMI2U-B - page 17
Smart-UPS 750-300 0 VA 120 /208/230 Va c Rac k-mount 14 Servi ce and Su pport Se rvice If the unit requires servic e, do not re turn it t o t he dealer . Follow these steps: 1. Review t he T r oubleshoo ting sect ion of th e manual to el iminate common problems. 2. If the probl e m pe rsist s, contact APC Cus tomer Support through the APC W e b sit ...
-
APC SMT1000RMI2U-B - page 18
15 Smar t-UPS 750-3000 VA 120/2 08/230 Vac Rack- m ount APC W orldwide Customer Suppor t Customer suppor t for this or any othe r APC product is availa ble at no charge in any of the following ways: • V isit the APC W eb site to access docu ments in the APC Knowledge Base and to submit custom er support reque sts. – www . apc. com (Co rporate H ...
-
APC SMT1000RMI2U-B - page 19
Smart-UPS F actory W arrant y LIMI TED W ARR AN TY Ameri can Pow er Conv ers ion (APC) warr ants i ts Smart -UP S (P rodu cts) t o be free f rom defe cts in mater ial s and wor kmanshi p fo r a perio d of thr ee (3) ye ars, ex cludi ng the ba tter ies, wh ich are wa rrant ed for tw o (2) yea rs fro m date of pur ch ase. APC's oblig atio n unde ...
-
APC SMT1000RMI2U-B - page 20
06/20 10 990- 3858 © 2010 APC by Schneide r Electri c. APC, the APC log o are owned by S chneider El ectric Indu stries S.A.S. , Ameri can Power Conver sion Corpora tion, o r their af fil iated compan ies. All othe r trademar ks are propert y of the ir res pec ti ve o wne r s. ...
Haben Sie eine Frage bezüglich APC SMT1000RMI2U-B?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit APC SMT1000RMI2U-B nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit APC SMT1000RMI2U-B hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.