Bedienungsanleitung Sentry Industries Sentry 2.0

32 Seiten 1.29 mb
Download

Zur Seite of 32

Summary
  • Sentry Industries Sentry 2.0 - page 1

    1 Sentry 2.0 Digital Temperature Controller Complete Operating Instructions See pages 28-29 for instructions on upgrading your DTC 100, 600, 800 or 1000 series board to the Sentry. Delay (pg 6) From IdLE, press 3. Enter time in hours:minutes. Delays the start of firing. Program Review (pg 6) From IdLE or during firing, press 6. Shows the program th ...

  • Sentry Industries Sentry 2.0 - page 2

    2 Introduction Thank you for purchasing the Sentry micro processor, our most advanced generation of digi - tal temperature controllers. The easiest way to learn to operate the Sentry is to sit down in front of it with these instructions and play with it. Spend time understanding the controller before you begin to use it. Damage caused by failure to ...

  • Sentry Industries Sentry 2.0 - page 3

    3 Contents Basic Pointers . . . . . . . . . . 4 Which Instructions Apply to Your Controller . . . . . . . . . . 4 Room Temperature and Humidity . . . 4 Thunder Storms and Power Surges . 4 Display Lights . . . . . . . . . . . . . . . . . . 5 How to Get IdLE to Display . . . . . . . . 5 Firing Completion Message . . . . . . . 5 Repeat Firings . . . . ...

  • Sentry Industries Sentry 2.0 - page 4

    Safety The warranty on your Sentry controller does not cover damage from overfiring, regardless of the circumstances. It is the operator’s responsibility to make sure the kiln turns off at the end of the firing. Follow these safety rules in addition to the ones in your kiln or furnace manual. When the kiln is not in use, disconnect the power and ...

  • Sentry Industries Sentry 2.0 - page 5

    Display Lights Single Center Light: Time A lower center dot appears during time display. It sepa - rates hours from minutes (i.e. 1 hour, 30 minutes displays as 01.30). During temperature display, the dot disappears. Power Output Lights The Sentry turns on the heating elements intermittently through relays. The power output lights in the right side ...

  • Sentry Industries Sentry 2.0 - page 6

    Chapter 2 The Keys Correcting Entries If you enter the wrong temperature, cone, time, etc., while programming, enter 0000. Then enter the correct numbers before pressing ENTER . See also the Stop/Back Key, page 7. 1 / Cone Fire Cone-Fire is a method of firing ceramics to a pyrometric cone. See Chapter 3, page 8, for details. To find out if your Sen ...

  • Sentry Industries Sentry 2.0 - page 7

    Setting Alarm From Idle 1 From IdLE , press 7 . ALAR will appear alternating with the last alarm temperature entered. 2 Enter alarm temperature. Press ENTER . IdLE will appear. (Enter 0000 to turn alarm off.) Note: 9999 , as an alarm temperature, automati - cally changes to the maximum temperature rating of your controller. When the alarm sounds, s ...

  • Sentry Industries Sentry 2.0 - page 8

    Chapter 3 Cone-Fire Cone-Fire mode is based on pyrometric cones. It is not designed for heat treating, glass fusing and enameling. For these firings, see “Ramp-Hold,” page 12. Use Ramp-Hold to fire ceramic pieces that require a custom firing schedule, such as some types of stone - ware sculpture or crystalline glaze. Pyrometric Witness Cones Th ...

  • Sentry Industries Sentry 2.0 - page 9

    Low Fire Cones 022 - 011 This range includes decals, over-decorations, lusters, and golds. The firing can be fast. Good venting is important, because oils and other organics burn off. Do not close the lid from the vented position until all odor has disappeared. Low Fire Cones 022 - 011 Firing Schedule Segment Rate Per Hour Time in Segment 1 396°F/ ...

  • Sentry Industries Sentry 2.0 - page 10

    Mirror Test This test will help you de - termine how much Pre-Heat to use. Occasionally during Pre-Heat, hold a mirror near the top peephole. (Be careful to avoid burns.) The mirror must be at room tempera - ture, not hot, so hold it near the peephole for only several seconds. If the mirror fogs, mois - ture is still escaping from the ware. When th ...

  • Sentry Industries Sentry 2.0 - page 11

    Watch the pyrometric witness cones through the peep - hole. Press STOP when the correct witness cone bends, not - ing how much Hold time was needed. Program that much Hold time the next time you fire the same type of ware loaded to the same capacity. Note: During Hold, the display temperature will alternate with time left in Hold. To figure hold ti ...

  • Sentry Industries Sentry 2.0 - page 12

    Chapter 4 Ramp-Hold Definition of a Segment Ramp-Hold fires in segments. Every segment must have a target temperature and a heating rate to reach that temper - ature. Shown in diagram A is a segment with a temperature of 750°. Rate is figured in degrees per hour. In Diagram A above, the temperature takes two hours to reach 750°. The rate is 750 ? ...

  • Sentry Industries Sentry 2.0 - page 13

    User Programs (USER) When you enter Ramp-Hold mode, the first prompt to ap - pear is USER , meaning, “Select one of your programs.” You, the user, can make your own firing schedules and store them in memory. A firing schedule, or program, is the seg - ments needed for a firing. To make a segment, you will need three facts: I rate (how fast temp ...

  • Sentry Industries Sentry 2.0 - page 14

    Firing a Stored User Program To use a stored program, press 4 from IdLE. Enter the program number at the USER prompt. Press ENTER .I f there are no changes to the program, press STOP . IdLE will appear. The controller is ready to fire your selected program. To begin firing, press ENTER once. (Use “Program Re - view,” page 6, before firing. See ...

  • Sentry Industries Sentry 2.0 - page 15

    If you are not using a kiln vent, leave peephole plugs out and vent the lid. Set the alarm to 1000°F. When the alarm sounds, close the lid from venting position. Set the alarm again, this time to 1850° F. When it sounds, check the witness cone through the peephole. When the cone bends to six o’clock, write down the temperature. (Use that temper ...

  • Sentry Industries Sentry 2.0 - page 16

    Chapter 5 Multiple Zone Kilns Note: See also Multiple Zone Options, page 21. An Overview of Multiple Zone Firing If you are not sure how many zones your kiln has, look into the firing chamber. The number of thermocouple tips indi - cates the number of zones. In single-zone kilns, the Sentry measures temperature from one location. When the controlle ...

  • Sentry Industries Sentry 2.0 - page 17

    Chapter 6 Options The Options key gives you access to a list of features. With each press of the Options key, you will see the display code for the next option. 1 When you find the option you want to use, press ENTER . 2 Use the 1 and 2 keys to select changes within the op - tion. 3 After making a selection for an option, press ENTER . The display ...

  • Sentry Industries Sentry 2.0 - page 18

    I Place witness cones in several locations in the kiln. How to Use Cone Offset Cone Offset changes the shut-off point of the cone by the degrees of temperature shown in the chart below. 1 From IdLE , press OPTIONS until OFST appears. 2 Press ENTER . The current Cone Offset adjustment number will appear. 3 Using the 1 and 2 keys, select a new adjust ...

  • Sentry Industries Sentry 2.0 - page 19

    Calibrating Thermocouple Offset With a Digital Pyrometer You can calibrate Thermocouple Offset using a cali - brated digital pyrometer. One way to calibrate your pyrome - ter is to take it to a heat treater or other location that has a cal - ibrated controller you can trust. Take a reading from a furnace with your pyrometer. Either zero it out to m ...

  • Sentry Industries Sentry 2.0 - page 20

    AOP Outlet (AOP) Select Vent Fan or Alarm for the Auxiliary Output The optional “AOP” (Auxiliary Output) is an electrical receptacle mounted in the kiln’s switch box. This outlet can power a kiln vent or an external alarm, such as a bell. The AOP is a special-order option that might not be on your kiln. The choices in the AOP option: I ALAR A ...

  • Sentry Industries Sentry 2.0 - page 21

    Configuration Code (CFG) Information for Technicians From IdLE , press OPTIONS repeatedly until CFG ap - pears. Press ENTER . The factory configuration code will ap - pear. Press ENTER . Press STOP to return to IdLE . The configuration code can be changed only at the factory. Software Version (SOFT) Information for Technicians From IdLE , press OPT ...

  • Sentry Industries Sentry 2.0 - page 22

    Chapter 7 Error Messages I Error messages are accompanied by an alarm. I Non-interrupting messages do not stop the firing. Ter - minating error messages do. I FTC, FTH, LTdE, and HTdE error messages are based upon the setting in the Temperature Deviation (TEdE) option. See page 20. For detailed diagnostics and maintenance, see “Sentry Trouble Sho ...

  • Sentry Industries Sentry 2.0 - page 23

    How the Sentry Handles Power Failures The Sentry handles a power failure in two ways: 1 After a brief power failure, the controller continues firing as before. It shows a normal temperature dis - play alternating with PF . 2 After an extended power failure, PF 2 or PF 3 will appear. The kiln will NOT resume firing. The controller will resume the fi ...

  • Sentry Industries Sentry 2.0 - page 24

    24 Appendix A: Display Messages AbRT Abort 6 The firing was stopped. ALAR Alarm 6, 10, 13 - 15, 20, 22 ALAR appears either when you are entering an alarm tempera - ture or when the alarm is sounding during a firing. To stop an alarm, press any key except STOP. If the alarm goes off when you first begin firing, it is because it was set for a lower t ...

  • Sentry Industries Sentry 2.0 - page 25

    25 IdLE Ready to Begin 5 The Sentry must display the IdLE message before you can begin firing or programming. LId Lid is Open 5 When LId appears, the kiln is equipped with a lid safety switch, and the lid (or door) is open during firing. Or a two-pin connector on the back of the board is missing. LOCK Program Lock 20 With this option activated, a s ...

  • Sentry Industries Sentry 2.0 - page 26

    26 Appendix B: Preset Standard Cone-Fire Schedules - °F These are the firing schedules programmed in Cone-Fire mode. To customize a schedule, write down your changes. Then load your new schedule into Ramp-Hold. Low Fire Cones °F Segment 1 Segment 2 Cone Rate 1 Temp. 1 Rate 2 Temp. 2 022 396 979 108 1087 021 396 1004 108 1112 020 396 1051 108 1159 ...

  • Sentry Industries Sentry 2.0 - page 27

    27 Appendix B: Preset Standard Cone-Fire Schedules - °C These are the firing schedules programmed in Cone-Fire mode. To customize a schedule, write down your changes. Then load your new schedule into Ramp-Hold. Low Fire Cones °C Segment 1 Segment 2 Cone Rate 1 Temp. 1 Rate 2 Temp. 2 022 220 526 60 586 021 220 540 60 600 020 220 566 60 626 019 220 ...

  • Sentry Industries Sentry 2.0 - page 28

    1 Unplug the kiln or disconnect the power. Remove the 4 screws holding the controller faceplate to the switch box. Gently remove the old controller. 2 Disconnect the wires from the old controller. 3 If your kiln is top-load - ing and originally came with a DTC 100 or 600, the heat shield inside the switch box may need to be moved to give more clear ...

  • Sentry Industries Sentry 2.0 - page 29

    29 ...

  • Sentry Industries Sentry 2.0 - page 30

    30 Appendix D: Temperature Equivalents For Orton Self-Supporting Pyrometric Cones °F Cone Self-Supporting Cones Pre-Fire Number Color Heated at: 27° F 108° F 270° F Per Hour* Per Hour* Per Hour* 022 — 1087 1094 Green 021 — 1112 1143 Fuschia 020 — 1159 1180 Orange 019 1213 1252 1283 Yellow 018 1267 1319 1353 White 017 1301 1360 1405 Pink 0 ...

  • Sentry Industries Sentry 2.0 - page 31

    31 Sentry Ramp-Hold Shorthand Instructions After you press the keys in the left column, the message to the right will appear. KEYS TO PRESS DISPLAY COMMENTS PROGRAM AND FIRE THE KILN. Apply power to kiln IdLE Press Enter if IdLE does not appear. 4 USER Enter program number. 1, 2, 3, or 4 1 Program number appears. ENTER RA 1 Enter rate of segment 1. ...

  • Sentry Industries Sentry 2.0 - page 32

    32 Sentry Cone-Fire Shorthand Programming After you press the key(s) in the left column, the message to the right will appear. Press 1 from IdLE .I ft h e 1 key does not re - spond, your controller does not have Cone-Fire. KEYS TO PRESS DISPLAY COMMENTS Apply power to kiln IdLE Press Enter if IdLE doesn’t appear. 1 CONE Enter the cone number . Co ...

Produzent Sentry Industries Kategorie Thermometer

Dokumente, die wir vom Produzenten des Geräts Sentry Industries Sentry 2.0 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Sentry Industries
- Bedienungsanleitungen Sentry 2.0
- Produktkarten Sentry Industries
- Informationsbroschüren
- oder Energieetiketten Sentry Industries Sentry 2.0
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Sentry Industries Sentry 2.0.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Sentry Industries Sentry 2.0, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Sentry Industries Sentry 2.0. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Sentry Industries Sentry 2.0 ansehen.

Die komplette Bedienungsanleitung des Geräts Sentry Industries Sentry 2.0, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Sentry Industries Sentry 2.0 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Sentry Industries Sentry 2.0 verständlich ist.

Eine gänzliche Bedienungsanleitung von Sentry Industries sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Sentry Industries Sentry 2.0 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Sentry Industries Sentry 2.0 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Sentry Industries Sentry 2.0, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Sentry Industries Sentry 2.0 - die uns die ersten Schritte während der Nutzung von Sentry Industries Sentry 2.0 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Sentry Industries Sentry 2.0 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Sentry Industries Sentry 2.0 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Sentry Industries Sentry 2.0?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Sentry Industries Sentry 2.0 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Sentry Industries Sentry 2.0 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)