Bedienungsanleitung Server Technology C-16HF1-C20

12 Seiten 0.77 mb
Download

Zur Seite of 12

Summary
  • Server Technology C-16HF1-C20 - page 1

    © 2006-2007 Server Techn ology, Inc. All rights reserved. Rack-Mount Fail-Safe Transfer Switch Installation and Operations Manual • C-8HFx • C -1 6 HFx ...

  • Server Technology C-16HF1-C20 - page 2

    Instructions This symbol is intended to alert the user to th e presence of important operating and maintenance (servicing) instructio ns in the literature accompanying the appliance. Dangerous Voltage This symbol is intended to alert the user to th e presence of un-insulat ed dangerous voltage within the product’s enclosure that may be of suffici ...

  • Server Technology C-16HF1-C20 - page 3

    Table of Contents C HAPTER 1: I NTRODUCT ION 4 Quick Start Guide ............................................................................................................................. 4 Technical Support ............................................................................................................................4 Equipment Ove ...

  • Server Technology C-16HF1-C20 - page 4

    Chapter 1: Introduction Quick Start Guide The following instructions will help you quickly install and configure your Rack-Mount Fail-Safe Transfer Switch for use on your network. For detailed information on each step, go to the page number listed to the right. 1. Mount the Rack-Mount Fail -Safe Transf er Sw itch ................................... ...

  • Server Technology C-16HF1-C20 - page 5

    Equipment Overview 1. The Voltage Selector switch configures the Rack-Mount Fail- Safe Transfer Switch for the installed operational voltage. NOTE: This configures the brownou t/over -voltage switching points. 2. The power inlets connect the Rack-Mount Fail-Safe Transfer Switch to the electrical power sources. 3. LEDs display the input feeds power ...

  • Server Technology C-16HF1-C20 - page 6

    Chapter 2: Installation Before installing your Rack-Mount Fail-Safe Transfer Switch, refer to the following lists to ensure that you have all the items shipped with the unit as well as all other items required for proper installation. Standard Accessories • Mounting hardware: Two removable flanges with M4 screws. • Outlet retention clips (208-2 ...

  • Server Technology C-16HF1-C20 - page 7

    Installing the Power I nput Retention Bracket For units with a total maximum output <30A, it may be necessary to install the power input retention bracket prior to mounting the unit within the rack. To install the power input retention bracket: 1. Remove the two screws attaching the IEC 60320 C19 inlet to the enclosure. 2. Assemble and attach th ...

  • Server Technology C-16HF1-C20 - page 8

    8 • Operations Rack-Mount Fail-safe Transfer Switch Installation and Operations Manual Chapter 3: Operations Modes of Operation The Sentry Rack-Mount Fail-Safe Transfer Switch is designed to operate in the following modes: • Normal Infeed A provides power to branches A1 & A2 and Infeed B provides power to branches B1 & B2. Each infeed i ...

  • Server Technology C-16HF1-C20 - page 9

    Chapter 4: Appendices Appendix A: Techni cal Specifications Domestic Models Model Rated Voltage Input Cordset a nd Plug (10’) Outlets C-8HF2-C203 208-240V, 50/60Hz IEC 60320 C20 1 8 IEC 60320/C19 C-8HF2-L303 208-240V, 50/60Hz 2 x NEMA L6-30P, 30A/208V Locking 8 IEC 60320/C19 C-16HF1-C20 100-120V, 50/60Hz IEC 60320 C20 1 16 NEMA 5-20R C-16HF1-L30 ...

  • Server Technology C-16HF1-C20 - page 10

    Regulatory Compliance Product Safety Units have been safety tested and certified to the following stan dards: • USA/Canada UL 60950:2003 and CAN/CSA 22.2 No. 60950-1-03 • European Union EN60950-1:2001 This product is also designed for Norwegian IT pow er system with phase-to phase voltage 230V. USA Notification Note: This equipment has been tes ...

  • Server Technology C-16HF1-C20 - page 11

    Appendix B: Warranty, Product Registration and Support Warranty For Server Technology Warranty information, please see our website. Product Registration Registration is your key to special offers a nd services reserved for Registered Users. • Excellent Technical Support Services • Special Update and Upgrade Programs • Warranty Protection • ...

  • Server Technology C-16HF1-C20 - page 12

    Server Technology HEADQUAR TERS – NOR TH AMERIC A EMEA APAC Server Technology, Inc. Server Technology Intl Server Technology, Inc. 1040 Sandhill Drive Sienna Court Singapore Reno, NV 8952 1 The Broadway +65 (0) 6829 7008 Tel United States Maidenhead +65 (0) 6234 4574 Fa x +1.775.284.2000 Tel Berkshire salesint@serverte ch.com +1.775.284.2065 Fax ...

Produzent Server Technology Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts Server Technology C-16HF1-C20 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Server Technology
- Bedienungsanleitungen C-16HF1-C20
- Produktkarten Server Technology
- Informationsbroschüren
- oder Energieetiketten Server Technology C-16HF1-C20
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Server Technology C-16HF1-C20.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Server Technology C-16HF1-C20, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Server Technology C-16HF1-C20. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Server Technology C-16HF1-C20 ansehen.

Die komplette Bedienungsanleitung des Geräts Server Technology C-16HF1-C20, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Server Technology C-16HF1-C20 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Server Technology C-16HF1-C20 verständlich ist.

Eine gänzliche Bedienungsanleitung von Server Technology sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Server Technology C-16HF1-C20 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Server Technology C-16HF1-C20 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Server Technology C-16HF1-C20, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Server Technology C-16HF1-C20 - die uns die ersten Schritte während der Nutzung von Server Technology C-16HF1-C20 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Server Technology C-16HF1-C20 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Server Technology C-16HF1-C20 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Server Technology C-16HF1-C20?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Server Technology C-16HF1-C20 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Server Technology C-16HF1-C20 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)