  • Raypak D2 - page 1

    INST ALLA TION & OPERA TING INSTR UCTIONS CA T ALOG NO. 6000.57F Effective: 12-02-08 Replaces: 5-20-08 P/N 241086 Rev . 7 WARNING: If these instructions are not followed exactly , a fire or explosion may result causing property damage, personal injury or death . FOR Y OUR SAFETY : Do not store or use gasoline or other flammable vapors and liqui ...

  • Raypak D2 - page 2

    2 Rev . 7 reflects the following: Changes to: The text in paragraph one of the V enting section on page 8. ...

  • Raypak D2 - page 3

    War nings 4 Pay Attention to These T erms 4 R eceiving Equipment 5 General Specifications 5 Installation 5 Mounting the Assembly 5 W iring a P ower V ent Assembly to an Appliance with IID Ignition 8 V enting 8 W iring Diag rams 10 182-260 H4/WH1 (Atmospheric) 10 181-261 H4/WH1 (Low NOx) 1 1 Sequence of Operation 13 Star t Up Pr ocedures 13 Draft Pr ...

  • Raypak D2 - page 4

    D ANGER: Indicates the presence of immediate hazards which will cause severe personal injury , death or substantial property damage if ignored. WARNING: Indicates the presence of hazards or unsafe practices which could cause severe personal injury , death or substantial property damage if ignored. CA UTION: Indicates the presence of hazards or unsa ...

  • Raypak D2 - page 5

    R eceiving Equipment On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the complete assembly from the carton if it is damaged report the damage to the carrier immediate- ly . Be ...

  • Raypak D2 - page 6

    6 7. Mount the Power V ent on the outer top. 8. Route the conduit harness of the Power V ent thru the outer top hole, around the adapter towards the back of the unit. Continue routing the harness thru the corner slot, which leads to open area behind the access panel. Finally , route only the wire harness thru the 7/8” grommet hole located on the ...

  • Raypak D2 - page 7

    7 U.S. Installations 1 Can adian I nstalla tions 2 A Clearance abov e grade, veran da, porch , deck, or balcony 1 ft ( 30 c m) 1 ft ( 30 c m) B Clearance to window or door that may be opened 4 f t ( 1.2 m) belo w o r to s ide of openin g; 1 foot (30 cm) above op ening 3 ft (91 c m) C Clearance to permanen t ly closed window ** D Ver tical clearan c ...

  • Raypak D2 - page 8

    8 W iring a P ow er V ent Assembl y to an Appliance with IID Ignition V enting The vent pipe must be the same size or one size larg- er than what is indicated. The D-2 Power V ent is capable of 360-degree discharge rotation and oper- ates with a positive vent static pressure and with a vent gas temperature less than 400°F . The total length of hor ...

  • Raypak D2 - page 9

    9 LEFT SIDE The D-2 Power V ent assembly includes a wire harness, shown in Fig. 6 below , which provides quick connec- tions with the respective controls in the heater control box. The harness is of suf ficient length to fit the appliance for which it is sized. Reference the wiring diagram supplied with each appliance for actual connections. Fig. 5 ...

  • Raypak D2 - page 10

    10 W iring Dia gr ams—182-260 H4/WH1 (Atmospheric) ...

  • Raypak D2 - page 11

    11 181-261 H4/WH1 (Lo w NOx) ...

  • Raypak D2 - page 12

    12 Dimensional Dat a 181 18.13 12.38 7.88 4.25 18 2 18.13 12.38 7.88 4.25 26 0 18.13 12.38 7.88 4.25 26 1 18.13 12.38 7.88 4.25 33 0 17.50 15.75 7.63 6.00 33 1 17.50 15.75 7.63 6.00 40 0 17.50 15.75 7.63 6.00 40 1 17.50 15.75 7.63 6.00 Model No. A B C D 181 18.13 12.38 7.88 4.25 182 18.13 12.38 7.88 4.25 260 18.13 12.38 7.88 4.25 261 18.13 12.38 7. ...

  • Raypak D2 - page 13

    13 Sequence of Operation On call for heat, the D-2 Power V ent fan (and appli- ance pump) start. When the flow switch circuits close, the ignition system consisting of an electronic spark module, pilot gas system and flame sensor , are ener- gized. When draft proving switch closes and all safety circuits are proven, the automatic main gas valves wi ...

  • Raypak D2 - page 14

    14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Call Out Description 181-261 331-401 1 Power V ent Relay 008784F 008784F 2 Power V ent Blower 008156F 008156F 3 Power V ent NO Pressure Switch 008062F 008135F 4 Elbow 4"-90° with Screen 010827F 010827F 5 Power V ent Flue Box 008682F 008683F 6 Power V ent Base Assembly 008684F 008685F 7 Power V ent Flue C ...

  • Raypak D2 - page 15

    15 ...

  • Raypak D2 - page 16

    ww w .raypa k . com Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A. ...

Produzent Raypak Kategorie Ventilation Hood

Dokumente, die wir vom Produzenten des Geräts Raypak D2 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Raypak
- Bedienungsanleitungen D2
- Produktkarten Raypak
- Informationsbroschüren
- oder Energieetiketten Raypak D2
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Raypak D2.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Raypak D2, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Raypak D2. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Raypak D2 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Raypak D2, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Raypak D2 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Raypak D2 verständlich ist.

Eine gänzliche Bedienungsanleitung von Raypak sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Raypak D2 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Raypak D2 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Raypak D2, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Raypak D2 - die uns die ersten Schritte während der Nutzung von Raypak D2 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Raypak D2 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Raypak D2 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Raypak D2?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Raypak D2 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Raypak D2 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)