    1 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Unvented Gas-Fired Room Heater Please read this manual before installing and using appliance. W ARNING: If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury of loss of life. • Do not store or use gasoline or oth ...

  • Vermont Casting VCPV30 - page 2

    2 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters SAFETY : Accidents are always tragic, especially because so many of them could have been prevented with a little care and judgment. There are some basic good practices we hope you will follow for safe use of your gas fired room heater . IMPORT ANT : Read this user’s manual carefully and co ...

  • Vermont Casting VCPV30 - page 3

    3 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters VCBVMN, VCBVMP , VCPVMN, VCPVMP Specifications Input Rating Regulator Inlet Gas Supply Size Gas (Btu/Hr) V ariable Pressure Pressure of Heater Weight VCBV30MN 15,000 30,000 27” x 24” x 8 ⁵⁄₈ ” 30 lbs. VCBV20MN Natural 10,000 20,000 3.0” w .c. 7.0” w .c. 10.5” w .c. 19 ³⁄ ...

  • Vermont Casting VCPV30 - page 4

    4 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Installation Installation Requirements Fresh Air for Combustion and V entilation W ARNING: This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in ...

  • Vermont Casting VCPV30 - page 5

    5 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale from manufacturer . This appliance is only for use with the type of gas indicated on the rating plate. This ...

  • Vermont Casting VCPV30 - page 6

    6 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 1/16" (1.6mm) RH102 Fig. 4 W all anchor. Connect to Gas Supply Before connecting the appliance, turn off all gas appli- ances. Close the main gas valve at the gas meter or Lp tank. Make certain there is good ventilation where the installation will be made. Installation should comply wit ...

  • Vermont Casting VCPV30 - page 7

    7 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap prevents moisture and contaminants from going into the heater controls. If the sediment trap is not installed or is installed wrong, the heater may not operate properly . T est for gas leaks with a m ...

  • Vermont Casting VCPV30 - page 8

    8 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Operating Instructions FOR YOUR SAFETY - READ THIS SECTION BEFORE LIGHTING W ARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLO- SION MA Y RESUL T CAUSING PROPERTY DAM- AGE, PERSONAL INJUR Y OR LOSS OF LIFE. A. BEFORE LIGHTING smell all around the appliance area for g ...

  • Vermont Casting VCPV30 - page 9

    9 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Pilot and Burner Inspection Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 9, 10 and 1 1. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the h ...

  • Vermont Casting VCPV30 - page 10

    10 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Problem When control knob is pressed in and turned counterclockwise to ignition, there is no spark at ODS pilot. When control knob is pressed in and turned counterclockwise to ignition/pilot position, there is spark but no ignition. ODS pilot lights but flame goes out when control knob is r ...

  • Vermont Casting VCPV30 - page 11

    11 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters T roubleshooting, continued Problem Possible Cause Solution Heater produces a clicking noise just after burner is lit or turned off. Gas odor even when control knob is in OFF position. Gas odor during combustion. Heater shuts off on ODS 1. Metal expanding and contracting. 1. Gas leaks. Refe ...

  • Vermont Casting VCPV30 - page 12

    12 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 11 13 14 15 10a,b 9 7 8a,b 5 2 3 1 4 16 16 17 19a 21 18 20 22 23 24 19b 12a,b 6a,b The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 3769 VCBVMN/MP ...

  • Vermont Casting VCPV30 - page 13

    13 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 14. T ubing ODS Assembly RBT27XX0 RBT21XX0 RBT15XX0 15. T ubing Inlet Assembly RBT26XX0 RBT20XX0 RBT14XX0 16. Leg - Front RBI06XX0 RBI06XX0 RBI06XX0 17. Front Panel RBP69P A0 RBP66P A0 RBW22XA0 18. Burner Assembly RBW13XX0 RBW09XX0 RBW08XX0 19a. Burner Support - Left RBP06XA RBP06XA- RBP06X ...

  • Vermont Casting VCPV30 - page 14

    14 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. VCPVMN/MP Unvented Room Heater Item / Model Number VCPV06MN/MP VCPV10MN/MP VCPV18MN/MP VCPV30MN/MP 1. Cover H ...

  • Vermont Casting VCPV30 - page 15

    15 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters VCPVMN/MP , continued Item / Model Number VCPV06MN/MP VCPV10MN/MP VCPV18MN/MP VCPV30MN/MP 20. T ubing Outlet - C Assembly -- -- RCT54XX0 RCT12XX0 21. T ubing Outlet - CL Assembly -- -- -- RCT13XX0 22. T ubing Outlet - CR Assembly -- -- RCT14XX0 -- 23. Manifold - “C” -- -- RCD02XX0 -- 24 ...

  • Vermont Casting VCPV30 - page 16

    16 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters © V ermont Castings, Majestic Products W arranty Service and Limited W arranty The V ermont Castings Majestic Products Company warrants this product to be free form defects in materi- als and components for two (2) years from the date of first purchase, provided that the product has been p ...

Produzent Vermont Casting Kategorie Fan

Dokumente, die wir vom Produzenten des Geräts Vermont Casting VCPV30 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Vermont Casting
- Bedienungsanleitungen VCPV30
- Produktkarten Vermont Casting
- Informationsbroschüren
- oder Energieetiketten Vermont Casting VCPV30
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Vermont Casting VCPV30.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Vermont Casting VCPV30, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Vermont Casting VCPV30. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Vermont Casting VCPV30 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Vermont Casting VCPV30, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Vermont Casting VCPV30 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Vermont Casting VCPV30 verständlich ist.

Eine gänzliche Bedienungsanleitung von Vermont Casting sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Vermont Casting VCPV30 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Vermont Casting VCPV30 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Vermont Casting VCPV30, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Vermont Casting VCPV30 - die uns die ersten Schritte während der Nutzung von Vermont Casting VCPV30 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Vermont Casting VCPV30 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Vermont Casting VCPV30 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Vermont Casting VCPV30?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Vermont Casting VCPV30 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Vermont Casting VCPV30 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)