Bedienungsanleitung York D2HE/D2HG060

28 Seiten 3.38 mb
Download

Zur Seite of 28

Summary
  • York D2HE/D2HG060 - page 1

    036- 21216-003- A-0204 FOR DISTRI BUTION USE ONLY - NOT TO B E USED A T POINT OF RETAIL S ALE TECHNICAL GUIDE SUNLINE UL TRA™ SINGLE P ACKAGE AIR-COOLED AIR CONDITIONERS 3, 4 AND 5 NOMINAL TON D1HE/ D1HG036 , 048 a nd D2HE /D2HG06 0 12.2 THROUGH 13.2 SEER ® DHG MO DEL SH OW N FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL YORK’ s S unline U ltra p ack ...

  • York D2HE/D2HG060 - page 2

    036-212 16-003- A-0204 2 Unitary Products G roup T ABLE OF CONTENTS DESCRIPTIO N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FACTORY-INSTALLED OPTION . . . . . . . . . . . . . . . 4 FIELD-INSTALLED ACCE SSORIES . . . . . . . . . . . . . 4 MECHANICAL SP ECIF ...

  • York D2HE/D2HG060 - page 3

    036-2121 6-003-A-0 204 Unitary Products G roup 3 DESCRIPTION YORK Sunli ne Ultra unit s are high effi cienc y , convertibl e, sin - gle p acka ge air con dition ers with a com mon cab inet a nd a common roof curb for the 3, 4 and 5 ton sizes . The unit s were design ed for re siden tial, l ight c ommerci al and comm ercial applic ations . They c an ...

  • York D2HE/D2HG060 - page 4

    036-212 16-003- A-0204 4 Unitary Products G roup troubles hootin g witho ut af fecting the norm al sys tem operat - ing pressu res. AIR FIL TERS - Units a re ship ped with 1" throwaway fi lters. The unit filter racks can acc ommodate 1" or 2" filt ers with out any m odifi c ation s F ACT OR Y -INST ALLED OPTION ECONOMIZ ERS: Unit s e ...

  • York D2HE/D2HG060 - page 5

    036-2121 6-003-A-0 204 Unitary Products G roup 5 W ALL TH ERMOST A T - The unit s are de signe d to operate with 2 4-volt ele ctroni c and electro -mech anica l thermos tat s. All unit s can operate with sin gle st age h eat / sin gle st age cool thermos tats - with o r withou t the econ omizer . . FIGURE 1 - SUNLINE UL TRA CUT A W A Y (Model DHG g ...

  • York D2HE/D2HG060 - page 6

    036-212 16-003- A-0204 6 Unitary Products G roup T ABLE 2: CAP ACITY RA TINGS - COOLING / GAS HEA TING MODEL ARI RA T INGS 1 GAS HEA T CAP ACITY COOLING CAP ACIT Y 80 / 67-95 ° F SOUND RA TI NG 2 (dBel s) INPUT (MBH) DOE OUTPUT (MBH) AFUE 3 (%) S.S.E. 4 (%) S.E. 5 (%) TEMP . RIS E (°F) GAS LINE SIZE (in. O .D.) MBH SEER 6 EER 7 DHG036N 040 42. 5 ...

  • York D2HE/D2HG060 - page 7

    036-2121 6-003-A-0 204 Unitary Products G roup 7 T ABLE 5: COOLING CAP ACITIES - MODELS DHE/DHG 0 36 - 85°F - 9 5ºF AIR ON EV APORA T OR COIL TEMPERA TURE O F AIR ON CONDENSER COIL 85°F TOT AL CAP . 1 MBH POWER INPUT 2 SENSIBLE CAP ACITY 3 ENTERING DR Y BULB, °F CFM WB °F 86 83 80 77 74 71 68 1500 72 55.2 3.18 35.2 30.7 26 .2 21.8 17.3 #N/A #N ...

  • York D2HE/D2HG060 - page 8

    036-212 16-003- A-0204 8 Unitary Products G roup T ABLE 6: COOLING CAP ACITIES - MODE LS DHE/DHG 036 - 105°F - 1 15ºF AIR ON EV APOR A TOR COIL TEMPERA T URE OF AIR ON CONDENSER CO IL 105°F TOT A L CAP . 1 MBH POWER INPU T 2 SENSIBLE CAP ACITY 3 ENTERING DRY BULB, °F CFM WB °F 86 83 80 77 74 71 68 1500 72 47.6 3.65 32.3 27.8 23.3 18.9 14.4 #N/ ...

  • York D2HE/D2HG060 - page 9

    036-2121 6-003-A-0 204 Unitary Products G roup 9 T ABLE 7: COOLING CAP ACITI ES - MODELS D HE/DHG048 AIR ON EV APORA T OR COIL TEMPERA TURE O F AIR ON CONDENSER COIL 85°F 95 °F TOT A L CAP . 1 MBH POWER INPUT 2 SENSIBLE CAP ACITY 3 TOT AL CAP . 1 MBH POW ER INP UT 2 SENSIBLE CAP ACITY 3 ENTERING DRY BULB, °F ENTERING DRY BULB, °F CFM WB °F 86 ...

  • York D2HE/D2HG060 - page 10

    036-212 16-003- A-0204 10 Unitary Products G roup T ABLE 8: COOLING CAP ACITIES - MODELS DHE/DH G060 AIR ON EV APORA TOR COIL TEMPERA T URE OF AIR ON CON DENSER COIL 85°F 95°F TO T AL CAP . 1 MBH POWER INPUT 2 SENSIBLE CAP ACITY 3 TO T AL CAP . 1 MBH POWER INPUT 2 SENSIBLE CAP ACITY 3 ENTERING DRY BULB, °F ENTERING DRY BULB, °F CFM WB °F 86 83 ...

  • York D2HE/D2HG060 - page 11

    036-2121 6-003-A-0 204 Unitary Products G roup 11 T ABLE 9: SUPPL Y AIR BLOWER P ERFORMANCE -DHE/D HG036 1 1. For 208 Volt s multiply values by 0.95. MODE L DHE/DHG AIR FLOW CFM A V AILABLE EXTERNAL ST A TIC PRESSURE - IWG 2 2. Includes allowances for a wet evaporat or coil, 1” filters, and the heat exc hangers. Refer to T able 12 for resistance ...

  • York D2HE/D2HG060 - page 12

    036-212 16-003- A-0204 12 Unitary Products G roup T ABLE 10: SUPP L Y AIR BLOW ER PERFOR MANCE DHE/DHG048 1 (4 TON GAS HEA T MOD ELS) UNIT SIZE (MBH AIR FLOW CFM A V AILABLE EXTERNAL ST A TIC PRESSURE - IWG 2 0.20 0. 30 0.40 0.50 0.6 0 0.70 0.80 RPM Wa t t s RPM Wa t ts RPM Wa t ts RPM Wa t ts RPM Wat ts RPM Wa t ts RPM Wa t ts 048 2000 843 860 88 ...

  • York D2HE/D2HG060 - page 13

    036-2121 6-003-A-0 204 Unitary Products G roup 13 T ABLE 1 1: SUP PL Y AIR BLOWER PE RFORMANCE DHE/DHG060 1 (5 TON GAS HEA T MODELS) UNIT SIZE (MBH) AIR FLOW CFM A V AILABLE EXTERNAL ST A TIC PRESSURE - IWG 2 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Wat ts RPM Wa t ts RPM Wa t t s RPM Wat ts RPM Wat ts RPM Wa t ts RPM Wat ts 060 2500 1059 1560 1077 1 ...

  • York D2HE/D2HG060 - page 14

    036-212 16-003- A-0204 14 Unitary Products G roup T ABLE 13: MOTOR AND DRIVE DA T A - BE L T -DRIVE BLOWE R MODEL BLOWER RANGE (RPM) MOTOR 1 ADJUST ABLE MOTOR PULL EY FIXED BLOWER PULLEY BEL T HP RPM FRAME SIZE SER VICE F ACTOR PITCH DIA . (in.) BORE (in.) PITCH DIA. (in.) BORE (in.) PITCH LENGHT (in. ) DESIG- NA TION DHE/DHG 036 780 - 1120 1 1/ 2 ...

  • York D2HE/D2HG060 - page 15

    036-2121 6-003-A-0 204 Unitary Products G roup 15 T ABLE 15: EL ECTRICAL DA T A - COOLING /ELEC TRIC HEA T DHE 036 & 04 8 MODEL DHE POWER SUPP L Y HEA TER ACCESSOR Y MODEL NUMBER SUPPL Y AIR BLOWER MOT OR FLA ELECTRIC HEA TERS TOT A L UNIT AMP ACITY AMPS MAX. FUSE SIZE 1 AMPS MAX. SIZE HACR 2 AMPS kW ST AGES TO TAL AMPS 036 208-3-6 0 2CE045 005 ...

  • York D2HE/D2HG060 - page 16

    036-212 16-003- A-0204 16 Unitary Products G roup T ABLE 18: ELECTRICAL DA T A - COOLING/ELEC TRIC HEA T DHE060 MODEL DHE POWER SUPPL Y HEA TER ACCESSOR Y MODEL NUMBER SUPPL Y AIR BLOWER MOTO R FLA ELECTRIC HEA TERS TOT AL UNIT AMP ACITY AMPS MAX. FUSE SIZE 1 AMPS MAX. SIZE HACR 2 AMPS kW ST AGES TO T AL AMPS 060 208-3-60 2CE04500 525 3 6.0 4.0 1 1 ...

  • York D2HE/D2HG060 - page 17

    036-2121 6-003-A-0 204 Unitary Products G roup 17 FIGURE 4 - CONTROL WI RING SINGLE S T AGE FIGURE 5 - CONTROL WIRING COOLING/HEA T - ING R H R C Y W G R Y 1 W 1 B G A D D J U M P E R T H E R M O S T A T 1 T E R M I N A L S U N I T T E R M I N A L S T R I P T B 1 2 4 V O L T T R A N S F O R M E R 1 E L E C T R O N I C P R O G R A M M A B L E T H E ...

  • York D2HE/D2HG060 - page 18

    036-212 16-003- A-0204 18 Unitary Products G roup NOTE: Unit s and duc twork of D HE model s are ap proved for zero clea ranc e to co mbus tib le m ater ials w hen equippe d wit h electric heate rs FIGURE 7 - DHE UNIT DIMEN SIONS T ABLE 19: UTILITIES ENTRY DA T A HOLE KNOCKOUT SIZE (DIA.) USED FOR A 7/8” 1 Co ntrol Wir ing (S ide or Bottom) 2 B 2 ...

  • York D2HE/D2HG060 - page 19

    036-2121 6-003-A-0 204 Unitary Products G roup 19 NOTE: DHG m odes must be provi ded a 1” cl earance betwee n any com busti ble ma terial and the sup ply air duct work for a dist anc e of 2 f eet from the unit. The produc ts of combustio n must no t be allowed to accumu - late w ith a conf ined s pa ce and rec ircul ate. Loca te uni t so th at th ...

  • York D2HE/D2HG060 - page 20

    036-212 16-003- A-0204 20 Unitary Products G roup Duct c overs - un its are shipp ed wi th all air du ct ope nings cov - ered. For side duct applicati ons: • Remov e and discard the su pply and retu rn air duct cov ers. • Conne ct duc twork to duct flan ges on the rear of the un it. For bottom duct appli cations: • rem ove the sid e su ppl y ...

  • York D2HE/D2HG060 - page 21

    036-2121 6-003-A-0 204 Unitary Products G roup 21 FIGURE 12 - DET AIL “B” UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAM PER RAINHOOD 2 7 - 1 / 2 7 - 1 / 4 2 7 - 1 / 2 1 9 - 1 / 8 " A " 4 4 - 7 / 8 4 - 3 / 8 3 - 1 / 2 8 - 1 / 4 1 0 - 1 / 4 L . H . E N D V I E W R E A R V I E W D I M E N S I O N " A " F I X E D O U T D O O R A I R ...

  • York D2HE/D2HG060 - page 22

    036-212 16-003- A-0204 22 Unitary Products G roup FIGURE 14 - ROOF CURB DIMENSIONS DHE/DHG 3 , 4 & 5 TON FIGURE 15 - CENTER OF GR A VITY AND CORNER W EIGHTS 8 2 - 1 / 4 1 9 - 3 / 4 4 4 - 7 / 8 4 0 - 3 / 4 C O R N E R " A " C O R N E R " D " C O R N E R " B " C O R N E R " C " C O N D E N S E R C O I L E N ...

  • York D2HE/D2HG060 - page 23

    036-2121 6-003-A-0 204 Unitary Products G roup 23 FIGURE 16 - TYPICAL APPLICA TIONS ROOF JACK INST ALLA TION ROOF CURB INST ALLA TION SLAB ON GR OUN D INST ALLA TION FIGURE 17 - TYPICAL ROOF-T OP INST ALLA TION (DHG) ...

  • York D2HE/D2HG060 - page 24

    036-212 16-003- A-0204 24 Unitary Products G roup MECHANICAL SP ECIFICA TIONS GENERAL DESC RIPTION Single p ackaged out door moun ted roo ftop with bu ilt in field convert ible d uct conn ection s for v ertical d ischarge/ return a ir or hor izo ntal di scha rg e/re turn air conf igur ati on. C ool ing per - formanc e sha ll be rat ed in acco rdanc ...

  • York D2HE/D2HG060 - page 25

    036-2121 6-003-A-0 204 Unitary Products G roup 25 b. Unit sh all inc orporat e a lock-ou t circu it which p ro - vides res et cap abili ty at the spac e thermo sta t, should any of the foll owing s tan dard sa fety de vice s trip and shut o ff c ompress or: I.AUTO RESET - Compressor o ver te mperature, ov er current. II.Loss -of-char ge/low-p ressu ...

  • York D2HE/D2HG060 - page 26

    036-212 16-003- A-0204 26 Unitary Products G roup ...

  • York D2HE/D2HG060 - page 27

    036-2121 6-003-A-0 204 Unitary Products G roup 27 ...

  • York D2HE/D2HG060 - page 28

    Subject to change without notic e. Printed i n U.S.A. 036-212 16-003 -A-0204 Copyri ght © 2004 by Uni tary Prod ucts Gro up. All rights res erved. Supersedes : 036-2 1216-002 (0601) Unit ary 5005 Norma n Product s Y ork O K Group Drive 73069 ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York D2HE/D2HG060 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen D2HE/D2HG060
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York D2HE/D2HG060
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York D2HE/D2HG060.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York D2HE/D2HG060, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York D2HE/D2HG060. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York D2HE/D2HG060 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York D2HE/D2HG060, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York D2HE/D2HG060 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York D2HE/D2HG060 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York D2HE/D2HG060 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York D2HE/D2HG060 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York D2HE/D2HG060, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York D2HE/D2HG060 - die uns die ersten Schritte während der Nutzung von York D2HE/D2HG060 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York D2HE/D2HG060 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York D2HE/D2HG060 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York D2HE/D2HG060?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York D2HE/D2HG060 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York D2HE/D2HG060 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)