    UPFLO W/HORIZONT AL 2-ST A GE, V ARIABLE SPEED GAS-FIRED FURNA CE PUB. NO . 22-1650-13 XV 80 MODELS TUD2B060A9V3VB , TUD2B080A9V3VB TUD2C080A9V4VB , TUD2C080B9V4VB TUD2B100A9V3VB , TUD2C100A9V5VB TUD2C100B9V5VB , TUD2D120A9V5VB TUD2D120B9V5VB , TUD2D140A9V5VB © 2011 T rane T w o-Stage F anAssisted Comb ustionSystem ...

  • Trane TUD2D120B9V5VB - page 2

    2 22-1650-13 General Features © 2011 T rane NA TURAL GAS MODELS Central Heating furnace designs are cer- tified by the American Gas Association f or both natural and L.P . gas. Limit setting and rating data were estab lished and approv ed under standar t rating condi- tions using American National Standards Instirute standards. SAFE OPERA TION Th ...

  • Trane TUD2D120B9V5VB - page 3

    3 22-1650-13 Featur e Summar y Featur es and Benefits Standard Equipment Optional Equipment General Data TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB TUD2C080B9V4VB TUD2B100A9V3VB TUD2C100A9V5VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D120B9V5VB TUD2D140A9V5VB Per formance Data Electric Data Field Wiring Diagrams Dimensions Contents 2 4 4 5 6 9 19 19 24 ...

  • Trane TUD2D120B9V5VB - page 4

    4 22-1650-13 XV80 ST AND ARD EQUIPMENT • Upow/Horizontaland • P owersupply115/1/60 • 2-stagegasvalv e • 2-speedventer • V ar iab lespeedblowermotor • SiliconNitridehotsurfaceigniterwith adaptive heat up • Integratedsolidstatecontrol • Attractiv ec ...

  • Trane TUD2D120B9V5VB - page 5

    5 22-1650-13 XV80 OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling ........................................................................................ T A YST A T241 [ ] Thermostat, Mechanical Heating Only With F an Switch ............................................................................................. BA ...

  • Trane TUD2D120B9V5VB - page 6

    6 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 T emp . rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TUD2D120B9V5VB - page 7

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 7 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 T emp . rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype D ...

  • Trane TUD2D120B9V5VB - page 8

    8 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 T emp . rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TUD2D120B9V5VB - page 9

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 9 *UD2B060A9V3VB FURNA CE COOLING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 1.5 LOW (350 CFM/ T ON) ON ON OFF ON CFM W A TTS 499 50 537 80 ...

  • Trane TUD2D120B9V5VB - page 10

    10 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2B080A9V3VB FURNA CE COOLING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.5 LOW (350 CFM/T ON) OFF ON OFF ON CFM W A TTS 880 120 ...

  • Trane TUD2D120B9V5VB - page 11

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 11 *UD2C080A9V4VB FURNA CE HEA TING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 782 49 75 762 51 110 751 51 145 748 51 ...

  • Trane TUD2D120B9V5VB - page 12

    12 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2C080B9V4VB FURNA CE HEA TING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 974 49 133 968 49 285 949 50 202 925 ...

  • Trane TUD2D120B9V5VB - page 13

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 13 *UD2B100A9V3VB FURNA CE HEA TING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 751 64 86 796 61 132 817 59 175 832 58 ...

  • Trane TUD2D120B9V5VB - page 14

    14 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2C100A9V5VB FURNA CE HEA TING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 900 53 100 890 54 130 870 55 175 850 ...

  • Trane TUD2D120B9V5VB - page 15

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 15 *UD2C100B9V5VB FURNA CE HEA TING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 953 50 93 944 50 146 936 51 193 908 52 ...

  • Trane TUD2D120B9V5VB - page 16

    16 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2D120A9V5VB FURNA CE HEA TING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW7 SW8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1007 57 114 1062 54 177 1084 53 285 106 ...

  • Trane TUD2D120B9V5VB - page 17

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 17 *UD2D120B9V5VB FURNA CE HEA TING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE S4-3 S4-4 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1050 45 99 1044 46 146 1035 46 208 100 ...

  • Trane TUD2D120B9V5VB - page 18

    18 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2D140A9V5VB FURNA CE HEA TING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1090 62 130 1100 61 175 1070 63 215 1 ...

  • Trane TUD2D120B9V5VB - page 19

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 19 PRODUCT D A T A WIRING DIA GRAM F rom Dwg. D344249P02 ...

  • Trane TUD2D120B9V5VB - page 20

    20 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT D A T A SCHEMA TIC DIA GRAMS F rom Dwg. D344249P02 ...

  • Trane TUD2D120B9V5VB - page 21

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 21 PRODUCT D A T A FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING ONL Y F rom Dwg. 21B341127 Rev . 0 F rom Dwg. 21B341126 Rev . 0 FIELD WIRING DIA GRAM FOR TW O ST A GE HEA TING TO 115 V 1 PH., 60 HZ., POWER SUPPL Y PER LOCAL CODES M M M M M M S S S S S S S S S S S S S S S S S S S S S S S S S S ...

  • Trane TUD2D120B9V5VB - page 22

    22 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT D A T A FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING WITH SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg. 21B341125 Rev . 1 F rom Dwg. 21B341124 Rev . 1 FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING WITH SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANS ...

  • Trane TUD2D120B9V5VB - page 23

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 23 PRODUCT D A T A FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING WITH TW O ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg. 21B341128 Rev . 0 TO 115 V 1 PH., 60 HZ., PO E S S S S S S S E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E ...

  • Trane TUD2D120B9V5VB - page 24

    24 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT D A T A TUD-9V OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) F rom Dwg. C341699 MODEL A B C D *UD2B060A9V3V** *UD2B080A9V3V** *UD2B100A9V3V** 17-1/2" 9-5/8" 16-1/4" 16" *UD2C080A9V4V** *UD2C100A9V5V** *UD2C080B9V4V** *UD2C100B9V5V** 21" 13-1/16" 19-3/4&qu ...

  • Trane TUD2D120B9V5VB - page 25

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 25 ...

  • Trane TUD2D120B9V5VB - page 26

    Since the manufacturer has a policy of contin uous product and product data improvement, it reserves the right to change the design and specifications without notice. T echnical Literature - Pr inted in U .S .A. T rane 6200 T roup Highw ay T yler , TX 75707 PRODUCT D A T A ...

Produzent Trane Kategorie Furnace

Dokumente, die wir vom Produzenten des Geräts Trane TUD2D120B9V5VB erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Trane
- Bedienungsanleitungen TUD2D120B9V5VB
- Produktkarten Trane
- Informationsbroschüren
- oder Energieetiketten Trane TUD2D120B9V5VB
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Trane TUD2D120B9V5VB.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Trane TUD2D120B9V5VB, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Trane TUD2D120B9V5VB. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Trane TUD2D120B9V5VB ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Trane TUD2D120B9V5VB, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Trane TUD2D120B9V5VB hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Trane TUD2D120B9V5VB verständlich ist.

Eine gänzliche Bedienungsanleitung von Trane sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Trane TUD2D120B9V5VB bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Trane TUD2D120B9V5VB befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Trane TUD2D120B9V5VB, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Trane TUD2D120B9V5VB - die uns die ersten Schritte während der Nutzung von Trane TUD2D120B9V5VB erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Trane TUD2D120B9V5VB hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Trane TUD2D120B9V5VB im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Trane TUD2D120B9V5VB?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Trane TUD2D120B9V5VB nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Trane TUD2D120B9V5VB hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)