    The W ir eless Connectivi ty Expert 4851 1 W arm Springs Blvd., Su ite 206, Frem ont CA 9453 9 T el : (510) 490-802 4 Fax: (510) 62 3-7268 We b s i t e : http://www .actisys.com/ E-mail: irda- info@act isys.co m ACT-IR100SL and ACT-IR100SL-M User’s Manual (IrDA Intelligent RS232 Adapters) © Copyright 2000- 2002 ACT iSYS Corporation, All Rights R ...

  • ACTiSYS ACT IR100SLM - page 2

    - 1 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 FCC & VCCI Compliance Statement This device c omplies with p art 15 of the FCC Rules. O peration is subj ect to the follo wing t wo conditio ns: (1)T his device m a y not caus e harmf ul inter ferenc e, and (2) this de vice m ust ac cept an y interf erence received, incl ...

  • ACTiSYS ACT IR100SLM - page 3

    - 2 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 T ABLE OF CONTENTS PRECAU TIONS........................................................................................................... 3 1. Featarus.................................................................................................................. 4 2. Ove ...

  • ACTiSYS ACT IR100SLM - page 4

    - 3 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 PRECA UTIONS T o ensure trouble-free operation, please observe the following precautions: Optical communications are easily af fected by external light sources, weak batteries, transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer failure, ...

  • ACTiSYS ACT IR100SLM - page 5

    - 4 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 1. Features Support IrDA standard including: - Ir LAP - IrLM P - T iny TP - I r C O MM - IrOBEX transport Other standards: - IrLP T IrDA baud rate supported: - 9.6kbps - 19.2kbps - 38.4kbps - 57.6kbps - 1 15.2kbps IrDA Primary/Secondary Mode supported: - IR100SL : Secondary ...

  • ACTiSYS ACT IR100SLM - page 6

    - 5 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 Host interface baud rate supported: - 1.2kbps - 2.4kbps - 4.8kbps - 9.6kbps - 19.2kbps - 38.4kbps - 57.6kbps - 1 15.2kbps ...

  • ACTiSYS ACT IR100SLM - page 7

    - 6 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 75L V47 37 IR8200IC IR220V ACF TXDO /RXDI / MODE / RESET /RXD0 /TXD 0 Optic al T ransceiver /TX D1 /RXD1 /RT S1 /CTS1 /DSR1 /DTR1 /CD1 /RI1 /RTS0 /DTR0 /RXDO /TXD I EEPRO M RTS CTS DSR DTR CD RI TXD RXD SEL0 SEL1 SEL2 : : /RT S1 /CTS1 /DSR1 /DTR1 /CD1 /RI1 /TXD /RXD 2. Overv ...

  • ACTiSYS ACT IR100SLM - page 8

    - 7 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 3. A pplicat ions 3.1 Embedded IrDA protocol stack The mandatory IrDA protocol layers, Ir LAP (comply with TEST frame capability requir ement) and IrLMP (including IAS) are handled by ACT-IR100S-L/LM, In addition, Ti nyTP , IrCOMM, IrLPT , IrOBEX transport are all included. ...

  • ACTiSYS ACT IR100SLM - page 9

    - 8 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 I r L M P a n d I A S IrLAP IrLPT or IrCOM M 3- wire r aw IrCOMM 9-wire TinyTP OBEX T rans p ort Tiny TP HOST IrPHY encoder-decoder ( ACT-IR220V A CF ) UART1 UART0 Buffers IrDA T ransceive r RS232 converter ( 75L V737A ) ACT- IR100S-L ACT-IR8200IC -L ...

  • ACTiSYS ACT IR100SLM - page 10

    - 9 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4. Operation Setting, EEPROM, and other optional hardware 4.1 Serial EEPROM There are some special functions i f t he external serial EEPROM installed. The optional serial EEPROM allow users to set ”Host Speed” and “Hardware Flow Control and Connection Control”. The ...

  • ACTiSYS ACT IR100SLM - page 11

    - 10 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.2 Baud Rate Setting Jumpers SEL0-2 and serial EPROM setting s are used to set the hos t interface RXD and TXD data rate. Note that this is independent of the IrDA connection data rat e. Data format is always 8 data bits, no parity , and 1 stop bit. Note that this is compa ...

  • ACTiSYS ACT IR100SLM - page 12

    - 11 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.3 Ignore DSR SEL3 open (SEL3=1) m eans i g n o r e t he ph y sical DSR inpu t, p r e t end t h a t DSR is on. This logical DSR is always used for connection control. The physical DTR is used f or connection indicat ion. SEL3 has no ef fect on DTR. W h e n SEL3 close (SEL3 ...

  • ACTiSYS ACT IR100SLM - page 13

    - 12 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.5 EEPROM Function Disable Jumper SEL7 is use to enable or disable EEPROM f unct ion. If this function disable, IR100S-L/ L M will use SEL0~SEL4 setting only . If this function enable, IR100S-L/LM will use EEPROM setting and jumpers SEL0~SEL4 a re ignored. Note: 1. SEL5 ~ ...

  • ACTiSYS ACT IR100SLM - page 14

    - 13 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.6 On Line Change Host Speed and Hard w are Flow Control/Connection Control The ACT-IR100S-L/LM allowed user to change Host Speed or Hardware Flow Control/Connection Control in run tim e. IRSET can change setting and w rite new value into the EEPROM via IR. COMSET can chan ...

  • ACTiSYS ACT IR100SLM - page 15

    - 14 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.7 RS-232C DTE DB-9P Connector Pin No. Name Descriptions I/O 1 CD Data Carr ier Det ect I 2 RXD Receiver Data I 3 TXD Transmitter Data O 4 DTR Data T erm inal Ready O 5 GND Signal Ground GND 6 DSR Data Set Ready I 7 R TS Request to Send O 8 CTS Clear to Send I 9 RI Ring In ...

  • ACTiSYS ACT IR100SLM - page 16

    - 15 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 5. How to Connect IR100S-L/LM with host Device IR100S-L/LM uses a standard RS232 D TE port to connect with the host. If the host dev ice is a Modem like device and has a RS232 DCE port, then use a "straight cable". That is, connect the signals with the same name f ...

  • ACTiSYS ACT IR100SLM - page 17

    - 16 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 IR100S-L TXD RXD RTS CTS DSR DTR CD RI GND DTE RXD TXD CTS RTS DT R DS R CD RI GND If the host device is a PC like device and has a RS232 DTE port too, then you need to use a "Null Modem" connection betw een the t wo. That is, in/out signal pairs need to be crosse ...

  • ACTiSYS ACT IR100SLM - page 18

    - 17 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 OTHER ACT iSYS IrDA PRODUCTS I (A CT-1 ): IrDA Primary Statio n Pro toco l Stack !" IrLAP, IrLMP, IAS and o ptional T iny TP, IrCOM M, IrM C, IrTr an-P, etc.. !" For PDA, d igita l cam era, handhel d data t erm inal, pal mtop c omputer, sm ar t phone. !" Very ...

  • ACTiSYS ACT IR100SLM - page 19

    - 18 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002  THE FOLLOWING W ARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHT S THAT VARY FROM STATE TO STATE. LIMITED W ARRA NT Y ACTiSYS Corporation warrants to the first consumer purchaser , for a period of 1 y ear from the date of purchase, that this wirele ...

  • ACTiSYS ACT IR100SLM - page 20

    - 19 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002      Copyright 199 5-2001 ACT iSYS Corp. 4851 1 W arm Springs Blvd, Suite 206, Fr em ont, CA 94539, USA T el:+1-510-490-8024 Fax:+1-510- 623-7268 Internet: irda-info@act isys.com W eb Site: http://www .actisys.com Corporation ...

Produzent ACTiSYS Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts ACTiSYS ACT IR100SLM erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen ACTiSYS
- Bedienungsanleitungen ACT IR100SLM
- Produktkarten ACTiSYS
- Informationsbroschüren
- oder Energieetiketten ACTiSYS ACT IR100SLM
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung ACTiSYS ACT IR100SLM.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen ACTiSYS ACT IR100SLM, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen ACTiSYS ACT IR100SLM. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts ACTiSYS ACT IR100SLM ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts ACTiSYS ACT IR100SLM, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von ACTiSYS ACT IR100SLM hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von ACTiSYS ACT IR100SLM verständlich ist.

Eine gänzliche Bedienungsanleitung von ACTiSYS sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von ACTiSYS ACT IR100SLM bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von ACTiSYS ACT IR100SLM befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich ACTiSYS ACT IR100SLM, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts ACTiSYS ACT IR100SLM - die uns die ersten Schritte während der Nutzung von ACTiSYS ACT IR100SLM erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit ACTiSYS ACT IR100SLM hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von ACTiSYS ACT IR100SLM im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich ACTiSYS ACT IR100SLM?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit ACTiSYS ACT IR100SLM nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit ACTiSYS ACT IR100SLM hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)