    Buying an ice machine is a decision you will live with for a long time. For the money, you want an ice machine that delivers more performance for less cost, over a longer period of time. You want Cornelius. Efficient Water/Electrical Compressors and condensers are matched precisely to provide the perfect balance between water and electrical use. Al ...

  • Cornelius pmnice systems - page 3

    *See warranty for details. TH E LONG HAUL. TH E LONG HAUL. Self-Insulated ABS Evaporator Housing Nickel-Plated Copper Evaporator Insulated, Double-W all Bulkhead In-Line W ater Pump Microban ® Antimicrobial Product Protection Programmable W ater Control Quick-Change Merchandising Panel Front-Mounted LED Future Proof R-404a Refrigerant Exclusive Ic ...

  • Cornelius pmnice systems - page 4

    PRODUCTION CHART AIR-COOLED W ater T emperature (˚F) Air T emp (˚F) 50 70 80 70 46 lbs. 41 lbs. 40 lbs. 80 44 lbs. 40 lbs. 40 lbs. 90 42 lbs. 38 lbs. 35 lbs. S eries 50† Series 200 SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient W ater W ater V oltage Number Condenser T ype Electrical Capa ...

  • Cornelius pmnice systems - page 5

    C U B E R S 5 Series 300"Xtreme" ARI CERTIFIED PERFORMANCE Ice Harvest Potable Water KWH Condenser Model Rate Use Consumption Water Use Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. XAC322/XAC330 269 16.7 8.5 n/a XWC322/XWC330 269 16.7 6.8 149 DIMENSIONS/CAP A CITY PLUMBING Model Nominal Cabinet Water Electrical Service N ...

  • Cornelius pmnice systems - page 6

    Series 600"Xtreme" ARI CERTIFIED PERFORMANCE Ice Harvest Potable Water KWH Condenser Model Rate Use Consumption Water Use Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. XAC630 547 16.3 6.9 n/a XWC630 589 17.4 5.6 116 XRC630 547 16.3 6.9 n/a SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shippi ...

  • Cornelius pmnice systems - page 7

    Series 800"Xtreme" ARI CERTIFIED PERFORMANCE Ice Harvest Potable W ater KWH Condenser Model Rate Use Consumption W ater Use Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. XAC830 666 16.3 6.9 n/a XWC830 700 17.4 5.6 116 XRC830 666 16.3 6.9 n/a SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Ship ...

  • Cornelius pmnice systems - page 8

    Series 1400"Xtreme" SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water V oltage Number Condenser T ype Electrical Capacity Fuse Size W eight Weight T emperature T emperature Pressure Range XAC1444 Air -Cooled R-404a 208/230/60/1 30 30 317 lbs. 274 lbs. 50°F-100°F 45°F-90? ...

  • Cornelius pmnice systems - page 9

    C U B E R S C H U N K L E T S 9 Series 2448 SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water W ater Voltage Number Condenser T ype Electrical Capacity Fuse Size Weight W eight T emperature T emperature Pressure Range IRC2448 AC Remote* R-404a 208-230/60/1 30 30 396 lbs. 335 lbs. 50°F-100 ...

  • Cornelius pmnice systems - page 10

    C H U N K L E T S 10 Series 1000 DIMENSIONS/CAP A CITY PLUMBING Model Nominal Cabinet W ater Electrical Service Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening WCC-1001A 1015 lbs. 22"w x 24"d x 27"h SS 1 ⁄ 4 " male flare 3 ⁄ 8 " I.D. x 9 ⁄ 16 " O.D. 7 ⁄ 8 " diameter hole WCC-1001W 1015 l ...

  • Cornelius pmnice systems - page 11

    C H U N K L E T S F L A K E R S 11 Series 2000 DIMENSIONS/CAP A CITY PLUMBING Model Nominal Cabinet W ater Electrical Service Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening WCC-2001A 1999 lbs. 30"w x 24"d x 28"h SS 1 ⁄ 4 " male flare 3 ⁄ 8 " I.D. x 9 ⁄ 16 " O.D. 7 ⁄ 8 " diameter hole WC ...

  • Cornelius pmnice systems - page 12

    F L A K E R S 12 Series 725 SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water W ater Voltage Number Condenser T ype Electrical Capacity Fuse Size Weight Weight T emperature T emperature Pressure Range AF725PSCR Air-Cooled R-404a 115/60/1 20 20 334 lbs. 300 lbs. 50°F-100°F 50°F-90°F 20- ...

  • Cornelius pmnice systems - page 13

    F L A K E R S D I S P E N S E R S 13 Series 2000 DIMENSIONS/CAP A CITY PLUMBING Model Nominal Cabinet W ater Electrical Service Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening WCF-2201A 2506 lbs. 30"w x 24"d x 28"h SS 1 ⁄ 4 " male flare 3 ⁄ 8 " I.D. x 9 ⁄ 16 " O.D. 7 ⁄ 8 " diameter hole ...

  • Cornelius pmnice systems - page 14

    D I S P E N S E R S A C C E S S O R I E S 14 Remote Condensers •W eatherproof housing •H igh-efficiency copper and aluminum condenser •R educes air conditioning requirements Cabinet Finish: Galvanized Cornelius Bagger •T ime-saving • No mess • Less melting • Convenient • Innovative design Dimensions: 22"w x 10 1 ⁄ 4 "d x ...

  • Cornelius pmnice systems - page 15

    B I N S 15 • Wide Selection… T welve models ranging from 120 to 1315 lbs. storage capacity . • Corrosion Proof… All Cornelius storage bins constructed of rotomolded polyethylene or 304 grade stainless steel are virtually corrosion proof. Our standard baked enamel finished bins will provide years of corrosion resistant service. • Easy Main ...

  • Cornelius pmnice systems - page 16

    S P E C I F I C A T I O N G U I D E 16 LOCATION Always locate the ice machine where ambient temperatures will not fall below 50˚F nor rise above 100˚F . CLEARANCE Always make certain the machine and storage bin will fit through all doors and hallways leading to the final installation site. When installed, there must be a 6-inch air clearance on r ...

  • Cornelius pmnice systems - page 17

    S P E C I F I C A T I O N G U I D E 17 The quick reference sizing guide works well in many cases; however , more and more customers’ ice needs are changing. T oday’ s customers use ice for numerous applications such as product cooling, self-serve beverages, product packaging, display and, in some cases, retail package sales. T o meet customer n ...

  • Cornelius pmnice systems - page 18

    S P E C I F I C A T I O N G U I D E 18 The previous sizing methods assume that the icemaker will run continuously 24 hours a day . This total utilization of the icemaker gives the customer the most cost effective way of producing the required ice. It also requires the bin to be properly sized or the cus- tomer will run out of ice. The example below ...

  • Cornelius pmnice systems - page 19

    S P E C I F I C A T I O N G U I D E 19 A GENERAL REVIEW OF THE RULES FOR SIZING ICEMAKERS AND BINS 1. Ice needs are seldom uniform; more ice is generally needed in summer than in winter . Understanding the ice usage of the customer is a must to assure sufficient ice is available to meet peak demands. Remember , water temperature, as well as the sur ...

  • Cornelius pmnice systems - page 20

    CA TG 8699 © 2002 IMI Cornelius www .cornelius.com ...

Produzent Cornelius Kategorie Ice Maker

Dokumente, die wir vom Produzenten des Geräts Cornelius pmnice systems erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Cornelius
- Bedienungsanleitungen pmnice systems
- Produktkarten Cornelius
- Informationsbroschüren
- oder Energieetiketten Cornelius pmnice systems
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Cornelius pmnice systems.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Cornelius pmnice systems, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Cornelius pmnice systems. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Cornelius pmnice systems ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Cornelius pmnice systems, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Cornelius pmnice systems hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Cornelius pmnice systems verständlich ist.

Eine gänzliche Bedienungsanleitung von Cornelius sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Cornelius pmnice systems bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Cornelius pmnice systems befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Cornelius pmnice systems, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Cornelius pmnice systems - die uns die ersten Schritte während der Nutzung von Cornelius pmnice systems erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Cornelius pmnice systems hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Cornelius pmnice systems im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Cornelius pmnice systems?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Cornelius pmnice systems nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Cornelius pmnice systems hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)