    H4i ™ HEATED HUMIDIFIER User Guide English Global leaders in sleep and respiratory medicine www.resmed.com 248672/1 2013-02 H4i USER EUR 1 - ENG 1 2 4 5 Filling the wat er chamber / A uf füllen der Bef eucht er kammer / Remplissag e du r éservoir / Riempiment o della camera dell’acqua / Llenado de la cámar a de agua / Encher a câmar a de á ...

  • ResMed 1 h4i - page 2

    Manufa cturer: ResMed Ltd 1 Elizabeth Mac arthur Drive Bella Vista NSW 2153 A ustralia. Distributed by: ResMed Corp 9001 Spectrum Center Bou levard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Milton Park Abi ngdon Oxfordshire OX14 4RY UK. See www. resmed.com for other ResMed locations worl dwide. For patent info rmation, see www.resmed.com /ip. H4i, ...

  • ResMed 1 h4i - page 3

    Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Indications for use 1 Contraindications 1 Components of your H4i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 S etting up your H4 i for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • ResMed 1 h4i - page 4

    1 Introduction English Introduction The H4i ™ is designed to moi sten the air delivered to your airway during Positive Airway Pressure (PAP) therapy. Indications for use The H4i is indicated for humidification of the air del ivered from a ResMed compatible CPAP, bilevel an d non-invasive ventilation device. The H4i is for use only as recommended ...

  • ResMed 1 h4i - page 5

    2 System setup 1 Align your H4i wi th your flow generator an d push them together until they c lick into place. 2 Connect the power cord to the socket on the rear of your flow generator. 3 Plug the other end of the power cord into the power outlet. Place the combined unit on a firm, level surfac e near your bed at a level lower than your sleeping p ...

  • ResMed 1 h4i - page 6

    3 Setting up your H4i for use English Filling the water chamber 1 Open the cover. 2 Remove the water chamber. 3 Fill with fresh, clean water up to or below the maxim um water level mark. Note: T he water c hamber must be remo ved from the H4i before it is filled or water may enter the flo w generator . The sp ill guard must also be in place. 4 Retu ...

  • ResMed 1 h4i - page 7

    4 4 Pull the H4i and flo w generator apart. Note : Re-attach the connector plug firmly to your flow generator. Starting and stopping treatment Warming your H4i with the VPAP or S8 Series The Warm-Up feature (not available on all Re sMed PAP d evices) is used to pre-heat the water before starting treatm ent. Skip this step if you want to start immed ...

  • ResMed 1 h4i - page 8

    5 Cleaning and maintenance English ! WARNING Do not leave a n excessive length of ai r tubing around the top o f your bed. It could twist around your head or neck while you are sleepin g. Stopping your treatment To stop your treatment, refer to your device user guid e. Note : In orde r to assist the heater plate in cooling, some flow generato rs co ...

  • ResMed 1 h4i - page 9

    6 Cleaning your H4i Water chamber Daily Wash the water chamber, spill guard, tub pl ate and tub plate seal in warm wate r, using a mild d etergent. Use the yellow cleanin g plug to assist in the clea ning process (see steps 1 to 4). Rinse thoro ughly in clean water and allow them to dry away from direct sunlight. Weekly The disassembled cl eanable ...

  • ResMed 1 h4i - page 10

    7 Cleaning and maintenance English Cover and cover seal 1 Remove the cover by gently flexing one cover arm away and up from the docking station until the cover detaches compl etely. 2 Peel the cover seal away from the cover. 3 Inspect the cover and cover seal weekly for wear and deteriorati on. Replace any damaged parts. When required, wa sh the co ...

  • ResMed 1 h4i - page 11

    8 4 Reinsert the sp ill guard into th e water chamber recess and pus h down to fit firmly into place. Reassembling your H4i Reassemble the parts when they are clean and dry. 1 Align the cover seal to the guides on the cover and press along the edges to ensure it is fitted properly. 2 Put one cover arm in to its pivot point on the docki ng station a ...

  • ResMed 1 h4i - page 12

    9 T roubleshooting English Troubleshooting If there is a p roblem, try the following suggestions. If the problem cannot b e solved, contact your equipment supplier or ResMed. Do not open the unit. ! WARNING Service and repair should only be pe rformed by a n authorise d service ag ent. Pro ble m Possible cause Sol ut i on Devi ce not w orking (no d ...

  • ResMed 1 h4i - page 13

    10 Technical specifications Humidifier performance The following setting s have been tested at 22°C, 40% RH ambient conditions: Note : The manufacturer reserves the right to cha nge these specifications without notic e. Maximum heate r plate temper atur e 85°C T emperatur e cut-out 93°C Maximum gas t emperatur e 41°C Dimensions (H x W x D) Doc ...

  • ResMed 1 h4i - page 14

    11 General warnings English Symbols which appear on the device Caution; Read instructions before use; European Authorised Representative; Type BF Applied Part; Hot surface; Class II equipment; Do not touch; Humidifier c ontrol; Max imum water level; Manufacturer; Environmenta l information WEEE 2002/96/EC is a E uropean Directive that requires the ...

  • ResMed 1 h4i - page 15

    12 Limited warranty ResMed Ltd (hereafter ’ResMed’) warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below. This warranty is only availabl e to the initial consumer. It is not transferable. If the product fails under conditions of norma l use, ResMed will ...

  • ResMed 1 h4i - page 16

    H4i ™ HEATED HUMIDIFIER User Guide English Global leaders in sleep and respiratory medicine www.resmed.com 248672/1 2013-02 H4i USER EUR 1 - ENG 1 2 4 5 Filling the wat er chamber / A uffüllen der Bef euchter kammer / Remplissage du r éservoir / Riempiment o della camera dell’acqua / Llenado de la cámar a de agua / Encher a câmar a de água ...

Produzent ResMed Kategorie Oxygen Equipment

Dokumente, die wir vom Produzenten des Geräts ResMed 1 h4i erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen ResMed
- Bedienungsanleitungen 1 h4i
- Produktkarten ResMed
- Informationsbroschüren
- oder Energieetiketten ResMed 1 h4i
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung ResMed 1 h4i.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen ResMed 1 h4i, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen ResMed 1 h4i. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts ResMed 1 h4i ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts ResMed 1 h4i, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von ResMed 1 h4i hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von ResMed 1 h4i verständlich ist.

Eine gänzliche Bedienungsanleitung von ResMed sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von ResMed 1 h4i bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von ResMed 1 h4i befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich ResMed 1 h4i, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts ResMed 1 h4i - die uns die ersten Schritte während der Nutzung von ResMed 1 h4i erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit ResMed 1 h4i hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von ResMed 1 h4i im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich ResMed 1 h4i?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit ResMed 1 h4i nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit ResMed 1 h4i hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.