Bedienungsanleitung Enterasys Networks 4H4203-72

90 Seiten 2.43 mb
Download

Zur Seite of 90

Summary
  • Enterasys Networks 4H4203-72 - page 1

    7.5x9-inch cover with bleed on 4 sides Enterasys Matrix ® DFE-Gold Series Hardware Installation Guide Module 4H4282-49 Module 4H4283-49 Module 4H4203-72 Module 4H4202-72 Module 4H4284-49 P/N 9033906-05 ...

  • Enterasys Networks 4H4203-72 - page 2

    ...

  • Enterasys Networks 4H4203-72 - page 3

    i Notice Enterasys Networks  reserv es  the  right  to  make  changes  in  specif ications  and  other  info rmation  contained  in  this  document  and  its  web  site  without  prior  notice.  The  reader  should  in  all  cases  consult  Enterasy s Networks ...

  • Enterasys Networks 4H4203-72 - page 4

    ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This  device  com plies  with  Par t  15  of  th e  FCC  rules.  Operat ion  is  subject  to  the  foll owing  tw o  conditions:  (1)  this  device  may  not  cause  harmful  interference, ? ...

  • Enterasys Networks 4H4203-72 - page 5

    iii Electromagnetic Compatibility (EMC) This  product  complies  with  the  follo wing:  47  CFR  Par t s  2  and  15,  CSA  C108.8,  2004/108/EC,  EN  55022,  EN  61000 ‐ 3 ‐ 2,  EN 61000 ‐ 3 ‐ 3,  EN  55024,  AS/NZS  CISPR  22,  VCCI  V ‐ 3.  Compatibilidad ...

  • Enterasys Networks 4H4203-72 - page 6

    iv Enterasys  Customer  Support  at  353  61  705586  (Ireland). ѻ ѻ ક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼៪ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 &U   ໮⒈㘨㣃 3%% ໮⒈Ѡ㣃䝮  ...

  • Enterasys Networks 4H4203-72 - page 7

    v VCCI Notice This  is  a  class  A  product  based  on  the  standard  of  the  Vo l u n t a r y  Control  Co uncil  for  Interfe rence  by  Information  Te c h n o l o g y  Equipment  (VCCI).  If  this  equipmen t  is  used  in  a  domestic  environment,  ...

  • Enterasys Networks 4H4203-72 - page 8

    vi Safety Information Class 1 Laser Transceivers The single mode interface modules use Class 1 laser transceivers . Read the following safe ty information before installing or operating these m odules. The  Class  1  laser  transceivers  use  an  optical  feedback  loop  to  maintain  Class  1  operation ? ...

  • Enterasys Networks 4H4203-72 - page 9

    vii ENTERASYS NETWORKS, INC. FIRMWARE LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This  document  is  an  agreement  (“ Agreement”)  betwee n  the  end  user  (“Y o u”)  and  Enteras ys  Networks,  In c.,  on  behalf  of  its ...

  • Enterasys Networks 4H4203-72 - page 10

    viii 3. APPLICABLE  LAW. This  Agreem ent  shall  be  interpreted  and  governed  under  the  laws  and  in  the  state  and  federal  courts  of  th e  Commonwealth  of  Massachu setts  with out  regard  to  its  conflicts  of  laws  provis ions.  You  ...

  • Enterasys Networks 4H4203-72 - page 11

    ix 8. AUDIT  RIGHTS. You  here by  acknowled ge  that  the  intellectual  property  rights  associated  with  the  Program  are  of  critical  value  to  Enterasys,  and,  accordingly,  You  hereby  agree  to  maintain  complete  books,  re cords  and  account ...

  • Enterasys Networks 4H4203-72 - page 12

    x ...

  • Enterasys Networks 4H4203-72 - page 13

    xi Contents About This Guide Who Should Use This G uide .............. ....................... ....................... ......................... ................ .......... xv How to Use This Guide ................ ....................... ...................... ....................... ..................... ........ ..... xvi Related Documents ..... ...

  • Enterasys Networks 4H4203-72 - page 14

    xii Connecting to COM Port for Local Management ................... ....................... ...................... ............. 3-20 What Is Needed ..... ...................... .................... ...................... ....................... .................... ...... ... 3-20 Connecting to an IBM PC or Co mpatible Device .......... .......... ...

  • Enterasys Networks 4H4203-72 - page 15

    xiii Figures 1-1 4H4282-49, 4H4283-49, and 4H4203-72 DFE-Gold Modules .................... ...................... ............ 1-4 1-2 4H4202 -72 and 4H4284-49 DFE-Gold Modules . ....................... ...................... ....................... ..... 1-5 3-1 Examples, Slot Numbers/Module Placement in Ma trix E7 Chassis .................... ... ...

  • Enterasys Networks 4H4203-72 - page 16

    xiv Tables 3-1 Contents of DFE-Gold Module Carton .............. ...... .................... ...................... ....................... ..... 3-2 4-1 LANVIEW LEDs ......... ....................... ...................... ....................... ...................... ............. ............ 4-5 4-1 Troubleshooting Checklist ... ... .......... ...

  • Enterasys Networks 4H4203-72 - page 17

    Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide xv About This Guide This  guide  provides  an  ov erview ,  installation  and  troubleshooting  instructions,  and  specifications  for  the  Enterasys  Matr ix ®  DFE ‐ Gold  4H42 82 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72, ...

  • Enterasys Networks 4H4203-72 - page 18

    How to Use This Guide xvi About This Guide How to Use This Guide This  preface  provides  an  overview  of  this  guide  and  the  DFE ‐ Gold  Series  manual  set,  and  a  brief  summary  of  each  chapter;  de fines  the  conv entions  used  in  this  document;  ...

  • Enterasys Networks 4H4203-72 - page 19

    Conventions Used in This Guide Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide xvii Conventions Used in This Guide The  following  conventions  are  used  in  this  guide: Lowercase  x :  Indicates  the  general  use  of  an  alphanumeric  character  (for  example,  6x1xx ...

  • Enterasys Networks 4H4203-72 - page 20

    Getting Help xviii About This Guide Getting Help For  additional  support  related  to  the  modules  or  this  document,  contact  Enterasys Networks  using  one  of  the  following  metho ds: Before  contacting  Enterasys Networks  for  technical  support,  have  the  foll ...

  • Enterasys Networks 4H4203-72 - page 21

    Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-1 1 Introduction This  chapter  provides  an  overview  of  the  DFE ‐ Gold  module  capabilities,  and  introduces  the  4H4282 ‐ 49,  4H428 3 ‐ 49,  4H4203 ‐ 72,  4H 4202 ‐ 72,  and  4H4284 ‐ 49  DFE ‐ Gold ...

  • Enterasys Networks 4H4203-72 - page 22

    The DFE-Gold Modules 1-2 Introduction • Support  for  a  var i et y  of  converged  applications  including  Vo I P  with  Po we r ‐ over ‐ Ethernet  The DFE-Gold Modules This  section  provides  an  overview  of  the  4H4282 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72  ( Figure 1 ‐ ...

  • Enterasys Networks 4H4203-72 - page 23

    The DFE-Gold Modules Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-3 full ‐ duplex  mode  of  operation.  The  duplex  mode  can  be  determined  by  either  auto ‐ negotiation  or  manual  configuration.  4H4202-72 The  4H4202 ‐ 72  has  72,  10BASE ‐ T/10 ...

  • Enterasys Networks 4H4203-72 - page 24

    The DFE-Gold Modules 1-4 Introduction Figure 1- 1 4H4282-49, 4H4283-49, and 4H4203- 72 DFE-Gold Modules 1 OFFLINE/RESET button 6 GROUP status LEDs 2 RJ45 COM (Console Port) 7 GROUP select LEDs 3 CPU LED 8 4H4282-49 / 4H4283-49 - N EM option slot 4 MGMT LED 4H4203-72 - Ports (1-72), 10/100, through six RJ21s 5 GROUP SELECT button 9 4H4282-49 - Ports ...

  • Enterasys Networks 4H4203-72 - page 25

    The DFE-Gold Modules Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-5 Figure 1-2 4H4202-72 and 4H4284-49 DF E-Gold Modul es 1 OFFLINE/RESET switch 6 GROUP select LEDs 2 RJ45 COM (Console Port) 7 GROUP SELECT button 3 CPU LED 8 GROUP status LEDs 4 MGMT LED 9 4H4202-72 - Groups 1&2, 48 Ports, 10/100, through RJ45s 4H4284-4 ...

  • Enterasys Networks 4H4203-72 - page 26

    Connectivity 1-6 Introduction Connectivity 4H4282-49 Depending  on  how  the  4H4282 ‐ 49  ( Figure 1 ‐ 1 )  is  configured,  it  can  support  up  to: • 48,  10BASE ‐ T/100BASE ‐ TX  swi tched  ports  connected  through  48  fixed,  RJ45  front ‐ panel  connectors,  o ...

  • Enterasys Networks 4H4203-72 - page 27

    Management Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-7 Management Management  of  the  module  can  be  either  in ‐ band  or  out ‐ of ‐ band.  In ‐ band  remote  management  is  possible  us ing  Te l n e t ,  Enterasys Networks’  NetSight ®  man agem ...

  • Enterasys Networks 4H4203-72 - page 28

    LANVIEW Diagnostic LEDs 1-8 Introduction •N e t w o r k  Services  are  logical  groups  of  Classification  Rules  that  identify  specific  networked  applic ations  or  services .  Users  may  be  permitted  or  denied  access  to  these  services  based  on  thei ...

  • Enterasys Networks 4H4203-72 - page 29

    Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 2-1 2 Network Requirements Before  inst alling  the  module,  review  the  requirements  and  specificat ions  referred  to  in  this  chapter  concerning  the  following: • 10BASE ‐ T  Netw ork  (page 2 ‐ 1) • 100BASE ...

  • Enterasys Networks 4H4203-72 - page 30

    100BASE-TX Network 2-2 Network Requirements 100BASE-TX Network Fixed  front  panel  ports  of  the  4H4282 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72,  and  4H4202 ‐ 72 provide  a  connection  that  supports  Category  5  UTP  cabling.  The  device  at  the  other  end  of  ...

  • Enterasys Networks 4H4203-72 - page 31

    Matrix DFE-Gold Series Modules Hardware Installation Guide 3-1 3 Installation This  chapter  provides  the  instructions  to  install  the  4H4282 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72,  4H4202 ‐ 72,  and  4H4284 ‐ 49 DFE ‐ Gold modules. Follow  the  order  of  the  sections  li sted ? ...

  • Enterasys Networks 4H4203-72 - page 32

    Installation Site Requirement 3-2 Installation Inst allation Site Requirement The  DFE ‐ Gold module  must  be  installed  in  a  Matrix  E7,  N1,  N3,  N5,  or  N7  chassis  located  in  a  Restricted  Access  Location  (RAL).  This  location  should  only  be  acce ...

  • Enterasys Networks 4H4203-72 - page 33

    Installing Optional Netw ork Expansion Module Matrix DFE-Gold Series Modules Hardware Installation Guide 3-3 Inst alling Optional Network Exp ansion Module A  Phillips  screwdriver  is  required  to  ins tall  an  optional  netw ork  expansion  module  into  the  4H4282 ‐ 49,  4H428 3 ‐ 49,  or ? ...

  • Enterasys Networks 4H4203-72 - page 34

    DFE Module Placement and Installation Rules 3-4 Installation To  ensure  proper  operation  of  the  system,  consider  the  following  examples  and  rules  for  module  placement  in  either  chassis. Example 1 ( Figure 3-1 , A) Shows  one  module  installed  in  the  chassis ...

  • Enterasys Networks 4H4203-72 - page 35

    Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installation Guide 3-5 Example 3 ( Figure 3-1 , C) Shows  the  primary  management  module  missing  from  slot  1.  As  long  as  the  module  installed  in  slot  2  is  designated  as  a  re dundant  manag ...

  • Enterasys Networks 4H4203-72 - page 36

    Installing Module into a Chassis 3-6 Installation Prep aration 1. Remove  the  blank  pan el  cov ering  the  slot  in  which  the  module  will  be  installed.  All  other  slots  must  remain  cov ered  to  ensure  proper  airflow  for  cooling.  (Save  the  blank ...

  • Enterasys Networks 4H4203-72 - page 37

    Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installation Guide 3-7 2. Align  the  module  card  between  the  upper  and  lower  card  guides  of  the  desired  slot  and  slide  it  into  the  chassis,  taking  care  that  the  module  slides ...

  • Enterasys Networks 4H4203-72 - page 38

    Installing Module into a Chassis 3-8 Installation Figure 3-2 Inst alling Module into Matr ix E7 or N7 Chassis (Matrix E7 shown) 1 Card guides 5 Upper/lower locking tabs (in proper open position) 2 Slot number 1(right-most slot is 7) 6 Upper/lower locking tab (in clo sed position) 3 Module card 7 Backplane connectors (power and FTM2) 4 Metal back p ...

  • Enterasys Networks 4H4203-72 - page 39

    Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installation Guide 3-9 Inst alling Module into Matr ix N1, N3, or N5 Chassis A  DFE ‐ Gold module  can  be  installed  in  any  av ailable  chassis  sl ot  (1  through  3)  in  the  Matrix N3  chassis  or  slots  1  ...

  • Enterasys Networks 4H4203-72 - page 40

    Connecting to the Network 3-10 Installation Connecting to the Network For  connecting  unshielded  twisted  pair  (UTP )  segments  from  the  network  or  other  devices,  refer  to • Connecting  UTP  Cables  to  4H4282 ‐ 49  or  4H4202 ‐ 72  (page 3 ‐ 11) • Connecting  UT ...

  • Enterasys Networks 4H4203-72 - page 41

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-11 Connecting UTP Cables to 4H4282-49 or 4H4202-72 The  fixed  RJ4 5  front  panel  connections  of  the  4H4282 ‐ 49  and  4H4202 ‐ 72  are  10/100  Mbps  ports.  The  ports  have  internal  crossov er ...

  • Enterasys Networks 4H4203-72 - page 42

    Connecting to the Network 3-12 Installation 3. V erify  that  a  link  ex ists  by  check ing  that  the  port  RX  (Receive )  LED  is  ON  (flashi ng  amber ,  blinking  green,  or  solid  green).  If  the  RX  LED  is  OFF  and  the  TX  (T ransmit)  ...

  • Enterasys Networks 4H4203-72 - page 43

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-13 Figure 3-5 Four-Wire Crossover Cable RJ45 Pinout s, Connections Between Hub Devices 1 RJ45 device port 3 RJ45-to-RJ45 crossover cable 2 Other device port 4 RX+/RX- and TX+/TX- connections. These connections must share a common color pair . Figure 3-6 Four-Wire ...

  • Enterasys Networks 4H4203-72 - page 44

    Connecting to the Network 3-14 Installation Figure 3-7 Eight-Wire Crossover Cable RJ45 Pin outs , Connections Between Hub Devices 1 RJ45 device port 3 RJ45-to-RJ45 crossover cable 2 Other device port Figure 3-8 Eight-Wire Straight -Throu gh Cable RJ45 Pinout s, Connections Between Sw itches and End-Use r Devices 1 RJ45 device port 3 RJ45-to-RJ45 st ...

  • Enterasys Networks 4H4203-72 - page 45

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-15 e. Ensure  that  the  twisted  pai r  connection  meets  the  dB  loss  and  cable  specifications  outlined  in  the  Cabling  Guide.  Refer  to   “Related  Documents”  on  page xvi ? ...

  • Enterasys Networks 4H4203-72 - page 46

    Connecting to the Network 3-16 Installation 3. T o  install  an  RJ21  right ‐ angle  connector ,  refer  to  Fi gure 3 ‐ 10  and  proceed  as  follows: a. If  using  an  optional  RJ21  angle  adapter  available  from  Enterasys  Networks,  insert  the  angle  adapte ...

  • Enterasys Networks 4H4203-72 - page 47

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-17 Figure 3-10 Connection Using Optional RJ21 Angle Adapter 1 RJ21 angle adapter 5 Retaining clips 2 RJ21 port connector 6 GROUP SELECT button 3 Retaining screws 7 Example showing how multiple cables would be arranged along the front panel. 4 RJ21 right-angled co ...

  • Enterasys Networks 4H4203-72 - page 48

    Connecting to the Network 3-18 Installation 4. V erify  that  a  link  ex ists  by  check ing  that  the  port  RX  (Receive )  LED  is  ON  (flashi ng  amber ,  blinking  green,  or  solid  green).  If  the  RX  LED  is  OFF  and  the  TX  (T ransmit)  ...

  • Enterasys Networks 4H4203-72 - page 49

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-19 2. Insert  the  MT ‐ RJ  cable  connector  into  the  MT ‐ RJ  front  panel  connector  until  it  clicks  into  place. Figure 3-1 1 Connecting a Fiber-Optic Segment to MT -RJ Front Panel Connector Note: Leave t ...

  • Enterasys Networks 4H4203-72 - page 50

    Connecting to COM Port for Local Management 3-20 Installation 1. V erify  that  a  link  ex ists  by  check ing  that  the  port  RX  LED  is  ON  (flashing  amber ,  blinking  green,  or  solid  green).  If  the  RX  LED  is  OFF  and  the  TX  LED  is  ...

  • Enterasys Networks 4H4203-72 - page 51

    Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-21 Wi th  a  UTP  straight ‐ through  cab le  and  RJ45 ‐ to ‐ DB25  female  ad apter ,  yo u  can  connect  products  equipped  with  an  RJ45  COM  port  to  a  VT  se rie ...

  • Enterasys Networks 4H4203-72 - page 52

    Connecting to COM Port for Local Management 3-22 Installation Connecting to a VT Series T erminal To  connect  a  VT  Series  terminal  to  an  Enterasys Netw orks  DFE ‐ Gold module  COM  port  ( Figure 3 ‐ 13 ),  use  a  UTP  straight ‐ through  cable  with  RJ45  connectors  an ...

  • Enterasys Networks 4H4203-72 - page 53

    Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-23 When  these  parameters  are  set,  the  Local  Management  password  screen  will  display .  Refer  to  the  Enterasys  Matrix  DFE ‐ Gold  Series  Configuration  Guide  for ? ...

  • Enterasys Networks 4H4203-72 - page 54

    Connecting to COM Port for Local Management 3-24 Installation 5. With  a  PC  connected  to  a  remote  mo dem,  you  can  configure  th e  switch  remotely .  To  accomplish  this,  you  must  configure  you r  PC  VT  emulation  package  with  the  following  para ...

  • Enterasys Networks 4H4203-72 - page 55

    Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-25 Adapter Wiring and Signal Assignment s COM Port Adapter Wiring and Sign al Diagram RJ45 DB9 Pin Conductor Pin Signal 1 Blue 2 Receive (RX) 4 Red 3 T ransmit (TX) 5 Green 5 Ground (GRD) 2 Orange 7 R equest to Send (RTS) 6 Y ellow 8 Clear to Se ...

  • Enterasys Networks 4H4203-72 - page 56

    Completing the Installation 3-26 Installation Completing the Inst allation Completing  the  DFE  module  installat ion  depends  on  if  the  module  is  being  installed  in: •a  new  DFE  module  syst em  (refer  to  “Completing  the  Installation”  on  page 3 ‐ 26), ...

  • Enterasys Networks 4H4203-72 - page 57

    Completing the Installation Matrix DFE-Gold Series Modules Hardware Installation Guide 3-27 First-T ime Log-In Using a Console Port Connection Start  the  Command  Line  Interface  (CLI)  from  the  module’ s  local  console  port  as  follo ws: 1. Connect  a  terminal  to  the  local  cons ...

  • Enterasys Networks 4H4203-72 - page 58

    Completing the Installation 3-28 Installation Completing the Inst allation of a DFE-Gold Module in an Existing System In  an  established  DFE ‐ Gold module  system, •a  DFE ‐ Gold module  is  already  established  as  the  management  module, •t h e  passwords  hav e  alrea dy  been  set ? ...

  • Enterasys Networks 4H4203-72 - page 59

    Completing the Installation Matrix DFE-Gold Series Modules Hardware Installation Guide 3-29 Logging in with an Administrati vely-Configured User Account If  the  device’ s  default  user  account  settings  have  been  changed,  proceed  as  follows: 1. At  the  login  prompt,  enter  your  ad ...

  • Enterasys Networks 4H4203-72 - page 60

    Completing the Installation 3-30 Installation ...

  • Enterasys Networks 4H4203-72 - page 61

    Matrix DFE-Gold Series Modules Hardware Installation Guide 4-1 4 T roubleshooting This  chapter  provides  information  concerning  the  following: • Using  LANVIEW  (page 4 ‐ 1) • T roubleshooting  Checklist  (page 4 ‐ 7) • Overview  of  DF E ‐ Gold  Module  Shutdown  Procedure  (page 4 ? ...

  • Enterasys Networks 4H4203-72 - page 62

    Using LANVIEW 4-2 Troubleshooting Viewing Receive/T ransmit Activi ty on 4H4282-49, 4H4283-49, and 4H4203-72 On  the  4H4282 ‐ 49,  4H4283 ‐ 49,  and  4H4203 ‐ 72  you  can  view  the  receive  and  transmit  activity  on  the  RX  and  TX  LEDs.  How ever ,  only  one  grou ...

  • Enterasys Networks 4H4203-72 - page 63

    Using LANVIEW Matrix DFE-Gold Series Modules Hardware Installation Guide 4-3 Viewing Receive/T ransmit Activity on 4H4202-72 On  the  4H4202 ‐ 72,  you  can  view  the  receive  and  transmit  activity  on  the  RX  and  TX  LEDs.  Howeve r ,  only  one  group  of  24  ports  ...

  • Enterasys Networks 4H4203-72 - page 64

    Using LANVIEW 4-4 Troubleshooting Viewing the Receive and T ran smit Activity on 4H4284-49 On  the  4H4284 ‐ 49  DFE ‐ Gold module,  you  can  view  the  receive  and  transmit  activity  on  the  RX  and  TX  LEDs.  How ever ,  only  one  group  of  12  ports  may  b ...

  • Enterasys Networks 4H4203-72 - page 65

    Using LANVIEW Matrix DFE-Gold Series Modules Hardware Installation Guide 4-5 T able 4-1 LANVIEW LEDs LED Color Stat e Recomme nded Action MGMT None Off . This module is NOT the Management Module. None. Green Solid . This module is the designated Management Module. None. Amber Flashing . This is a temporary indi cation that the module is saving data ...

  • Enterasys Networks 4H4203-72 - page 66

    Using LANVIEW 4-6 Troubleshooting RX (Receive) None No link . No activity . Port enabled or di sabled. None. Green Solid . Link present, port enabled, no traffic is being received by the i nterface. None. Amber Flashing . Link present, port enabled, traffic is being received by the i nterface. Rate of flashing indicate s the data transmission rate. ...

  • Enterasys Networks 4H4203-72 - page 67

    Troubleshooting Checklist Matrix DFE-Gold Series Modules Hardware Installation Guide 4-7 T roubleshooting Checklist If  the  module  is  not  work in g  properly ,  refer  to  Ta b l e 4 ‐ 1  for  a  checklist  of  problems,  possible  causes,  and  recommended  actions  to  resolve ? ...

  • Enterasys Networks 4H4203-72 - page 68

    Troubleshooting Checklist 4-8 Troubleshooting Port(s) goes into standby for no apparent reason. Loop conditio n detected. V erify th at S panning T ree is enabled. Refer to the Enterasys Matrix DFE-Gold Series Confi guration Guide for the instructions to set the type of ST A. Review the network design and dele te unnecessary loops. If the problem c ...

  • Enterasys Networks 4H4203-72 - page 69

    Overview of DFE-Gold Module Shutdown Procedure Matrix DFE-Gold Series Modules Hardware Installation Guide 4-9 Overview of DFE-Gold Module Shut down Procedure The  DFE ‐ Gold module s  installed  in  a  Mat rix  N3  or  Matrix  N7  chassis  are  inter dependent  and  operate  under  a  single  ...

  • Enterasys Networks 4H4203-72 - page 70

    Overview of DFE-Gold Module Shutdown Procedure 4-10 Troubleshooting Recommended Shut down Procedure Using OFFLINE/RESET Switch Before  pulling  a  DFE ‐ Gold module  out  of  a  chas sis,  press  or  tap  on  its  OFFLINE/RESET  switch  for  less  than  1 second.  Its  CPU  LED  ch ...

  • Enterasys Networks 4H4203-72 - page 71

    Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-1 A Specifications This  appendix  provides  information  about  the  foll owing: • DFE ‐ Gold  Module  Specifications  (page A ‐ 1) • COM  Po r t  Pinout  Assignments  (page A ‐ 3) • Regulatory  Compliance  (page A ‐ 4) ...

  • Enterasys Networks 4H4203-72 - page 72

    DFE-Gold Module Specifications A-2 Specifications 4H4203-72 Ports 1 through 72 Seventy- two, 10BASE-T/100BASE-TX compliant ports through six RJ21 connectors. 4H4202-72 Ports 1 through 72 Seventy- two, 10BASE-T/100BASE-TX compliant ports through 72 RJ45 connectors. 4H4284-49 Ports 1 through 48 Forty-eigh t, 100BASE-FX multimode fi ber-optic complian ...

  • Enterasys Networks 4H4203-72 - page 73

    COM Port Pinout Assignments Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-3 COM Port Pinout Assignment s The  COM  port  is  a  serial  communications  port  for  loc al  access  to  Local  Management.  Refer  to  Ta b l e A ‐ 2  for  the  COM  port  pin  a ...

  • Enterasys Networks 4H4203-72 - page 74

    Regulatory Compliance A-4 Specifications Regulatory Compliance The  4H4282 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72,  4H4202 ‐ 72,  4H4284 ‐ 49,  and  7G ‐ 6MGBIC  mee t  the  safety  and  electromagnetic  compatibility  (EM C)  requirements  listed  in  Ta b l e A ‐ 3 : T able A-3 Complia ...

  • Enterasys Networks 4H4203-72 - page 75

    Matrix DFE-Gold Series Modules Hardware Installation Guide B-1 B Mode Switch Bank Settings and Optional Installations This  appendix  covers  the  following  items: • Required  T ools  (page B ‐ 1) • Setting  the  Mode  Switches  (page B ‐ 2) • Memory  Locations  and  Replacement  Procedure s ? ...

  • Enterasys Networks 4H4203-72 - page 76

    Setting the Mode Switches B-2 Mode Switch Bank Settings and Optional Installations Setting the Mode Switches Figure B ‐ 1  and  Figure B ‐ 2  show  the  location  of  the  mode  switches  and  the  switch  settings  for  normal  operation.  These  switches  are  set  at  the  ...

  • Enterasys Networks 4H4203-72 - page 77

    Setting the Mode Switches Matrix DFE-Gold Series Modules Hardware Installation Guide B-3 Figure B-1 Mode Switch Location on 4H4282-49 and 4H42 83-49 1 Mode switch bank (located in same location on both the 4H4282-49 and 4H4 283-49) Figure B-2 Mode Switch Location on 4H4203-72 1 Mode switch bank 4H4282-49 F AST ENET DFE 1 2 3 4 5 6 ➀ ON 12 34 5 67 ...

  • Enterasys Networks 4H4203-72 - page 78

    Setting the Mode Switches B-4 Mode Switch Bank Settings and Optional Installations Figure B-3 Mode Switch Location on 4H4202-72 1 Mode switch bank Figure B-4 Mode Switch Location on 4H4284-49 1 Mode switch bank ➀ 1 2345678 ON COM OFFLINE / RESET CPU MGMT GROUP GROUP SELECT GROUP 1 GROUP 2 GROUP 3 1X 6X 7X 12X 13X 18X 19X 24X 1 2 3 4H4202-72 F AST ...

  • Enterasys Networks 4H4203-72 - page 79

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-5 Memory Locations and Replacement Procedures In  the  event  that  the  Dual  In ‐ line  Memory  Module  (DIMM)  or  DRAM  Single  In ‐ li ne  Memory  Module  (SIMM)  (FLASH  memory)  ...

  • Enterasys Networks 4H4203-72 - page 80

    Memory Locations and Replacement Procedures B-6 Mode Switch Bank Settings and Optional Installations Figure B-6 DIMM and DRAM SIMM Locations (4H4203-72) 1 DRAM SIMM 2 DIMM 3 Main PC board Figure B-7 DIMM and DRAM SIMM Locations (4H4202-72) 1 DRAM SIMM 2 DIMM 3 Main PC board  À Á G R O U P 1 G R O U P 2 G R O U P 3 G R O U P 4 7 2X 7 2X 6 1X 6 1 ...

  • Enterasys Networks 4H4203-72 - page 81

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-7 DIMM Replacement Procedure (4H4282-49 and 4H4283-49) To  remov e  and  replace  the  DRAM  SIMM  on  the  4H4282 ‐ 49  or  4H4283 ‐ 49,  ref er  to  Figure B ‐ 8  and  Figure B ‐ 9  re ...

  • Enterasys Networks 4H4203-72 - page 82

    Memory Locations and Replacement Procedures B-8 Mode Switch Bank Settings and Optional Installations 2. Refer  to  Figure B ‐ 9 .  Push  the  connector  arms  aw ay  from  the  memor y  module  to  release  it  from  the  connector .  3. Remove  the  module  from  the  connector ...

  • Enterasys Networks 4H4203-72 - page 83

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-9 Removing the DRAM SIMM from 4H4203-72 To  remov e  the  existing  DRAM  SIMM,  proceed  as  follows: 1. Locate  the  DRAM  SIMM  connector  on  the  main  PC  board.  Refer  back  to ...

  • Enterasys Networks 4H4203-72 - page 84

    Memory Locations and Replacement Procedures B-10 Mode Switch Bank Settings and Optional Installations 3. Pull  the  DRAM  SIMM  straight  up  and  remove  it  from  the  connector . Installing the DRA M SIMM on 4H4203-72 To  install  the  DRAM  SIMM,  refer  to  Figure B ‐ 12  and  proce ...

  • Enterasys Networks 4H4203-72 - page 85

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-11 DRAM SIMM Replacement (4H4202-72) Figure B-12 Installing the DRAM SIMM on 4H42 03-72 1 Connector arms 3 Connector fingers 2 DRAM SIMM 4 Alignment notches (2) À Ã Á Ã À Â Note: Because of the complexity of correctly replacing the large d ...

  • Enterasys Networks 4H4203-72 - page 86

    Memory Locations and Replacement Procedures B-12 Mode Switch Bank Settings and Optional Installations DIMM Replacement Proc edure (All DFE Modules) In  the  event  that  the  DIMM  need s  to  be  replaced,  the  following  sec tions  explain  how  to  remove  and  install  the  DIMM.  ...

  • Enterasys Networks 4H4203-72 - page 87

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-13 Inst alling the DIMM To  install  a  DIMM,  refer  to  Figure B ‐ 14  and  proceed  as  follows: 1. Insert  the  DIMM  down  between  the  connector  fingers . 2. Pivot  the  DIMM  ...

  • Enterasys Networks 4H4203-72 - page 88

    Memory Locations and Replacement Procedures B-14 Mode Switch Bank Settings and Optional Installations ...

  • Enterasys Networks 4H4203-72 - page 89

    Index-1 Index Numerics 100BASE-FX connections 3-18 requirements 2-2 100BASE-TX connections 3-1 1 requirements 2-2 10BASE-T connections 3-1 1 , 3-15 requirements 2-1 4H4202-72 introduction to 1-3 4H4203-72 introduction to 1-3 4H4282-49 introduction to 1-2 4H4283-49 introduction to 1-2 4H4284-49 introduction to 1-3 C Cable connections 4H4282-49 or 4 ...

  • Enterasys Networks 4H4203-72 - page 90

    Index-2 Matrix N3 chassis module installation into 3-9 Matrix N5 chassis module installation into 3-9 Memory replacement of DRAM B-12 Memory locations DIMM and SIMM B-5 Mode Switch setting of B-2 Module features 1-2 , 1-3 N NEM 3-3 Network connecting to 3-10 Network expansion module 3-3 Network Requirements list of 2-1 O OFFLINE/RESET button 4-10 O ...

Produzent Enterasys Networks Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts Enterasys Networks 4H4203-72 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Enterasys Networks
- Bedienungsanleitungen 4H4203-72
- Produktkarten Enterasys Networks
- Informationsbroschüren
- oder Energieetiketten Enterasys Networks 4H4203-72
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Enterasys Networks 4H4203-72.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Enterasys Networks 4H4203-72, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Enterasys Networks 4H4203-72. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Enterasys Networks 4H4203-72 ansehen.

Die komplette Bedienungsanleitung des Geräts Enterasys Networks 4H4203-72, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Enterasys Networks 4H4203-72 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Enterasys Networks 4H4203-72 verständlich ist.

Eine gänzliche Bedienungsanleitung von Enterasys Networks sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Enterasys Networks 4H4203-72 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Enterasys Networks 4H4203-72 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Enterasys Networks 4H4203-72, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Enterasys Networks 4H4203-72 - die uns die ersten Schritte während der Nutzung von Enterasys Networks 4H4203-72 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Enterasys Networks 4H4203-72 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Enterasys Networks 4H4203-72 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Enterasys Networks 4H4203-72?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Enterasys Networks 4H4203-72 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Enterasys Networks 4H4203-72 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)