Bedienungsanleitung York MA

16 Seiten 0.22 mb
Download

Zur Seite of 16

Summary
  • York MA - page 1

    262675-UIM-A-0806 MODULAR NON-V ARIABLE SPEED AIR HANDLERS MODELS: MA INSTALLATION MANUAL ISO 9001 Certified Quality Management System SECTION I: GENERAL This modular air handler provides the flexibility for installation in any upflow , downflow , or horizontal application. These versatile models may be used for cooling or heat pump operati on with ...

  • York MA - page 2

    262675-UIM-A-0806 2 Unitary Products Group 1. Install this air handler only in a location and position as specified in SECTION III of these instructions. 2. Always install the air handler to operate within the air handler ’s intended maximum outlet air t emperature. Only connect the air handler to a duct system which has an external static pressu ...

  • York MA - page 3

    262675-UIM-A-0806 Unitary Products Group 3 DOWNFL OW AND HORIZONT AL CONVERSION These air handler units are supplied r eady to be installed in a upflow , downflow and left or right hand horizontal position. If the unit is to be installed with an evaporator coil, refer to Figure 1 for unit positioning information. AIR HANDLER AND COIL UPFL OW AND HO ...

  • York MA - page 4

    262675-UIM-A-0806 4 Unitary Products Group DUCT CONNECT ORS Air supply and return may be handled in one of several ways best suited to the installation. See Figure 3 for dimensions for duct inlet and outlet connections. The vast majority o f problems encountered with combination heating and cooling systems can be linked to improperly designed or in ...

  • York MA - page 5

    262675-UIM-A-0806 Unitary Products Group 5 HORIZONT AL SUSPENSION For suspension of these units in hor izontal applications, it is recom- mended to use angle steel support brackets with threaded rods, sup - porting the units from the bottom, at the locations shown in Figure 4. SECTION IV : ELECTRIC HEA TER INST ALLA TION If the air handler requires ...

  • York MA - page 6

    262675-UIM-A-0806 6 Unitary Products Group NOTE: All wiring must comply with lo cal and national electrical code requirements. Read and heed all unit caution labels. NOTE: It is possible to vary the amount of electric hea t turned on during the defrost cycle of a heat pump. St andard wiring will only bring on the first stage of electric heat during ...

  • York MA - page 7

    262675-UIM-A-0806 Unitary Products Group 7 External Relay Outputs The control includes thre e outputs to drive external relays having 24 V AC coils. The outputs have a maximum rating of 1.0 Amp pilot duty at 24 V AC. HUM OUT The HUM OUT output can be used to drive an external relay or solenoid (24 V AC coil) to control a humidifier . The output is ...

  • York MA - page 8

    262675-UIM-A-0806 8 Unitary Products Group SECTION VIII: BLO WER SPEED CONNECTIONS All air handlers contain 3-speed blower motors which are prewired to the control board. Adjust blower motor speed to provide air flow within the minimum and maximum limits approved for evaporator coil, electric heat and outdoor unit. S peed tap adjustments are made a ...

  • York MA - page 9

    262675-UIM-A-0806 Unitary Products Group 9 SECTION IX: UNIT DA T A TA B L E 7 : Physical and Electrical Data Models: MA 08B21 12B21 12B41 14D21 Blower - Diameter x Width 10 x 9 10 x 9 10 x 9 10 x 10 Motor HP 1/4 HP 3/4 HP 3/4 HP 1/2 HP Nominal RPM 1075 1075 1075 1075 V oltage 208 / 230 208 / 230 460 208 / 230 Amps Full Load 1.5 3.5 2.3 2.4 Filter 1 ...

  • York MA - page 10

    262675-UIM-A-0806 10 Unitary Products Group * May be 0 (no breaker) or 1 (with breaker). TA B L E 1 1 : Electrical Data - 1 Ø - 208/23 0-1-60 Models MA Heat Kit - Single Phase Max. Stat i c Min. Spe ed Ta p To ta l H e a t 1 KW Staging KW MBH W1 Only W2 Only W1 + W2 208V 240V 208V 240V 208V 240V 208V 240V 208V 240V 08BN21 4HK*6500206 0.5 Lo 1.9 2. ...

  • York MA - page 11

    262675-UIM-A-0806 Unitary Products Group 11 * May be 0 (no breaker) or 1 (with breaker). T ABLE 13: Electrical D a t a - (For Single Source Power Supply) - Copper W ire 1 Ø - 208 /230-1-60 Models MA Heat Kit - Single Phase* Heater Amps 240V Field W iring Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C W ire Size - A WG 208V 240V 208V 240V ...

  • York MA - page 12

    262675-UIM-A-0806 12 Unitary Products Group 2. Heaters are 3 Phase. T ABLE 15: Elect rica l Data - (For Multi-Source Power Supply) - Copper W ire 3 Ø - 2 08/230-3-60 Models MA Heater Model Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C Wir e Size - A WG Circuit Circuit Circuit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/240 2 08/240 208/240 ...

  • York MA - page 13

    262675-UIM-A-0806 Unitary Products Group 13 All MA series air handler unit s are UL Listed up to 0.50" w .c. external static pressure, including air filte r , wet coil, and la rgest KW size heater . T ABLE 19: Air Flow Data - 60 Hz Models (23 0 & 460 Volt) Models MA Models MC Blower Motor Speed 230 / 460 V olt - 60 Hz CFM 1 @ External St a ...

  • York MA - page 14

    262675-UIM-A-0806 14 Unitary Products Group All MA series air handler unit s are UL Listed up to 0.50" w .c. external static pressure, including air filte r, wet coil, and la rgest KW size heater . T ABLE 20: Air Flow Data - 60 Hz Models (208 V olt) Models MA Models MC Blower Motor Speed 208 V olt - 60 Hz CFM 1 @ External St atic Pressure - IW ...

  • York MA - page 15

    262675-UIM-A-0806 Unitary Products Group 15 1. “Y” T erminal on Air Handler Control Board must be connected for full CFM and applications req uirin g 60 second blower of f del ay for SEER enhancement. 2. Optional humidity switch - contact s open on humidity rise. 3. Remove HUM ST A T Jumper on AH Control Board 4. MODE Jumper on AH control board ...

  • York MA - page 16

    Subject to change without notice. Printed in U.S.A. 262675-UIM-A-0806 Copyright © by York International Corp. 2006. Al l rights reserved. Supersedes: 170341-UIM-C-0806 Unitary 5005 Norman Product Y ork OK Group Drive 73069 NOTES ...

Produzent York Kategorie Air Cleaner

Dokumente, die wir vom Produzenten des Geräts York MA erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen MA
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York MA
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York MA.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York MA, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York MA. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York MA ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York MA, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York MA hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York MA verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York MA bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York MA befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York MA, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York MA - die uns die ersten Schritte während der Nutzung von York MA erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York MA hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York MA im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York MA?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York MA nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York MA hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)