    S T AND A LONE A CCESS C ONTROL ECP190 / ECP290 DOOR CONTROLLERS  ® Site Coded & Sequentially Number ed Access Passes for Security , Identification & Operational Integrity . ECP190 / ECP290 DOOR CONTROLLERS Site Coded & Sequentially Number ed Access Passes for Security , Identification & Operational Integrity . nacd.co .uk ...

  • Pelco ECP290 - page 2

    2 contents Explanation of Noralsy ® Access P asses 3 General Door Controller Inf ormation 4 ECP 190 Door Controller schematic 5 ECP 290 Door Controller schematic 6 How to use the T elpro ™ progr ammer 7-8 Programming Set-up on installation 9-10 Block loading of Access P asses 10 Deleting individual Access P asses 10-11 V alidating individual Acc ...

  • Pelco ECP290 - page 3

    3 N ORALSY ® A CCESS P ASSES Site Code The number of each and e very Access Pass is visib le. Just b y looking at it, y ou kno w which Access Pass y ou have . Noralsy ® pre-number each Access P ass because this is the only way y ou can know f or sure what you ha ve received, what y ou need to program the system to accept (or , reject in the case ...

  • Pelco ECP290 - page 4

    4 ® Noralsy ECP Door Controllers 1 2 3 1 2 4 5 6 3 1 2 3 1 2 4 3 1 2 3 1 2 4 5 3 1 2 3 1 2 3 1 2 1 2 3 1 2 4 3 1 2 4 5 3 1 2 4 5 6 3 1 2 4 5 6 7 3 1 2 4 5 6 7 8 3 1 2 1 2 4 5 6 3 65432 1 654321 1 Standardisation of T erminal Numbering Place Noralsy unit on a flat surface with PCB facing skywards. V iew terminal blocks fr om the outside looking in. ...

  • Pelco ECP290 - page 5

    12345 6 = 12345 6 32 1 21 123456 32 1 1O N 5 4 3 2 1 1 2 3 4 5 = 32 1 2 1 (—) (+) 5 ® ECP190 Door Controller for 1 n 0 Door/Access Point ■ Capacity 999 Users ELEC/INST/801 Supply 12V DC ± 10% Dimensions 103 L x 106 W x 83 D (6 DIN units) W eight 0.44 Kg Power Consumption 55mA quiescent CE Norms EN50082, EN55022 Class B ECP 190 Door Controller ...

  • Pelco ECP290 - page 6

    6 ® ECP290 Door Controller for 2n 0 Doors/Access Points ANTI-P ASSBA CK FEA TURE A V AILABLE Supply 12V DC ± 10% Dimensions 163 L x 106 W x 83 D (10 DIN units) W eight 0.56 Kg Power Consumption 160mA quiescent CE Norms EN50082, EN55022 Class B ECP 290 Door Controller ■ Capacity 999 Users per door ELEC/INST/830 * If not used, link terminals 3 &a ...

  • Pelco ECP290 - page 7

    7 ® Programming Stand-Alone Access Control Systems using TELPRO™ Programmer . MLP3 Proximity MIR Infra-Red MILB Card Reader LB20 Swipe Card ECP190 ECP290 ECP100 ECP200 Access Contr ol Modules, Readers, Receiver s without integral Infra-Red Access Contr ol Modules with integral Infra-Red The TELPRO™ Programmer is supplied with a connector cable ...

  • Pelco ECP290 - page 8

    Important : Each press of a button is confirmed (as r eceived) by the r eader/r eceiver by a single beep. Press the TELPRO ™ buttons gently . Programming using TELPRO ™ as a remote wire-free programmer . Remote Programming Range: Infra-Red Receiver 20 cms - 5 metres Proximity Reader 5 cms - 10 cms How to use the TELPRO: Flick TELPRO switch to O ...

  • Pelco ECP290 - page 9

    9 PROGRAMMING 08 Example Basic configuration, just do it! Basic configuration, just do it! seconds ECP Door Controller with ACCESS P ASS CONTROL TOP POINTS TO REMEMBER ■ Programming is ef fected via the TELPRO programming keypad. ■ Site Code is always a 5 digit number . ■ Site Code is always stored in Slot N o . 01. ■ Master Code (Programmi ...

  • Pelco ECP290 - page 10

    10 *See Tip Wizard on page 13 * STEP 4 Y ou must now inform the Door Controller of the Site Code of the Access Passes supplied. The Site Code is always stored in Slot N o . 01. The Site Code is always a 5 digit number . Check the Access Pass Information Sheet delivered with the Access Passes. It will tell you the Site Code of the Access Passes deli ...

  • Pelco ECP290 - page 11

    11 After a beep enter on the TELPRO: A sharp beep confirms that you have correctly deleted Holder Number 074. Pr ogramming mode beep - every 4 seconds - resumes. Example C: V alidation of 1n o . Access Pass Y ou have just received the additional Access Pass order ed for Alan Jones who had lost his earlier in the week. The last 3n o . digits on the ...

  • Pelco ECP290 - page 12

    12 ECP290 D OOR C ONTROLLER FOR 2 D OORS – I MPORT ANT I NFORMA TION FLICKING PROGRAMMING SWITCH SW1. The access control readers on both doors will star t to beep ev er y 4 seconds indicating programming mode status . Only 1 n o . access point (door) can be programmed at a time . IF USING THE TELPRO PROGRAMMER IN WIREFREE INFRA-RED MODE: Simply p ...

  • Pelco ECP290 - page 13

    13 Mode 4 - Dual Security , Access Pass + K e ypad Code 00 4 00508 = Set-Up , Mode 4 È Rela y output time in seconds User required to present a valid access pass and then enter a v alid code or vice versa in order to gain access . A maximum of 27n o .5 digit ke ypad codes can be set at any one time. An y 1no . of these ke ypad codes together with ...

  • Pelco ECP290 - page 14

    14 ® ® Noralsy® ECP Door Controller 32 1 2 1 32 1 654321 65432 1 1 2 4 5 6 3 6 5 3 2 1 4 32 1 + 21 32 1 (—) (+) Fail Safe Locking ECP190 Door Controller ECP190 Door Controller ECP190 Door Controller Automation Control / V olt Free Entrance/Exit Access point requiring access contr ol on both sides of the door , gate or barrier . ie. Access Pass ...

  • Pelco ECP290 - page 15

    15 ® ® 32 1 (–) (+) 21 32 1 Locking ECP190 Door Controller Noralsy® ECP Door Controller DIN Rail Mounting W all Mounting DIN Rail ELEC/INST/805 ELEC/INST/806 ELEC/INST/807 ...

  • Pelco ECP290 - page 16

     ®  ® 16 Noralsy® DIN Rail Power Supplies ELEC/INST/808 ELEC/INST/809 ELEC/INST/810 ELEC/INST/811 ARE121 12V AC/DC 1 AMP MAXIMUM OUTPUT ARE122 12V DC 2 AMP MAXIMUM OUTPUT ARS122 12V DC 2 AMP MAXIMUM OUTPUT AB126 BA TTER Y ST ANDBY ...

  • Pelco ECP290 - page 17

    17 ® Noralsy® Powering ECP Door Controller(s) using Noralsy® DIN Rail Power Supply Units ELEC/INST/812 ARE121 + ECP190 ARE122 + ECP290 ELEC/INST/812A ...

  • Pelco ECP290 - page 18

    18 ECP190 DOOR CONTROLLER with KEYP AD ACCESS CODE CONTROL TOP POINTS TO REMEMBER ■ Programming is ef fected directly via the keypad. ■ Master Code (Programming Access Code) is always a 5 digit number . ■ Master Code is always stored in Slot N o . 06. ■ Keypad Access Codes are always 5 digit numbers. ■ Keypad Access Codes can be stored in ...

  • Pelco ECP290 - page 19

    19 After a beep enter on the keypad: A sharp beep confirms that you have deleted Alan’ s code. Programming mode beep - every 4 seconds - resumes. After a beep enter on the keypad: A sharp beep confirms that you have deleted Alex’ s code. Programming mode beep - every 4 seconds - resumes. Note 1. Y ou do not need to know the actual code itself w ...

  • Pelco ECP290 - page 20

    N.A.C.D. Limited Unit 10, Avebury Court, Mark Road, Hemel Hempstead, Her ts HP2 7T A. TEL: 01442 211848 F AX: 01442 212776 EMAIL: sales@nacd.co.uk WEB: www.nacd.co.uk Our policy is one of continuous product impr ovement, we reserve the right to change specifications and prices without notice. All information is given in good faith. No responsibilit ...

Produzent Pelco Kategorie Door

Dokumente, die wir vom Produzenten des Geräts Pelco ECP290 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Pelco
- Bedienungsanleitungen ECP290
- Produktkarten Pelco
- Informationsbroschüren
- oder Energieetiketten Pelco ECP290
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Pelco ECP290.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Pelco ECP290, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Pelco ECP290. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Pelco ECP290 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Pelco ECP290, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Pelco ECP290 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Pelco ECP290 verständlich ist.

Eine gänzliche Bedienungsanleitung von Pelco sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Pelco ECP290 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Pelco ECP290 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Pelco ECP290, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Pelco ECP290 - die uns die ersten Schritte während der Nutzung von Pelco ECP290 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Pelco ECP290 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Pelco ECP290 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Pelco ECP290?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Pelco ECP290 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Pelco ECP290 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)