  • White Rodgers 1F95-1277 - page 1

    Installation 2 Wiring Connections 2 Thermostat Quick Reference 3 Installer Configuration Menu 4 Operating Your Thermostat 7 Programming 7 Troubleshooting 11 www.white-rodgers.com 90 Series Blue Universal Thermostat with 90 Series Blue Universal Thermostat with 90 Series Blue Universal Thermostat with 90 Series Blue Universal Thermostat with 90 Seri ...

  • White Rodgers 1F95-1277 - page 2

    2 2 "AA" Batteries WIRING CONNECTIONS Refer to equipment manu facturers' instructions for specific system wiring informa tion. After wiring, see CONFIGURA- TION section for proper thermosta t configura tion. F or wiring diag rams, see 37-6808A. Wiring diag rams shown are for typical systems and describe the thermosta t ter minal func ...

  • White Rodgers 1F95-1277 - page 3

    3 T ime of Day Day of Week Room T emperature System Switch Fan Switch Indicates when thermostat is calling for Heat or Cool Battery Level Indicator Indicating the current power level of the 2 “AA” batteries. Full power remaining. Half power remaining. Change The batteries should be replaced at this time. Menu key for entering different modes su ...

  • White Rodgers 1F95-1277 - page 4

    4 CONFIGURATION MENU Non- Display e d Press or Program- Program- Press (Factory to select from mable mable Button Default) listed options Comments 1 1 MS 2 HP 1, HP 2, SS 1 Selects Multi-Stage (MS 2, No Heat Pump), Heat Pump 1 (HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor or 2 speed compressor), or Single Stage. 22 (ELE) GAS GAS setting: fu ...

  • White Rodgers 1F95-1277 - page 5

    5 INSTALLER/CONFIGURATION MENU 11) Select Continuous Backlight – In low lighting condi- tions, display backlight impro v es the display contrast. When C ter minal is connected, selecting dL On will tur n the backlight on continuously . Selecting dL Of f will tur n the backlight on momentarily after any ke y is pressed. When C ter minal is not pow ...

  • White Rodgers 1F95-1277 - page 6

    6 20) Heat Temperature Limit Range – This feature adjusts the highest setpoint temperature for heat. The default setting is 99°F . It can be changed between 62°F and 98°F by pressing the or ke y . The " temperature limit " icon will be display ed to the left of your setpoint temperature when using this feature. The " temperature ...

  • White Rodgers 1F95-1277 - page 7

    7 OPERATING YOUR THERMOSTAT Choose the Fan Setting (Auto or On or Prog) F an Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on. F an On selection r uns the fan continuously for increased air circulation or to allow additional air cleaning. F an Prog will cycle the fan for -10 minutes on and 20 ...

  • White Rodgers 1F95-1277 - page 8

    8 Enter the Heating Program 1) Press the Menu button and then press Set Schedule . Press SY STEM button to select either " Heat " or " Cool " in the system s witc h area indica ting the activ e mode being programmed. Y ou can switch to the other mode b y pressing the system switch at any time . 2) The top of the display will sho ...

  • White Rodgers 1F95-1277 - page 9

    9 PROGRAMMING Energy Saving Factory Pre-Program The 1F95-1277 ther mosta ts are prog rammed with the energy saving settings shown in the table below for all da ys of the week. If this pro g ram suits your needs , simply set the ther mostat cloc k and press the RUN button. The table below shows the factor y set hea ting and cooling sc hedule for all ...

  • White Rodgers 1F95-1277 - page 10

    10 PROGRAMMING Wired Remote Temperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the ther mosta t by a maximum cable length of 100 meters (300 ft). Three ter minals, +, S & - are provided on the terminal bloc k to connect to the White- Rodgers standard wired remote sensor . This sensor will be re ...

  • White Rodgers 1F95-1277 - page 11

    11 TROUBLESHOOTING Reset Operation Note : When thermostat is reset, installer configuration menu settings and programming will reset to factory settings. If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them t ...

  • White Rodgers 1F95-1277 - page 12

    St. Louis, Missouri www.white-rodgers.com www.white-rodgers.com www.white-rodgers.com www.white-rodgers.com www.white-rodgers.com HOMEOWNER HELP LINE: 1-800-284-2925 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. ...

Produzent White Rodgers Kategorie Thermostat

Dokumente, die wir vom Produzenten des Geräts White Rodgers 1F95-1277 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen White Rodgers
- Bedienungsanleitungen 1F95-1277
- Produktkarten White Rodgers
- Informationsbroschüren
- oder Energieetiketten White Rodgers 1F95-1277
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung White Rodgers 1F95-1277.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen White Rodgers 1F95-1277, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen White Rodgers 1F95-1277. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts White Rodgers 1F95-1277 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts White Rodgers 1F95-1277, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von White Rodgers 1F95-1277 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von White Rodgers 1F95-1277 verständlich ist.

Eine gänzliche Bedienungsanleitung von White Rodgers sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von White Rodgers 1F95-1277 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von White Rodgers 1F95-1277 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich White Rodgers 1F95-1277, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts White Rodgers 1F95-1277 - die uns die ersten Schritte während der Nutzung von White Rodgers 1F95-1277 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit White Rodgers 1F95-1277 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von White Rodgers 1F95-1277 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich White Rodgers 1F95-1277?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit White Rodgers 1F95-1277 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit White Rodgers 1F95-1277 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)