Bedienungsanleitung Interphase Tech U1-BBFF-DFN

35 Seiten 1.21 mb
Download

Zur Seite of 35

Summary
  • Interphase Tech U1-BBFF-DFN - page 1

    50-200 FISH FINDER Dual Frequency 50 & 200kHz Black Box Fish Finder CODE: B-300806 User Manual Copyright 2006 Interphase Technologies Inc. All rights reserved. Printed in Italy. No part of this publication may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without prior written permission ...

  • Interphase Tech U1-BBFF-DFN - page 2

    4 User Manual Contents Important Information ............................................................................... 6 WARRRANTY STATEMENT ............................................................................... 6 CAUTION ............................................................................... 6 About this User Manual ........ ...

  • Interphase Tech U1-BBFF-DFN - page 3

    5 User Manual 3.1.10.4 Fish Symbols ........................................................................ 21 3.1.10.5 Water Temperature ............................................................... 22 3.1.11 Transducer Setup ............................................................................. 22 3.1.11.1 Keel Offset .................. ...

  • Interphase Tech U1-BBFF-DFN - page 4

    6 User Manual Important Information WARRRANTY STATEMENT Interphase T echnologies, Inc. warrants this unit to be free from defects in material and workmanship. During the w arranty period, Interphase T echnologies, Inc. will repair or replace any component which fails in normal use without charges for parts or labour . T o receive warranty service, ...

  • Interphase Tech U1-BBFF-DFN - page 5

    7 User Manual About this User Manual INTRODUCTION The chart plotter combined with the sonar performance of the Fish Finder is one of the most advanced marine navigation system available. Please read carefully this User Manual to learn the operating features for your unit. Refer to your chart plotter User Manual for all other unit oper ating instruc ...

  • Interphase Tech U1-BBFF-DFN - page 6

    8 User Manual HOW THIS USER MANUAL IS ORGANIZED ♦ CHAPTER 1: Overview Introduction to the basic information on the Fish Finder , its features and use. ♦ CHAPTER 2: Fish Finder Helps you understand how the chart plotter is connected to the Fish Finder and how to operate to impro ve your fishing. ♦ ♦ ♦ ♦ ♦ CHAPTER 3: Setup your Fish Fin ...

  • Interphase Tech U1-BBFF-DFN - page 7

    9 User Manual 1 . Overview The Fish Finder consists of a high power transmitter , sensitive receiver and a transducer . The Fish Finder sends an electrical pulse to the transducer which contains an element that converts the pulse into acoustic (sound) wave which is sent through the water . As this wave travels from the tr ansducer to the bottom, it ...

  • Interphase Tech U1-BBFF-DFN - page 8

    10 User Manual ♦ STC (allows reducing or eliminating the surface clutter) ♦ Interference Rejection (allows reducing interference from other boats/ Fish Finders) ♦ Noise Filter ♦ Fish Symbol feature (*) ♦ Automatic T ransducer Setup. R ecognition for devices (automatic trasducer identification and par ameters setup for best performance) ? ...

  • Interphase Tech U1-BBFF-DFN - page 9

    11 User Manual 2 . Fish Finder This chapter is intended to help you understand how the chart plotter with the Fish Finder connected operates to improve y our fishing. 2.1 UNDERSTANDING THE FISH FINDER PAGE The display on chart plotters shows a history of time of the echoes received by the transducer . The chart plotters have a menu that allows adju ...

  • Interphase Tech U1-BBFF-DFN - page 10

    12 User Manual Digital Depth Readout of the current bottom depth. Water Temperature Readout of the current water temper ature returned by the TEMP 1 sensor included into specific transducers. Alarm Bar Bars showing the shallow water and deep water alarm v alues. The alarm is triggered when depth is outside the range. Depth ruler V ertical graduated ...

  • Interphase Tech U1-BBFF-DFN - page 11

    13 User Manual fish, causing a display pixel to be turned on. As the boat passes over the fish, the distance to the fish decreases turning each pixel on at a shallower depth on the display . When the boat is directly o v er the fish, the first half of the arch is formed and since the fish is closer to the boat, the signal is stronger and the arch i ...

  • Interphase Tech U1-BBFF-DFN - page 12

    14 User Manual Fig. 2.2.1 - Page Selection menu The menu now shows four selections related to the Fish Finder , Full Display, 50/ 200kHz Full Display, Zoom Full Display and Chart/Fish display . Move the cursor to select the desired item and then press [ENTER] . NOTE When the Radar* is connected, two other displaying pages are available too, Radar/F ...

  • Interphase Tech U1-BBFF-DFN - page 13

    15 User Manual Fig. 2.2.2a - Sensitivity sub-menu Pressing [CLEAR] turns off the Sensitivity menu. The CLEAR key By pressing [CLEAR] the Variable Depth Mark er (VDM) is hidden. The ZOOM IN and ZOOM OUT keys From this page pressing [ZOOM IN] once changes to Zoom 2X, pressing [ZOOM IN] twice changes to Zoom 4X, while pressing [ZOOM OUT] reverts to Zo ...

  • Interphase Tech U1-BBFF-DFN - page 14

    16 User Manual Fig. 2.2.4 - Fish Finder Zoom Page The Depth Cursor is shown only on the unzoomed Fish Finder Display . The ZOOM IN and ZOOM OUT keys From this page pressing [ZOOM IN] changes to Z oom 4X, pressing [ZOOM OUT] changes to Z oom 2X. 2.2.5 Chart/Fish Display page T o display the Chart page on the left half of the screen and the Fish Find ...

  • Interphase Tech U1-BBFF-DFN - page 15

    17 User Manual Fig. 2.2.6 - Radar/FF page Otherwise to display the Radar and Fish Finder Combo pages, follow this procedure: [PAGE] + "Radar/FF/Chart/Nav Data" + [ENTER] Fig. 2.2.6a - Combo page When in Split/Combo pages, the active view is highlighted by a focus (Y ellow frame). The keyboard commands are related to that focused view . T ...

  • Interphase Tech U1-BBFF-DFN - page 16

    18 User Manual below the bottom of the screen, automatically moves up/down the current zoomed Fish Finder Display view and re-position the V ariable Depth Marker (VDM) at the center of the screen. NOTE Pressing [CLEAR] hides the Depth Cursor and if the Fish Finder is in Auto Range or Bottom Lock mode switches into Bottom Lock Zoom mode. 2.4 INFO ON ...

  • Interphase Tech U1-BBFF-DFN - page 17

    19 User Manual 3 . Setup your Fish Finder 3.1 FISH FINDER SETUP MENU The Fish Finder Setup menu provides access to additional functions, setup and layout/data field options. From the Fish Finder page, access this menu by pressing: [MENU] Fig. 3.1 - Fish Finder Setup menu 3.1.1 Preset Mode Allows applying the following Fish Finder operating mode pre ...

  • Interphase Tech U1-BBFF-DFN - page 18

    20 User Manual Bottom Lock. [MENU] + "BOTTOM RANGE" + [ENTER] 3.1.5 Depth This option is available only when R ange Mode is Manual and it is disabled in Auto Range and Bottom Lock Mode. [MENU] + "DEPTH" + [ENTER] 3.1.6 Shift Shows the depth from which start the bottom scanning. This option is available only when Range Mode is Ma ...

  • Interphase Tech U1-BBFF-DFN - page 19

    21 User Manual increases. This is for the purpose of filtering out surface clutter . 3.1.9.4 STC Length If STC is Custom, it is possible to change the Length of the Sensitivity Time Constant. 3.1.9.5 STC Strength If STC is Custom, it is possible to change the Strength of the Sensitivity Time Constant. 3.1.9.6 Surface Noise Filter This function impl ...

  • Interphase Tech U1-BBFF-DFN - page 20

    22 User Manual Icon : shows Fish icons Icon + Depth : shows Fish icons and their depth (accordingly to currently selected depth unit) The Fish icons displayed are among four different shapes depending on the size of the T arget (Small, Med, Big, Huge). 3.1.10.5 Water Temperature Allows you to choose the W ater T emperature label displayed over the ...

  • Interphase Tech U1-BBFF-DFN - page 21

    23 User Manual Fig. 3.1.12 - Fish Finder Alarms menu 3.1.12.1 Shallow Water T riggers an alarm when depth becomes shallower than the value set. 3.1.12.2 Depth Water T riggers an alarm when depth becomes deeper than the value set. 3.1.12.3 Temperature Upper T riggers an alarm when the transducer reports a temperature (from TEMP 1 sen- sor) above the ...

  • Interphase Tech U1-BBFF-DFN - page 22

    24 User Manual ...

  • Interphase Tech U1-BBFF-DFN - page 23

    25 User Manual 4 . 50-200 FISH FINDER This chapter provides instructions to assist in planning the installation of the 50-200 FISH FINDER. 4.1 TECHNICAL SPECIFICATIONS ♦ Display Colors : 1 6 colors on color chart plotter or 16 gray levels on gray levels chart plotter ♦ Display V ertical Resolution : up to 400 pixels (depending on chart plotter ...

  • Interphase Tech U1-BBFF-DFN - page 24

    26 User Manual When the package containing the 50-200 FISH FINDER is first opened, please check it for the following contents (if any parts are missing contact the dealer the 50-200 FISH FINDER was purchased from): ♦ 50-200 FISH FINDER (with P ower Serial and optional devices cables already connected) ♦ User Manual 4.2 DIMENSIONS Fig. 4.2 - 50- ...

  • Interphase Tech U1-BBFF-DFN - page 25

    27 User Manual Fig. 4.3.1 - The 50-200 FISH FINDER Installation ♦ Fix the 50-200 FISH FINDER to the mounting location using the four screws (holes diameter 4 mm), see Fig. 4.3.2. ♦ Route the CHAR T PLOT TER cable to the chart plotter . ♦ Mount the transducer according to the instructions provided with it. ♦ Connect the POWER cable to the ba ...

  • Interphase Tech U1-BBFF-DFN - page 26

    28 User Manual 4.5 EXTERNAL CONNECTIONS Fig. 4.5 - 50-200 FISH FINDER External Wiring 4.6 POWER SUPPLY WIRING DIAGRAM W e recommended the installation of a switch and a (5A) fuse in the positive DC supply to the 50-200 FISH FINDER. The 50-200 FISH FINDER is active sending the digital depth through the NMEA interface even when the power (chart plott ...

  • Interphase Tech U1-BBFF-DFN - page 27

    29 User Manual In the example below you will notice the positive DC power connection is run through a switch and a fuse before connecting it to the 50-200 FISH FINDER and the chart plotter . Fig.4.6 - The 50-200 FISH FINDER Power Connection 4.7 CHART PLOTTER CONNECTION DIAGRAM If the chart plotter has a quick disconnect bracket (see the chart plott ...

  • Interphase Tech U1-BBFF-DFN - page 28

    30 User Manual Fig.4.7a - Connection to the Fish Finder for chart plotter with 8 pin Power & I/O connector ...

  • Interphase Tech U1-BBFF-DFN - page 29

    31 User Manual 5 . Transducers The transducer is a device that transmits and receives sound w aves into the water . The active component inside the transducer is commonly referred to as an element but actually is a piezoelectric ceramic material. Please refer to your dealer and/or installer to choose your transducer . Interphase suggest transducers ...

  • Interphase Tech U1-BBFF-DFN - page 30

    32 User Manual ...

  • Interphase Tech U1-BBFF-DFN - page 31

    33 User Manual 6 . Frequently Asked Questions 6.1 How can I disconnect the cables from the 50-200 FISH FINDER in case I need to do so for the installation? ♦ Open the 50-200 FISH FINDER box unscrewing the four screws (see the following figure). Fig. 6.1 - The 50-200 FISH FINDER (I) ♦ Once the screws are removed, pull out the panel and the Print ...

  • Interphase Tech U1-BBFF-DFN - page 32

    34 User Manual Fig. 6.1b - The 50-200 FISH FINDER (III) 6.2 How can I set optimal operating parameters. Optimal operating par ameters can be set accordingly with the intended use of the Fish Finder , anyway to quickly get optimal operational par ameters for fishing it is possible to select the FISH preset from the Fish Finder Setup menu, while for ...

  • Interphase Tech U1-BBFF-DFN - page 33

    35 User Manual 6.7 What should I do if the auto modes fail? F ailure of auto modes can happen for various reasons. Hereafter you can find a range of possibilities. 6.8 Auto-range fails in very shallow waters displaying a digital depth readout deeper than the actual value. What should I do? This usually happens if the STC is set to LONG or MID and t ...

  • Interphase Tech U1-BBFF-DFN - page 34

    36 User Manual 6.12 Why do I never see fish in the range between 0 to 0.7 meters? The minimum range of the fish finder is 0.7 meters. In this interv al the Fish Finder can detect neither the bottom nor any target. 6.13 How can I reduce the surface clutter? Y ou can act by: properly setting the STC as described at 6.12 and also by increas- ing the N ...

  • Interphase Tech U1-BBFF-DFN - page 35

    37 User Manual Index 50-200 FISH FINDER ................................. 26 50/200kHz Full Display .............................. 14 A A-Scope ............................................... 9, 12 Alarm ..................................... 10, 12, 22, 23 Alarm Bar ................................................ 12 B Bottom Echo Profile ......... ...

Produzent Interphase Tech Kategorie Fish Finder

Dokumente, die wir vom Produzenten des Geräts Interphase Tech U1-BBFF-DFN erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Interphase Tech
- Bedienungsanleitungen U1-BBFF-DFN
- Produktkarten Interphase Tech
- Informationsbroschüren
- oder Energieetiketten Interphase Tech U1-BBFF-DFN
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Interphase Tech U1-BBFF-DFN.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Interphase Tech U1-BBFF-DFN, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Interphase Tech U1-BBFF-DFN. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Interphase Tech U1-BBFF-DFN ansehen.

Die komplette Bedienungsanleitung des Geräts Interphase Tech U1-BBFF-DFN, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Interphase Tech U1-BBFF-DFN hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Interphase Tech U1-BBFF-DFN verständlich ist.

Eine gänzliche Bedienungsanleitung von Interphase Tech sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Interphase Tech U1-BBFF-DFN bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Interphase Tech U1-BBFF-DFN befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Interphase Tech U1-BBFF-DFN, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Interphase Tech U1-BBFF-DFN - die uns die ersten Schritte während der Nutzung von Interphase Tech U1-BBFF-DFN erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Interphase Tech U1-BBFF-DFN hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Interphase Tech U1-BBFF-DFN im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Interphase Tech U1-BBFF-DFN?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Interphase Tech U1-BBFF-DFN nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Interphase Tech U1-BBFF-DFN hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)