    SERVICE MANUAL 3 4 00 HIGH EFFICIENCY STEREO POWER AMPLIFIER U.S.A. Yorkville Sound Inc. 4625 Witmer Industrial Estate Niagara Falls, New York 14305 USA Voice: (716) 297-2920 Fax: (716) 297-3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering, Ontario L1W-3Y8 CANADA Voice: (905) 837-8481 Fax: (905) 837-8746 Quality and Innovat ...

  • YORKVILLE 3400 - page 2

    1 AUDIOPRO AP-3400 SERVICE MANUA L M1012A “THE INPUT BOARD” The input board processes the audio signal from the input jacks to the voltage a mplifier board, (M1011A). Each channel consists of a ba lanced gain stage, defeatable b ass boost filter, and a preemphasis filter network. The balanced input, (XLR Jack) and unbal anced input (phone jack) ...

  • YORKVILLE 3400 - page 3

    2 VOLTAGE AMPLIFIER: The voltage ampl ifier amplifies the audio signal?s voltage fro m 4.8 volts peak ( at the output of U2) to approximen tly 97v peak which is required to dr ive the current amplifier boar d M1002A. M1 002A provides t he current req uired for the 97v peak signal t o drive 1200 w atts into 4 ohms ou t of the binding posts. Before t ...

  • YORKVILLE 3400 - page 4

    4 5 QUIESCENT CONDITION: This design is class A/B and t herefore the outpu t driver transis tors must be for ward biased to pr ovide low cross over distortion. In mos t class A/B des igns, a diode ch ain or VBE mult iplier is us ed to control the bias voltage and provide a means of adjust ing the bias. Th is design is dif ferent as there is n' ...

  • YORKVILLE 3400 - page 5

    6 The voltage betwee n the amplifier?s out put and test point 4 is approximate ly 14.7VDC derived from the v oltage drop across ZD3 @ ZD4. We ca ll this voltage the “float ing battery” because it floats on top of the output audio signal with poi nt 4 always being 1 4.7VDC greater than the peak of the output signal. Point 4 dr ives the gate of m ...

  • YORKVILLE 3400 - page 6

    8 EMS Circuit The Energy Mana gement System c ircuit only applies to North American lin e voltage pro ducts. A North Am erican AC receptacle can pr ovide 1850 w atts before the wal l breaker would trip, but how ca n a amplifier prov ide 2 x 1200 wat ts out when only 185 0 watts is ava liable out of the AC r eceptacle? A sinewave sourc e connected t ...

  • YORKVILLE 3400 - page 7

    10 STEP 3: POWER UP PROCE DURE WITHOUT M1002A BOARDS It is extremely important that y ou never power u p an AP3400 wit h the interconnec ting cablesb etween the circu it boards not connec ted. Time and possible further damage wi ll be reduced if you test M1011 A and M1002A boards separat ely. To do this yo u must use the M10 11A and M1002A test con ...

  • YORKVILLE 3400 - page 8

    Identifying Defective Boards in the AP-3000 & AP-3400 Please note: All boards used in the AP-3400 are designated with an `A' suffix (e.g. M1002A) and use bright red solder mask STEP 1: VISUAL INSPECTION OF FRONT PANEL AND FAN a) Check to see whether the green power LED is lit. If not, the amplifier has a power supply ( M1013 board), transf ...

  • YORKVILLE 3400 - page 9

    220R0 R51 6800u 80V C22 6800u 80V C23 T5 T3 T1 T4 6800u 80V C24 6800u 80V C25 T10 T9 T8 T7 T6 T2 249R:1% R5 BC550 Q1 BC550 Q4 BC560 Q2 BC560 Q3 2R2 R3 2R2 R4 150R R7 150R R15 4K7 R10 CW 4K7 LIN RT1 1n C2 470p C4 15K R8 249R:1% R9 249R:1% R19 15K R16 FLMPRF 39R R12 FLMPRF 39R R14 S G D N MTW10N40E Q5 S G D N MTP10N15L Q11 FLMPRF 22R1 R11 36K R13 10K ...

  • YORKVILLE 3400 - page 10

    820R R9 RED LD1 47p C2 47p C1 10K:1% R14 10K:1% R13 1/2 33078 U2 2 3 1 1u 16v C3 100K RV2 D2 D1 100K RV1 1K R2 BC550 Q3 330R R36 MS4 1 2 3 4 5 6 7 8 1/2 33078 U3 2 3 1 BF872 Q11 220K R10 100n C4 2u2 16v C5 D4 D3 1/2 33078 U3 6 5 7 A63 Q5 270R R17 113K0:1% R16 10k:1% R20 113K0:1% R15 27p C32 BC560 Q1 10K:1% R45 1/2 33078 U1 2 3 1 17K8:1% R3 5K36:1% ...

  • YORKVILLE 3400 - page 11

    SHEAR SHEAR ROUTE GAGE 0.01"/HOLE .020" .012" .008" .005" VCD .020" .012" .008" .005" SHEAR SHEAR .020" .012" .008" .005" 5.13 SOLDERSIDE M1011-5.10 BLANK SIZE=16.000"X11.050" M1011- RED YEL BLK WHT BLU POW SUP BOTTOM INPUT BOARD TOP TJH1 GUIDE ETCH EY16 F HS1 PART# HS2 PART ...

  • YORKVILLE 3400 - page 12

    TJH1 GUIDE ETCH EY16 F HS1 PART# HS2 PART# R60B 2_WATT 220K @R8 J1 J9 HS3 PART# D21B 4148 D21A 4148 1 _MW1 FUNCTION PART# Q19B MJE350 TP6 TP5 C22B @C1 300V 10P C23B @C1 300V 10P C22A @C1 300V 10P C23A @C1 300V 10P Q19A MJE350 Q18A MJE340 Q18B MJE340 C27B @C2 160V 10U C28B @C2 160V 10U C28A @C2 160V 10U C27A @C2 160V 10U R103 @R3 0.5W 15K R102 @R3 0 ...

  • YORKVILLE 3400 - page 13

    1/2 5532 U3 2 3 1 4M7 R14 16v 470n C7 OUT IN S1 1 2 3 1/2 5532 U3 6 5 7 17K8:1% R15 16v 150n C9 16v 47n C8 16v 100n C6 16v 68n C5 SRT CH_B_IN NO_GOLD JB2 1 2 3 4 5 6 NUTRIX BAL_IN JB1 1 3 2 1/2 33078 U1 2 3 1 1K R5 10K:1% R6 1K R1 10K:1% R2 14K0:1% R3 14K0:1% R7 470p C1 470p C2 100p C3 100p C4 EY2 WC1 5K6 R12 1R R4 7K5 R13 1/2 33078 U1 6 5 7 17K8:1 ...

  • YORKVILLE 3400 - page 14

    VCD .025" .030" .040" .050" .060" SHEAR SHEAR SHEAR SHEAR SHEAR 2.00 2.00 SOLDERSIDE M1012-2.00 1.20 SEPT’89 M1012 M1012 M1012 BLANK SIZE=15.700"X10.000" 5 5 4 4 1 DRILL DETL M1012-2.00 U3 5532 40 40 40 40 40 40 40 40 U1 33078 @U1 40 40 40 40 40 40 40 40 U2 33078 @U1 40 40 40 40 40 40 40 40 R14 4M7 40 40 R15 17K ...

  • YORKVILLE 3400 - page 15

    WC3 MC1 1 40CFM FAN 22n CSA C54 MC1 2 D47 7K5 R123 33v 500mW ZD15 27K R116 8 7 MC1 3 MC1 4 MC1 5 WC8 WC6 WC4 WC7 EY7 EY6 EY3 EY5 EY10 WC11 WC1 1K R124 D48 EY13 EY14 D37 D46 22n CSA C53 4n7 CSA C55 EY4 EY2 EY11 D41 4v7 500mW ZD10 2R2 0.5W R122 D40 MJH11018 Q35 EY8 1N4004 D45 470u 25v C51 1N4004 D44 25v 22n C50 A06 Q33 4v7 500mW ZD11 68K R113 68K R11 ...

  • YORKVILLE 3400 - page 16

    WC3 MC1 1 40CFM FAN 22n CSA C54 MC1 2 D47 7K5 R123 33v 500mW ZD15 27K R116 8 7 MC1 3 MC1 4 MC1 5 WC8 WC6 WC4 WC7 EY7 EY6 EY3 EY5 EY10 WC11 WC1 1K R124 D48 EY13 EY14 D37 D46 22n CSA C53 4n7 CSA C55 EY4 EY2 EY11 D41 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 # DESCRIPTION OF CHANGE VER# DATE MODEL(S):- D D D D D D D D D SEPT/28 ...

  • YORKVILLE 3400 - page 17

    .020" .012" .008" .005" SHEAR SHEAR SHEAR SHEAR SHEAR SHEAR SHEAR SHEAR VCD .020" .012" .008" .005" .020" .012" .008" .005" SOLDERSIDE M1013-2.30 2.30 BLANK SIZE=12.600"X6.500" M1013- 2 OZ COPPER DRILL DETL M1013-2.30 TJH2 L1 #3822 C44 @C1 80V 330U C45 @C1 80V 330U C46 @C1 80V 33 ...

  • YORKVILLE 3400 - page 18

    R27 2R2 GS Q6A @Q1 MTP2P50E D1 4148 D2 4148 D3 4148 J12 R79 1W 0.R47 D9 4148 C22 @C3 #5892 80V 6800U C23 @C3 #5892 80V 6800U C24 @C3 #5892 80V 6800U C25 @C3 #5892 80V 6800U C3 22U 10V TAB7 WC6 WC6 16AWG 5.5"BLK R5 249R R3 2R2 R4 2R2 R7 150R R15 150R R10 4K7 R8 15K R9 249R R19 249R R16 15K R14 39R R13 36K R6 10K0 R1 39R R17 249R R18 10K0 R2 68R ...

  • YORKVILLE 3400 - page 19

    T esting Repaired Circuit Board Now th at you have rebui lt the M1 002 or M1002A circuit board . It is jus t as impo rtant t o properly pow er up the boar d. If the si newave d oesn’ t look r ight ch eck the s ignal a t test point (1 ) on M1 002 t o ensure that the volt age amplif ier on bo ard M1011 or M1011 A is n’t distor ting the si gnal. I ...

  • YORKVILLE 3400 - page 20

    YORKV ILLE SOUND AP3000 AND AP3400 SERVICE Quick Fix for M1002 and M1002A To speed up the servicing of the AP3000 or AP3400 on your bench, Yorkville Sound’s service department has d eveloped a method to replace the components most likely to fail when a M1002/A amplifier board requir es service. This Quick Fix kit contains the procedure, assembly ...

  • YORKVILLE 3400 - page 21

    STEP 1. Locate the assem bly drawing for the vers ion num ber pr inted o n the M1002 or M1002A circui t board to be se rviced. 2. Rem ove all of t he transi stor s coloure d RED on t he assem b ly draw ing. 3. Measure a nd rem ove any of the di odes col oured BLU E on the assem bly drawin g tha t m ay be d am aged. Rep lace a 1N 4732A 1W 4V7 ze ner ...

  • YORKVILLE 3400 - page 22

    5. Measure the resistor coloured GREEN. Th e measured value should measure within + or – 5% valu e listed in the t able below. Replace any resi stor t hat measure d bey ond th e + or – 5% value list ed in the ta ble bel ow . Resistor P rinted Correct Number Value Measured Value -5% +5% R10 4K7 2K25 2K3 2K35 6. Measure across the pair of test po ...

  • YORKVILLE 3400 - page 23

    SHEAR SHEAR SHEAR SHEAR VCD SHEAR SHEAR SHEAR SHEAR SOLDERSIDE M1002-9.00 BLANK SIZE=14.750"X8.850" S GG S G S D G S D G G S R27 2R2 GS Q6A @Q1 MTP2P50E D1 4148 D2 4148 D3 4148 J12 R79 1W 0.R47 D9 4148 C22 @C3 #5892 80V 6800U C23 @C3 #5892 80V 6800U C24 @C3 #5892 80V 6800U C25 @C3 #5892 80V 6800U C3 22U 10V TAB7 WC6 WC6 16AWG 5.5"BLK ...

  • YORKVILLE 3400 - page 24

    BL U RED BL U GR E Y Y ELLOW WH I TE YEL WHT RED FAN- BL K T-BRK BL K RED Y ELLOW BLU AC- W HI TE FAN- L1 WC 7 C44 C45 C46 C47 EY7 EY10 EY11 EY5 EY 1 2 WC8 TJ H 1 WC10 WC 4 WC3 EY13 WC 1 WC11 WC6 EY8 EY6 EY9 RV5 100K EY2 EY3 EY4 C55 4N7 250V EY14 C53 22N 250V C54 22N 250V RV6 100K #1 289 AP-3400C E XFM R WIRING NOV 13. 95 SHOW N WI RED FO R 23 0V ...

  • YORKVILLE 3400 - page 25

    BL U RED BL U GR E Y Y ELLOW WH I TE YEL WHT RED FAN- BL K T-BRK BL K RED Y ELLOW BLU AC- W HI TE FAN- L1 WC 7 C44 C45 C46 C47 EY7 EY10 EY11 EY5 EY 1 2 WC8 TJ H 1 WC10 WC 4 WC3 EY13 WC 1 WC11 WC6 EY8 EY6 EY9 RV5 100K EY2 EY3 EY4 C55 4N7 250V EY14 C53 22N 250V C54 22N 250V RV6 100K #1 289 AP-3400C E XFM R WIRING NOV 13. 95 SHOW N WI RED FO R 24 5V ...

Produzent YORKVILLE Kategorie Stereo Amplifier

Dokumente, die wir vom Produzenten des Geräts YORKVILLE 3400 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen YORKVILLE
- Bedienungsanleitungen 3400
- Produktkarten YORKVILLE
- Informationsbroschüren
- oder Energieetiketten YORKVILLE 3400
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung YORKVILLE 3400.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen YORKVILLE 3400, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen YORKVILLE 3400. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts YORKVILLE 3400 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts YORKVILLE 3400, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von YORKVILLE 3400 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von YORKVILLE 3400 verständlich ist.

Eine gänzliche Bedienungsanleitung von YORKVILLE sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von YORKVILLE 3400 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von YORKVILLE 3400 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich YORKVILLE 3400, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts YORKVILLE 3400 - die uns die ersten Schritte während der Nutzung von YORKVILLE 3400 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit YORKVILLE 3400 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von YORKVILLE 3400 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich YORKVILLE 3400?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit YORKVILLE 3400 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit YORKVILLE 3400 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)