    TM P RIME DualSca n TM P RIME DualSca n TM P RIME DualSca n Ear and Forehead THERMOMETER also reads Food or Bottle temperature Please Read this Instruction Manual Before Use 70121 ...

  • Mobi DualScan Prime 70121 - page 2

    User’s Manual for DualScan ™ Prime Digital Thermometer SAFETY PREC A UTIONS 2 However, as with any thermometer, proper technique is critical to obtaining accurate temperatures. Therefore, in order to obtain an accurate measurement, please read this manual carefully before using. • Use of this thermometer is not intended as a substitution for ...

  • Mobi DualScan Prime 70121 - page 3

    3 3 KEEP INFRARED SENSOR CLEAN GOOD NOT GOOD SAFETY PREC A UTIONS (con t.) • Earwax in the ear canal or lipid on the fore- head may cause an inaccurate measurement, so make sure the ear canal or forehead is clean. • If you clean the ear or forehead, please wait 5~10 minutes before measuring. • Don't touch or blow on the infrared sensor. ...

  • Mobi DualScan Prime 70121 - page 4

    Normal body temperature varies. A person's normal temperature range tends to decrease with age. The following table shows normal temperature ranges by age: Normal temperature ranges by age: 0 – 2 years 36.4 – 38.0 °C 97.5 – 100.4 °F 3 – 10 years 36.1 – 37.8 °C 97.0 – 100.0 °F 11 – 65 years 35.9 – 37.6 °C 96.6 – 99.7 °F ...

  • Mobi DualScan Prime 70121 - page 5

    1) Forehead Button 2) Food / Object Button 3) Ear Button 4) LCD Display Screen 5) Memory Button 6) Settings Button 7) Infrared Sensor Tip 8) Forehead Probe Cover 9) Battery Cover 5 ⑦ ⑧ P A CKAGE C OMPONENTS INTERF A CE L A Y OUT 1 piece 2 pieces 1 piece DualScan Prime Thermometer 1.5V Battery(AAA) User manual ⑨ SET MEM ① ② ③ ④ ⑤ ⑥ ...

  • Mobi DualScan Prime 70121 - page 6

    1) Current Year Display 2) Temperature Display (ºF or ºC) 3) Indicates a Forehead Temperature Measurement 4) Indicates an Ear Temperature Measurement 5) Indicates Object or Food Temperature Measurement 6) Indicates Room Temperature Measurement 7) Low Battery Indicator 8) Memory Indicator 9) AM / PM Indicator 6 ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ...

  • Mobi DualScan Prime 70121 - page 7

    1. To achieve accurate measurements, it is very important to ensure that the infrared sensor is clean before using. To clean the sensor, gently wipe its surface with a cotton swab slightly moistened with alcohol and immediately wipe dry with a clean cotton swab. After cleaning, allow at least 20 minutes drying time before taking temperatures. 4. Pl ...

  • Mobi DualScan Prime 70121 - page 8

    8 SET ME M SET MEM T O MEASURE FOREHEAD TEMPERA TURE SET MEM 1. Be sure Forehead Probe Cover is snapped onto the unit before scanning. Place the thermometer in your hand as shown here with your thumb tip resting lightly on the Forehead Button . Before you press the button, make sure the Infrared Sensor Tip is clean. 2. Hold the thermometer so that ...

  • Mobi DualScan Prime 70121 - page 9

    9 SET MEM T O MEASURE EAR TEMPERA TURE 1. For Ear Scans, remove Forehead Probe Cover before use. Place the thermometer in your hand as shown here with your thumb or forenger tip resting lightly on the Ear Button . Before you press the button make sure the Infrared Sensor Tip is clean. 2. Insert the Ear Probe very gently and slowly into the ear c ...

  • Mobi DualScan Prime 70121 - page 10

    1. Remove Forehead Probe Cover . Hold the ther- mometer in your hand (as shown) with your nger tip on both the Ear Button and Forehead Button . Press the buttons simultaneously to enter into the Food / Object Mode and the display will indicate this when you see... 2. Hold the thermometer so the Infrared Sensor Tip is positioned is at a distance ...

  • Mobi DualScan Prime 70121 - page 11

    1. A temperature measurement taken in the right ear may dier from a measurement taken in the left ear. Therefore, always take the temperature in the same ear. 2. External factors may inuence ear and forehead temperatures, particularly when an individual has: • been lying on the ear to be measured or has had it covered • been exposed to ve ...

  • Mobi DualScan Prime 70121 - page 12

    12 CLEAN TIP ALERT SET MEM As a reminder to clean the probe tip, there is a special “Clean Tip Alert”. When you have not used the thermometer for a long time, or you have taken temper- ature readings multiple times, the back- light will ash for 1minute to remind you to clean the probe tip. Also, the LCD Display will show the letters “ CL ? ...

  • Mobi DualScan Prime 70121 - page 13

    The thermometer records and stores a total of nine (9) Memory Readouts of previous Ear and/or Forehead temperature measurements. The most current measurement is always saved in the last available space. Once all nine storage spaces have been occupied, with the next reading the oldest stored readout is deleted from memory as the new one is saved. To ...

  • Mobi DualScan Prime 70121 - page 14

    Press and hold the Settings Button for about 2 seconds to enter into the Settings mode. Press the Settings Button again to go to the Time / Date format and select 12hr or 24hr mode. Note: PM will display on screen when in 12hr format. Then select Hour, Minute, Year (2001~ 2099), Month, Day and whether Sleep Mode is ON or OFF. When the Sleep Mode is ...

  • Mobi DualScan Prime 70121 - page 15

    REPLA CING THE BA T TERIES 3 15 When the Low Battery Indicator appears on the screen, or the thermometer does not function at all, you should replace the batteries immediately. Note: The thermometer is pre-loaded with two (type AAA) batteries, so remem- ber to remove the plastic tab from the battery connections as shown earlier before initial use. ...

  • Mobi DualScan Prime 70121 - page 16

    THERMOMETER SPECIFIC A TIONS 16 Power supply: Body measuring range: Ear and forehead measure accuracy: Object measuring range: Object measure accuracy: Displayed room temperature range: Room temperature accuracy: Dimension: Weight: Forehead operating condition: Ear and object operating condition: Storage environment: DC 3V (2*AAA) 32.0°C ~ 42.9°C ...

  • Mobi DualScan Prime 70121 - page 17

    VERY IMPORTANT: To ensure accurate measurements, keep the probe tip clean and free of scratches, nger prints, earwax or dirt, or they will eect the accuracy of the thermometer. To clean the probe tip, gently wipe the clear surface with a cotton swab slightly moistened with alcohol and immediately wipe dry with a clean cotton swab. To clean th ...

  • Mobi DualScan Prime 70121 - page 18

    18 0197 EXPLANA TION OF SYMBOLS Type BF Applied part Disposal in accordance with Directive 2002/96/EC (WEEE) The name and the address of the manufacturer The name and the address of the authorised representative in the European Community Complies with the European Medical Device Directive (93142/EEC) and amended by directive 2007/47/EC requirements ...

  • Mobi DualScan Prime 70121 - page 19

    Problem Checklist Countermeasures Change to new batteries. Remove batteries and reinsert batteries correctly. Follow steps in User's Manual for proper measurement. Check the operation method. Contact Mobi Technologies, Inc. via the contact info at the end of this User’s Manual and report which Error Message is being displayed. Retake measure ...

  • Mobi DualScan Prime 70121 - page 20

    TROUBLESHOO TING (cont .) 20 Problem Checklist Countermeasures Clean the infrared sensor with cotton swab according to the User’s Manual. Ensure you have read the User’s Man- ual and know how to use the ther- mometer properly. Please keep the thermometer and patient in the measuring room for at least 30 minutes as mentioned in this manual. Alwa ...

  • Mobi DualScan Prime 70121 - page 21

    Dispose of the batteries in accordance with current federal, state and local regulations. As a consumer, you may be obligated by law to recycle used batteries. • In an environment in which there is electrostatic discharge, the unit may malfunction and may require user to reset the unit. • Dispose of any electronic device with care; consult the ...

Produzent Mobi Kategorie Thermometer

Dokumente, die wir vom Produzenten des Geräts Mobi DualScan Prime 70121 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Mobi
- Bedienungsanleitungen DualScan Prime 70121
- Produktkarten Mobi
- Informationsbroschüren
- oder Energieetiketten Mobi DualScan Prime 70121
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Mobi DualScan Prime 70121.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Mobi DualScan Prime 70121, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Mobi DualScan Prime 70121. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Mobi DualScan Prime 70121 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Mobi DualScan Prime 70121, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Mobi DualScan Prime 70121 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Mobi DualScan Prime 70121 verständlich ist.

Eine gänzliche Bedienungsanleitung von Mobi sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Mobi DualScan Prime 70121 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Mobi DualScan Prime 70121 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Mobi DualScan Prime 70121, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Mobi DualScan Prime 70121 - die uns die ersten Schritte während der Nutzung von Mobi DualScan Prime 70121 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Mobi DualScan Prime 70121 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Mobi DualScan Prime 70121 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Mobi DualScan Prime 70121?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Mobi DualScan Prime 70121 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Mobi DualScan Prime 70121 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)