Bedienungsanleitung Symbol Technologies AccuScan Palm Pro

34 Seiten 0.41 mb
Download

Zur Seite of 34

Summary
  • Symbol Technologies AccuScan Palm Pro - page 1

    AccuScan Palm / AccuScan Palm Pro Version 2.0 User Manual AccuScan Palm Version 2.0 POS-X Inc. Telephone: 1-800-903 -65 72 Fax: 1-360-738-3048 http://www.pos-x.com support@pos -x.com This docum ent and the s oftware described by this doc ument are sold a nd distribut ed by POS-X Inc. All rights reserved. Use of the s oftware described here i n may ...

  • Symbol Technologies AccuScan Palm Pro - page 2

    AccuScan Palm / AccuScan Palm Pro Version 2.0 User Manual Contents Chapter 1: Introduct ion ................................................................................................................ 4 1.1 What is AccuScan Palm? .............................................................................................. 4 1.2 New Features in ...

  • Symbol Technologies AccuScan Palm Pro - page 3

    5.5 HotSyncing Data from the PC to the PD A ................................................................... 30 5.5.1 Sending Session Data to the PDA .............................................................. 31 5.5.2 Creating Session Data Files with Excel ...................................................... 31 5.5.3 Sending Drop-Down List ...

  • Symbol Technologies AccuScan Palm Pro - page 4

    Chapter 2: Installation Chapter 1: Introduction 1.1 What is AccuScan Palm? Create enterprise class, ba rco de enabled, data collection applications in minute s for most tasks including asset management, inventory control, and many others with AccuSca n Palm. No programming knowled ge is neede d. Simply create your familiar forms right on your PDA. ...

  • Symbol Technologies AccuScan Palm Pro - page 5

    Chapter 2: Installation 1.3 Free Trial AccuScan Palm is a shareware application. A shareware applicatio n typically means that you can use it on a trial basis for no fee. In the Accu Scan Palm Splash Screen, select the version you would like to try (Standard or Pro) and y ou can dem o all of the features for that version. The trial download is limi ...

  • Symbol Technologies AccuScan Palm Pro - page 6

    Chapter 2: Installation 1.6 Integrating AccuScan Palm AccuScan Palm data can be HotSynced to the PC in one of five popular file format s. Refer to Section 5.3.1 for a more detailed discussion on file transfer formats. This flexibility makes it possible to integrate AccuScan Palm with most programs and data bases. Accu Scan Palm Pro also allows for ...

  • Symbol Technologies AccuScan Palm Pro - page 7

    Chapter 2: Installation Chapter 2: Installation This chapter details the steps for installing AccuScan Palm. 2.1 System Requirements • Windows 95/98/NT/2000/ XP • Palm Desktop v3.1 or higher (include s HotSync Manager) • Palm OS PDA running Palm OS 3.0 or higher 2.2 Automatic Installation 1. Make sure you have Palm Desktop installed an d work ...

  • Symbol Technologies AccuScan Palm Pro - page 8

    Chapter 2: Installation POS-X encourages all users wh o ben efit from AccuSc an Palm to register their copy. To register AccuScan Palm, we only require your AccuSc an Palm PDA ID and an Email address. We generate a unique registration cod e for your AccuSc an Palm PDA ID so it is important that you send the ID exactly as it appears on the Accu Scan ...

  • Symbol Technologies AccuScan Palm Pro - page 9

    Chapter 2: Installation New Registration Code Required Due to a new licensing algorithm, all users upgradi ng to AccuScan Palm 2.0 will need to get a new registration code. This pro ce s s is d iscussed in Section 2.4. You can easily register by calling POS-X.com at 1-800-903-6572. New Location for Data Files C:Program FilesAccuScan PalmData us ...

  • Symbol Technologies AccuScan Palm Pro - page 10

    Chapter 3: Sessions Chapter 3: Sessions AccuScan Palm allows users to create up to 32 unique data capture programs. These uniq ue programs are called Se ssions . Sessions ar e easily acce ssed from the Main Screen , where captured data can be viewed and searched. In this section, you will learn how to config ure session attributes to meet your data ...

  • Symbol Technologies AccuScan Palm Pro - page 11

    Chapter 3: Sessions 2 . Select Session Settings. 3. Select the New button. A ccuScan Sessions [ General ] 4 . Enter the name of the session you are creatin g. 5. Configure your session’s General, Hot Sy nc, Data and Backup attributes as describe d in AccuScan Sessions [ General ] Sections 3.2.1 - 3.2.4 . When you are finished, pre ss Done. If you ...

  • Symbol Technologies AccuScan Palm Pro - page 12

    Chapter 3: Sessions option takes effect only when this session was the last one used – each session h as its own settings. Start On Field Select the first field the User is focused on when New is selected from the data view screen. This setting is commonly selected to control what data must be entere d when the program is initially opened. Exampl ...

  • Symbol Technologies AccuScan Palm Pro - page 13

    Chapter 3: Sessions Archive PC Data Select Archive PC Data if you wish to archive any PC files transferred to the PDA during HotSync. Any data files sent from the PC are renamed with a prefi x of “ old_” after a successful HotSync if this option is selected. In a multi-us er environment, many users would not sele ct this option because it preve ...

  • Symbol Technologies AccuScan Palm Pro - page 14

    Chapter 3: Sessions This formatting option transfers all fields using a fixed width. Any space remaining at the end of Field data is padded with spaces. Use of the M ax Length fiel d setting is also used to dictate the width of each fixed width field. The maximum length of any given field is 30 chars. Each record is terminated with CRLF. XML This f ...

  • Symbol Technologies AccuScan Palm Pro - page 15

    Chapter 3: Sessions AccuScan Settin g s [ Backu p ] Note: Enabling these backup option s can slo w down your HotSync process consid erably, since each time you HotSync a copy of the se lected database s i s made on your PC. You may want to enable these options, then HotSync, then disable them again once you have the copies made. Backup Session Data ...

  • Symbol Technologies AccuScan Palm Pro - page 16

    Chapter 4: Field Settings Chapter 4: Field Settings After a session is created, fields within th at se ssion may also requi re configuration. Before configuration, all available fields with in the session are in a default state. Customizing your se ssion settings and field settings i s not re quired , as the default settings will work perfectly for ...

  • Symbol Technologies AccuScan Palm Pro - page 17

    Chapter 4: Field Settings 2. Select Field Settings . 3 . Select a AccuScan P alm ses sion. 4 . Select a field to configure. 5. Enter the field Name . 6. Select a Field Type . Section 4.2.1 discusses these field types in more detail. AccuScan Settin g s [ General ] A ccuScan Settin g s [ General ] 7. Enter General field settings. Section 4.2.2 discu ...

  • Symbol Technologies AccuScan Palm Pro - page 18

    Chapter 4: Field Settings 4.2 Field Settings Explained 4.2.1 Field Types The Field Type setting is used to control what type of data is entered for this field. AccuScan Palm has four available Field Types: Text, Drop-Down, Checkb ox and Variable . AccuScan Palm Pro has an additional Signature Field Type. AccuScan Settin g s [ General ] Text Text fi ...

  • Symbol Technologies AccuScan Palm Pro - page 19

    Chapter 4: Field Settings Check Box Check box fields are used when simple Yes/No, True/False, On/Off selectio ns a re made. Check boxes should be used wh enever possible to speed data entry, and limit data entry error. AccuScan Settin g s [ General ] Variable Variable fields are used to automatically enter values such as Time and Date. T o set a Va ...

  • Symbol Technologies AccuScan Palm Pro - page 20

    Chapter 4: Field Settings DATESYS When DATESYS is selected, the current date is automatically entered in the field in the same format as you have chosen in system prefs. This option give you the gre atest flexibility. To select a date format, c lick on “Home” and then “Pref s”, and cho ose “Formats” from the upper right-hand me nu. USER ...

  • Symbol Technologies AccuScan Palm Pro - page 21

    Chapter 4: Field Settings AccuScan Settin g s [ General ] General General is set to accept all data types in a field, including date time stamps . Numeric Numeric is set when the field is only use d for numeric data. When a field’s Data Type is set to Numeric, it does not accept any Alpha characters. Date Date is set when the field is used to ent ...

  • Symbol Technologies AccuScan Palm Pro - page 22

    Chapter 4: Field Settings Note 1: The Default value is only used when the Clear on Submit option in the After Scan menu is selected for this field. If the user change s this value during data entry and Clear on Submit is not checked, the changed valu e is retained for the next record. Note 2: If the user clicks the Clear All button from the data en ...

  • Symbol Technologies AccuScan Palm Pro - page 23

    Chapter 4: Field Settings Read Only When the Read Only option is sel ected, the user does not have the ability to enter data in the selected field. This is com monly use d in conjunction with default values and Variable type fields. 4.2.3 Validation Field Settings Validation Field Settings allow the user to exhibi t cont rols that check the accurac ...

  • Symbol Technologies AccuScan Palm Pro - page 24

    Chapter 4: Field Settings NOTE: The ‘After Scan’ rules are trigge red by both a completed barcode scan as well as pre s sing the Down Arro w key on your PDA. AccuScan Settin g s [ After Scan ] Auto Submit This option represents wh ether or not to autom atically submit this record following an ' After Scan' event for this field. If thi ...

  • Symbol Technologies AccuScan Palm Pro - page 25

    Chapter 4: Field Settings 4.2.5 Drop-Down Lists Drop Downs allow AccuScan Palm u se rs to create th eir own Dro p-Down list menus for specific fields. AccuScan Palm gives the us er the ability to create these lists either directly on the PDA or from a file on the PC via a HotSync data transfer. AccuScan Settin g s [ Dro p -down ] Allow PC Update Th ...

  • Symbol Technologies AccuScan Palm Pro - page 26

    Chapter 4: Field Settings 3. Enter a List Item via barcode scan or Graffiti. 4. Repeat steps 2-3 to add additional list items. AccuScan Palm List Items can be e dited and deleted in the AccuScan Palm Lists screen. Simply choose the value to be edited and select the appropri ate button. NOTE : List Items may also be deployed to multiple user s. In m ...

  • Symbol Technologies AccuScan Palm Pro - page 27

    Chapter 5: Managing Data Chapter 5: Managing Data 5.1 Entering Data To enter data in AccuScan Palm, the user must firs t select the appropriate session. Once that is selected, clicking the Ne w button will start the data en try/collection process. AccuScan Entry Screen The Entry Screen is the area where the use r does his data entry. The fields are ...

  • Symbol Technologies AccuScan Palm Pro - page 28

    Chapter 5: Managing Data Clicking any field’s label will open the field’s Hi nt window. The Hints window displays reference details that aid in data collectio n. Sections 4.2.2 explains how to create and edit field Hints. AccuScan Settin g s [ General ] 5.2 Quick Buttons AccuScan Palm specialize s in streamlini ng screen interaction. We do this ...

  • Symbol Technologies AccuScan Palm Pro - page 29

    Chapter 5: Managing Data 5.3 Finding Data While in the Main Screen, AccuScan P alm users can search the session database whil e by using the Find feature. Follow the directio ns below to use the find feature. 1. Select a field to search. 2. Scan or enter data into the Find Field. 3. Click the Find button. A ccuScan AccuScan If you are manually ente ...

  • Symbol Technologies AccuScan Palm Pro - page 30

    Chapter 5: Managing Data 5.4.3 Linking AccuScan Palm Sessi on Data to an MS Access Table Microsoft Access is an affordable and popular database that can be utilized to ma nage AccuScan Palm data. To import AccuScan Palm session 1 data, file name S01_data.txt, follow these steps: 1. In MS Access, open your databa se or create a new d ataba se. 2. Se ...

  • Symbol Technologies AccuScan Palm Pro - page 31

    Chapter 5: Managing Data 5.5.1 Sending Session Data to the PDA All data prepared for upload to the PDA must be stored in a folder called ToPDA . This folder must be located under the AccuS can PalmData folder where AccuScan Palm was install ed, and inside the folder for the current use r. These fo lders are autom atically cr eated after HotSynci n ...

  • Symbol Technologies AccuScan Palm Pro - page 32

    Chapter 5: Managing Data 6. Close the Excel file 7. Perform a HotSync to upload the data file to the PDA 5.5.3 Sending Drop-Down Lists to the PDA AccuScan Palm also allows the user to prep are and manage Drop-Down lists on the PC for later upload to the PDA running AccuS ca n Palm. The filename of list da ta to be uploaded must be named S xx F yy . ...

  • Symbol Technologies AccuScan Palm Pro - page 33

    Chapter 6: Administration Settings Chapter 6: Administration Settings Once sessions are configured it is cu sto mar y to implement password protection so field personnel cannot easily alter the session setting s. When a Pass word is set, a user is required to enter this Password to access any areas protected by the AccuScan Palm Admin Settings. Adm ...

  • Symbol Technologies AccuScan Palm Pro - page 34

    Chapter 6: Administration Settings 6.2 Deploying Configured Sessions to Multiple User s 6.2.1 How to Copy One PDA’s Configuration to Oth er PDAs AccuScan Palm config ured sessions can easily be deployed to your mobile workforce. To perform an enterprise-wide deployment, simply follow these step s. 1. Create desired configuratio n on one PDA. 2. T ...

Produzent Symbol Technologies Kategorie PDAs & Smartphones

Dokumente, die wir vom Produzenten des Geräts Symbol Technologies AccuScan Palm Pro erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Symbol Technologies
- Bedienungsanleitungen AccuScan Palm Pro
- Produktkarten Symbol Technologies
- Informationsbroschüren
- oder Energieetiketten Symbol Technologies AccuScan Palm Pro
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Symbol Technologies AccuScan Palm Pro.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Symbol Technologies AccuScan Palm Pro, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Symbol Technologies AccuScan Palm Pro. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Symbol Technologies AccuScan Palm Pro ansehen.

Die komplette Bedienungsanleitung des Geräts Symbol Technologies AccuScan Palm Pro, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Symbol Technologies AccuScan Palm Pro hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Symbol Technologies AccuScan Palm Pro verständlich ist.

Eine gänzliche Bedienungsanleitung von Symbol Technologies sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Symbol Technologies AccuScan Palm Pro bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Symbol Technologies AccuScan Palm Pro befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Symbol Technologies AccuScan Palm Pro, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Symbol Technologies AccuScan Palm Pro - die uns die ersten Schritte während der Nutzung von Symbol Technologies AccuScan Palm Pro erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Symbol Technologies AccuScan Palm Pro hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Symbol Technologies AccuScan Palm Pro im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Symbol Technologies AccuScan Palm Pro?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Symbol Technologies AccuScan Palm Pro nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Symbol Technologies AccuScan Palm Pro hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)