Bedienungsanleitung Monessen Hearth DSSNVMB

28 Seiten 0.79 mb
Download

Zur Seite of 28

Summary
  • Monessen Hearth DSSNVMB - page 1

    READ AND SA VE THESE INSTRUCTIONS MODELS: DSSNVMB DSSPVMB UNVENTED GAS STEEL ST OVE INST ALLA TION AND OPERA TING INSTRUCTIONS This is an unvented gas-fired heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to page 8. W ARNINGS If the inf orma tio n i ...

  • Monessen Hearth DSSNVMB - page 2

    2 46D0550 46D0550 3 CONTENTS Important Safety Information .......................... 3 Product Features .............................................. 5 Getting Started.................................................. 6 Product Specifications..................................... 7 Ignition Controls ............................................ 7 Pi ...

  • Monessen Hearth DSSNVMB - page 3

    2 46D0550 46D0550 3 9. The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFP A54. 1 0 . This unit complies with ANSI Z21.11.2-2001 Un vented Heaters. 11. Do not install heater in a bathroom or bedroom. 12. Correct installation of the ceramic ber logs, proper location o ...

  • Monessen Hearth DSSNVMB - page 4

    4 46D0550 46D0550 5 IMPORT ANT SAFETY INFORMA TION Continued fr om page 3 15. This is an un vented gas-red heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate comb ustion and ventilation air must be pro- vided. See page 8. 16. Keep room area clear and free from combustible materi- als, gasoline and other ...

  • Monessen Hearth DSSNVMB - page 5

    4 46D0550 46D0550 5                                           PRODUCT FEA TURES Off/Pilot/On Knob Hi/Lo Knob Door Figure 1 - Cast Iron Stove Optional Remote Receiver On/Off Switch Optional Blower Optional Thermostat ...

  • Monessen Hearth DSSNVMB - page 6

    6 46D0550 46D0550 7 GETTING ST ARTED MAKE SURE YOU HA VE RECEIVED ALL P ARTS: Check your packing list to verify that all listed parts ha ve been recei ved. Y ou should have the follo wing: • Steel Stove with Burner Assembly • Installation/Operating Instructions • Ceramic ber logs Milli volt controlled heater designed to be operated with op ...

  • Monessen Hearth DSSNVMB - page 7

    6 46D0550 46D0550 7 PRODUCT SPECIFICA TIONS NA TURAL GAS NOTE: An external regulator is required to reduce supply pressure to a maximum of 10 1 / 2 " w .c. on Natural Gas systems operating at higher pressure. MILLIVOL T PRESSURE Regulator Pressure Setting: 3.5" w .c. Pilot Regulator: 3.5" w .c. Gas Inlet Pressure: Max. 10 1/2" w ...

  • Monessen Hearth DSSNVMB - page 8

    8 46D0550 46D0550 9   � CODES Adhere to all local codes or , in their absence, the latest edition of THE NA TION AL FUEL GAS CODE ANSI Z223.1 or NFP A54 which can be obtained from… American National Standards Institute, Inc. or National Fire Pr otection Association, Inc. 1430 Broadway Batterymarch Park Ne w Y ork, NY 10018 Quincy , MA 022 ...

  • Monessen Hearth DSSNVMB - page 9

    8 46D0550 46D0550 9   The follo wing formula can be used to determine the maximum heater rating per the denition of unconned space: BTU/Hr = (L 1 + L 2 ) Ft x (W) Ft x (H) Ft 50 Consider two connecting rooms with an open area between, with the follo wing dimensions: L 1 = 15 1 / 2 Ft., L 2 = 12 Ft., W = 12 Ft., H = 8 Ft. BTU/Hr = (15 1 ...

  • Monessen Hearth DSSNVMB - page 10

    10 46D0550 46D0550 1 1                             ...

  • Monessen Hearth DSSNVMB - page 11

    10 46D0550 46D0550 1 1 Pipe Coupling T o Heater V alve Gas Supply Inlet CONNECTING THE GAS NOTICE: A qualified gas appliance installer must connect the heater to the gas supply . Consult all local codes. IMPORT ANT : Hold heater v alve rmly with a wrench to pre vent mo vement when connecting to inlet pipe. Manual Shutoff V alve Pipe Stainless Fl ...

  • Monessen Hearth DSSNVMB - page 12

    12 46D0550 46D0550 13                      CHECKING GAS PRESSURE AND CONNECTING REMOTE RECEIVER The heater gas inlet connection is 3/8" NPT at the valve. The inlet is located on left side of sto ve. Remo ve front control plate to better access the inlet. When tightening up the join ...

  • Monessen Hearth DSSNVMB - page 13

    12 46D0550 46D0550 13 ELECTRICAL WIRING (MILLI-VOL T) The milli-volt v alve is a self-po wered combination gas control THA T DOES NOT REQUIRE 1 10 V AC T O OPERA TE. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. CAUTION On/Off Switc ...

  • Monessen Hearth DSSNVMB - page 14

    14 46D0550 46D0550 15                                          Figure 9 - Installing T -Stat Sensor and Control Knob T -Stat Sensor Wiring Harnesses Screws Knob INST ALLING THERMOST A T SENSOR (OPTION SOLD SEP ARA TEL Y) 1. ...

  • Monessen Hearth DSSNVMB - page 15

    14 46D0550 46D0550 15                                        4. Remove adhesi ve backing from plastic clip. Press clip to bottom of v alve. Clip thermo bulb into plastic clip. See F igur e 10. 5. Reattach faceplate. ...

  • Monessen Hearth DSSNVMB - page 16

    16 46D0550 46D0550 17 DO NOT sprinkle volcanic rocks on the logs or around the pilot. This may cause sooting. During initial operation of the new heater , burning logs will give off a paper burning smell and orange flames will be present. Simply open the windows for a few hours to vent the odor . Log #4 Log #2 Log #1 Log #3 Back Pins Front Pins LOG ...

  • Monessen Hearth DSSNVMB - page 17

    16 46D0550 46D0550 17 Glowing Embers Figure 15 - Correct appearance of Embers and Rear Flame FLAME AP PEARANCE Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the ames visually during operation. CHECKING PILOT FLAME The pilot flame must always be present ...

  • Monessen Hearth DSSNVMB - page 18

    18 46D0550 46D0550 19                                             Figure 16 - Location of Control Knobs and Switch on Milli-volt Unit A. This appliance is equipped with an ignition de vice which automatically lights ...

  • Monessen Hearth DSSNVMB - page 19

    18 46D0550 46D0550 19                                        OPERA TING INSTRUCTIONS 1. STOP! Read the safety information label. 2. Make sure the manual shutof f v alve is fully open. 3. This gas log set is equipped ...

  • Monessen Hearth DSSNVMB - page 20

    20 46D0550 46D0550 21 1. Open stove door . Remo ve any items necessary for easy access to the pilot (for example: logs, screens, etc.). 2. Follo w appropriate lighting instructions found previously . Light a match and hold the ame to the end of the pilot and ignite the pilot. 3. After control knob has been released and pilot stays lit, reinstall ...

  • Monessen Hearth DSSNVMB - page 21

    20 46D0550 46D0550 21     REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER. Item Description Qty 1 Back Log 1 44D101 1K 2 Middle Log 1 46D0542K 3 Front Log 1 44D1012K 4 T op Log 1 44D1013K REPLACEMENT P ARTS LIST Failure to position the parts in accordance with these diagrams or failure to use only parts specifically a p p r o ...

  • Monessen Hearth DSSNVMB - page 22

    22 46D0550 46D0550 23                REPLACEMENT P ARTS Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance m a y r e s u l t i n p r o p e r t y d a m a g e o r personal injury . W ARNING BURNER ...

  • Monessen Hearth DSSNVMB - page 23

    22 46D0550 46D0550 23 REPLACEMENT P ARTS LIST REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER. DSS Models BURNER ASSEMBL Y Accessories Flex Connector Flexcon 30 Wall Switch Kit MVWS Wall Thermostat Kit MVWTS Hand Held Remote RCM Hand Held Thermostat Remote RCT Thermostat Control Sensor TS Gold Door GDSS Blower BLOS Item Description Qty Na ...

  • Monessen Hearth DSSNVMB - page 24

    24 46D0550 46D0550 25 OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot. App li a nc e p ro du c es u nw an t ed odors. Appliance shuts off during use. Ga s odor ev en wh en co ntr ol kn ob is in OFF position. When ignitor button is pressed, there is spark at ODS pilot, but no ignition. POSSIBLE CAUSE 1. Ignitor electr ...

  • Monessen Hearth DSSNVMB - page 25

    24 46D0550 46D0550 25 OBSERVED PROBLEM ODS/pilot lights, but flame goes out when control knob is released. Bur ner does no t l ight afte r OD S/ pilot is lit. Burner backres during com- bustion. Slight smoke or odor during initial operation. Logs appear to smoke after ini- tial operation. Heater produces a whistling noise when bur ner is lit. No ...

  • Monessen Hearth DSSNVMB - page 26

    26 46D0550 46D0550 27 NOTES ...

  • Monessen Hearth DSSNVMB - page 27

    26 46D0550 46D0550 27 NOTES ...

  • Monessen Hearth DSSNVMB - page 28

    July 2002 46D0550 • Rev . 1 LIMITED LIFETIME W ARRANTY POLICY LIFETIME W ARRANTY The follo wing components are warranted for life to the original owner , subject to proof of purchase: Firebox, Combustion Chamber , Heat Exchanger , Grate and Stainless Steel Burners. FIVE YEAR W ARRANTY The following components are warranted ve (5) years to the ...

Produzent Monessen Hearth Kategorie Stove

Dokumente, die wir vom Produzenten des Geräts Monessen Hearth DSSNVMB erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Monessen Hearth
- Bedienungsanleitungen DSSNVMB
- Produktkarten Monessen Hearth
- Informationsbroschüren
- oder Energieetiketten Monessen Hearth DSSNVMB
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Monessen Hearth DSSNVMB.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Monessen Hearth DSSNVMB, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Monessen Hearth DSSNVMB. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Monessen Hearth DSSNVMB ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Monessen Hearth DSSNVMB, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Monessen Hearth DSSNVMB hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Monessen Hearth DSSNVMB verständlich ist.

Eine gänzliche Bedienungsanleitung von Monessen Hearth sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Monessen Hearth DSSNVMB bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Monessen Hearth DSSNVMB befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Monessen Hearth DSSNVMB, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Monessen Hearth DSSNVMB - die uns die ersten Schritte während der Nutzung von Monessen Hearth DSSNVMB erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Monessen Hearth DSSNVMB hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Monessen Hearth DSSNVMB im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Monessen Hearth DSSNVMB?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Monessen Hearth DSSNVMB nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Monessen Hearth DSSNVMB hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)