  • State Industries SUF-100-250 - page 1

    COMMERCIAL GAS W A TER HEA TERS Instruction Manual PRINTED IN THE U . S .A. 0310 197784-001 PLACE THESE INSTRUCTIONS ADJACENT TO HEA TER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.                      ? ...

  • State Industries SUF-100-250 - page 2

    2 Supply Gas Line Installation ............................................................ 39 Supply Gas Regulator Installation ................................................... 40  ............................................................................... 41 ? ...

  • State Industries SUF-100-250 - page 3

    3 SAFE INST ALLA TION, USE AND SERVICE ? ...

  • State Industries SUF-100-250 - page 4

    4 PRE CAUT IONS                  ? ...

  • State Industries SUF-100-250 - page 5

    5 GENERAL SAFETY INFORMA TION Fire Hazard Do not install water heater on carpeted floor . Do not operate water heater if flood damaged. For continued protection against risk of fire: Fire or Explosion Hazard Read instruction manual before installing, using or servicing water heater . Avoid all ignition sources if you smell gas. Do not store or use ...

  • State Industries SUF-100-250 - page 6

    6            ? ...

  • State Industries SUF-100-250 - page 7

    7 BAS IC O PERA TION                   ...

  • State Industries SUF-100-250 - page 8

    8 1 1.   12.            ? ...

  • State Industries SUF-100-250 - page 9

    9 10.   1 1.  12.    ? ...

  • State Industries SUF-100-250 - page 10

    10   10.             ...

  • State Industries SUF-100-250 - page 11

    1 1 Figure 6 ROU GH I N DI MEN SION S INST ALLA TION CONSIDERA TIONS FRONT BACK CLEANOUT T & P V AL VE 3/4” NPT DRAIN 1 1/2” NPT WA TER INLET VENT CONNECTION 3 INCH PVC (exhaust elbow) CONDENSA TE DRAIN CONNECTION 1/2 INCH PVC INT AKE AIR CONNECTION 3 INCH PVC SUPPL Y GAS CONNECTION E H D C A I G F B WA TER OUTLET HEIGHT These designs compl ...

  • State Industries SUF-100-250 - page 12

    12 STORAGE CAP ACITIES T ABLE 2 MODEL U. S. GALLONS LITERS  60 227  100 379  100 379  100 379 GAS LINE CONNECTION SIZE T ABLE 1 † MODEL SERIES NA TURAL GAS PROP ANE GAS  100/101 3/4 "N ...

  • State Industries SUF-100-250 - page 13

    13                ? ...

  • State Industries SUF-100-250 - page 14

    14 POW ER S UPPL Y                     ...

  • State Industries SUF-100-250 - page 15

    15 HOT W A TER OUTLET TO T ANK INLET CHECK V AL VE MIXING V AL VE COLD W A TER INLET TEMPERED W A TER OUTLET 12” TO 15” (30-38 cm) CHECK V AL VE Figure 8      ? ...

  • State Industries SUF-100-250 - page 16

    16 W ater Damage Hazard T emperature-Pressure Relief V alve discharge pipe must terminate at adequate drain. • C A U T I O N T&P V alve Discharge Pipe Requirements:  Shall not be smaller in size than the outlet pipe size of the ? ...

  • State Industries SUF-100-250 - page 17

    17 CON DENS A TE D RAI N                  ? ...

  • State Industries SUF-100-250 - page 18

    18 UNUSUALL Y TIGHT CONSTRUCTION                ...

  • State Industries SUF-100-250 - page 19

    19                ...

  • State Industries SUF-100-250 - page 20

    20 AIR FRO M OT HER IND OOR SP ACE S Figure 14              ...

  • State Industries SUF-100-250 - page 21

    21 COM MONW EAL TH OF MA SSAC HUSE TTS             ...

  • State Industries SUF-100-250 - page 22

    22        2.  ...

  • State Industries SUF-100-250 - page 23

    23                    ? ...

  • State Industries SUF-100-250 - page 24

    24 MINIMUM EQUIV ALENT LENGTHS Three Inch Pipe                    ...

  • State Industries SUF-100-250 - page 25

    25 9.                ...

  • State Industries SUF-100-250 - page 26

    26 14.          ? ...

  • State Industries SUF-100-250 - page 27

    27 VER TICA L TERM INA TION INS T ALLA TION 1.  NOTE:       ? ...

  • State Industries SUF-100-250 - page 28

    28 2” (5 cm) MAXIMUM F ACTOR Y SUPPLIED ST ANDARD TERMINA TION POINTED DOWN T OWARDS THE GROUND VERTICAL TERMINA TION(S) INST ALLA TION INT AKE AIR AND/OR VENT (EXHAUST) FIELD SUPPLIED 90° ELBOW FIELD SUPPLIED STRAP/SUPPORT FIELD SUPPLIED PLUMBING ROOF BOOT OR FLASHING MAINT AIN 12” (30 cm) 18” (45 cm) FOR CANADA MINIMUM CLEARANCE ABOVE HIGH ...

  • State Industries SUF-100-250 - page 29

    29 SID EW ALL TER MIN A TION INS T ALLA TION 1.  NOTE:       ? ...

  • State Industries SUF-100-250 - page 30

    30 NOTE:                    ? ...

  • State Industries SUF-100-250 - page 31

    31 4 I NCH CONC ENT RIC TERM INA TION INST ALLA TION 4 INCH CONCENTRIC TERMINA TION KIT FOUR PIECE KIT - FIELD ASSEMBL Y REQUIRED VENT PIPE INT AKE AIR CONNECTION 3 INCH PVC VENT CONNECTION - 3 INCH PVC INT AKE AIR PIPE Y FITTING ASSEMBL Y VENT CAP VENT PIPE ASSEMBL Y VENT PIPE IS 2 1/2 INCH SDR-26 PIPE SUPPLIED LENGTH 37 INCHES (94 cm) MAXIMUM ALL ...

  • State Industries SUF-100-250 - page 32

    32 Four Concentric T erminations 1.                ...

  • State Industries SUF-100-250 - page 33

    33 Four Concentric T erminations              ? ...

  • State Industries SUF-100-250 - page 34

    34 VEN TING ARR ANG EMEN TS Power V ent V ertical Figure 40 Direct V ent V ertical Figure 42 Power V ent Horizontal Figure 41 Direct V ent Horizontal Figure 43 ...

  • State Industries SUF-100-250 - page 35

    35 VEN TING ARR ANG EMEN TS Direct V ent V ertical V ent Horizontal Intake Figure 44 Direct V ent V ertical Concentric Figure 46 Direct V ent Horizontal V ent V ertical Intake Figure 45 Direct V ent Horizontal Concentric Figure 47 ...

  • State Industries SUF-100-250 - page 36

    36 TER MINA TION CLE ARA NCES SID EW ALL POW ER V ENT V X VENT TERMINAL AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED v v A G V FIXED CLOSED FIXED CLOSED OPERABLE OPERABLE V C B B B B F B V V A J V H M X X V V K B E D L POWER VENT (using room air for combustion) EXTERIOR CLEARANCES FOR SIDEW ALL VENT TERMINA TION Figure 48 V ent terminal c ...

  • State Industries SUF-100-250 - page 37

    37 TER MINA TION CLE ARA NCES SID EW ALL DIR ECT VEN T V X VENT TERMINAL AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED v v A G V FIXED CLOSED FIXED CLOSED OPERABLE OPERABLE V C B B B B F B V V A J V H M X X V V K B E D L DIRECT VENT (using outdoor air for combustion) EXTERIOR CLEARANCES FOR SIDEW ALL VENT TERMINA TION Figure 49 V ent termi ...

  • State Industries SUF-100-250 - page 38

    38 W A TER HEA TER INST ALLA TION  3. DO NOT          INST ALLA TION INSTRUCTIONS 1.   ...

  • State Industries SUF-100-250 - page 39

    39 SUP PL Y GAS LINE INS T ALLA TION                  ...

  • State Industries SUF-100-250 - page 40

    40 GAS LINE CONNECTION 1.        ? ...

  • State Industries SUF-100-250 - page 41

    41   Connecting An External Supervisory Control       ? ...

  • State Industries SUF-100-250 - page 42

    42 T&P V AL VE DISC HARG E P IPE Explosion Hazard T em per at ur e- Pre ss ur e Rel ie f V alv e must comply with ANSI Z21.22- CSA 4.4 and ASME code. Properly sized temperature- pressure relief valve must be installed in opening provided. Can result in overheating and excessive tank pressure. Can cause serious injury or death.  ? ...

  • State Industries SUF-100-250 - page 43

    43                   ? ...

  • State Industries SUF-100-250 - page 44

    44 THE DESKTOP SCREEN                  ? ...

  • State Industries SUF-100-250 - page 45

    45 ST A TUS ICONS    ? ...

  • State Industries SUF-100-250 - page 46

    46 OPERA TING ST A TES            ? ...

  • State Industries SUF-100-250 - page 47

    47 USE R SE TTIN GS & CO NTRO L SYS TEM MENU S TEMPERA TURES MENU Operating Set Point And Differential Adjustment             ? ...

  • State Industries SUF-100-250 - page 48

    48 TEMPERA TURES MENU (CONT) DESCRIPTION/ACTION DISPLA Y  T ank T emperature   ? ...

  • State Industries SUF-100-250 - page 49

    49 DISPLA Y SETTINGS DESCRIPTION/ACTION DISPLA Y                ? ...

  • State Industries SUF-100-250 - page 50

    50 CURRENT F AUL T DESCRIPTION/ACTION DISPLA Y                 ...

  • State Industries SUF-100-250 - page 51

    51 SERVICE CONT ACT INFORMA TION  ? ...

  • State Industries SUF-100-250 - page 52

    52 PRI OR T O ST ART UP                   ...

  • State Industries SUF-100-250 - page 53

    53  8.          ? ...

  • State Industries SUF-100-250 - page 54

    54 SUPPL Y GAS PRESSURE ADJUSTMENT Fire and Explosion Hazard T urn off gas lines during installation. Contact a qualified installer or service agency for installation and service. Excessive gas pressure to gas valve can cause serious injury or death. Do not use water heater with any gas other than the gas shown on the rating label. ? ...

  • State Industries SUF-100-250 - page 55

    55 CHE CKIN G TH E F IRIN G RA TE            ...

  • State Industries SUF-100-250 - page 56

    56 LIGHTING THE W A TER HEA TER OFF REG ADJUST ON F L O W FOR YOUR SAFETY READ BEFORE OPERA TING TO TURN OFF GAS T O APPLIANCE OPERA TING INSTRUCTIONS W ait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go on to the next step. IF YOU DO NOT ...

  • State Industries SUF-100-250 - page 57

    57 T ank T emperature 103°F Operating Set Point 120°F Status: Heating MENU HELP UP DN GAS OFF O N MODEL INFORMA TION ON/OFF SWITCH FOR YOUR SAFETY READ BEFORE OPERA TING TO TURN OFF GAS T O APPLIANCE OPERA TING INSTRUCTIONS IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y ...

  • State Industries SUF-100-250 - page 58

    58 SEQ UENC E OF OP ERA TION                 ...

  • State Industries SUF-100-250 - page 59

    59 SEQ UENC E OF OP ERA TION FLOW CHA RT YE S N O W ater is hea t ed t o s e t poin t 24 Volt Ga s V a lv e de - en er giz ed 30 sec o nd I n t e r -Pur ge cy c le 24 Volt Ga s V a lv e de - ene rg iz ed R etrie s up t o t wo mor e ti mes 30 sec on d Pos t-Purg e c y cl e C on t r ol S ys t e m Lo c k s Ou t “Ign it ion Failur e ” Fau lt M sg i ...

  • State Industries SUF-100-250 - page 60

    60        ? ...

  • State Industries SUF-100-250 - page 61

    61 ALERT CONDITIONS                 ? ...

  • State Industries SUF-100-250 - page 62

    62 F AUL T AND ALERT MESSAGES                ...

  • State Industries SUF-100-250 - page 63

    63 F AUL T AND ALERT MESSAGES (CONT)               ? ...

  • State Industries SUF-100-250 - page 64

    64 MAI NTEN ANCE SC HEDU LE T ABLE 14 COMPONENT OPERA TION INTERV AL REQUIRED T ank  Removal Semi Annually  T ank  Removal Semi Annually UN-LIME®    Annually ? ...

  • State Industries SUF-100-250 - page 65

    65 T ANK CLEANOUT OPENING CLEANOUT COVER CLEANOUT GASKET CLEANOUT ACCESS P ANEL Figure 63 MANUAL LIME SCALE REMOV AL NOTE:       ? ...

  • State Industries SUF-100-250 - page 66

    66 DISCHARGE PIPE TEMPERA TURE-PRESSURE RELIEF V AL VE                ? ...

  • State Industries SUF-100-250 - page 67

    67 DIAGRAMS CCB - C ENTR AL CO NTRO L BOAR D LA YO UT 1 Re t ry Us e Yes Typ e Tstat Sp ar e Ext I nput 3 Retrie s N o V en t S pa re O PE N 1 2 3 4 3 2 1 6 5 4 9 8 7 12 11 10 15 14 13 J 6 J 7 3 2 4 1 1 2 J 1 5 8 4 5 6 7 1 2 3 J 1 3 3 4 1 2 J 1 0 1 3 5 2 4 J 1 1 3 4 2 J 2 1 4 2 1 2 J 3 J 5 J 4 S1 D IPSWITCH J 1 6 J 9 J 1 1 S1 DIPSWITCH DET AIL CCB ...

  • State Industries SUF-100-250 - page 68

    68 SUF 120 & 1 50 WIRI NG D IAGR AM 2 GREEN WHITE RED BLACK 1 1 2 BLACK 3 WHITE COMBUSTION BLOWER UPP ER T EMPE RATU RE P ROBE 1 RED (ECO) 4 RED (ECO) 2 BLACK 3 BLACK 1 BLACK120 VAC HOT 3 WHITE 120 VAC NEUTRAL 4 YEL 24 VAC 4 YEL 24 VAC LOWER TEMPERATURE PROBE HOT SURFACE IGNITER FLAME SENSOR BLOCKED AIR INTAKE BLOCKED EXHAUST BLOWER PROVER 24 V ...

  • State Industries SUF-100-250 - page 69

    69 SUF 199 & 2 50 WIRI NG D IAGR AM 2 GREEN WHITE RED BLACK 1 1 2 BLACK 3 WHITE COMBUSTION BLOWER UPP ER T EMPE RATU RE P ROBE 1 RED (ECO) 4 RED (ECO) 2 BLACK 3 BLACK 1 BLACK120 VAC HOT 3 WHITE 120 VAC NEUTRAL 4 YEL 24 VAC 4 YEL 24 VAC LOWER TEMPERATURE PROBE HOT SURFACE IGNITER FLAME SENSOR BLOCKED AIR INTAKE BLOCKED EXHAUST BLOWER PROVER 24 V ...

  • State Industries SUF-100-250 - page 70

    70 CIR CULA TION PUM P WIR ING DIAG RAMS Figure 68 Figure 69 CIRCULA TING PUMP WIRING DIAGRAM STORAGE T ANK OR BUILDING RECIRCULA TION FIELD SUPPLIED TEMPERA TURE CONTROL INST ALLED IN THE STORAGE T ANK OR CIRCULA TING LOOP RETURN LINE CIRC PUMP MOTOR L1 HOT L2 NEUTRAL 120 V AC POWER NOTE: USE SEP ARA TE 120 V AC POWER SUPPL Y FOR PUMP CIRCUIT . DO ...

  • State Industries SUF-100-250 - page 71

    71 4.  5.   6.    ...

  • State Industries SUF-100-250 - page 72

    72 4.  5.   6.    ...

  • State Industries SUF-100-250 - page 73

    73 4.  5.   6.    ...

  • State Industries SUF-100-250 - page 74

    74 4.  5.   6.    ...

  • State Industries SUF-100-250 - page 75

    75 4.  5.   6.    ...

  • State Industries SUF-100-250 - page 76

    76 4.  5.   6.    ...

  • State Industries SUF-100-250 - page 77

    77 4.  5.   6.    ...

  • State Industries SUF-100-250 - page 78

    78 LIMITED W ARRANTY     ? ...

  • State Industries SUF-100-250 - page 79

    79 ...

  • State Industries SUF-100-250 - page 80

             ...

Produzent State Industries Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts State Industries SUF-100-250 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen State Industries
- Bedienungsanleitungen SUF-100-250
- Produktkarten State Industries
- Informationsbroschüren
- oder Energieetiketten State Industries SUF-100-250
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung State Industries SUF-100-250.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen State Industries SUF-100-250, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen State Industries SUF-100-250. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts State Industries SUF-100-250 ansehen.

Die komplette Bedienungsanleitung des Geräts State Industries SUF-100-250, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von State Industries SUF-100-250 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von State Industries SUF-100-250 verständlich ist.

Eine gänzliche Bedienungsanleitung von State Industries sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von State Industries SUF-100-250 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von State Industries SUF-100-250 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich State Industries SUF-100-250, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts State Industries SUF-100-250 - die uns die ersten Schritte während der Nutzung von State Industries SUF-100-250 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit State Industries SUF-100-250 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von State Industries SUF-100-250 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich State Industries SUF-100-250?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit State Industries SUF-100-250 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit State Industries SUF-100-250 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen