Bedienungsanleitung Superior CFPF-CMP

24 Seiten 0.59 mb
Download

Zur Seite of 24

Summary
  • Superior CFPF-CMP - page 1

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 903589 REV. E 02/2004 CFST -CMN CFPF-CMN CFST -CMP CFPF-CMP MODELS ST ANDARD SERIES INST ALLA TION INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS. DO NOT BUILD A WOOD FIRE. FOR YOUR SAFETY: Do not store or use gasoline or other flammable v ...

  • Superior CFPF-CMP - page 2

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 GENERAL INFORMATION The CFST and CFPF Series Unvented Room Heaters covered in this manual feature ceramic fiber split logs which glow realistically when the heater is operating. These heaters have a standing pilot and are manually controlled through the use of a milli- volt gas valve. A spark igniti ...

  • Superior CFPF-CMP - page 3

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN- STRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING UNVENTED ROOM HEATER, VOIDING ITS WAR- RANTY. ANY CHANGE TO THIS HEATER AND/OR ITS OPERATING CONTROLS IS DANGEROUS. IMPROPER INSTALLA- TION O ...

  • Superior CFPF-CMP - page 4

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Example: CFST/PF heater 34,000 BTU/Hr Gas appliance #1 32,000 BTU/Hr (water heater) Total = 66,000 BTU/Hr * Do not include direct-vent gas appliances. Direct-vent is sealed combustion and draws combustion air from the outdoors. 4 . Compare the maximum BTU/Hr the space can support with the actual amo ...

  • Superior CFPF-CMP - page 5

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 41 ⁵⁄₈ ” (1210 mm) Figure 1 A hearth extension is not required with this appliance. If a hearth extension is used, do not block the lower control compartment door. Any ...

  • Superior CFPF-CMP - page 6

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 CFST FRAMING SPECIFICATIONS CFST APPLIANCE SPECIFICATIONS A 22 ³⁄₄ " (578 mm)* B 43" (1092 mm) Min. C 43" (1092 mm) Min. Framing Dimensions Figure 3 Figure 4 Figure 5 C A B Gas Line 2 x 4 Wall Framing T op View * ¹⁄₂ " (13mm) Required Air Space Clearance Drywall * Gas L ...

  • Superior CFPF-CMP - page 7

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 6 Figure 7 Figure 8 C A B Gas Line CFPF FRAMING SPECIFICATIONS CFPF APPLIANCE SPECIFICATIONS Gas Line Energy Wall 2 x 4 Outside Wall Drywall Dr ywall * Bracket Bracket Framing T op View * ¹⁄₂ " (13mm) Required Air Space Clearance A 22 ³⁄₄ " (578 mm)* B 40 ¹⁄₈ " ( ...

  • Superior CFPF-CMP - page 8

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Step 2 . Route a ¹⁄₂ " (13 mm) gas line along the left or right side framing ( Figure 9 ). All appliances have a 3" long ³⁄₈ " NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV. Figure 11 The gas con ...

  • Superior CFPF-CMP - page 9

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Step 7. Installing the Optional Remote Wall Switch – The standard millivolt system comes from the factory wired as shown in Figure 12 . Select a convenient location for the remote wall switch and connect the wiring to the appliance ( Figure 13 ). CAUTION: DO NOT CONNECT THE OPTIONAL REMOTE SWITCH ...

  • Superior CFPF-CMP - page 10

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Assembling the Logs WARNING: DO NOT ADD EXTRA LOGS OR ORNAMENTS SUCH AS PINE CONES, VERMICULITE OR ROCK WOOL. USING THESE ADDED ITEMS CAN CAUSE SOOTING. Figure 15 Step 9. The heater includes a set of ceramic fiber logs. The logs are assembled as shown in Figure 15 . Handle these logs with great car ...

  • Superior CFPF-CMP - page 11

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 The installation of the logs and twigs, should be complete and resemble Figures 15, 16 and 19 . After setting the logs and rockwool into posi- tion as described above, ensure the logs are properly and firmly situated. The heater will not function as intended if the logs are not correctly positioned ...

  • Superior CFPF-CMP - page 12

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face. Tarnishing of these pieces is normal, unavoidable and should be expected. Forced Air Kit The F ...

  • Superior CFPF-CMP - page 13

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 Gas Flex Line with Valve A gas flex line kit is available to aid in attaching the appliance to the gas supply. This kit can only be used where local codes permit. The kit includes a ¹⁄₂ " NPT to ³⁄₈ " flare in line shut-off valve, a 12" flex line ³⁄₈ " female flar ...

  • Superior CFPF-CMP - page 14

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Remote Control Kit RCK Rocker Switch Kit RS Wall Switch Kit WSK Gas Flex Line Kit GFLV Decorative Volcanic Stone DVS 4-Piece Decorative Arch Frame Kit -Main Panel DAT-6-4 -End Panel DAET-6-4 1-Piece Decorative Arch Frame Kit -Main Panel DAT-6-1 -En ...

  • Superior CFPF-CMP - page 15

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open. 3. Locate gas control knob and piezo. 4. Depress control knob in and turn clockwise to the “OFF” position ( Figure 23 ) ...

  • Superior CFPF-CMP - page 16

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force. Figure 23 Pilot Location Figure 24 Figure 25 Turn Control Knob to “OFF” Position Turn Control Knob to “PILOT” Position EA TPTH TP TH P I L O T H I L O W P I L O T O N it O F F EA T ...

  • Superior CFPF-CMP - page 17

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 CFST REPLACEMENT PARTS LIST CFST GAS CONTROLS — MILLIVOLT CFST-CMN CFST-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123071 1 123072 1 2. Bar, Louver (Black) 104951 8 104951 8 3. Hood (Black), Clean Face 108971 2 108971 2 4. Screw 000861 6 000861 6 5. Replacement Glas ...

  • Superior CFPF-CMP - page 18

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS – CFST 8 20 9 21 22 23 a. b. c. d. f. g. e. 3 2 1 7 6 2 11 4 5 10 ...

  • Superior CFPF-CMP - page 19

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 CFPF REPLACEMENT PARTS LIST CFPF GAS CONTROLS — MILLIVOLT CFPF-CMN CFPF-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123073 1 123074 1 2. Bar, Louver (Black) - Main Panel 104951 8 104951 8 3. Bar, Louver (Black) - End Panel 104955 4 104955 4 4. Hood (Black), Clean Fac ...

  • Superior CFPF-CMP - page 20

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 REPLACEMENT PARTS – CFPF 11 20 12 21 22 23 13 4 2 1 10 14 7 6 2 5 3 3 9 a. b. c. d. e. 8 f. g. ...

  • Superior CFPF-CMP - page 21

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 21 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position. 5. When igniter button is pressed, there is spark at ODS/pilot, but no ignition. 6. ODS/pilot ...

  • Superior CFPF-CMP - page 22

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 22 ...

  • Superior CFPF-CMP - page 23

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 23 ...

  • Superior CFPF-CMP - page 24

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 24 Printed in U.S.A. © 1997 by SFC P/N 903589 REV. E 02/2004 Catalytic Gas Fireplace Manufacturer's Limited W arranty 10 Y ears THE WARRANTY The manufacturer warrants the components of this Catalytic Gas Fireplace manufactured by SFC, INC. (hereinafter, SFC) to be free from defects in materials ...

Produzent Superior Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Superior CFPF-CMP erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Superior
- Bedienungsanleitungen CFPF-CMP
- Produktkarten Superior
- Informationsbroschüren
- oder Energieetiketten Superior CFPF-CMP
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Superior CFPF-CMP.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Superior CFPF-CMP, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Superior CFPF-CMP. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Superior CFPF-CMP ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Superior CFPF-CMP, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Superior CFPF-CMP hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Superior CFPF-CMP verständlich ist.

Eine gänzliche Bedienungsanleitung von Superior sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Superior CFPF-CMP bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Superior CFPF-CMP befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Superior CFPF-CMP, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Superior CFPF-CMP - die uns die ersten Schritte während der Nutzung von Superior CFPF-CMP erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Superior CFPF-CMP hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Superior CFPF-CMP im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Superior CFPF-CMP?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Superior CFPF-CMP nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Superior CFPF-CMP hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)