    CG-1309 REV C FEB 2006 OPERATION & MAINTE NANCE MANUAL UP/DN CONVERTER L-BAND LT-3600 SERIES 1915 Harrison Road Longview, Texas 75604 EXPORT CONTROL WARNING - Do not disclose this document or its contents to non-U.S. Persons, o r transmit this docum ent or its con tents outside th e United States without the written permission of Vertex Communi ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 2

    Integrated L-Band Up/Dn Conve rter LT3600 CG-130 9 Page 2 WARRANTY VertexRSI warrants its products for a peri od of two (2) years from the date of shipment to be free from defects caused by faulty materials or poor workmanship. The terms and conditions of this warranty are as follows • The purchaser must notify VertexRSI pr omptly upon discovery ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 3

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 3 TABLE OF CONTENTS Section 1 General Information ................................................................................................ 6 1.0 Introduction ............................................................................................................... ............... ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 4

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 4 Section 4 Serial Command Set .............................................................................................. 20 4.0 General .................................................................................................................................... 20 4.1 LT-3600 Seria ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 5

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 5 APPENDICES A Technical Manual Revision History ....................................................................................... 26 B CCA Software Revision History ............................................................................................. 26 C Display Panel Softwa re ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 6

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 6 SECTION 1 General Information 1.0 INTRODUCTION This manual contains installation, operation, and maintenance information for th e Integrated L-Band Up/Dn Converter manufactured by VertexRSI, Longview, Tx. Information is organized according to section. Within each section the pages, figures a ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 7

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 7 1.4 SPECIFICATIONS The specifications for the Integrated L-Band Up/Dn Converter are listed in Table 1-1, along with the mechanical dimensions. 1.5 FRONT PANEL All the operating controls and indicators for the Integrated L-Band Up/Dn Converter are located on the front panel. The front panel i ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 8

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 8 1.8 Part Number Configuration The Part Number Selection Chart shows configurati on options that are set at the factory prior to shipment. The voltage output to J4 and J10 may be changed as required by the customer, however this requires removal of the cove r and resetting internal jum per co ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 9

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 9 Table 1-1 Integrated L-Band Specifications UPCONVERTER Input Frequency Range 50 to 90 MHz Input Impedance 50 Ohms Input Level Range -20 to -40 dBm Output Frequency Range 950 to 1525 MHz 950 to 1950 MHz (Optional) Output Impedance 50 Ohms Output Return Loss 18dB Conversion Gain 10 to 30 dB (0 ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 10

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 10 Table 1-1 Integrated L-Band Specifications OPTIONAL INTERNA L REFERENCE Reference Frequency 10.000 MHz Stability (0 to +50 °C) + 2 x 10 -8 Aging per Day + 1 x 10 -9 Output Level (rear panel) + 12 dBm + 2 dB Phase Noise @ 10 Hz -115 dBc/Hz 1 00 Hz -135 dBc/Hz 1 kHz -145 dBc/Hz 1 0 kHz < ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 11

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 11 Table 1-1 Integrated L-Band Specifications INTERFACE AND CONNECT ORS Voltage (auto-ranging) 115/230 VAC + 15% Internal Electronics (Power) 25 watts StarSwitch Interface Connectors (Options) DB-15 (Female) Remote Serial Interface: Standard: RS-422/RS-485 (J7) DB-9 (Male) External SSPB Monito ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 12

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 12 SECTION 2 Installation 2.0 INTRODUCTION This section defines th e installation require- ments by which the Integrated L-Band Up/Dn Converter will meet the published specifications. 2.1 UNPACKING AND INSPE CTION Remove the unit from its shipping container and inspect for any damage sustained ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 13

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 13 2.4.6 External 10 MHz Input (J2) This connector is a BNC female. The male mate (not supplied) should be compatible with the 50-ohm coax used to connect to the system. 2.4.7 SSPB Interface (J6) This connector is a 9-pi n female miniature type “D” connector with standard #4-40 female scre ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 14

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 14 SECTION 3 Operation 3.0 INTRODUCTION The Up/Down Converter can be controlled from the front panel or remotely via a serial bus located on the rear panel of the converter. Various menus are available for EDIT and DISPLAY purposes. See Figure 3-2 for a listing of the menus. Section 4 gives a ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 15

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 15 Figure 3-2 Menu Listing RefOsc: OK Ofst:127 Slope Factor: 0 dB Unit Address: xx xx = 422 Mode Brd SN 1234 20/12/04 S/W:v7.70 Temp: 32 C Front Panel SW v 5.20 FP Alarm Tone: On UC 1200.000 +25.0 dB DC 1300.000 +35.0 dB UC: Ovr State: On DC: Low State: Muted UC Lvl: +1 dBm DC Lvl: -25 dBm SSP ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 16

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 16 Figure 3-3 Satellite Memory UC 0950.000 +10.0 dB DC 1525.000 +30.0 dB HIT ANY KEY (0-9) Example (KEY 0) EDIT ENT ENTER KEY RECALLS MEMORY TO ACTIVE UC0 1200.000 +20.0 dB DC0 1200.000 +30.0 dB ESCAPES TO ADJACENT MENU WITHOUT RECALL CONFIRM AND STORE CHANGE TO EACH FIELD AND LEAVE EDIT MODE ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 17

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 17 3.1 StarSwitch Operation The LT3600 UP/DOWN Converter may be used in conjunction with the StarSwitch to provide redundancy switch over operations if configured as StarSwitch Ready. The following modes of operation may be selected. 3.1.1 Auto Mode Upon reaching the StarSwitch Menu the inform ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 18

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 18 3.1.4 Backup Converter Operation The Backup Converter must be programmed to store all of the Converter Fre quencies and Gains in the system, in its Satellite Memory Locations, correspondi ng to the Converter Num ber (1 to 8) labeled on the StarSwitch Interface cables. Figure 3-7 show s the ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 19

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 19 3.2 Front Panel Alarm Settings Menu Page Acti ve Modes Mask (Default) Comment 1) Starswitch Auto ON STBY Auto Must select "Auto" Mode when Starswitch is not present. Forces summary alarm to OFF (see Stars witch operation). Forces summary alarm to ON (see Sta rswitch operation). 2) ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 20

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 20 SECTION 4 Serial Command Set 4.0 GENERAL The standard Up/Dn Converter is controlled via a rear panel seri al link (RS-422/485)(Reconfigurable to RS-232). With the front panel control, a user can operate the L-Band Up/Dn Converter from its front panel as well as from the serial link. This se ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 21

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 21 4.3 COMMANDS 4.3.1 Set UP/Converter Frequency {aaC1xxxxx} Where xxxx(x) = First 4 numeric data characters Range: 0950 to 1525 (MHz) for Std. Band units Range: 0950 to 1950 (MHz) for Extended Band units Where (xxxx)x = Fifth character is fractional MHz as follows 0 = 0.0 MHz 1 = +0.125 MHz 2 ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 22

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 22 4.3.7 DOWN/Converter (LNB) Spectrum Control {aaC7x} Where x = 0 for Non-Inverting spectrum and x = 1 for Inverting spectrum 4.3.8 UP/Converter Spectrum Control {aaC7TXz} Where z = 0 for Non-Inverting spectrum and z = 1 for Inverting spectrum 4.3.9 SSPB Band Control {aaC8x} Where x = 0 for S ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 23

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 23 4.4 STATUS REQUESTS 4.4.1 Command Status {aaS1} Returns: {aaS1bbbbccccddddeeeefffUL} Where bbbb = Up/Converter Frequency (as above) cccc = Down/Converter Frequency (as above) dddd = Up/Converter Gain eeee = Down/Converter Gain fff = Ref. Osc. Offset U = 0 for Non-Inverting Up/Converter, 1 f ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 24

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 24 4.4.4 L-Band Status {aaS3} Returns: {S3bbCddTReeN} Where: bb = 2 Chars., LNB current Detection Range: 00 to 99 ( 0 - 990 mA) C = 1 Character, SSPB Band Control Range: 0 = low band, 1 = high band dd = 2 Characters, SSPB Gain Range: –8 to –0 or ++ (dB) ++ = Full On T = 1 Character, Up/Con ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 25

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 25 4.4.9 Query Card Type {aaZ} Returns: {aaZxx} Where: xx = L-Band Card Type (1 – 8) 10 = 70 MHz IF, Std. Band Unit (SBU) 20 = 140 MHz IF, SBU 11 = 70 MHz IF, Ext Band Unit (EBU) 21 = 140 MHz IF, EBU 50 = 70 MHz IF, SBU with Inv. Up/Converter Spectrum 60 = 140 MHz IF, SBU with Inv. Up/Conver ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 26

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 26 Appendix A Manual Revision Hist ory C – Add Starsw menu M. Neely 2-03-05 D. Snyder 2-03-05 6323 B – Add Satellite Menu Info M. Neel y 10-14-05 D. Snyder 10-5-05 6129 A – Gain signs M. Neely 8-15-05 D. Snyder 8-15-05 6020 - Original Release M. Neely 11-5-04 D. Snyder 11-5-04 5442 Rev. ...

Produzent General Dynamics Kategorie Network Hardware

Dokumente, die wir vom Produzenten des Geräts General Dynamics UP/DN CONVERTER L-BAND erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen General Dynamics
- Bedienungsanleitungen UP/DN CONVERTER L-BAND
- Produktkarten General Dynamics
- Informationsbroschüren
- oder Energieetiketten General Dynamics UP/DN CONVERTER L-BAND
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung General Dynamics UP/DN CONVERTER L-BAND.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen General Dynamics UP/DN CONVERTER L-BAND, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen General Dynamics UP/DN CONVERTER L-BAND. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts General Dynamics UP/DN CONVERTER L-BAND ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts General Dynamics UP/DN CONVERTER L-BAND, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von General Dynamics UP/DN CONVERTER L-BAND hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von General Dynamics UP/DN CONVERTER L-BAND verständlich ist.

Eine gänzliche Bedienungsanleitung von General Dynamics sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von General Dynamics UP/DN CONVERTER L-BAND bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von General Dynamics UP/DN CONVERTER L-BAND befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich General Dynamics UP/DN CONVERTER L-BAND, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts General Dynamics UP/DN CONVERTER L-BAND - die uns die ersten Schritte während der Nutzung von General Dynamics UP/DN CONVERTER L-BAND erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit General Dynamics UP/DN CONVERTER L-BAND hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von General Dynamics UP/DN CONVERTER L-BAND im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich General Dynamics UP/DN CONVERTER L-BAND?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit General Dynamics UP/DN CONVERTER L-BAND nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit General Dynamics UP/DN CONVERTER L-BAND hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)