Bedienungsanleitung Regency Wraps U41-LP3

24 Seiten 1.66 mb
Download

Zur Seite of 24

Summary
  • Regency Wraps U41-LP3 - page 1

    W ARNING: If the information in these instructions are not followed ex- actly , a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by ...

  • Regency Wraps U41-LP3 - page 2

    2 Regency U41-3 UL TIMA TE Gas Fireplace Insert Note: Oversize faceplate 44-1/4" x 31-1/8" Extra Oversize Faceplate 50-1/4" x 35-1/8" TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Insert by FIREPLACE PRODUCTS IN- TERNA TIONAL L TD. The Regency UL TIMA TE Gas Fireplace Series of hand crafted appli ...

  • Regency Wraps U41-LP3 - page 3

    3 Regency U41-3 UL TIMA TE Gas Fireplace Insert T ABLE OF CONTENTS REGENCY UL TIMA TE GAS FIREPLACE INSERT SAFETY LABEL Safety Labels ................................................... 4 REQUIREMENTS MA Code - CO Detector (for state of Massachusetts only) ......................... 5 INST ALLA TION REQUIREMENTS For your safety ..................... ...

  • Regency Wraps U41-LP3 - page 4

    4 Regency U41-3 UL TIMA TE Gas Fireplace Insert This is a copy of the label that accompanies each Regency UL TIMA TE Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on the right side door panel. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a diff ...

  • Regency Wraps U41-LP3 - page 5

    5 Regency U41-3 UL TIMA TE Gas Fireplace Insert REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chap ter 10 (2) Revise 10.8. 3 by adding the following a dditional requi rements: (a) For all side wall hor izontally ve nted gas fueled e quipment insta lled in every dwelling, bui lding or str ucture used in whole or in part for residential pu rposes, in ...

  • Regency Wraps U41-LP3 - page 6

    6 Regency U41-3 UL TIMA TE Gas Fireplace Insert If the factory built fi replace height is too low for your Insert, you may remove the smoke shelf, baffl e plate, and damper plate from the factory built fi replace if removable without cutting or torching, as long as these items are saved and are re-installed in the event that the Insert is remove ...

  • Regency Wraps U41-LP3 - page 7

    7 Regency U41-3 UL TIMA TE Gas Fireplace Insert MA TERIALS REQUIRED No electrical power supply is required for the gas control to operate. A 120 V olt AC power cord is hooked up to the fan switch and blower . Plug 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circumstances. When connected with 120 volts, the a ...

  • Regency Wraps U41-LP3 - page 8

    8 Regency U41-3 UL TIMA TE Gas Fireplace Insert HIGH ELEV A TION This unit is approved in Canada for altitude 2000 ft. to 4500 ft. (CAN/CGA- 2.17-M91) with the orifi ce kit Part # 611-975. For Natural Gas installations above 4500 ft. follow current CAN/CGA-B149.1. In U.S.A., for installations above 2000 ft. refer to current ANSI Z223.1 Sc8-8.1.2a ...

  • Regency Wraps U41-LP3 - page 9

    9 Regency U41-3 UL TIMA TE Gas Fireplace Insert Draft Hood Flue guides screw holes S pill T ube Rear S pill T ube Front INST ALLA TION 1) If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry fi replace and have the chimney swept. GAS CONNECTION For minimum and maximum supply pressure see the System Data ...

  • Regency Wraps U41-LP3 - page 10

    10 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION Before installing vent system ensure that the damper plate is locked into the open position and secure to prevent the damper plate from falling down and crushing the liner . GAS PRESSURE TEST The unit is preset to give the correct gas input at the specifi ed manifold pressures shown o ...

  • Regency Wraps U41-LP3 - page 11

    11 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION T abs Screws Right Side To p Hinged Louvers 3) Using the trim clips provided, join the left side gold trim (the one with the ON/OFF switch and variable speed F AN switch) to the top gold trim. See diagram 2. Repeat this step for right side. 8) Fan Switch wires : Connect the plug end fr ...

  • Regency Wraps U41-LP3 - page 12

    12 Regency U41-3 UL TIMA TE Gas Fireplace Insert DOOR INST ALLA TION (Packaged Separately) 1) Open the two side doors. 2) Slide the door onto the two hinge pins mak- ing sure the two pieces are fl ush together . See diagram 1. Diagram 1 Diagram 3 Diagram 2 Diagram 4 Diagram 2 Diagram 1 Diagram 3 LOG INST ALLA TION Note: Do not force logs down. INS ...

  • Regency Wraps U41-LP3 - page 13

    13 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION Thermostat Wire T able OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams on page 13. Use table on this page to determine the maximum wire length: Note: Preferable if the thermostat is installed on an interior wall. R ...

  • Regency Wraps U41-LP3 - page 14

    14 Regency U41-3 UL TIMA TE Gas Fireplace Insert WIRING DIAGRAM This heater does not require a 120V A.C. sup- ply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However , a 120V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires ...

  • Regency Wraps U41-LP3 - page 15

    15 Regency U41-3 UL TIMA TE Gas Fireplace Insert OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure t ...

  • Regency Wraps U41-LP3 - page 16

    16 Regency U41-3 UL TIMA TE Gas Fireplace Insert COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS A ) This appliance has a pilot which must be lighted by hand, following the instructions below exactly. B ) BEFORE LIGHTING smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier th ...

  • Regency Wraps U41-LP3 - page 17

    17 Regency U41-3 UL TIMA TE Gas Fireplace Insert MAINTENANCE NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating ...

  • Regency Wraps U41-LP3 - page 18

    18 Regency U41-3 UL TIMA TE Gas Fireplace Insert Installing Glass 1) Install both center and side glass onto extru- sions as per diagram. 2) Place glass assembly into door frame. 3) Install retainers by placing 1 drop of glue where previously glued and put in place. 4) Install side retainers. 5) Install door catch plate. 6) Install the 24 nuts loos ...

  • Regency Wraps U41-LP3 - page 19

    19 Regency U41-3 UL TIMA TE Gas Fireplace Insert MAINTENANCE CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. F AN MAINTENANCE 1) Unplug or disconnect power source to stove. 2) Remove all logs and the rear log support, then remove the 6 screws holding the ac- cess pan ...

  • Regency Wraps U41-LP3 - page 20

    20 Regency U41-3 UL TIMA TE Gas Fireplace Insert P ARTS LIST MAIN ASSEMBL Y Part # Description Part # Description 23) 710-028 Faceplate Mounting Bracket 24) 948-241 Door Latch 25) 910-325 Spill Switch 26) 610-576 False T op Assembly 836-220 False T op Insulation 27) 910-142 Thermodisc - Fan Auto/On/Of f 28) * Thermodisc Bracket 30) 610-175 Rear Pan ...

  • Regency Wraps U41-LP3 - page 21

    21 Regency U41-3 UL TIMA TE Gas Fireplace Insert P ARTS LIST BURNER & LOGS Part # Description 52) 910-190 Piezo Ignitor and nut 56) 910-426 Knob - Flame Hi/Low Extension 613-524/P V alve Assembly -NG 613-526/P V alve Assembly - LP 60) 910-028 V alve - RS - NG 910-029 V alve - RS - LP 904-688 Orifi ce - #32 NG 904-641 Orifi ce - #50 LP 71) * L ...

  • Regency Wraps U41-LP3 - page 22

    22 Regency U41-3 UL TIMA TE Gas Fireplace Insert F ACEPLA TE & TRIM Part # Description Part # Description 103) * Faceplate - Extra Oversize - Side Left Assy 613-538 Trim Pkg. - Extra Oversize -Black 104) * T rim - Extra Oversize - Right 105) * T rim - Extra Oversize - T op 106) * T rim - Extra Oversize - Left 663-91 1 Zero Clearance Faceplate 6 ...

  • Regency Wraps U41-LP3 - page 23

    23 Regency U41-3 UL TIMA TE Gas Fireplace Insert W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime wa ...

  • Regency Wraps U41-LP3 - page 24

    Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ...

Produzent Regency Wraps Kategorie Fire Pit

Dokumente, die wir vom Produzenten des Geräts Regency Wraps U41-LP3 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Regency Wraps
- Bedienungsanleitungen U41-LP3
- Produktkarten Regency Wraps
- Informationsbroschüren
- oder Energieetiketten Regency Wraps U41-LP3
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Regency Wraps U41-LP3.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Regency Wraps U41-LP3, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Regency Wraps U41-LP3. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Regency Wraps U41-LP3 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Regency Wraps U41-LP3, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Regency Wraps U41-LP3 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Regency Wraps U41-LP3 verständlich ist.

Eine gänzliche Bedienungsanleitung von Regency Wraps sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Regency Wraps U41-LP3 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Regency Wraps U41-LP3 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Regency Wraps U41-LP3, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Regency Wraps U41-LP3 - die uns die ersten Schritte während der Nutzung von Regency Wraps U41-LP3 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Regency Wraps U41-LP3 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Regency Wraps U41-LP3 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Regency Wraps U41-LP3?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Regency Wraps U41-LP3 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Regency Wraps U41-LP3 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)