Bedienungsanleitung American Power Conversion AP9615

22 Seiten 0.37 mb
Download

Zur Seite of 22

Summary
  • American Power Conversion AP9615 - page 1

    ® 5 Port 10Base-T Hub AP9615 ...

  • American Power Conversion AP9615 - page 2

    Thank Y ou! Thank you for selecting the APC SmartSlot 5 Port 10Base-T Hub (AP9615). It has been designed for many years of reliable, maintenance-free service in combination with your American Power Conversion (APC) uninterruptible power supply (UPS). APC is dedi- cated to the development of high-performance electrical power conversion and control p ...

  • American Power Conversion AP9615 - page 3

    i Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview 1 Features of the 5 Port 10Base-T Hub 1 Hardware requirements 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Front panel 2 APC Communications Compatibility Number 2 LEDs 3 Station ports 4 Uplink por ...

  • American Power Conversion AP9615 - page 4

    ...

  • American Power Conversion AP9615 - page 5

    1 Intr oduction Overview The SmartSlot ™ 5-Port 10Base-T Hub is an APC accessory that allows you to expand or create a local area network (LAN) by installing it in the SmartSlot of an APC UPS or expansion chassis. Featur es of the 5 Port 10Base-T Hub The following list shows some of the features of the 5 Port 10Base-T Hub. Y our hub… • Instal ...

  • American Power Conversion AP9615 - page 6

    2 Pr oduct Description Fr ont panel This figure shows the front panel of the 5 Port 10Base-T Hub. The features of the front panel are described in the paragraphs that follow . Figur e 1: Front Panel and Connect or Detail APC Communications Compatibility Number The APC Communications Compatibility Number ( CCN ), which appears on the upper left corn ...

  • American Power Conversion AP9615 - page 7

    3 Pr oduct Description continued LEDs The LEDs provide important information concerning opera- tion of the hub and each of its ports. Refer to the table below for a description of the conditions indicated by LEDs . Continued on next page Label Color Activity Description Pwr Green On The hub is receivin g p ower . Col Y ellow Blinkin g The network i ...

  • American Power Conversion AP9615 - page 8

    4 Pr oduct Description continued Station ports The Station ports are the first 4 RJ-45 ports, which are labeled 1X – 4X . The Station ports use straight-through UTP cables to connect the hub with: • W orkstations or other non-hub devices that you want to include in your network. • The Uplink port of another hub in a cascading config- uration. ...

  • American Power Conversion AP9615 - page 9

    5 Installing the Hub Wa r n i n g Do not operate the 5 Port 10Base-T Hub where conditions are outside the limits listed in “Product Specifications” on page 14. Installing on critical systems The installation procedure that follows may involve shut- ting off power from the UPS . However , if your setup requires maintaining power to connected equ ...

  • American Power Conversion AP9615 - page 10

    6 Installing the Hub continued Installation procedur e, continued Matrix- UPS ™ a Shut down and power off the connected equipment. b T urn off the circuit breaker on the bottom left side on the back panel of the UPS . Symmetra ™ Power Array ™ a Shut down and power off the connected equipment. b T urn off the System Enable switch on the bottom ...

  • American Power Conversion AP9615 - page 11

    7 Installing the Hub continued Installation procedur e, continued 3U s e a #2 Phillips head screwdriver to remove the 2 screws fastening the SmartSlot cover plate to the back panel of the UPS or triple chassis. Keep the screws for Step 5 below . Save the SmartSlot cover plate for future use (e.g. shipping the UPS ). 4 Orient the hub to fit into the ...

  • American Power Conversion AP9615 - page 12

    8 Installing the Hub continued Installation procedur e, continued 5 Secure the hub with the screws removed in Step 3. 6 Using straight-through UTP cables, connect the Sta- tion ports ( 1X – 4X , in any order) to each worksta- tion’ s 10Base-T port or to the Uplink port of a hub to be connected in cascade.(See Figure 2 on page 4.) 7 Connect the ...

  • American Power Conversion AP9615 - page 13

    9 Installing the Hub continued Installation procedur e, continued Symmetra Power Array a T urn on the System Enable switch on the bottom left side on the back panel of the UPS . b T urn on the UPS via the PowerV iew display . c Power on the connected equipment. Smart-UPS DP a T urn on the ON/OFF switch on the front panel. b Power on the connected e ...

  • American Power Conversion AP9615 - page 14

    10 Installing the Hub continued Maximum configuration Using a star configuration, you can cascade up to ten 5 Port 10Base-T hubs together to provide network connections for as many as 32 stations, as shown below in Figure 4. Note the use of a crossover cable to connect the Uplink ports of the 2 central hubs. Figur e 4: Cascading Hubs in a Star Conf ...

  • American Power Conversion AP9615 - page 15

    11 Removing the Hub Removal procedur e T o remove the 5 Port 10Base-T Hub, perform the following steps in the order given. 1 Disconnect all cables from the hub. 2 T urn off the UPS or device that houses the hub. (For detailed instructions, see “Installation procedure” on page 5.) 3U s e a #2 Phillips head screwdriver to remove the 2 screws fast ...

  • American Power Conversion AP9615 - page 16

    12 T r oubleshooting T r oubleshooting suggestions T a ble 2 provides suggestions for troubleshooting your hub. Continued on next page LED Action Cause Solution Col Blinkin g Normal data collisions on the network. No action is necessar y . Col Blinkin g excessivel y Data collisions are occurrin g because of a hi g h volume of traffic on the network ...

  • American Power Conversion AP9615 - page 17

    13 Tr o u b l e s h o o t i n g continued T r oubleshooting suggestions, continued LED Action Cause Solution Partition On 32 consecutive collisions have caused the p ort to p artition. Check that the correct cable is in use and verif y that the connected e q ui p ment is set to o p erate at 10 Mbit and half-du p lex mode. As collisions reduce, the ...

  • American Power Conversion AP9615 - page 18

    14 Specifications Pr oduct specifications The following table shows the product specifications for the 5 Port 10Base-T Hub. Item Specification Power In p ut volta g e ran g e: 18 – 30 VDC Maximum current draw: 45 mA Physical Size (H × W × D): 1.46 × 4.75 × 4.30 in (3.7 × 12.1 × 10.9 cm) We i g ht: 0.25 lb (0.1 1 k g ) Shi pp in g wei g ht: ...

  • American Power Conversion AP9615 - page 19

    15 W arranty Information Limited warranty American Power Conversion ( APC ) warrants the 5 Port 10Base-T Hub to be free from defects in materials and work- manship for a period of 2 years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective prod- ucts.This war ...

  • American Power Conversion AP9615 - page 20

    16 W arranty Information continued Obtaining service T o obtain service for your 5 Port 10Base-T Hub, follow this procedure: 1 Note the serial number and date of purchase of the hub. (The serial number is located on the top, interior surface of the hub’ s front panel.) 2 Contact APC Customer Support at the phone number or address on the back cove ...

  • American Power Conversion AP9615 - page 21

    Declaration of Conformity Application of Council Directives 89/336/EEC Standards to Which Conformity is Declared EN55022: 1995, Class B EN50082-1: 1992, including: IEC 1000-4-2: 1995 IEC 1000-4-3: 1995 IEC 1000-4-4: 1995 FCC Part 15, Class B VCCI, Class 2 Manufacturer’ s Name and Address American Power Conversion 132 Fairgrounds Road W est Kingst ...

  • American Power Conversion AP9615 - page 22

    www .apcc.com T oll-free Customer Suppor t: U. S. & Canada 1-800-800-4272 Austria 0660 6480 Belgium 0800 15063 Czech Republic 0 800 102063 Denmark 800 18 153 Finland 9800 13 374 France 0 800 906 483 Germany 01300818907 Holland 0800 0224655 Hungary 00800 12221 Ireland 1 800 702000 x 2045 Israel 177 353 2206 Italy 1678 74731 Japan 0120-80-60-90 L ...

Produzent American Power Conversion Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts American Power Conversion AP9615 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen American Power Conversion
- Bedienungsanleitungen AP9615
- Produktkarten American Power Conversion
- Informationsbroschüren
- oder Energieetiketten American Power Conversion AP9615
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung American Power Conversion AP9615.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen American Power Conversion AP9615, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen American Power Conversion AP9615. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts American Power Conversion AP9615 ansehen.

Die komplette Bedienungsanleitung des Geräts American Power Conversion AP9615, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von American Power Conversion AP9615 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von American Power Conversion AP9615 verständlich ist.

Eine gänzliche Bedienungsanleitung von American Power Conversion sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von American Power Conversion AP9615 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von American Power Conversion AP9615 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich American Power Conversion AP9615, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts American Power Conversion AP9615 - die uns die ersten Schritte während der Nutzung von American Power Conversion AP9615 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit American Power Conversion AP9615 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von American Power Conversion AP9615 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich American Power Conversion AP9615?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit American Power Conversion AP9615 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit American Power Conversion AP9615 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)