Bedienungsanleitung York 12

12 Seiten 0.26 mb
Download

Zur Seite of 12

Summary
  • York 12 - page 1

    OUTDOOR SPLIT -SYSTEM AIR CONDITIONER MODELS: 10, 1 2, 13 AND 14 SEER 1 PHASE - 1.5 TO 5 T O NS 035-13606-003 Rev. A (202) T ABLE OF CONTENTS GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . 2 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 L ...

  • York 12 - page 2

    035-13606-003 Rev. A (202) 2 Unitary Products Group GENERAL INFORMA TION These outdoor units are designed to be connected to a matching UPG indoor coil with sweat connection lines. The se units are factory charged with refrigerant for a matching indoor coil plus 15 feet of fie ld supplied line. The outside unit is designed to be placed alongside or ...

  • York 12 - page 3

    035-13606-003 Rev. A (202) Unitary Products Group 3 A minimum clearance of 18 inches is required for service at the control panel and compre ssor compartments access. A 10 inch clearance is required for the air inlet to the outdoor coil around the pe rimeter of the uni t. The air discharg e of the unit requires a 60 inch clearance betwe en the top ...

  • York 12 - page 4

    035-13606-003 Rev. A (202) 4 Unitary Products Group INST ALLA TION OUTDOOR U NIT After the site has been select ed, a solid base pad that will not shift or settle should be provided. Th e base pad should not come in contact with the foundat ion or side of the structur e because sound may be tran smitted to the residence. The pad should be located f ...

  • York 12 - page 5

    035-13606-003 Rev. A (202) Unitary Products Group 5 RE-ASSEMBLING , BRAZING AND CLEANING OF JOINT CONNECTIONS Remove the Schrader V alv e cores from the service valves. Remove the plugs from the service valve fiel d tubing connec- tions. Clean the jo ints to be brazed. NOTE: Do not overheat the connection to be brazed as this can cause improper flo ...

  • York 12 - page 6

    035-13606-003 Rev. A (202) 6 Unitary Products Group REFRIGERANT V AL VE OPERA TION All models in this series have brass service va lves. These valves are not back seating. Opening or closing valve does not close service port. Service ports have Schrader valves for gauge connections. Use back-up wre nch on valve body when removing cap to open o r cl ...

  • York 12 - page 7

    035-13606-003 Rev. A (202) Unitary Products Group 7 LOW VOL T AGE Control wiring may vary depending upon the type of thermo- stat and furnace being connected. Low voltage wiring diagrams can be found with the furnace or air conditioning blower package installation instructions. Pig-tail connector wires (2 blue or 1 blue, 1 brown) are pro- vided fro ...

  • York 12 - page 8

    035-13606-003 Rev. A (202) 8 Unitary Products Group E SYSTEM CHARGE The factory charge in the outdoor unit includes enough charge for the unit a nd a most sold matched evaporator . Some indoor coil matches may requi re some additional charge. See T abular Data sheet provided in unit literature packet. Sweat connect units also include sufficient cha ...

  • York 12 - page 9

    035-13606-003 Rev. A (202) Unitary Products Group 9 T able 3: SUPERHEA T V ALUE INDOOR WB ° F 1 OUTDOOR DB ° F 55 60 65 70 75 80 85 90 95 100 105 1 10 1 15 50 9 7 52 12 10 6 54 14 12 10 7 56 17 15 14 10 6 58 20 18 16 13 9 5 60 23 21 19 16 12 8 6 62 26 24 22 19 16 12 8 5 64 29 27 24 21 18 15 1 1 9 6 66 32 31 30 24 23 18 15 1 1 9 6 68 35 33 30 27 2 ...

  • York 12 - page 10

    035-13606-003 Rev. A (202) 10 Unitary Products Group 3. Measure and record the suction pressure at the su ction service valve port. 4. Using T a ble 4, note the superheat value corresponding to the intersecti on of the indoor wet b ulb and the outdoor dry bulb. 5. With the superheat value o btained in step 4 and the suc- tion pressure value from st ...

  • York 12 - page 11

    035-13606-003 Rev. A (202) Unitary Products Group 11 SER VICE RECORDS ...

  • York 12 - page 12

    Subject to change without notice. Printe d in U.S.A. 035-13606-003 Rev. A (202) Copyright © by Y ork International Corp. 2002. All rights reserved. Supersedes: 035-13606-002, 550.46-N1Y (199) Unitary 5005 Norman Product s Y ork OK Group Drive 73069 ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York 12 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen 12
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York 12
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York 12.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York 12, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York 12. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York 12 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York 12, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York 12 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York 12 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York 12 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York 12 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York 12, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York 12 - die uns die ersten Schritte während der Nutzung von York 12 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York 12 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York 12 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York 12?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York 12 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York 12 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)