  • State Water Heaters 185244-004 - page 1

    1 Instruction Manual PRINTED 1208 315466-000 KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. POWER VENTED GAS MODELS WITH HOT SURF ACE IGNITION NOT FOR USE IN MANUF ACTURED (MOBILE) HOMES ALL TECHNICAL AND W ARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE ...

  • State Water Heaters 185244-004 - page 2

    2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety m ...

  • State Water Heaters 185244-004 - page 3

    3 GENERAL SAFETY ...

  • State Water Heaters 185244-004 - page 4

    4 SAFE INST ALLA TION, USE AND SERVICE............................2 GENERAL SAFETY..................................................................3 T ABLE OF CONTENTS ............................................................ 4 INTRODUCTION ......................................................................4 Preparing for the New Installatio ...

  • State Water Heaters 185244-004 - page 5

    5 For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters insta lled in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated b y the Commonwealth and where the side wall exhaust vent termination is less than seven ...

  • State Water Heaters 185244-004 - page 6

    6 TYPICAL INST ALLA TION GET TO KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe–Exhaust B V ent T erminal C V ent Adapter-Rubber Boot D Blower Assembly E Cold W ater Inlet F Inlet W ater Shut-off V alve G Union H Inlet Dip T ube J Anode** K Hot W ater Outlet L Outlet Receptacle (1 15 V AC) M T emperature-Pressure Relief V alve FIGURE 1. N Flu ...

  • State Water Heaters 185244-004 - page 7

    7 TYPICAL INST ALLA TION FIGURE 2. MIXING V AL VE USAGE This appliance has been design certi fi ed as complying with American National Standard/CSA Standard for water heaters and is considered suitable for: W ater (Potable) Heating and Space Heating: All models are considered suitable for water (potable) heating and space heating. HOTTER W A TER C ...

  • State Water Heaters 185244-004 - page 8

    8 F ACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Whe ...

  • State Water Heaters 185244-004 - page 9

    9 and 12" (30.5 cm) from the top. (Standard clearance.) If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater . Adequate clearance for servicing this appliance should be considered before installation, such as changing the anodes, etc. A minimum clearance of 5" ...

  • State Water Heaters 185244-004 - page 10

    10 Chemical vapor corrosion of the fl ue, blower assembly and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which ar ...

  • State Water Heaters 185244-004 - page 11

    11 THERMAL EXP ANSION As water is heated, it expands (thermal expansion). In a closed system the volume of water will grow. As the volume of water grows there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limite ...

  • State Water Heaters 185244-004 - page 12

    12 Figure 10 shows the typical attachment of the water piping to the water heater . The water heater is equipped with 3/4 inch NPT water connections. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connection. Do not solder the cold water supply line directly to the cold water inlet. It ...

  • State Water Heaters 185244-004 - page 13

    13 GAS PIPING Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (3.5 kPa) for natural and propane gas (L.P .). The minimum inlet gas pressure shown on the rating plate is that which will permit fi ring at rated input. All gas piping must comply with local codes ...

  • State Water Heaters 185244-004 - page 14

    14 SEDIMENT TRAPS A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fi tting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. If a tee fi tting is used, it shall be installed ...

  • State Water Heaters 185244-004 - page 15

    15 VENT CONNECTIONS TO BLOWER ASSEMBL Y Figure 15 shows the optimal placement of the 2" to 3" or 3" to 4" reducer; however , the vent can be reduced at any point in the vent system as long as the maximum and minimum vent length requirements are met. FIGURE 15. VENTING AND INST ALLA TION Plan the layout of the vent system from th ...

  • State Water Heaters 185244-004 - page 16

    16 The unit may be vented horizontally through a wall or vertically through the roof. Pipe runs must be adequately supported along both vertical and horizontal runs as follows: • For Schedule 40, 2" PVC, ABS, Coex Cellular Core vent pipe: Every 3 feet (0.9 m). • For Schedule 40, 3" PVC, ABS, Coex Cellular Core vent pipe: Every 3.5 fee ...

  • State Water Heaters 185244-004 - page 17

    17 For 4" V enting, the maximum equivalent feet of pipe allowed is 160 feet (48.8 m). This does not include the V ent T ermination (supplied locally) for the water heater . For the 4" venting, one 90° elbow is approximately equal to 8 feet (2.4 m). One 45° elbow is approximately equal to 4 feet (1.2 m). It is recommended that at least 2 ...

  • State Water Heaters 185244-004 - page 18

    18 FIGURE 16. This unit can vent through 2", 3" or 4" nonmetallic pipe and fi ttings. The vent pipe installation can be started from either the blower discharge or the termination wall. Keep in mind the total vent system (pipe and elbows) when installing the vent system, see VENTING AND INST ALLA TION, pages 15 - 17. FIGURE 17. The ...

  • State Water Heaters 185244-004 - page 19

    19 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the speci fi c application you are attempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C . Know the reputation of your manufacturer and ...

  • State Water Heaters 185244-004 - page 20

    20 B. Deburring Use a knife, plastic pipe deburring tool, or fi le to remove burrs from the end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°-15° should be added to the end to permit easier insertion of the pipe into the end of the fi tting. F ...

  • State Water Heaters 185244-004 - page 21

    21 ...

  • State Water Heaters 185244-004 - page 22

    22 Due to the nature of the typical gas water heater , the water temperature in certain situations may vary up to 30°F (16.7°C) higher or lower at the point of use such as, bathtubs, showers, sink, etc. It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all cases, that the water te ...

  • State Water Heaters 185244-004 - page 23

    23 FOR YOUR INFORMA TION ST ART UP CONDITIONS CONDENSA TE Whenever the water heater is fi lled with cold water, some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensate. This usually happens when: a. A new water heater is fi lled with cold water for the fi rst time. b. Burning ...

  • State Water Heaters 185244-004 - page 24

    24 VENTING SYSTEM INSPECTION At least once a year a visual inspection should be made of the venting system. Y ou should look for: 1. Obstructions which could cause improper venting. The combustion and ventilation air fl ow must not be obstructed. 2. Damage or deterioration which could cause improper venting or leakage of combustion products. Be su ...

  • State Water Heaters 185244-004 - page 25

    25 INST ALLED IN SUIT ABLE AREA: T o insure suf fi cient ventilation and combustion air supply , proper clearances from the water heater must be maintained. See “Locating the New W ater Heater” section. Combustible materials such as clothing, cleaning materials, or fl ammable liquids, etc. must not be placed against or adjacent to the water h ...

  • State Water Heaters 185244-004 - page 26

    26 LEAKAGE CHECKPOINTS Read this manual fi rst. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water . Never use this water heater unless it is completely fi lled with water . T o prevent damage to the tank, the tank must be fi lled w ...

  • State Water Heaters 185244-004 - page 27

    27 Key No. Part Description 1 Burner Assembly 2 Burner Head 3 Burner Ori fi ce 4 Burner T ube 5 HSI Ignition Assembly 6 Inner Door 7 Inner Door Gasket 8 Flue Baf fl e 9 Flue Restrictor 10 Blower Assembly 1 1 Air Intake Screen - Base Pan 12 Inlet T ube 13 Gas Control V alve 14 Drain V alve 15 Drain V alve Washer 16 Outer Door (may appear different ...

  • State Water Heaters 185244-004 - page 28

    28 TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a quali fi ed service technician. Read the GENERAL SAFETY INFORMA TION section fi rst. ...

  • State Water Heaters 185244-004 - page 29

    29 ...

  • State Water Heaters 185244-004 - page 30

    30 These guidelines should be utilized by a quali fi ed service agent. When calling for service notify the service agent that this is a “Flammable V apor Ignition Resistant” Product. TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES Figure 1 and 15. Page 9. ...

  • State Water Heaters 185244-004 - page 31

    31 THIS W ARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . If the glass lined tank in this water heater shall prove upon examination by (the warrantor) to have leaked during the warranty period in normal residential use, due to natural corrosion from potable water therein, the warrantor will furnish the ORIGINAL OWNER a replacement water heater ...

  • State Water Heaters 185244-004 - page 32

    32 500 T ennessee Waltz Parkway Ashland City , TN 37015 www .statewaterheaters.com ...

Produzent State Water Heaters Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts State Water Heaters 185244-004 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen State Water Heaters
- Bedienungsanleitungen 185244-004
- Produktkarten State Water Heaters
- Informationsbroschüren
- oder Energieetiketten State Water Heaters 185244-004
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung State Water Heaters 185244-004.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen State Water Heaters 185244-004, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen State Water Heaters 185244-004. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts State Water Heaters 185244-004 ansehen.

Die komplette Bedienungsanleitung des Geräts State Water Heaters 185244-004, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von State Water Heaters 185244-004 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von State Water Heaters 185244-004 verständlich ist.

Eine gänzliche Bedienungsanleitung von State Water Heaters sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von State Water Heaters 185244-004 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von State Water Heaters 185244-004 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich State Water Heaters 185244-004, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts State Water Heaters 185244-004 - die uns die ersten Schritte während der Nutzung von State Water Heaters 185244-004 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit State Water Heaters 185244-004 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von State Water Heaters 185244-004 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich State Water Heaters 185244-004?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit State Water Heaters 185244-004 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit State Water Heaters 185244-004 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)