    T r ansition Netw orks CPSMC0800-100 8-Slot P ointSystem™ Chassis User’ s Guide (revision A) ...

  • Transition Networks CPSMC0800-100 - page 2

    2 CPSMC0800-100 PointSystem™ Chassis T ech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 Compliance Information UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark FCC Regulations T his equipment has been tested and found to comply with the limits for a class A digital device, pursuant to pa ...

  • Transition Networks CPSMC0800-100 - page 3

    3 CPSMC0800-100 PointSystem™ Chassis T able of Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Unpacking the CPSMC0800-100 Equipment . . . . . . . . . . . . . . . . .5 2 Slide-in-Modules . ...

  • Transition Networks CPSMC0800-100 - page 4

    4 CPSMC0800-100 PointSystem™ Chassis introduction 1 Intr oduction 1.1 Description T he T ransition Networks PointSy stem™ CPSMC0800-100 is a 19-inch, rac k-mount- able chassis for selected T ransition Networks Media Conv erter Slide-In-Modules. T he CPSMC0800-100 allows the network administr ator to connect various copper and fiber -optic netwo ...

  • Transition Networks CPSMC0800-100 - page 5

    5 CPSMC0800-100 PointSystem™ Chassis introduction 2.1 Unpacking the CPSMC0800-100 Equipment Use the following list to verify the shipment: Item P art Number 8-Slot chassis with A C power supply CPSMC0800-100 8-Slot chassis with DC po wer supply CPSMC0810-100 P ower Cord (varies b y country) External AC P ower Supply CPSMP-180 (optional) External ...

  • Transition Networks CPSMC0800-100 - page 6

    6 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules 2 Slide-in-Modules 2.1 Media Converter Slide-in-Modules T ransition Networks Media Conv erter Slide-in-Modules, installed in slots at the front of the chassis, allo w the network administrator to connect various copper and fiber - optic network media ov er protocols that include Ethernet, F a ...

  • Transition Networks CPSMC0800-100 - page 7

    7 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules 2.1.2 Installing the Media Converter Slide-in-Modules CA UTION: W ear a grounding device and obser ve electr ostatic discharge precau- tions when installing the Media Conv erter Slide-in-Module(s) into the chassis. F ailure to observ e this caution could result in damage to, and subsequent fa ...

  • Transition Networks CPSMC0800-100 - page 8

    8 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules T ech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 2.2.3 Replacing the Media Converter Slide-in-Modules CA UTION: W ear a grounding device and obser ve electr ostatic discharge precau- tions when replacing Media Conv erter Slide-in-Module(s). F ailure to ob ...

  • Transition Networks CPSMC0800-100 - page 9

    9 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules T ech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 2.2 Management Modules Optional network management is provided b y SNMP software embedded in T ransition Networks P ointSystem ™ Management Module(s) that can be installed in the CPSMC0800-100 8-Slot chas ...

  • Transition Networks CPSMC0800-100 - page 10

    10 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules T ech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 2.2.2 Installing the Managment Modules CA UTION: W ear a grounding device and obser ve electr ostatic discharge precau- tions when installing the Management Module(s) in the 8-Slot chassis. F ailure to obs ...

  • Transition Networks CPSMC0800-100 - page 11

    11 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules 2.2.3 Replacing the Mangement Modules CA UTION: W ear a grounding device and obser ve electr ostatic discharge precau- tions when replacing Media Conv erter Slide-in-Module(s). F ailure to observ e this caution could result in damage to, and subsequent failure of, the Management Module(s). N ...

  • Transition Networks CPSMC0800-100 - page 12

    12 CPSMC0800-100 PointSystem ™ Chassis po wer supply 3 P ow ering the CPSMC0800-100 T he CPSMC0800-100 chassis can be powered through an A C or DC Po wer Supply . An optional auxilliary power supply , with Instant F ail Over protections, is also av ail- able. NO TE: The CPSMC0800-100 8-Slot c hassis does not hav e an ON/OFF switc h. • P ower up ...

  • Transition Networks CPSMC0800-100 - page 13

    13 CPSMC0800-100 PointSystem ™ Chassis po wer supply 3.2 Auxilliar y P ow er Supply T he CPSMC0800-100 can also be supplied with auxilliary power through the Auxilliary P ower Inlet, located on the bac k panel. T he External P ower Converter and additional power cord are sold separately . T o power the CPSMM0800-100 8-Slot c hassis through the A ...

  • Transition Networks CPSMC0800-100 - page 14

    14 CPSMC0800-100 PointSystem ™ Chassis chassis 4 CPSMC0800-100 Chassis 4.1 Installing the CPSMC0800-100 Chassis T he CPSMC0800-100 can be installed in a standard 19-inch rac k or on a table, shelf, or other stable surface. 4.1.1 Standard 19-inc h Rack Installation NO TE: The maximum recommended ambient temper ature (Tmra) for the 8-Slot chassis i ...

  • Transition Networks CPSMC0800-100 - page 15

    15 CPSMC0800-100 PointSystem ™ Chassis chassis T o install the CPSMC0800-100 8-Slot c hassis into a standard 19-inch r ack: 1. Determine the preferred alignment of the 8-Slot c hassis in the rac k. NO TE: Installation bracket mounting screws are pro vided. Rackmount scre ws and clip nuts are NO T provided. 2. Locate six (6) installation brac ket ...

  • Transition Networks CPSMC0800-100 - page 16

    16 CPSMC0800-100 PointSystem ™ Chassis chassis 4.2 Cascade Option T he Management Module cascade option allows the network administr ator to con- nect up to eight (8) CPSMC0800-100 8-Slot chassis into one manageable stac k, pro- viding a single management source for up to 55 installed Media Conv erter devices. T o create the cascade option, the C ...

  • Transition Networks CPSMC0800-100 - page 17

    17 CPSMC0800-100 PointSystem ™ Chassis chassis T o cascade two or more CPSMC0800-100 8-Slot c hassis: 1. Locate one (1) T ransition Networks CPSMC0800-100 Management Module cas- cade cable (with RJ-45 connectors installed at both ends) for each set of tw o (2) chassis to be cascaded. NO TE: T ransition Networks Management Module cascade cables ar ...

  • Transition Networks CPSMC0800-100 - page 18

    18 CPSMC0800-100 PointSystem ™ Chassis chassis T ech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 4.4 Oper ation Daily operation of the CPSMC0800-100 8-Slot c hassis requires no network admin- istrator acti vity except for the occasional monitoring of the status LED indicators on the installed Media Converter S ...

  • Transition Networks CPSMC0800-100 - page 19

    19 CPSMC0800-100 PointSystem ™ Chassis SNMP T ech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 5 SNMP Agent in the Management Module Both Management Modules (CPSMM-120 and (CPSMM-200) ha ve an SNMP (Simple Network Managment Protocol) Agent installed in the module that allows remote managment of networked de ...

  • Transition Networks CPSMC0800-100 - page 20

    20 CPSMC0800-100 PointSystem ™ Chassis SNMP T ech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 RJ-45 Ethernet™ Port T he RJ-45 Ethernet™ P ort allows the network administrator to manage the CPSMC1800-100 8-Slot chassis via a remote Netw ork Management Station (NMS) in one of two w ays: 1. Using the T ra ...

  • Transition Networks CPSMC0800-100 - page 21

    21 CPSMC0800-100 PointSystem ™ Chassis troubleshooting 6 F ault Isolation and Correction 1. Are ANY of the POWER LEDs on any of the Slide-in-Modules illuminated; AND/OR are the fans oper ating? YES • T he chassis is recei ving power . Proceed to the next step. NO • Ensure all power supply cables for proper connection. • Ensure the AC recept ...

  • Transition Networks CPSMC0800-100 - page 22

    22 CPSMC0800-100 PointSystem ™ Chassis T ech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 T echnical Specifications F or use with T ransition Networks Model CPSMC0800-100 or equi valent. Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subc hapter J applicable at the date of manufac ...

  • Transition Networks CPSMC0800-100 - page 23

    23 CPSMC0800-100 PointSystem ™ Chassis T ech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 Cable Specifications Null Modem Cable T he Null Modem Cable is used for connecting a terminal or terminal emulator to the Management Module’ s DB-9 connecdtor to access the command-line interface. T he table below sh ...

  • Transition Networks CPSMC0800-100 - page 24

    24 CPSMC0800-100 PointSystem ™ Chassis Contact Us Technical Support T ec hnical support is a vialable 7:00 AM - 6:00 PM CST (GMT -6:00) United States: 1-800-260-1312 International: 00-1-952-941-7600 Transition Now Chat liv e wia the W eb with a T ransition Networks T ec hnical Support Specialist. Log onto www .tr ansition.com and click the T rans ...

  • Transition Networks CPSMC0800-100 - page 25

    25 CPSMC0800-100 PointSystem ™ Chassis W arr anty Limited Lifetime Warranty Effectiv e for Products Shipped May 1, 1999 and After . Every T ransition Networks' labeled product purc hased after May 1, 1999 will be free from defects in material and workmanship for its lifetime. T his warranty co vers the original user only and is not transfera ...

  • Transition Networks CPSMC0800-100 - page 26

    26 CPSMC0800-100 PointSystem ™ Chassis ty product(s) back to the customer (an y and all customs charges, tariffs, or/and taxes are the customer's responsibility). Before making any non-w arranty repair , T ransition Networks requires a $200.00 charge plus actual shipping costs to and from the customer . If the repair is greater than $200.00, ...

Produzent Transition Networks Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts Transition Networks CPSMC0800-100 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Transition Networks
- Bedienungsanleitungen CPSMC0800-100
- Produktkarten Transition Networks
- Informationsbroschüren
- oder Energieetiketten Transition Networks CPSMC0800-100
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Transition Networks CPSMC0800-100.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Transition Networks CPSMC0800-100, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Transition Networks CPSMC0800-100. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Transition Networks CPSMC0800-100 ansehen.

Die komplette Bedienungsanleitung des Geräts Transition Networks CPSMC0800-100, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Transition Networks CPSMC0800-100 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Transition Networks CPSMC0800-100 verständlich ist.

Eine gänzliche Bedienungsanleitung von Transition Networks sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Transition Networks CPSMC0800-100 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Transition Networks CPSMC0800-100 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Transition Networks CPSMC0800-100, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Transition Networks CPSMC0800-100 - die uns die ersten Schritte während der Nutzung von Transition Networks CPSMC0800-100 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Transition Networks CPSMC0800-100 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Transition Networks CPSMC0800-100 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Transition Networks CPSMC0800-100?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Transition Networks CPSMC0800-100 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Transition Networks CPSMC0800-100 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)