  • Rinnai RHFE-750ETR - page 1

    — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of th is or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical s witch; do not use any phone in your building. • Immediately call y our gas supp lier from a neighbor’s phone. Follow the ...

  • Rinnai RHFE-750ETR - page 2

    2 Rinnai Corporation RHFE-750ETR Consumer Safety Information Safety Definitions ........................................ 2 Safety Behaviors and Practices .................. 3 Safety Features ........................................... 3 Specifications ................................................. 4 Features ..................................... ...

  • Rinnai RHFE-750ETR - page 3

    Rinnai Corporation RHFE-750ET R 3 Safety Behavior and Practices Safety Features • Overheat: The appli ance will automatically shut down when the appliance ex cee ds a predetermined temperature. • Flame Failure: The appliance will automatically shut down if the burner flame is extinguished. • Power Failure: The appliance will cut off the gas i ...

  • Rinnai RHFE-750ETR - page 4

    4 Rinnai Corporation RHFE-750ETR Application Inbuilt only; for residential inst allation, commercial setti ng, or manufacture d home; not designed for installation in a solid-fu el burning fireplace General Description Inbuilt convector, glass and steel fronted, ceramic lo g space heater with forced convection and po wer flue system Operation Push ...

  • Rinnai RHFE-750ETR - page 5

    Rinnai Corporation RHFE-750ET R 5 Features • Direct Vent: Intake air is taken from the outside and the combustion products are exhausted to the outside. Therefore the furnace has no effect on the quality of the indoor air. • Push Button Ignition: Only one push of the STANDBY/ON switch is all that is required to operate the heater. • Lock: The ...

  • Rinnai RHFE-750ETR - page 6

    6 Rinnai Corporation RHFE-750ETR Operating Instructions Front Panel Description Part Number Flat Metal - Black Front R2700 Flat Metal - Stainless Steel Front R2701 Radius (curved) Gla ss - Silver Front R2702 Radius (curved) Gla ss - Black Front R2703 Front Panel Models Front P anel (featu res are th e same f o r fl at and curved mod els) TIM ER IND ...

  • Rinnai RHFE-750ETR - page 7

    Rinnai Corporation RHFE-750ET R 7 • Use two 1.5V AAA batteries. • To replace batteries unscrew the battery compartment cover located on the back of the remote control counter clockwise. Ensure that the correct polarity is observed. The polarity is engraved into the battery compartment. Replace the cover by turning clockwise until a soft click i ...

  • Rinnai RHFE-750ETR - page 8

    8 Rinnai Corporation RHFE-750ETR Sequence of Operations The combustion fan will ru n for several seconds before ignition to purge the combustio n chamber of any gas. If the front burner fails to ignite the appliance will turn off and fault code 11 will be displayed. If the rear burner fails to ignite the appliance will turn off and make another att ...

  • Rinnai RHFE-750ETR - page 9

    Rinnai Corporation RHFE-750ET R 9 Adjusting the Temperature Pressing the UP and DOWN buttons will change the temperature setting by 2 degree (F) increments. The display will show “Temperature” and the new temperature as confirmation. The temperature can be set to: • L (Low) - burner is on minimum combustion • 60° F - 80° F in two degree i ...

  • Rinnai RHFE-750ETR - page 10

    10 Rinnai Corporation RHFE-750ETR Timers Programming the clock and timers The clock must be set before the timers will operate. The temperature setting during timer ope ration is the temperature last used when the appliance was on. During the steps belo w, if no button is pressed for 90 seconds then the screen will return to the current time displa ...

  • Rinnai RHFE-750ETR - page 11

    Rinnai Corporation RHFE-750ET R 11 Care and Maintenance Filters This appliance has two filters which are behind the louvers on either side of t he heater. The louvers are hinged to allow access to the filters. Dirty filters reduce the air flow and the appliance’ s Maintenance Repairs should be perform ed by a qualified service technician. The app ...

  • Rinnai RHFE-750ETR - page 12

    12 Rinnai Corporation RHFE-750ETR W ARNING Do not clean glass when hot. Do not clean glass with abrasive clean ers. Care and Maintenance Over time combustion products may leave a film on the combustion chamber g lass. Continued use of the appliance may permanentl y stain the glass. If filming occurs, this glass panel needs to be rem oved, cleaned, ...

  • Rinnai RHFE-750ETR - page 13

    Rinnai Corporation RHFE-750ET R 13 T roubleshooting No display on remote Replace the remote control batteries. No ignition or no panel indications Ensure the appliance has power. Press the control panel ON/OFF button. Burners fail to ignite Air may need to be purged from the gas line. Several ignition attempts may purge the gas line. Turn on the ga ...

  • Rinnai RHFE-750ETR - page 14

    14 Rinnai Corporation RHFE-750ETR Fault Codes If there is a malfunction the appliance may shut down as a safety precaution and display a fault code to assist in diagnosing the problem. The fault code will flash in the Fault Code Displa y window and the O peration Indicator will flash green. Code Fault Remedy 11 Ignition failure Confirm that the gas ...

  • Rinnai RHFE-750ETR - page 15

    Rinnai Corporation RHFE-750ET R 15 Inst allation Instructions General Instructions A qualified service technici an should install the appliance and inspect it before u se. The installation must conform with lo cal codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 , or the Natural Gas and Propane Installat ...

  • Rinnai RHFE-750ETR - page 16

    16 Rinnai Corporation RHFE-750ETR Flue T erminal Clearances INS I DE CO R N ER D E TA I L FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B M C F B B E D L G A H K I X V AIR SUPPLY INLET VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMITTTED ...

  • Rinnai RHFE-750ETR - page 17

    Rinnai Corporation RHFE-750ET R 17 Ref Description Canadian Installations US Installations A Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm) 12 inches ( 30 cm) B Clearance to window or door that may be opened 12 inches (30 cm) 9 inches (23 cm) C Clearance to permanently closed windo w * * D Vertical clearance to ventilated ...

  • Rinnai RHFE-750ETR - page 18

    18 Rinnai Corporation RHFE-750ETR Do not vent the exhaust into ‘natural draft’ flue pipes or a chimney flue. The enclosure must be within these limits: The front panel extends below the surfa ce on which the appliance rests. Ensure that clearance is maintained in order to install the front panel. Width (w) 33.8 in (860 mm) Height (h) 26.0 - 26. ...

  • Rinnai RHFE-750ETR - page 19

    Rinnai Corporation RHFE-750ET R 19 Location Use the adjustment feet so that the appliance is level and not tilted. They are initially installed immediately behind the side louvers but can be mov ed forward for better access in hearth or floor installations. The hearth should not block the applia nce. Cor r ec t Flo or Leve l Ins t allat ion Par tic ...

  • Rinnai RHFE-750ETR - page 20

    20 Rinnai Corporation RHFE-750ETR 2. Assemble and Adjust the Sleeve Lengt h Measure wall thickness through previously drilled 3 1/2 inch (90 mm) hole. The end of the sleeve should prot rude 3/16 - 3/8 inch (5-10 mm) from the outside wall. In the “A” vent kit there are 4 parts provid ed with which to assemble the sleeve. Use the table to determi ...

  • Rinnai RHFE-750ETR - page 21

    Rinnai Corporation RHFE-750ET R 21 3. Attach the sleeve Attach to the inside wall using 3 screws arrangi ng the flange so that the marking “TOP” is at the top. The flange is offset 2° to allow the condensate to drain to the outside. Flue Manifold Installation 4. Install the Terminal Check that the terminal seal is in place. For weatherboard or ...

  • Rinnai RHFE-750ETR - page 22

    22 Rinnai Corporation RHFE-750ETR Extension Kit Installation The exhaust line is connected between t he joint pipe at the rear of the heater and the exhaust port on the flue pipe. Slope the exhaust line 3° to the outside so that any condensate will drain awa y from the appliance. The figures below show two example s of horizontal exhaust line exte ...

  • Rinnai RHFE-750ETR - page 23

    Rinnai Corporation RHFE-750ET R 23 Extension Kit Installation Description FOT-102 FOT-103 FOT-114 FOT-115 Exhaust Pipe (adjustable) 11.4-20.3 in (290-515 mm) 1 Exhaust Pipe (adjustable) 21.0-39.6 in (533-1005 mm) 1 1 Exhaust Pipe 40 in (1016 mm) 1 Air Intake Hose 29.5 in (750 mm) 1 Air Intake Hose 49.2 in (1.25 m) 1 Air Intake Hose 90.6 in (2.3 m) ...

  • Rinnai RHFE-750ETR - page 24

    24 Rinnai Corporation RHFE-750ETR 6. Unscrew the flue acce ss panel held by two screws located inside the top left-han d corner of the appliance. Slide this panel to the right behind the convection fan. Connections 1. Carefully remove the packaged ceramic logs and place in a safe location. 2. To ensure the correct positioning, terminate the gas sup ...

  • Rinnai RHFE-750ETR - page 25

    Rinnai Corporation RHFE-750ET R 25 Connections 9. Remove clamp L and slide the vertical pipe M down into the lower elbow N to remove parts J and K. Separate J and K. 10. Attach pipe J to the flue manifold with clamp and screw. (If using extension pipes, attach pipe J to the extension pipe using pi pe stopper A.) 11. Push the air intake line onto th ...

  • Rinnai RHFE-750ETR - page 26

    26 Rinnai Corporation RHFE-750ETR Final Assembly 1. Remove the two retaining screws that secure the combustion chamber glass panel. 2. Rotate and lift the combustion chamber glass clear of the combustion chamber and place in a safe location. 3. Seat the rear log into the combustion chamber onto its location pins. 4. Seat the left hand middle log on ...

  • Rinnai RHFE-750ETR - page 27

    Rinnai Corporation RHFE-750ET R 27 Air Guide Vanes To move the air flow more to the right or to the left, bend the air guide vanes using o nly light hand pressure. Do not bend repeatedly (no more than 5 times) o r else the vane will break. Install the Front Panel 1. Install the front panel by hooking the top into the body and rotating the bottom to ...

  • Rinnai RHFE-750ETR - page 28

    28 Rinnai Corporation RHFE-750ETR Operating Instructions FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING If you do not follow these instructio ns exactly, a fire or explosion may result causing property damage, pe rsonal injury or loss of life. A. This appliance is equippe d with an ignition device that automatically lights the pilot. Do not try to ...

  • Rinnai RHFE-750ETR - page 29

    Rinnai Corporation RHFE-750ET R 29 Wiring and Schematic Diagrams If any of the original wire as supplied with the appliance must be replace d, it must be replaced with type 18 AWG wire or its equivalent. Label all wires prior to disconnection when servicing controls. Wiring errors can cau se improper and dange rous operation. CAUTION ...

  • Rinnai RHFE-750ETR - page 30

    30 Rinnai Corporation RHFE-750ETR Parts List For replacement parts call Rinn ai at 1-800-621-9419. ...

  • Rinnai RHFE-750ETR - page 31

    Rinnai Corporation RHFE-750ET R 31 Parts List ...

  • Rinnai RHFE-750ETR - page 32

    32 Rinnai Corporation RHFE-750ETR Parts List ...

  • Rinnai RHFE-750ETR - page 33

    Rinnai Corporation RHFE-750ET R 33 Parts List 1 1 10201 PANEL BASE RHFE750ETR 2 2 107 77 FOOT KIT RHFE 3 1 BRACKET COMB CHAMBER SUPPORT RH R750 NON SERVICEABLE PART 4 1 BRACKET COMB CHAMBER SUPPORT LH R750 NON SERVICEABLE PART 5 2 104 58 BRACKET FRONT MOUNT RHFE 6 2 107 51 WHEEL KIT RHFE750/IBOF 7 2 107 78 GLASS RETAINER SPRING KIT RHFE750 8 1 102 ...

  • Rinnai RHFE-750ETR - page 34

    34 Rinnai Corporation RHFE-750ETR Parts List 48 2 10359F BURNER ASSEMBLY BRAY 250 Ø3.0 x 2 NG LEFT AND RIGHT ** 48 1 10359B BURNER ASSEMBLY BRAY 250 Ø6.0 x 2 LPG LEFT ONLY ** 48 1 10359G BURNER ASSEMBLY BRAY 250 Ø6.5 x 2 LPG RIGHT ONLY ** 49 1 10764 PILOT ASSEMBLY RHFE750 50 1 10772 PILOT ELECTRODE KIT RHFE750 INCLUDES DOUBLE ELECTRODE, FLAME RO ...

  • Rinnai RHFE-750ETR - page 35

    Rinnai Corporation RHFE-750ET R 35 Parts List 95 1 10330 HOSE SS 10 530 3/8SAE RHFE750 96 1 10567 VALVE 3/8" SAEM-FLARE 1/2"NPTF 97 1 10797 PCB ASSEMBLY RHFE750 98 1 10768 FLAME ROD KIT RHFE750 CONTAINS 3 x FLAME RODS 99 1 10770 FLAME ROD BRACKET KIT RHFE750 CONT AINS 3 x BRACKETS 100 1 10792 CONVECTION FAN ASSEMBLY RHFE750 US 101 1 10769 ...

  • Rinnai RHFE-750ETR - page 36

    36 Rinnai Corporation RHFE-750ETR Consumer Support W arranty Information Limited W arranty RHFE-750ETR Direct Vent Fireplace What is covered? This Warranty covers any defects in ma terials or workmanshi p, subject to the terms stated below. This Warra nty extends to the original purchaser and subsequent transferees, but only while the product rem a ...

  • Rinnai RHFE-750ETR - page 37

    Rinnai Corporation RHFE-750ET R 37 Limited W arranty - continued How do I get service? You must contact a qualified/authorized servi ce provider fo r the repair of a product under this Warranty. For the name of a qualified/authorized servi ce provider please c ontact your place of purchase, visit the Rinnai website (www.rinnai.u s ), call Rinnai at ...

  • Rinnai RHFE-750ETR - page 38

    38 Rinnai Corporation RHFE-750ETR Notes ...

  • Rinnai RHFE-750ETR - page 39

    Rinnai Corporation RHFE-750ET R 39 Notes ...

  • Rinnai RHFE-750ETR - page 40

    Manufactured by Rinnai New Zealan d LTD 691 Mt Albert Road Royal Oak, Auckland 15237 (Issue B) For information on Rinnai’ s products contact 103 International Drive Peachtree City, GA 30269 Phone: 1-800-621-9419 Fax: 1-888-474-6624 ...

Produzent Rinnai Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Rinnai RHFE-750ETR erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Rinnai
- Bedienungsanleitungen RHFE-750ETR
- Produktkarten Rinnai
- Informationsbroschüren
- oder Energieetiketten Rinnai RHFE-750ETR
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Rinnai RHFE-750ETR.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Rinnai RHFE-750ETR, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Rinnai RHFE-750ETR. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Rinnai RHFE-750ETR ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Rinnai RHFE-750ETR, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Rinnai RHFE-750ETR hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Rinnai RHFE-750ETR verständlich ist.

Eine gänzliche Bedienungsanleitung von Rinnai sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Rinnai RHFE-750ETR bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Rinnai RHFE-750ETR befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Rinnai RHFE-750ETR, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Rinnai RHFE-750ETR - die uns die ersten Schritte während der Nutzung von Rinnai RHFE-750ETR erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Rinnai RHFE-750ETR hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Rinnai RHFE-750ETR im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Rinnai RHFE-750ETR?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Rinnai RHFE-750ETR nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Rinnai RHFE-750ETR hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)