Bedienungsanleitung Heatcraft Refrigeration Products BN-LOPTB

20 Seiten 3.08 mb
Download

Zur Seite of 20

Summary
  • Heatcraft Refrigeration Products BN-LOPTB - page 1

    L O W P R O FI L E U N I T CO O L E R S T echnical Gui de Model s AD T | A ir Defr ost • L ET /L LE | E lec tr ic Defr ost • HGT | H ot Ga s Defro st www .thecoldstandard.com BNL OPTB April 2008 Replaces BN-L OPTB, August 2004 ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 2

    2 Nomenclature ......................................................................................................................................................................................................... 2 F eatures & Benets ......................................................................................................... ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 3

    3 Features & Benefits Cabinet Minimal height of the low profile series makes it ideal for lo w ceiling coolers Cabinet design f eatures front access panels on each side f or easy access to electrical and refrigeration components All electrical components factor y wired to terminal board and iden tified, making it easy to field wire the unit Sw ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 4

    4 Performance Data Model AD T Air Defrost | 60 Hz Model Capacity F an Data 10°F TD 25°F SST 6°C TD -4°C SST No. CFM m 3 H BTUH W att s AD T040 4,000 1,170 1 730 1,240 AD T052 5,200 1,520 1 700 1,189 AD T065 6,500 1,900 1 650 1,104 AD T070 7,000 2,050 2 1,460 2,481 AD T090 9,000 2,640 2 1,400 2,379 AD T104 10,400 3,050 2 1,400 2,379 AD T120 12,0 ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 5

    5 Model AD T Air Defrost | 50 Hz Model HP PSC Motor EC Motor 110/1/50 220/1/50 380/1/50 110/1/50 220/1/50 Amp s Wat ts Am ps Wat ts A mp s Watt s Amp s Wat ts Am ps Wat ts AD T040 1/15 1.0 68 0.5 65 0.4 82 0.9 57 0.5 59 AD T052 1/15 1.0 68 0.5 65 0.4 82 0.9 57 0.5 59 AD T065 1/15 1.0 68 0.5 65 0.4 82 0.9 57 0.5 59 AD T070 1/15 2.0 136 1.0 130 0.8 1 ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 6

    6 Model LET/LLE Elec tric Defrost | 60 Hz Model Capacity F an Data 10°F TD -20°F SST 6°C TD -29°C SST No. CF M m 3 H BTUH W att s 6 Fins P er Inch LET035 3,500 1,025 1 700 1,189 LET040 4,000 1,170 1 700 1,189 LET047 4,700 1,380 1 650 1,104 LET065 6,500 1,900 2 1,400 2,379 LET075 7,500 2,200 2 1,300 2,209 LET090 9,000 2,640 2 1,300 2,209 LET120 ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 7

    7 Specifications Model LET/LLE Elec tric Defrost | 60 Hz Model HP Shaded P ole Motor PSC, PSC- TE Motor EC Motor Defrost Heaters 208-230/1/60 208-230/1/60 460/1/60 208-230/1/60 W atts 230/1/60 230/3/60 460/1/60 T otal Amps Am ps Wat t s Amp s Wat ts A mp s Wat ts A mp s Watt s 6 Fins P er Inch LET035 1/15 1.0 122 0.5 91 0.4 117 0.5 59 900 3.9 2.3 ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 8

    8 Performance Data Model HGT Hot Gas Defrost | 60 Hz Model Capacity F an Data 10°F TD -20°F SST 6°C TD -29°C SST No. CF M m 3 H BTUH W att s 6 Fins P er Inch HGT035 3,500 1,025 1 700 1,189 HGT040 4,000 1,170 1 700 1,189 HGT047 4,700 1,380 1 650 1,104 HGT065 6,500 1,900 2 1,400 2,379 HGT075 7,500 2,200 2 1,300 2,209 HGT090 9,000 2,640 2 1,300 2, ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 9

    9 Specifications Model HGT Hot Gas Defrost | 60 Hz Model HP Shaded P ole Motor PSC, PSC- TE Motor EC Motor Drain Pan H eaters * 115/1/60 208- 230/1/60 115/1/60 208- 230/1/60 460/1/60 115/1/60 208- 230/1/60 W atts 115/1/60 230/1/60 460/1/60 T otal Amps Am ps Wat t s Amp s Wat ts A mp s Wat ts A mp s Watt s Am ps Wat t s Am ps Wat t s Am ps Wat t s ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 10

    10 Physical Data Model AD T Air Defrost Model No . of F ans Connections (in.) Appro x. Net Wt. Coil Inlet OD Suction ID External Equalizer OD Drain MPT lbs. kg AD T040 1 1/2 5/8 1/4 3/4 28 13 AD T052 1 1/2 5/8 1/4 3/4 31 15 AD T065 1 1/2 7/8 1/4 3/4 34 16 AD T070 2 1/2 7/8 1/4 3/4 45 21 AD T090 2 1/2 7/8 1/4 3/4 48 22 AD T104 2 1/2 7/8 1/4 3/4 49 2 ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 11

    11 The standard design f or the Bohn Low P role Evaporator incorpor ates a hot gas loop in the drain pan. Utilizing a hot gas loop is ideal for hot gas defrost applica tions where high temperature gas can be maintained t o defrost both the evaporator drain pan and coil. F or applications where cooler (lower) t emperature hot gas is used for defr ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 12

    12 Dimensional Data Dimensional Data F or All Models Air Defrost Model Electric and Hot Gas Defrost Model No . of F ans Dimensions A B C D 6 FPI 6 FPI 4 FPI in. mm in. mm in. mm in. mm 040 035 - 1 29.50 749.3 17.25 438.1 - - - - 052 040 - 1 29.50 749.3 17.25 438.1 - - - - 065 047 041 1 29.50 749.3 17.25 438.1 - - - - 070 - - 2 45.50 1,155.7 33.25 8 ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 13

    13 The hot gas unit coolers can be used in rev erse c ycle hot gas defrost sy stems using multiple evaporators connected to one condensing unit. Generally , not more than one -third of the system defr osts at one time. During the reverse cycle defrost, the r eversing valve; located in the compr essor discharge line, diverts hot gas through the suct ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 14

    14 In the refrigeration cycle, the thermostatic expansion valve bypass assembly check valv e only allows refrigerant ow through the thermostatic expansion valv e and into the evaporator c oil. As the refrigerant vapor exits the c oil at the suction line, the check valve of the drain pan loop check valv e assembly prevents the r efrigerant vapor ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 15

    15 The hot gas defrost unit coolers c onforms to the standard 3-pipe hot gas system using a check valve assembly , an elec trical control t o terminate the defrost, and a hot gas solenoid valv e. The check valve assembly transports the hot gas between the drain pan loop and the sideport distributor of the coil. The check valve assembly kit is avail ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 16

    16 Cabinet C omponents Part # Description No . F ans 40480101 Drain P an Air & Hot Gas Defrost 1 40480201 Drain P an Air & Hot Gas Defrost 2 40480301 Drain P an Air & Hot Gas Defrost 3 40480401 Drain P an Air & Hot Gas Defrost 4 40480501 Drain P an Air & Hot Gas Defrost 5 40480601 Drain P an Air & Hot Gas Defrost 6 40480103 ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 17

    17 Standard Nozzle Selection Model AD T Air Defrost Model No . of F ans Distributor T ube (in.) No . of Circuits R-404A R-22 OD Length ADT040 1 3/16 15 1 - - ADT052 1 3/16 15 1 - - ADT065 1 3/16 15 2 L-1/2 L -1/3 ADT070 2 3/16 15 2 L-1/2 L -1/3 ADT090 2 3/16 15 3 L-3/4 L -1/2 ADT104 2 3/16 15 3 L-3/4 L -1/2 ADT120 2 3/16 15 3 L -1 L-3/4 ADT130 2 3/ ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 18

    18 Notes ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 19

    19 Notes ...

  • Heatcraft Refrigeration Products BN-LOPTB - page 20

    A Brand of Heat craft Refrigeration Products LL C 2175 W est Park Place Blv d. • Stone Mountain, GA • 30087 800.537.7775 • F AX 770.465.5990 ww w .thecoldstandard .com F or more information on Bohn refrigeration pr oducts, contact your sales repr esentative or visit us at www.thec oldstandard.com. Since product improvement is a c ontinuing e? ...

Produzent Heatcraft Refrigeration Products Kategorie Fan

Dokumente, die wir vom Produzenten des Geräts Heatcraft Refrigeration Products BN-LOPTB erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Heatcraft Refrigeration Products
- Bedienungsanleitungen BN-LOPTB
- Produktkarten Heatcraft Refrigeration Products
- Informationsbroschüren
- oder Energieetiketten Heatcraft Refrigeration Products BN-LOPTB
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Heatcraft Refrigeration Products BN-LOPTB.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Heatcraft Refrigeration Products BN-LOPTB, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Heatcraft Refrigeration Products BN-LOPTB. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Heatcraft Refrigeration Products BN-LOPTB ansehen.

Die komplette Bedienungsanleitung des Geräts Heatcraft Refrigeration Products BN-LOPTB, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Heatcraft Refrigeration Products BN-LOPTB hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Heatcraft Refrigeration Products BN-LOPTB verständlich ist.

Eine gänzliche Bedienungsanleitung von Heatcraft Refrigeration Products sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Heatcraft Refrigeration Products BN-LOPTB bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Heatcraft Refrigeration Products BN-LOPTB befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Heatcraft Refrigeration Products BN-LOPTB, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Heatcraft Refrigeration Products BN-LOPTB - die uns die ersten Schritte während der Nutzung von Heatcraft Refrigeration Products BN-LOPTB erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Heatcraft Refrigeration Products BN-LOPTB hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Heatcraft Refrigeration Products BN-LOPTB im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Heatcraft Refrigeration Products BN-LOPTB?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Heatcraft Refrigeration Products BN-LOPTB nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Heatcraft Refrigeration Products BN-LOPTB hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)