    www.xan trex.com Smart choice for power Inverter Stacking Contr o l Series (ISC-S) Cable Installati on Guide ...

  • Xantrex Technology power Inverter Stacking - page 2

    ...

  • Xantrex Technology power Inverter Stacking - page 3

    Inverter Stacking Control Series (ISC-S) Cable Installation Guid e ...

  • Xantrex Technology power Inverter Stacking - page 4

    About X antr ex Xantre x T echn ology In c. is a worl d-leading suppl ier of advanced power ele c troni cs and controls with prod ucts from 50 watt mobi le un its to one MW util ity-sca le sys te ms for wind, sol ar , batt eries, fuel cel ls, microtu rbines, and bac kup power app licat ions in both gri d-connec te d a nd s tand-a l on e s y s t ems ...

  • Xantrex Technology power Inverter Stacking - page 5

    975-0059-01-01 R e v A iii About This Guide Pu rpose The purpose of this Ins ta lla tio n Guide i s to provi de explana tions and procedur es for i nstalling the Inve r ter Sta c king Contr ol – Seri es Cable and provides inform a t ion r e ga rding sta c king two identic a l Sine W ave Plus inverte r s . Scope The Guide provide s safety gui deli ...

  • Xantrex Technology power Inverter Stacking - page 6

    About T hi s Guide iv 975-0059-01-01 Re v A C onv ent ion s U sed The f ollowing conventio ns are use d in this guide. Abbrev iation s and Acr onyms The following a crony m s and abbrev iations are used in this guide: R elat ed Inf orm atio n Y ou can find more informatio n a bout Xa ntrex T echnolog y Inc. a s well as its products a nd servi c e s ...

  • Xantrex Technology power Inverter Stacking - page 7

    975-0059-01-01 R e v A v Important Safety Instructions 1. Before installi ng and using the ISC- S cab le , r ead al l i nstr uction s and cautiona ry information in thi s gui de . 2. Do not expose the ISC- S cab le to rain, snow , spr a y , or wa ter . 3. Use only atta c hm en ts recommended or sold by the manufa c t ur e r . Doing otherwis e may r ...

  • Xantrex Technology power Inverter Stacking - page 8

    vi ...

  • Xantrex Technology power Inverter Stacking - page 9

    975-0059-01-01 R e v A vi i Im portan t Safety Instr uction s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - v 1 Introduction Stac k ing I nverters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 –2 The I SC-S Cab l e - - - - - - - - - - - - - - ...

  • Xantrex Technology power Inverter Stacking - page 10

    viii ...

  • Xantrex Technology power Inverter Stacking - page 11

    975-0059-01-01 R e v A ix Figu re 1-1 Off- Grid A pplic ations w ith S eries-S t ack ed In verter s- - - - - - - - - - - - - - - - - - - - - - - - - 1 –3 Figu re 1-2 On-G rid Ap plicat ions w ith Ser ies-s t ack ed In v ert ers - - - - - - - - - - - - - - - - - - - - - - - - - 1– 4 Figure 1-3 I nver te r Stackin g Control – Ser ies Cabl e ( I ...

  • Xantrex Technology power Inverter Stacking - page 12

    x ...

  • Xantrex Technology power Inverter Stacking - page 13

    1 Introducti on Chapter 1, “ Introduction” provides information on stac king of Sine W ave Plus inverters. The following topics are covered in this chapter . For t his topic : See: “S tacking Inve rters” page 1–2 “T he ISC-S Cable” page 1–5 ...

  • Xantrex Technology power Inverter Stacking - page 14

    Introduction 1–2 975-0059-01-01 Re v A St acking Invert ers T wo iden tic al , seri es-s ta cked , invert er s can b e co nne ct ed tog eth er fo r the foll owing purposes. • The voltage ou tput of a singl e inve r ter is ins uf fic ie nt to powe r the 240 V ac loads attached to the syste m; • Multi-wir e branc h c ircu its exists in the curr ...

  • Xantrex Technology power Inverter Stacking - page 15

    Stackin g Inverters 975-0059-01-01 R e v A 1–3 Figur e 1-1 Off-Grid Applications wit h Series-Stack ed Inverters ...

  • Xantrex Technology power Inverter Stacking - page 16

    Introduction 1–4 975-0059-01-01 Re v A Figur e 1-2 On-Grid Applicat ions with Series- s t acked Inver t er s ...

  • Xantrex Technology power Inverter Stacking - page 17

    T he IS C- S C ab le 975-0059-01-01 R e v A 1–5 The IS C-S Ca b l e Req u ired access ory cable Sta cking two i dentical inver ters r equires t he use of the Inverter St ackin g Control – Seri es Cab le ( ISC-S ca ble ). T he I SC-S cab le is a spe cial ca ble s pecifica lly desig ne d f or serie s-stacking two identic al i nverters. It consis ...

  • Xantrex Technology power Inverter Stacking - page 18

    1–6 What it does The ISC -S cabl e provides communicat ion between the two s ta cked inverters for two purpos e s. • It provide s synchronization inf ormation for invert ing a nd cha r gi ng. • It provide s a method for one inver t e r dete c t ing a n e rror conditio n t o send a shut- down command to the other inv erte r , to prevent a 240V ...

  • Xantrex Technology power Inverter Stacking - page 19

    2 Installation Chapte r 2 , “Installation” provides information on installing the DC wiring, AC W iring, and the ISC-S f or Sine W ave Plus inverters. The following topics are covered in this chapter . “DC W iring” page 2–2 “AC W iring - Genera l” page 2–6 “AC W iring - Spec ifi c” page 2–8 “Con ne c ting the ISC- S Cable ? ...

  • Xantrex Technology power Inverter Stacking - page 20

    Insta llation 2–2 975-0059-01-01 Re v A DC Wiring The success of series- sta cked , inver te r syst e m s i s depende nt on the quali ty a nd mainte na n c e of the DC connectio ns. S tacked inver ter s ets are far les s for gi ving to long, unde r sized, uneven, and/or poo r conne ct ions than a r e single invert e r s. Bat ter y Requi rement s ...

  • Xantrex Technology power Inverter Stacking - page 21

    DC Wiring 975-0059-01-01 R e v A 2–3 G round ing Seri es-sta ck ed In vert ers T o groun d series -stack ed inv erters: 1. Connect th e ground bond in the DC di sc o nne c t between the inverters a nd the batt e r ie s to the primary groundin g e le ctr ode, in accor dan ce w ith loc al and nation a l elect rica l codes. 2. Connect an appropr ia ...

  • Xantrex Technology power Inverter Stacking - page 22

    Insta llation 2–4 975-0059-01-01 Re v A Con necting t he Batt ery Bank to t he Invert ers The following in structions are ill ustrated in Figure 2- 3 . T o conn ect th e batte ry (or bat tery ba nk) to the inver ters: 1. Connect POSITIVE cable s: a) one c able from th e batte ry P OSITIVE t ermina l to a circuit breaker i n the DC di sc onnect (t ...

  • Xantrex Technology power Inverter Stacking - page 23

    DC Wiring 975-0059-01-01 R e v A 2–5 Figur e 2-3 DC Conne ctions fo r Dual Inver ters , Series -stac k ed DC Condui t L2 In v erter – + 12 Vo lt Ba t t er y 200 A h – + 12 Vo lt Batte r y 200 A h + – 12 Vo lt Ba t t er y 200 A h Se ri es S t ring 1 Se ri es S t ring 2 DC C ond uit for L1 I nverter 24 Vd c/ 2 0 0 Ah 24 V dc / 200 A h – + 1 ...

  • Xantrex Technology power Inverter Stacking - page 24

    Insta llation 2–6 975-0059-01-01 Re v A A C W iring - Gener al Be sure to use t he re commende d wire and disconnect siz e as r e c ommen ded in the Owner’ s M a nua l for the Sine W ave Plus Inverte r . Inverte r A C Distrib ution P ane l (Sub-P anel) W iring (if use d) An Invert e r AC Dist ributi on Pa nel ( r e ferr ed to here as the inve r ...

  • Xantrex Technology power Inverter Stacking - page 25

    AC W iri ng - G en eral 975-0059-01-01 R e v A 2–7 Neut ral Bonding The HOT output of each inver ter provide s 120 V a c to ne ut r a l. The volt a ge betwee n the HOT outputs f r om the L1 a nd L2 inverter is 2 40 V ac when the ISC-S cable is used. When using a serie s-sta cked, i nve r t e r config ur a tion, it is importa nt to pro vide a neut ...

  • Xantrex Technology power Inverter Stacking - page 26

    Insta llation 2–8 975-0059-01-01 Re v A A C W iri ng - Spe cifi c The following AC connect ions are speci f i c to inst a l ling the S ine W ave P lus Inver ter/char ge r s in a serie s-stacked configur a t ion for off-grid a nd o n-g rid appli c a tions. Off-G rid AC Wirin g for Si ne W a ve Plu s Inve rters The f ollowing st eps ar e ill ustrat ...

  • Xantrex Technology power Inverter Stacking - page 27

    A C Wiri ng - Spe cifi c 975-0059-01-01 R e v A 2–9 Figur e 2-4 A C W iri ng fo r Seri es-stac k ed SW Plus In verters Of f Grid AC TE R MIN AL BLO CK INV OUT NEU TRAL O UT NEU TRAL 2 NEU TRAL 1 AC1 G R ID AC2 G E N AC GROUN D BAR (i n si de) (L 2) AC T ER MIN AL BLO CK IN V OU T NE UTRAL OUT NE UTRAL 2 NE UTRAL 1 AC1 G RID AC2 G EN Si ne Wa v e ...

  • Xantrex Technology power Inverter Stacking - page 28

    Insta llation 2–10 975-0059-01-01 Re v A On-Gr id A C Wirin g for Si ne W a ve Plus Invert ers Prepar e the AC wiring as follo w s for an on-gr id applic at ion using ser ie s-sta cked, Sine W ave P l us I nv e r ter /c har ge rs . The following ste ps are illust rated in Figure 2-5 . Groundi ng 1. Connect G RO UND (gre en) w i res : a) from the ...

  • Xantrex Technology power Inverter Stacking - page 29

    A C Wiri ng - Spe cifi c 975-0059-01-01 R e v A 2–11 Figur e 2-5 A C W iri ng fo r Seri es-stac k ed SW Plus I n ve rter s On Gri d AC TERMINAL BLOCK INV O UT NEUT RA L OUT NEUT RA L 2 NEUT RA L 1 AC1 G R ID AC2 G E N AC T ERMINAL BLOCK IN V O U T NE UTRA L OUT NE UTRA L 2 NE UTRA L 1 AC 1 GR ID AC 2 GEN Sin e W ave Plus Inver ter/ Ch arger 120/2 ...

  • Xantrex Technology power Inverter Stacking - page 30

    Insta llation 2–12 975-0059-01-01 Re v A Gen erator A C W i ri n g t o Seri es- stacked Inve rters The f ollowing wiring diagrams show the AC wi r ing fr om an AC gener a tor to the inverte rs. The following pr oc edures a re illus trated in Figure 2-6 . W ith a ge nerator disco nne c t swit c h T o install the AC w i ring from a generator with a ...

  • Xantrex Technology power Inverter Stacking - page 31

    A C Wiri ng - Spe cifi c 975-0059-01-01 R e v A 2–13 Figur e 2-6 Gener ator Wiring to Series -stack ed SW Plus Inverters L1 L2 NEUTRAL GRO UND AC T ER MINAL BL O CK IN V OU T NE UTRAL OU T NE UTRAL 2 NE UTRAL 1 AC1 GRID AC2 GEN AC T ERM INAL BL O CK IN V OU T NEUT RAL OU T NEUT RAL 2 NEUT RAL 1 AC1 GRID AC2 GEN Sine Wav e Plus Inve r t er/Cha rge ...

  • Xantrex Technology power Inverter Stacking - page 32

    Insta llation 2–14 975-0059-01-01 Re v A Wirin g for a 240 V a c-Onl y Inp ut So u rce A 240 V ac source does not all ow for the conne ct ion to the in put of a 120 V ac inverte r as no neu tral line is supplied from the utili ty or ge nerator . In or de r t o us e stacke d inverters, a neu tral li ne must b e added by using a ce nter - tapped au ...

  • Xantrex Technology power Inverter Stacking - page 33

    A C Wiri ng - Spe cifi c 975-0059-01-01 R e v A 2–15 Figur e 2-7 A C W iri ng for a 240 V ac-Only Inpu t Sou rce AC T ER MINAL BL OCK INV O UT NE UTRAL OUT NE UTRAL 2 NE UTRAL 1 AC1 GRID AC2 GEN Sin e Wave Plus In ver ter/ Ch arger AC T ERM INA L BL OCK INV OUT NEUTRAL O UT NEUTRAL 2 NEUTRAL 1 AC1 GRID AC2 GEN Sin e W ave Plu s In ver ter/C h arg ...

  • Xantrex Technology power Inverter Stacking - page 34

    Insta llation 2–16 975-0059-01-01 Re v A C onne ct ing the ISC- S Cabl e The I SC-S Cabl e c onnects t o the S tacking P or t on the AC end of the Sine W a ve Plus Inve r t e r /c harger . The St acking P ort is a 25-pin rec ept acle for the 25-pi n D-conne c t or on the ISC-S Cabl e . Once the connector is in plac e , it is secure d by two sc re ...

  • Xantrex Technology power Inverter Stacking - page 35

    Connecting the ISC-S Cable 975-0059-01-01 R e v A 2–17 Figur e 2-10 Th e ISC-S Cable Connec ted to Dual Sine W ave Plus Inverter s Connect one end of I SC-S Cable to the St acki ng Port of the L1 inve r ter. Connect t he other end of ISC-S Cabl e t o t h e S t ac king Port of the L2 inv er t er. CA UTION; D amag e to Loa ds Until t he units are t ...

  • Xantrex Technology power Inverter Stacking - page 36

    2–18 ...

  • Xantrex Technology power Inverter Stacking - page 37

    3 Op eratio n Chapter 3, “ Operati on ” contains information on s tartup and f unct ional testing procedures f or series-stacked Sine W a ve Plus inverters. The following topics are covered in this chapter . For t his topic : See: “S tart-up and T esting” page 3–2 “S et ting Changes” page 3–4 ...

  • Xantrex Technology power Inverter Stacking - page 38

    Operat ion 3–2 975-0059-01-01 Re v A Start -up and T esti ng S tacked inve rters must operat e together i n order to provide t he 120/24 0 V ac to the loads . The ISC-S cable ensures the output f r om each inve r t e r is 180 degre es out-o f -phase f or ope ratin g 240 V ac loads. T o star t up and te s t th e inverte rs: 1. Ensure the circ uit ...

  • Xantrex Technology power Inverter Stacking - page 39

    Start-up and T esting 975-0059-01-01 R e v A 3–3 Figur e 3-1 T estpoints for Confir ming V oltages L1 L2 NE UTRAL GROUND LE G E ND GRO U ND NE UTRA L H OT L1 H OT L2 T o 240 V a c Lo ad s AC Dis t ribu ti on P a ne l (Su b - p an el ) 120/240 V ac To 120 Vac Loa ds To Ma in Ut ilit y Pa nel Gro un d To L2 Inv ert er To L2 Inv ert er To L1 Inv ert ...

  • Xantrex Technology power Inverter Stacking - page 40

    Operat ion 3–4 975-0059-01-01 Re v A Setti ng Ch ange s When oper a t ing a Sine W ave Plus in a series-sta c k e d c onf i guration, the f ollo w i ng sett ings m us t b e changed f or prope r ope r ation. See the Owner ’ s Manual for the Sine W ave Plus for deta iled inst r uc ti ons on accessi ng and ch a nging the sett ings using the Invert ...

  • Xantrex Technology power Inverter Stacking - page 41

    Setti ng Chang es 975-0059-01-01 R e v A 3–5 Automatic Generator Equalize Char ging If the i nverters a re se t t o automati call y char ge the batt eries using the gene rator , the equaliz e proc ess w i ll begin during the next, aut omatic ally started, ge ne r ator r u n period. When the equa lizing process has completed, the gene rator aut om ...

  • Xantrex Technology power Inverter Stacking - page 42

    3–6 ...

  • Xantrex Technology power Inverter Stacking - page 43

    975-0059-01-01 R e v A WA–1 W arranty and R eturn Informatio n Wa r r a n t y Wha t does this warr anty co ver? This Limit ed W arranty is provi ded by Xa n trex T echnology , Inc. ("Xantr ex") and cov ers defect s in workmanshi p and materia ls in your Invert e r S t acking Contr ol – S e ries Cable . This wa rra nty perio d lasts fo ...

  • Xantrex Technology power Inverter Stacking - page 44

    War r anty and Return WA–2 975-0059- 01-01 Rev A Wha t do es thi s warr a nty no t cov er? T his L imited W arranty does not cove r normal wea r and tear of the pr oduc t or cos t s re l a t ed to the removal, insta ll ation, or trou bleshooti ng of the c us tom er's e l e c trical syst ems. This warran ty doe s not appl y to and Xantrex wil ...

  • Xantrex Technology power Inverter Stacking - page 45

    War r anty and Return 975-0059-01-01 R e v A WA–3 R etu rn M ate rial Autho riz atio n P ol icy Before re t urning a product dir ectly to Xantr e x you m ust obta in a Retur n Ma terial Auth orizat ion (RMA) number and the c orre c t f a c tory "Ship T o" addre s s. P r oduc ts m u st also be shipp ed prepaid. Pro duct shipmen ts will b ...

  • Xantrex Technology power Inverter Stacking - page 46

    War r anty and Return WA–4 975-0059- 01-01 Rev A Inf o r matio n About Y our System As soon as you op e n your Inverter S tacking Co ntrol – Series Cabl e p ac kage , re c ord the fol lowing inform a tion and be sure to kee p your proo f of pur cha s e . If you need t o conta ct Cus tomer Service , ple ase r ecord th e follo wing deta il s befo ...

  • Xantrex Technology power Inverter Stacking - page 47

    240 V ac-Only In put Sourc e 2–14 Abbr evi ations an d Acronym s iv AC Wi ring - Gen e ra l 2–6 AC Wi ring - Spe c if i c 2–8 Batt ery Re quiremen ts 2–2 Batt ery-Ban k C onfigura tion 2– 2 Bulk and Fl oa t Ch a rgi ng Parame ters 3–4 Connec ting the Batte ry B ank 2–4 Cu st omer Serv ice prepari ng to c a ll WA–4 DC Wi ring 2–2 G ...

  • Xantrex Technology power Inverter Stacking - page 48

    IX- 2 ...

  • Xantrex Technology power Inverter Stacking - page 49

    ...

  • Xantrex Technology power Inverter Stacking - page 50

    Xant r e x Technology I nc. 1 800 670 0707 Tel toll fr ee NA 1 360 925 5097 Tel direct 1 800 994 7828 Fax t ol l free NA 1 360 925 5143 Fax direct customerserv ice@xantrex.com www.xant rex .com PN 975-0059-01-01 PC Printed in USA ...

Produzent Xantrex Technology Kategorie Portable Generator

Dokumente, die wir vom Produzenten des Geräts Xantrex Technology power Inverter Stacking erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Xantrex Technology
- Bedienungsanleitungen power Inverter Stacking
- Produktkarten Xantrex Technology
- Informationsbroschüren
- oder Energieetiketten Xantrex Technology power Inverter Stacking
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Xantrex Technology power Inverter Stacking.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Xantrex Technology power Inverter Stacking, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Xantrex Technology power Inverter Stacking. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Xantrex Technology power Inverter Stacking ansehen.

Die komplette Bedienungsanleitung des Geräts Xantrex Technology power Inverter Stacking, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Xantrex Technology power Inverter Stacking hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Xantrex Technology power Inverter Stacking verständlich ist.

Eine gänzliche Bedienungsanleitung von Xantrex Technology sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Xantrex Technology power Inverter Stacking bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Xantrex Technology power Inverter Stacking befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Xantrex Technology power Inverter Stacking, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Xantrex Technology power Inverter Stacking - die uns die ersten Schritte während der Nutzung von Xantrex Technology power Inverter Stacking erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Xantrex Technology power Inverter Stacking hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Xantrex Technology power Inverter Stacking im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Xantrex Technology power Inverter Stacking?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Xantrex Technology power Inverter Stacking nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Xantrex Technology power Inverter Stacking hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)