Bedienungsanleitung Lincoln Electric SP-135T

36 Seiten 0.97 mb
Download

Zur Seite of 36

Summary
  • Lincoln Electric SP-135T - page 1

    SP- 135T OPERA TOR’S MANUAL IM785 April, 2004 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND ...

  • Lincoln Electric SP-135T - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric SP-135T - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric SP-135T - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric SP-135T - page 5

    iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les ...

  • Lincoln Electric SP-135T - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric SP-135T - page 7

    vi vi MASTER T ABLE OF CONTENTS FOR ALL SECTIONS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Identify and Locate Components ...................... ...

  • Lincoln Electric SP-135T - page 8

    A-1 SP-135T A-1 Fuse or Output Mode Input Voltage Breaker Size 1 Input Amps Power Cord Extension Cord Three Conductor #14 AWG ( 2.1 mm 2 ) or Larger RATED 120V/60Hz 20 Amp 20 15 Amp, 125V, Up to 25 Ft. (7.6 mm) Three Prong Plug Three Conductor (NEMA Type 5-15P) #12 AWG (3.3 mm 2 ) or Larger Up to 50 Ft. (15.2 mm) INST ALLA TION TECHNICAL SPECIFICA ...

  • Lincoln Electric SP-135T - page 9

    A-2 INST ALLA TION SP-135T A-2 Read entire installation section before starting installation. SAFETY PRECAUTIONS IDENTIFY AND LOCA TE COMPONENTS If you have not already done so, unpack the SP-135T from its carton and remove all packing material around the SP-135T. Remove the following loose items from the carton (see Figure A.1): 1. SP-135T 2. Gun ...

  • Lincoln Electric SP-135T - page 10

    A-3 INST ALLA TION SP-135T A-3 SP-135T 4 5 8 3 6 7 1 2 DO NOT SWITCH WHEN WELDING + - FIGURE A.2 Work Clamp Installation Attach the work clamp per the following: 1. Unplug the machine or turn the power switch to the “OFF” position. 2. Insert the work cable terminal lug with the larger hole through the strain relief hole in the work clamp as sho ...

  • Lincoln Electric SP-135T - page 11

    Work Cable Installation Refer to Figure A.2. 1. Open the wire feed section door on the right side of the SP-135T. 2. Pass the end of the work cable that has the termi- nal lug with the smaller hole through the Work Cable Access Hole (1) in the case front. 3. Route the cable under and around the back of the Wire Feed Gearbox (6). 4. For GMAW Only: R ...

  • Lincoln Electric SP-135T - page 12

    CYLINDER may explode if dam- aged. Keep cylinder upright and chained to support • Keep cylinder away from areas where it may be damaged. • Never lift welder with cylinder attached. • Never allow welding electrode to touch cylinder. • Keep cylinder away from welding or other live electrical circuits. BUILDUP OF SHIELDING GAS may harm health ...

  • Lincoln Electric SP-135T - page 13

    A-6 INST ALLA TION SP-135T A-6 INPUT CONNECTIONS Refer to Figure A.6. The SP-135T has a power input cable located on the rear of the machine. FIGURE A.6 CODE REQUIREMENTS FOR INPUT CONNECTIONS This welding machine must be connected to a power source in accordance with applicable elec- trical codes. The National Electrical Code provides standards fo ...

  • Lincoln Electric SP-135T - page 14

    B-1 OPERA TION B-1 SP-135T Read entire operation section before operating the SP-135T . ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. Insulate yourself from work and ground. • Always wear dry insulating gloves. FUMES AND GASES can be dangerous. • Keep your head out of fumes. • Use ve ...

  • Lincoln Electric SP-135T - page 15

    B-2 OPERA TION B-2 5. Gun Trigger - Activates welding output, wire feed, and gas solenoid operation. Releasing the trigger deactivates welding and simultaneously activates the “burnback” function so that the welding wire does not stick in the weld puddle. FIGURE B.1a FIGURE B.1b ● No external shielding gas is required when used with Lincoln I ...

  • Lincoln Electric SP-135T - page 16

    B-3 OPERA TION B-3 WELDING OPERA TIONS SEQUENCE OF OPERA TION Wire Loading Refer to Figures B.2 and B.3. The machine power switch should be turned to the OFF (“O”) position before working inside the wire feed enclosure. The welder is shipped from the factory ready to feed 8" (200 mm) diameter spools with 2.2" (56 mm) maxi- mum width. ...

  • Lincoln Electric SP-135T - page 17

    B-4 OPERA TION B-4 Friction Brake Adjustment With wire spool installed on the spindle shaft and the wing nut loose, turn the spool by hand while slowly tightening the wing nut until a light drag is felt. Tighten the wing nut an additional 1/4 turn. Note: When properly adjusted, the brake should pro- vide only enough drag to prevent overrun of the s ...

  • Lincoln Electric SP-135T - page 18

    B-5 OPERA TION B-5 FIGURE B.6 Making A Weld 1. See “Process Guidelines” in this section for selec- tion of welding wire and shielding gas and for range of metal thicknesses that can be welded. 2. See the Application chart on the inside of the wire feed compartment door for information on setting the SP-135T controls. Refer to Table B.1 for alu- ...

  • Lincoln Electric SP-135T - page 19

    B-6 OPERA TION B-6 The SP-135T is suitable for .035" aluminum wire and .030" stainless wire. Refer to Table B.1 for recom- mended procedure settings (requires K499 Argon Regulator Kit). TABLE B.1 * NR (Not Recommended) CHANGING MACHINE OVER T O FEED OTHER WIRE SIZES The SP-135T is shipped from the factory ready to feed .023”-.025” (0. ...

  • Lincoln Electric SP-135T - page 20

    B-7 APPLICA TION CHART B-7 SP-135T ...

  • Lincoln Electric SP-135T - page 21

    INNERSHIELD (FCA W) CONVERSION Several changes are needed to convert the unit for operation with the Innershield (FCAW) process. The K549-1 or K549-2 Innershield Kits include all the nec- essary accessories for this conversion and are provid- ed for this purpose. The following conversions should be made using the contents of this kit: 1. Change the ...

  • Lincoln Electric SP-135T - page 22

    C-2 ACCESSORIES C-2 REPLACEMENT P ARTS Complete Gun and Cable Assembly L8311-6 (K530-4) Contact Tip .025” (0.6 mm) KP2039-1B1 Contact Tip .030” (0.8 mm) KP2039-2B1 Contact Tip .035” (0.9 mm) KP2039-3B1 Contact Tip-Tapered .025” (0.6 mm) KP2052-1B1 Contact Tip-Tapered .030” (0.8 mm) KP2052-2B1 Contact Tip-Tapered .035” (0.9 mm) KP2052-3B ...

  • Lincoln Electric SP-135T - page 23

    MAINTENANCE SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Disconnect input power by removing plug from receptacle before working inside SP-135T. Use only grounded receptacle. Do not touch electrically “hot” parts inside SP-135T. • Have qualified personnel do the mainte- nance and trouble shooting work. ROUTINE MAINTENANCE POWER SOURCE COMP ...

  • Lincoln Electric SP-135T - page 24

    D-2 MAINTENANCE D-2 SP-135T GUN AND CABLE MAINTENANCE FOR MAGNUM™ 100L GUN Gun Cable Cleaning Clean cable liner after using approximately 300 lbs (136 kg) of solid wire or 50 lbs (23 kg) of flux-cored wire. Remove the cable from the wire feeder and lay it out straight on the floor. Remove the contact tip from the gun. Using low pressure air, gent ...

  • Lincoln Electric SP-135T - page 25

    D-3 MAINTENANCE D-3 SP-135T COMPONENT REPLACEMENT PROCEDURES CHANGING THE CONT ACT TIP 1. Refer to Figure D.2. Remove the gas nozzle from the gun by unscrewing counter-clockwise. 2. Remove the existing contact tip from the gun by unscrewing counter-clockwise. 3. Insert and hand tighten desired contact tip. 4. Replace gas nozzle. CHANGING DRIVE ROLL ...

  • Lincoln Electric SP-135T - page 26

    GUN HANDLE P ARTS The gun handle consists of two halves that are held together with a collar on each end. To open up the handle, turn the collars approximately 60 degrees counter-clockwise until the collar reaches a stop. Then pull the collar off the gun handle. If the collars are diffi- cult to turn, position the gun handle against a corner, place ...

  • Lincoln Electric SP-135T - page 27

    E-1 TROUBLESHOOTING E-1 SP-135T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair possible ...

  • Lincoln Electric SP-135T - page 28

    E-2 TROUBLESHOOTING E-2 SP-135T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SYMPTOMS) Major physical or electrical damage is evident. No wire f ...

  • Lincoln Electric SP-135T - page 29

    E-3 TROUBLESHOOTING E-3 SP-135T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SYMPTOMS) No wire feed when gun trigger is pulled. Fan runs, gas fl ...

  • Lincoln Electric SP-135T - page 30

    E-4 TROUBLESHOOTING E-4 SP-135T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SYMPTOMS) Arc is unstable – Poor starting POSSIBLE AREAS OF MISAD ...

  • Lincoln Electric SP-135T - page 31

    F-1 DIAGRAMS F-1 SP-135T W A RNING HIGH VOLTAGE can kill Only qualified persons should install, use or ser vice this machine. Do not operate with covers removed. Disconnect input power by unplugging power cord before servicing. Do not touch electrically live parts 7-02 M20138 S1 SW ITCH D1 D3 D2 D4 204 204 204 203 203 203 C1 59,000 f 40V 203 204 GU ...

  • Lincoln Electric SP-135T - page 32

    NOTES SP-135T ...

  • Lincoln Electric SP-135T - page 33

    NOTES SP-135T ...

  • Lincoln Electric SP-135T - page 34

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA EL ...

  • Lincoln Electric SP-135T - page 35

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes fr ...

  • Lincoln Electric SP-135T - page 36

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Produzent Lincoln Electric Kategorie Welder

Dokumente, die wir vom Produzenten des Geräts Lincoln Electric SP-135T erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lincoln Electric
- Bedienungsanleitungen SP-135T
- Produktkarten Lincoln Electric
- Informationsbroschüren
- oder Energieetiketten Lincoln Electric SP-135T
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lincoln Electric SP-135T.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lincoln Electric SP-135T, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lincoln Electric SP-135T. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lincoln Electric SP-135T ansehen.

Die komplette Bedienungsanleitung des Geräts Lincoln Electric SP-135T, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lincoln Electric SP-135T hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lincoln Electric SP-135T verständlich ist.

Eine gänzliche Bedienungsanleitung von Lincoln Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lincoln Electric SP-135T bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lincoln Electric SP-135T befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lincoln Electric SP-135T, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lincoln Electric SP-135T - die uns die ersten Schritte während der Nutzung von Lincoln Electric SP-135T erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lincoln Electric SP-135T hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lincoln Electric SP-135T im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lincoln Electric SP-135T?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lincoln Electric SP-135T nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lincoln Electric SP-135T hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)