Bedienungsanleitung Oregon Scientific PS-M03

28 Seiten 0.24 mb
Download

Zur Seite of 28

Summary
  • Oregon Scientific PS-M03 - page 1

    Full Weather Station with Radio Controlled Clock and AM / FM Radio (Model #: PS-M03 / PS-M03U) User Manual PS M03 English Cover 6/30/03, 11:11 PM 1 ...

  • Oregon Scientific PS-M03 - page 2

    EN 1 TABLE OF CONTENTS About this guide ......................................................... 2 Product overview ........................................................ 3 Getting started ........................................................... 8 Batteries ............................................................... 8 AC power adapter ... ...

  • Oregon Scientific PS-M03 - page 3

    EN 2 ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck with Oregon Scientific Full Weather Station with Radio Controlled Clock and AM / FM Radio (PS-M03 / PS-M03U). This powerful device bundles time keeping, alarm, indoor and wireless outdoor temperature and humidity monitoring, weather forecasting, and digital-tuned AM/ FM ...

  • Oregon Scientific PS-M03 - page 4

    EN 3 PRODUCT OVERVIEW TOP AND BATTERY COMPARTMENT VIEW DESCRIPTIONS 1. Snooze / Light button ( 12, 19) 2. Light sensor ( 19) 2 1 PS M03 English R18 7/16/03, 1:04 PM 3 ...

  • Oregon Scientific PS-M03 - page 5

    EN 4 BOTTOM AND SIDE VIEW DESCRIPTIONS 1. Battery compartment ( 8) 2. Backlight switch ( 19) 3. Reset button ( 8, 20) 4. Light sensitivity knob ( 19) 5. Headphone jack ( 18) 6. DC input jack ( 8) 7. Antenna ( 17) AC power adapter not shown. NOTE RESET SENSOR ON LIGHT OFF AUTO LIGHT DC 7.5V 1 3 2 5 7 6 4 PS M03 English R18 7/16/03, 1:04 PM 4 ...

  • Oregon Scientific PS-M03 - page 6

    EN 5 LCD DISPLAY DESCRIPTIONS 1. Low battery icon ( 8) 2. Clock ( 10) 3. Barometer ( 13) 4. Weather forecast ( 14) 5. Moon phase ( 13) 6. Calendar ( 12) 7. Temperature and humidity ( 15) 8. Alarm ( 11) 9. Radio ( 17) 1 2 3 4 5 6 7 8 9 PS M03 English R18 7/16/03, 1:04 PM 5 ...

  • Oregon Scientific PS-M03 - page 7

    EN 6 BACK VIEW BUTTON DESCRIPTIONS 1. Select - switch modes / change settings ( 8, 9) 2. Up - increase setting / activate auto-synch ( 10) 3. Down - decrease setting / deactivate auto-synch ( 10) 4. Alarm -activate / deactivate alarm ( 12) 5. Channel - switch remote unit ( 15) 6. Radio - turn radio or radio alarm on/off ( 12, 17) 7. Station -select ...

  • Oregon Scientific PS-M03 - page 8

    EN 7 REMOTE UNIT DESCRIPTIONS 1. Temperature / Trend display ( 15, 17) 2. Low battery icon ( 8) 3. Humidity / Trend / Comfort Level display ( 15, 16, 17) 4. ° C/ ° F switch ( 9) 5. Channel switch ( 9) 6. Reset button ( 8, 20) 7. Battery compartment ( 8) 8. Wall mount hole 9. Battery compartment lid 1 2 5 3 4 6 7 8 9 PS M03 English R18 7/16/03, 1: ...

  • Oregon Scientific PS-M03 - page 9

    EN 8 GETTING STARTED BATTERIES Batteries for the remote and main units are supplied with this product. Replace them whenever the low battery signal ( ) displays. Remove the battery compartment lid on the bottom of the main unit, and insert the batteries. Use a small Phillips screwdriver to remove the remote unit compartment lid. Be sure to match th ...

  • Oregon Scientific PS-M03 - page 10

    EN 9 CHANGE SETTINGS Press and hold SELECT for 2 seconds. Then, press UP or DOWN to change each setting. Press SELECT to switch options. REMOTE UNIT SET UP Up to 3 remote units can be used with this product to monitor outdoor temperature and humidity. The measurement unit ( ° C or ° F) and channel number (1, 2, or 3) switches are located in the b ...

  • Oregon Scientific PS-M03 - page 11

    EN 10 CLOCK This product can automatically synchronize the date and time with official time-keeping organizations in Frankfurt, Germany (PS-M03) or Rugby, England (PS-M03U). When the unit is within 1500 km (932 miles) of a RF signal, the reception icon will blink during reception. RECEPTION Reception takes 2 - 10 minutes to complete. Once complete, ...

  • Oregon Scientific PS-M03 - page 12

    EN 11 SET OR CHANGE THE CLOCK 1. Press SELECT to switch to the Clock Mode. The time will flash. 2. Press and hold SELECT for 2 seconds to enter the setting mode. 3. Select the 12/24-hour format, hour, and minute. Press UP or DOWN to change the setting. Press SELECT to confirm. ALARM When activated, the Melody Alarm starts quietly, then gradually be ...

  • Oregon Scientific PS-M03 - page 13

    EN 12 If you choose , use the radio control buttons to select the AM/FM band, radio station and volume level ( 18) . 4. Press SELECT again when you are finished. SNOOZE Press the SNOOZE/LIGHT button the top of the unit to temporarily disable the alarm for 8 minutes. The alarm icon will blink while Snooze is activated. TO TURN THE ALARM OFF OR ON Pr ...

  • Oregon Scientific PS-M03 - page 14

    EN 13 MOON PHASE Press SELECT until the Calendar Area flashes. Then, press UP or DOWN to change the date and view the corresponding moon phase. BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast ( 14) and a trend line showing the direction of barometric change. Barometric changes are mea ...

  • Oregon Scientific PS-M03 - page 15

    EN 14 WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 to 50 km (19 - 31 mile) radius with 70 to 75 percent accuracy. The weather forecast is always displayed. VIEW THE LAST 24 HOURS Press SELECT 2 times until the Barometer Area flashes. Then, press UP or DOWN to view the last 24 hours history. SET UNIT AND ALT ...

  • Oregon Scientific PS-M03 - page 16

    EN 15 CLEAR MIN / MAX RECORDS While viewing Min/Max records, press and hold UP or DOWN for 2 seconds until a beep sounds. This clears the previous measurements from the memory. SELECT REMOTE UNIT CHANNEL While in the Temperature / Humidity Mode, press CHANNEL to switch between CH 1, 2, or 3, or press and hold CHANNEL for 2 seconds to enter Auto sca ...

  • Oregon Scientific PS-M03 - page 17

    EN 16 SENSOR SEARCHING If there is no remote unit signal, the temperature and humidity measurements will be blank. Check the remote unit batteries, or press and hold UP and DOWN for 2 seconds to search for the remote unit(s). Signals from household electrical appliances such as doorbells and home security systems can cause temporary reception failu ...

  • Oregon Scientific PS-M03 - page 18

    EN 17 SET UNIT While in Temperature / Humidity Mode, press SELECT for 2 seconds. Press UP or DOWN to switch between ° C and ° F. Press SELECT to confirm. RADIO You can listen to Phase Lock Loop (PLL) digital radio broadcasts with this product. ANTENNA The antenna wire is located on the side of the unit. Position it for the best reception. TURN TH ...

  • Oregon Scientific PS-M03 - page 19

    EN 18 VOLUME Press UP or DOWN . There are 8 volume levels. SWITCH AM/FM BAND Press TUNING to enable auto tuning. Press again to switch AM/FM band. SELECT STATION Press STATION . There are 16 preset channels: 8 for FM and 8 for AM. TUNING Press TUNING . Then, press UP or DOWN to scan the available frequencies. Press and hold UP or DOWN for 2 seconds ...

  • Oregon Scientific PS-M03 - page 20

    EN 19 3. The Light sensitivity knob is located in the battery compartment. Rotate to adjust. 4. When activated, the continuous backlight will be half as bright as usual. To achieve full brightness, press SNOOZE/LIGHT. BACKLIGHT Press SNOOZE/LIGHT to illuminate the backlight for 5 seconds. CONTINUOUS BACKLIGHT The AC power adapter must be plugged in ...

  • Oregon Scientific PS-M03 - page 21

    EN 20 WARNINGS This product is designed to give you years of service if handled properly. Observe the following guidelines: • Never immerse the unit in water. This can cause electrical shock and damage the unit. • Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity. • Do not tamper with the interna ...

  • Oregon Scientific PS-M03 - page 22

    EN 21 • Do not make any changes or modifications to this product. Unauthorized changes may void your right to use the product. • The contents of this user guide are subject to change without notice. • Images not drawn to scale. TROUBLESHOOTING Check here before contacting our customer service department. Baro Strange reading Set altitude / un ...

  • Oregon Scientific PS-M03 - page 23

    EN 22 Radio Problem Symptom Remedy Select radio format ( 10) Reception is poor / static Place clock near a window ( 10) Remote unit Cannot locate remote unit Check batteries ( 8) Check location ( 9) Disable auto- synchronization ( 10) Cannot change clock Adjust the antenna ( 17) Problem Symptom Remedy Clock Cannot auto-synchronize 1. Remove batteri ...

  • Oregon Scientific PS-M03 - page 24

    EN 23 Problem Symptom Remedy Temp Shows “LLL” or “HHH” Temperature is out-of- range. Cannot change channel Check sensors. Only one sensor is working ( 15) SPECIFICATIONS Dimensions: L x W x H 129 x 43 x 133.3 mm (5.1 x 1.7 x 5.3 inches) Weight 525 grams with batteries Remote unit dimensions L x W x H 75 x 35 x 78.3 mm (3 x 1.4 x 3.1 in) Wei ...

  • Oregon Scientific PS-M03 - page 25

    EN 24 Barometer Unit mb/hPa or inHg Range 500 to 1050 mb (14.77 to 31.01 inHg) Resolution 1 mb (0.03 inHg) Altitude -100 to 2500 meters (-328 to 8202 feet) Display Rainy, cloudy, partly cloudy, sunny Memory 24 hour Trend 1mb change in 1 hour or 3mb change in 6 hours Remote unit RF frequency 433 MHz Range 30 meters (98 feet) with no obstructions Tra ...

  • Oregon Scientific PS-M03 - page 26

    EN 25 Channel No. 1, 2, or 3 Unit ° C or ° F Radio-controlled clock Synchronization Auto or disabled Clock display HH:MM:SS Hour format 12hr AM/PM (MSF format) 24hr (DCF format) Calendar DD/MMM; weekday selection in 5 languages (E, D, F, I, S) Alarm 7 melody or radio; 2 minute crescendo (melody only) Snooze 8 minutes (melody only) Radio Type Digi ...

  • Oregon Scientific PS-M03 - page 27

    EN 26 ADDITIONAL RESOURCES Visit our website (www.oregonscientific.com) to learn more about your new product and other Oregon Scientific products such as digital cameras, hand-held organizers, health and fitness gear, and weather stations. The website also includes contact information for our customer service department, in case you need to reach u ...

  • Oregon Scientific PS-M03 - page 28

    EN 27 EC-DECLARATION OF CONFORMITY This product contains the approved transmitter module TX 07 and complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC Directives, if used for its intended use and that the following standard(s) has/have been applied: Radio frequency spectrum (Article 3.2 of the R&TTE Directive) appli ...

Produzent Oregon Scientific Kategorie Clock

Dokumente, die wir vom Produzenten des Geräts Oregon Scientific PS-M03 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Oregon Scientific
- Bedienungsanleitungen PS-M03
- Produktkarten Oregon Scientific
- Informationsbroschüren
- oder Energieetiketten Oregon Scientific PS-M03
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Oregon Scientific PS-M03.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Oregon Scientific PS-M03, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Oregon Scientific PS-M03. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Oregon Scientific PS-M03 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Oregon Scientific PS-M03, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Oregon Scientific PS-M03 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Oregon Scientific PS-M03 verständlich ist.

Eine gänzliche Bedienungsanleitung von Oregon Scientific sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Oregon Scientific PS-M03 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Oregon Scientific PS-M03 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Oregon Scientific PS-M03, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Oregon Scientific PS-M03 - die uns die ersten Schritte während der Nutzung von Oregon Scientific PS-M03 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Oregon Scientific PS-M03 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Oregon Scientific PS-M03 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Oregon Scientific PS-M03?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Oregon Scientific PS-M03 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Oregon Scientific PS-M03 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)