Bedienungsanleitung Monessen Hearth CDV7

68 Seiten 4.65 mb
Download

Zur Seite of 68

Summary
  • Monessen Hearth CDV7 - page 1

       ? ...

  • Monessen Hearth CDV7 - page 2

    CDV SC7 & C D V7 Se ries Gas F ir e place  69D301 1        ...

  • Monessen Hearth CDV7 - page 3

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 3 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 4" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. T his fir epla ce reac hes hig h ...

  • Monessen Hearth CDV7 - page 4

    CDV SC7 & C D V7 Se ries Gas F ir e place 4 69D301 1        1. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace. 14. Do not use any solid fuels (wood, coal, paper , card- board, etc.) in this ...

  • Monessen Hearth CDV7 - page 5

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 5       • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The ...

  • Monessen Hearth CDV7 - page 6

    CDV SC7 & C D V7 Se ries Gas F ir e place 6 69D301 1     Inpu t ratin gs are shown in BTU per hour and are cer tified without deration for elevations up to 4,500 feet (1,370 m) above sea level. For elevations above 4,500 feet (1,370 m) in USA, installations must ...

  • Monessen Hearth CDV7 - page 7

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 7 Figure 2 - CDVR Series Fireplace Dimensions  G F H A J C Q D E 1 56M ” 15/16” P - Minimum Rough Opening Width Minimum Rough Opening Depth 1/2” 5/8” 5/8” 1/2” Minimum Rough Opening Height C ...

  • Monessen Hearth CDV7 - page 8

    CDV SC7 & C D V7 Se ries Gas F ir e place 8 69D301 1  G F H A J C R D E 1 56M ” 15/16” Q - Minimum Rough Opening Width P Minimum Rough Opening Depth 1/2” 5/8” 5/8” 1/2” Minimum Rough Opening Height 5/8” 1/2” 5/8” 1/2” I K L M O N N B ...

  • Monessen Hearth CDV7 - page 9

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 9       Read this homeowner manual thoroughly and follow all instructions carefully . Inspect all contents for shipping damag e and imm ediately inform your dealer ...

  • Monessen Hearth CDV7 - page 10

    CDV SC7 & C D V7 Se ries Gas F ir e place 10 69D301 1   Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent conf igurati on to be used, framing and fini shing details, and wheth er any optional accessor ies (i.e. blower , wall sw ...

  • Monessen Hearth CDV7 - page 11

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 1 1            ? ...

  • Monessen Hearth CDV7 - page 12

    CDV SC7 & C D V7 Se ries Gas F ir e place 1 69D301 1 The fi rep lac e m ust be se cur ed to th e floor and/or to framing studs as shown in Figure 7 . Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor . Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/" or 5/8" ...

  • Monessen Hearth CDV7 - page 13

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 13    Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual ...

  • Monessen Hearth CDV7 - page 14

    CDV SC7 & C D V7 Se ries Gas F ir e place 14 69D301 1     V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Operable Operable Fixed Closed V B CFM145a DV T ermin ...

  • Monessen Hearth CDV7 - page 15

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 15     Outside Corner Inside Corner T ermination Clearances T ermination clearances for buildings with combustible and noncombustible exteriors. G = Combustible 6" (152 mm) Noncombustible 2" ...

  • Monessen Hearth CDV7 - page 16

    CDV SC7 & C D V7 Se ries Gas F ir e place 16 69D301 1  When using twist lock pipe it is not necessary to use seal- ant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telescopic vent section used in the ...

  • Monessen Hearth CDV7 - page 17

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 17  The V ent Graph should be read in conjunction with the following vent installation instructions to determine the re- lationship between the vertical and horizontal dimensions of the vent system. 1. Determine the heig ...

  • Monessen Hearth CDV7 - page 18

    CDV SC7 & C D V7 Se ries Gas F ir e place 18 69D301 1 3" 1" 1" 1" FP2288 TV rear vent    Figure 14 - Combustible Clearances for V ent Pipe A Mi nimu m of 3" Cle ara nce to the T op Is Required Along Horizontal Length until Flue Pipe Penetrates Outside W all. ...

  • Monessen Hearth CDV7 - page 19

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 19     When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance. • Only MHSC venting components are approved to be used in these applica ...

  • Monessen Hearth CDV7 - page 20

    CDV SC7 & C D V7 Se ries Gas F ir e place 0 69D301 1        FP2294 Side View Vent Termination 1/25/00 djt Finish W all V ent T ermination FP94 Figure 17 - Side V iew of Final Unit Location    ? ...

  • Monessen Hearth CDV7 - page 21

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 1 • The maximum number of 90° elbows per side wall in- stallation is three (3). Figure 21 • If a 90° elbow is fitted directly on top of the fireplace flange the maximum horizontal vent run before the ter- mination or a vertical rise is 36” (914 mm). Figure 22 • If a 90° elbow is u ...

  • Monessen Hearth CDV7 - page 22

    CDV SC7 & C D V7 Se ries Gas F ir e place  69D301 1              Locate vent opening on the wall. It may b ...

  • Monessen Hearth CDV7 - page 23

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 3     Use appropriate length of pipe sections - telescopic or fixed - and install. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary . ? ...

  • Monessen Hearth CDV7 - page 24

    CDV SC7 & C D V7 Se ries Gas F ir e place 4 69D301 1           When it is not possible to meet the required vent terminal clearances of 1” (305 mm) above grade level, a snor- kel kit is recom ...

  • Monessen Hearth CDV7 - page 25

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 5 • For the minimum height of the vent above the highest point of penetration through the roof refer to Figure 38, Page 6. Max. Height 40’ (1. m) Min. Height 8’ (.4 m) Max. 10’ (3 m) Support Straps Every 3’ (.9 m) Max. Height 40’ (1. m) Min. Height 8’ (.4 m ...

  • Monessen Hearth CDV7 - page 26

    CDV SC7 & C D V7 Se ries Gas F ir e place 6 69D301 1        FP1184 T ypical roof/ceiling suppor t apps.        ? ...

  • Monessen Hearth CDV7 - page 27

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 7     Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper f ...

  • Monessen Hearth CDV7 - page 28

    CDV SC7 & C D V7 Se ries Gas F ir e place 8 69D301 1    A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. Figure 41   ? ...

  • Monessen Hearth CDV7 - page 29

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 9    1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, ? ...

  • Monessen Hearth CDV7 - page 30

    CDV SC7 & C D V7 Se ries Gas F ir e place 30 69D301 1 ON OFF OPTIONAL REMOTE W ALL SWITCH ON OFF OPTIONAL REMOTE CONTROL RECEIVER PILOT HI LO ON OFF TH TP TH/TP ON OFF RS FP1980 Dv wiring diagram   A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be ...

  • Monessen Hearth CDV7 - page 31

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 31     Figure 45 - Remote Wall Switch W iring Diagram #1 #2 #3 #4 #5 #6 7# Electronic V alve GRA Y #7 RED #2 RED #2 BLACK #4 GR ...

  • Monessen Hearth CDV7 - page 32

    CDV SC7 & C D V7 Se ries Gas F ir e place 3 69D301 1     This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly .  BEFORE OPERA TING smell all around the a ...

  • Monessen Hearth CDV7 - page 33

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 33    PILOT O F F P I L O T O N FP1935 control knob pilot Continued on next page  Y ou may check for gas leaks w ...

  • Monessen Hearth CDV7 - page 34

    CDV SC7 & C D V7 Se ries Gas F ir e place 34 69D301 1    PILOT O F F P I L O T O N O F F P I L O T O N PILOT FP1937 control knob on Figure 49 - On Position PILOT O F F P I L O T O N FP1935 control knob pilot Figure 48 - On/Off/RS Switch OFF ON RS  ...

  • Monessen Hearth CDV7 - page 35

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 35    This appliance is equipped with an ignition device (Piezo) which automatically lights the pilot. Do NOT try to light the burner by hand.  BEFORE ...

  • Monessen Hearth CDV7 - page 36

    CDV SC7 & C D V7 Se ries Gas F ir e place 36 69D301 1     1. Check gas type. The gas supply must be the same as state d on the appl iance’ s ratin ...

  • Monessen Hearth CDV7 - page 37

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 37  1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. . Remove the external junction box cover by removing the screw ...

  • Monessen Hearth CDV7 - page 38

    CDV SC7 & C D V7 Se ries Gas F ir e place 38 69D301 1 T o Junction Box in Fireplace Optional AC Module { White Black Optional Light White Black { Optional Blower White Black { Optional Aux. Green Plug in Connector Connector Pin T o Control Board Input 300 W att Max. Each Optional A/C Module Replaces 6V Adapter When Used 6V AC Adapter Control Bo ...

  • Monessen Hearth CDV7 - page 39

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 39 To Junction Box In Fireplace WHITE BLACK WHITE BLACK BLACK WHITE GREEN Connector Pin To Contro l Box { { Optional Light Optional AUX Blower (300w Max) FP2103 AC fan wiring Figure 57 - Blower Wiring Diagram FP103    ? ...

  • Monessen Hearth CDV7 - page 40

    CDV SC7 & C D V7 Se ries Gas F ir e place 40 69D301 1        Figure 58 - BLOT Blower Wiring Diagram B L A C K B L A C K WHITE GREEN BLACK BLACK WHITE Receptacle Junction ...

  • Monessen Hearth CDV7 - page 41

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 41     This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions.  BEFORE OPERA TING smell all ...

  • Monessen Hearth CDV7 - page 42

    CDV SC7 & C D V7 Se ries Gas F ir e place 4 69D301 1      1.  Read the safety information above. . This appliance is equipped w ...

  • Monessen Hearth CDV7 - page 43

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 43    • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer) • ON/OFF/HI/Med/Low Operation • Optional W all Mounting  ...

  • Monessen Hearth CDV7 - page 44

    CDV SC7 & C D V7 Se ries Gas F ir e place 44 69D301 1   All System configuration/setup is done on the Command Center .  When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center .  ...

  • Monessen Hearth CDV7 - page 45

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 45        1. Turn on the ...

  • Monessen Hearth CDV7 - page 46

    CDV SC7 & C D V7 Se ries Gas F ir e place 46 69D301 1     1. Remove upper and lower louvers. . Release the clamps on the bottom of the fireplace. Figure 61 3. Tilt glass frame ou ...

  • Monessen Hearth CDV7 - page 47

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 47 L G637 CDV logs   Figure 63 1. Place rear log (#1) on grate assembly . Log should rest firmly on the two log mounting pins shown. . Place top right log (#) on the rear log. Rest the right back side of the log ...

  • Monessen Hearth CDV7 - page 48

    CDV SC7 & C D V7 Se ries Gas F ir e place 48 69D301 1      Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year . Make sure the burner porting, pilot air open ...

  • Monessen Hearth CDV7 - page 49

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 49    The fireplace and venting system should be inspected before initial use and at least annually by a quali- fied field service person. Inspect the external vent cap on a regular basis ...

  • Monessen Hearth CDV7 - page 50

    CDV SC7 & C D V7 Se ries Gas F ir e place 50 69D301 1       1. Spark ignitor will not light pilot after repeated triggering of piezo. . Pil ...

  • Monessen Hearth CDV7 - page 51

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 51      4. Frequent pilot outage problem. 5. The pilot and main burner extinguish while in operation 6. Glass Soots 7. Flame burns blue and ...

  • Monessen Hearth CDV7 - page 52

    CDV SC7 & C D V7 Se ries Gas F ir e place 5 69D301 1      1. T urn gas supply off. . T urn ON/OFF switch to “ON” Power to module (4V Normal)  Is there a spark across ignitor sensor gap?  T urn ...

  • Monessen Hearth CDV7 - page 53

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 53  OPERA TION Install batteries and/or plug in the AC board Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center F AUL T No beep in about 8 seconds No beep or no sound from the valve indicating pilot ...

  • Monessen Hearth CDV7 - page 54

    CDV SC7 & C D V7 Se ries Gas F ir e place 54 69D301 1    1 4 2 3 6 6 5 (CDVR Series) 5 (CDVT Series) 6 6 12 9 7,10,1 1,13 ...

  • Monessen Hearth CDV7 - page 55

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 55             ? ...

  • Monessen Hearth CDV7 - page 56

    CDV SC7 & C D V7 Se ries Gas F ir e place 56 69D301 1      1 2C 2I 2T 2 4 5 6 3 8 9 7 10 1 1,12,13,14 693011 CDV millivolt parts ...

  • Monessen Hearth CDV7 - page 57

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 57            ? ...

  • Monessen Hearth CDV7 - page 58

    CDV SC7 & C D V7 Se ries Gas F ir e place 58 69D301 1            ...

  • Monessen Hearth CDV7 - page 59

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 59   1 2 3 4 20 5 6 7 8 9 13,14,15,16,17 693011 cdvrt7 SC par ts 12   ...

  • Monessen Hearth CDV7 - page 60

    CDV SC7 & C D V7 Se ries Gas F ir e place 60 69D301 1               ...

  • Monessen Hearth CDV7 - page 61

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 61 1 3 2 693011 cdv log par ts           ? ...

  • Monessen Hearth CDV7 - page 62

    CDV SC7 & C D V7 Se ries Gas F ir e place 6 69D301 1    V ertical V ent T ermination Kits V ertical V ent T ermination w/ Storm Collar 7TDVSKV (flashing NOT included) V ertical V ent T ermination w/ Storm Collar - 8 p ...

  • Monessen Hearth CDV7 - page 63

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 63    Horizontal V ent T ermination Kits Rear V ent Hot T ouch T ermination Kit w/ 10" to 16" 7TBRHTK Adjustable T ermination Pipe, Firestop, and Hot T ouch T ...

  • Monessen Hearth CDV7 - page 64

    CDV SC7 & C D V7 Se ries Gas F ir e place 64 69D301 1 ...

  • Monessen Hearth CDV7 - page 65

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 65 ...

  • Monessen Hearth CDV7 - page 66

    CDV SC7 & C D V7 Se ries Gas F ir e place 66 69D301 1  This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in ...

  • Monessen Hearth CDV7 - page 67

    CDV SC7 & C D V7 Se ries Gas F ir e place 69D301 1 67     The following components are warranted for life to the original owner , subject to proof of purchase: Firebox, Combustion Chamber , Heat Exch ...

  • Monessen Hearth CDV7 - page 68

     149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com Based on CSA P .4.1-09 Based on CSA P .4.1-09 Recher chez dans la br ochure les caractéristique de rendement énergétique de f oy er au gaz Énerguide Selon CSA P .4.1-09    ...

Produzent Monessen Hearth Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Monessen Hearth CDV7 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Monessen Hearth
- Bedienungsanleitungen CDV7
- Produktkarten Monessen Hearth
- Informationsbroschüren
- oder Energieetiketten Monessen Hearth CDV7
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Monessen Hearth CDV7.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Monessen Hearth CDV7, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Monessen Hearth CDV7. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Monessen Hearth CDV7 ansehen.

Die komplette Bedienungsanleitung des Geräts Monessen Hearth CDV7, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Monessen Hearth CDV7 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Monessen Hearth CDV7 verständlich ist.

Eine gänzliche Bedienungsanleitung von Monessen Hearth sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Monessen Hearth CDV7 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Monessen Hearth CDV7 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Monessen Hearth CDV7, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Monessen Hearth CDV7 - die uns die ersten Schritte während der Nutzung von Monessen Hearth CDV7 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Monessen Hearth CDV7 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Monessen Hearth CDV7 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Monessen Hearth CDV7?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Monessen Hearth CDV7 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Monessen Hearth CDV7 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)