Bedienungsanleitung QUINCY HYDRONIC TECHNOLOGY Air Compressor

23 Seiten 0.31 mb
Download

Zur Seite of 23

Summary
  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 1

    DO NOT store or use gasoline or othe r flamma ble vapors or liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS VAPORS • Do not try to light any app liance • Do not touch any electric sw itch; do not use any phone in you r building • Immediately call yo u r gas supplier fro m a neighbors phone. • If you can n ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 2

    ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 3

    T ABLE OF CONTENTS QHT INC. OIL DIRECT VENT PACKAGES Section Page Important Info & Warnings 1-3 General Information & Installation Explosions 1 4-5 Vent System Installation 2 6 E x t e r n a l C l e a r a n c e s 6 C l e a r a n c e s t o C o m b u s t i b l e s 7 DVH-5 System 2.1 8 Installation of Make-up Air 2.2 9 Burner Setup Installatio ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 4

    ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL PLUMBING, HEAT ING AND ELECTRICAL CODES AND ORDINANCES, AS WELL AS THE REGULA TIONS OF THE SERV ING ELECTRICAL, WATER AND GAS UTILITIES. All system s should be desi gned by com petent contractors , and only pers ons knowled geable in the lay out and installation of heating s ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 5

    • ALL BOILERS MUST BE INST ALLED IN ACCORDANCE WITH NATIONA L, STATE AND LOCAL PLUMBING, HEA T IN G A ND ELECTRICAL CODES AND ORDINANCE S, AS WEL L AS THE REGULATIONS OF THE S ERVING ELECTR ICAL, WATER AND GAS UT ILITIES. • Improper i nstallation, a djustment, or maint enance of this boi ler can cause property dam age, personal injury or death. ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 6

    Any appliance that burns natural g as, propane gas, fuel oil, wood or coal is capable of producing carbon monoxide (CO). Car bon Monoxide (CO) is a ga s which is od orless, color less and tasteless but is very toxi c. If your B IASI boiler is not wor king properl y, or is not vented p roperly, d angerous l evels of CO may accumulate. CO is lighter ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 7

    The QHT Direct Vent components have been designed and packaged so that the Biasi B-10 and SG boilers can be directly vented to the outside. Properly maintained, these boiler systems are unsurpassed in efficiency and will p r ovide years of trouble-free operation. In addition to the standard Biasi boiler pack age, the Direct Vent Package is supplied ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 8

    5 DVH-5 V ent System QHT DIRECT VENT OIL KITS Apply 5” X 2’ insulati on sleeve fr om hood connection down over ex haust elbow before attaching S.S. Flex pipe. # DESCRIPTION PART # # DESCRIPTION PART # 1 4” Tee D-4”TEE 9 5” 90° Vent Elbow D-5”ELBSS 2 4” Bar ometric Dam per D-4”DAMP 10 5” Concentric Vent Hood D-5”CONHOOD 3 4” 9 ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 9

    The Exhaust Hood must be installed on the leeward side of house and conform to the following guidelines: 1. The Vent hood shall be i nstalled 12” a bove ground le vel or 12” ab ove nominal snow level of t he region of the installation. 2. The Vent hood shall not be less than 3 feet abov e any forced air inlet to the house. 3. The Vent hood shal ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 10

    The boiler shall be placed so that the ve nt pipe is as s hort as practical. The VENT HOOD must be installed at least one foot above ground level or normal snow ac- cumulation level in an area which is free of obs truction at all tim es. The Vent hood should be installed on the leeward si de of the house out of the wind. Ou tside air must be ducted ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 11

    The B10/SG Direct Vent System s must be installe d where provisions do not exist for the du cting of combustion by products to the outside. The direct vent connector shall no t pass through any floor or ceiling. The burner exh aust must be duct ed directly to the vent hood t hrough listed e xhaust pipe s provided. Th e exhaust pipe throughout it&ap ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 12

    For DVH kits: 4. Use 4 inch dia meter flex pipe that is provi ded in the kit or a com parable single wal l metal pipe. The maximum allowable lengt h of intake pipe is ten feet not includin g elbows. 5. Begin instal ling the 4” tee t o the burner (R iello and Heat Wise require t he supplied 3” to 4” increase r to be installed first). Secure al ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 13

    10 In all boilers, regar dle ss of fu el being bu r nt or confi guration, a 10” X 10” Cerafi be r pad should be install e d under the fl ame. This pad i s not for aco ustic purposes , it is to keep the area under the nozzle warm to prevent flame out. Good, reliable ope ration with a minim um of servi ce starts with attention to the small detail ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 14

    11 3.1 B-10 Burner Setup Boiler Model B10-3 B10-4 B10-5 B10-6 Burner Mo del BF-3 BF-3 BF-5 BF-5 Firing Rate 0.55 0.80 1.00 1.25 Insertion Depth 3.0” 3.0" 3.0" 3.0" Nozzle .4 X 80 .65 X 80 .85 X 60 1.00 X 60 Spray Pattern W W W W Pump Pressure 180 psi 175 psi 150 psi 175 psi Turbulator 2 3 2 3 Air Gate 3.2 4.7 3.4 5 BURNER MANUFAC T ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 15

    3.2 SG Burner Setup Boiler Model SG-2 SG-3 SG-4 Burner Mo del BF-3 BF-5 BF-5 Firing Rate 0.65 1.00 1.30 Insertion Depth 5.0" 5.0" 5.0" Nozzle .55 X 70 .85 X 60 1.10 X 80 Spray Pattern solid solid solid Pump Pressure 145 psi 145 psi 145 psi Turbulator 0 0 2 Air Gate 4.5 4.0 5.6 BURNER MANUFAC TURER Riello BF3 and BF5 BURNER MANUFACTUR ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 16

    The electricity to the boiler shall com e from a dedicat ed breaker in the electr ic service box. A service switch shoul d be mounte d on the side of t he boiler so the burner technici an can service t he burner and cont rols. The electrical wiring should be routed so as not to interfere with normal servicing of the boiler. Wiring done in the field ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 17

    4. W iring Note 2: All wiring must be done in accordance w ith applicable state, local and national codes. Use only copper conductors. 14 O P T I O N A L : C H E C K L O C A L C O D E S L O - W A T E R C U T O F F F I R E - O - M A T I C S R 3 0 1 T 1 T T 2 T T 3 T G N D L 1 N L 2 N L 3 N L 2 C F L 1 X 1 X 2 L 1 ( H O T ) L 2 ( N E U T R A L ) 1 2 ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 18

    4. W iring 15 Riello Burner w ithout post-purge co ntrol multi-z one, control w iring OPTIONAL: CHECK LOCAL CODES LO-WATER CUTOFF F I R E -O -M A T I C SR 301 T 1 T T 2 T T 3 T GND L1 N L2 N L3 N L2 CF L1 X1 X2 L1 (HOT) L2 (NEUTRAL) 120 VAC 15 AMP Breaker G W R B G W R B L 4006A N X (ALARM) L G Ground on Riello Chassis Aux terminal requires constan ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 19

    4. W iring 16 Riello Burner w ith post-purge control multi-z one, contr ol wiring ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 20

    4. W iring Note 2: All wiring must be done in accordance w ith applicable state, local and national codes. Use only copper conductors. 17 O P T I O N A L : C H E C K L O C A L C O D E S L O - W A T E R C U T O F F F I R E - O - M A T I C S R 3 0 1 T 1 T T 2 T T 3 T G N D L 1 N L 2 N L 3 N L 2 C F L 1 X 1 X 2 L 1 ( H O T ) L 2 ( N E U T R A L ) 1 2 ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 21

    5. System Start-up “For Y our Safety Rea d Before Operating” WARNING : If you do not follow these instructions exactly, a fire or explosion may result causing property damage, persona l injury or loss of lif e. WARNING : Improper instal lation, adjust ment, alterat ion, service or m aintenance can ca use property damage, perso nal injury or l o ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 22

    5) Smell for gas, i ncluding near the floor . If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step. 6) Turn on all electric power to the appliance. 7) Set thermostat to the desired setting. 8) On ce the system is lit, inspect the entire installation. 9) Make sure the pre ...

  • QUINCY HYDRONIC TECHNOLOGY Air Compressor - page 23

    20 7. Service & Maintenance In order to ensure that the boiler is operating properly, it should be inspected annually at the beginning of the heating season by a qualified se rvice technician. Failure to do regular maintenance on the boiler, could result in a loss of system efficiency as well as equipment failure. 1) Turn off all electrical pow ...

Produzent QUINCY HYDRONIC TECHNOLOGY Kategorie Air Compressor

Dokumente, die wir vom Produzenten des Geräts QUINCY HYDRONIC TECHNOLOGY Air Compressor erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen QUINCY HYDRONIC TECHNOLOGY
- Bedienungsanleitungen Air Compressor
- Produktkarten QUINCY HYDRONIC TECHNOLOGY
- Informationsbroschüren
- oder Energieetiketten QUINCY HYDRONIC TECHNOLOGY Air Compressor
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung QUINCY HYDRONIC TECHNOLOGY Air Compressor.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen QUINCY HYDRONIC TECHNOLOGY Air Compressor, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen QUINCY HYDRONIC TECHNOLOGY Air Compressor. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts QUINCY HYDRONIC TECHNOLOGY Air Compressor ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts QUINCY HYDRONIC TECHNOLOGY Air Compressor, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von QUINCY HYDRONIC TECHNOLOGY Air Compressor hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von QUINCY HYDRONIC TECHNOLOGY Air Compressor verständlich ist.

Eine gänzliche Bedienungsanleitung von QUINCY HYDRONIC TECHNOLOGY sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von QUINCY HYDRONIC TECHNOLOGY Air Compressor bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von QUINCY HYDRONIC TECHNOLOGY Air Compressor befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich QUINCY HYDRONIC TECHNOLOGY Air Compressor, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts QUINCY HYDRONIC TECHNOLOGY Air Compressor - die uns die ersten Schritte während der Nutzung von QUINCY HYDRONIC TECHNOLOGY Air Compressor erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit QUINCY HYDRONIC TECHNOLOGY Air Compressor hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von QUINCY HYDRONIC TECHNOLOGY Air Compressor im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich QUINCY HYDRONIC TECHNOLOGY Air Compressor?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit QUINCY HYDRONIC TECHNOLOGY Air Compressor nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit QUINCY HYDRONIC TECHNOLOGY Air Compressor hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)