American Power Conversion AP7862J - page 1
Basic and Meter ed Rack Power D istribution Un it AP7862J AP7562J Installation and Quick -Start Ma nual ...
-
American Power Conversion AP7862J - page 2
This manual is available in English on th e enclosed CD. ...
-
American Power Conversion AP7862J - page 3
Contents Basic an d Metered Ra ck Pow er Distr ibution Unit i Produ ct Description and Invent ory . . . . . . . . . . . . . . . . . . . . . . 1 Descr iption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Additio nal docume ntation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Invento ry . . . . . . . ...
-
American Power Conversion AP7862J - page 4
ii Basic an d Metered Ra ck Pow er Distr ibution Unit Warrant y and Ser vice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Limited w arranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Warrant y limi tations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Obtain ing s ervice . . . . ...
-
American Power Conversion AP7862J - page 5
Basic an d Metered Ra ck Pow er Distr ibution Unit 1 Pr oduct Description and Inventory Description Thi s manual pr ovides in formation on i nstalli ng and oper ating the followi ng three- phase Rack Power Dist ributio n Units ( PDU s): Metered PDU AP7862J: NEMA L21-20 plug 42 NEMA 5-15 outl ets Basic PDU AP7562J: NEMA L21-20 plug 42 NEMA 5-15 outl ...
-
American Power Conversion AP7862J - page 6
Product Descript ion an d Inventory 2 Basic an d Metered Ra ck Pow er Distr ibutio n Unit Additiona l documentatio n The Meter ed Rack P D U User ’ s Guide and the Metered Rack PDU Addendum a re avail able on th e supplied CD or on ou r W eb si te: http://www .apc.com/ . The onlin e user ’ s guide (. Docengusr guide.pdf ) contai ns additi on ...
-
American Power Conversion AP7862J - page 7
Basic an d Metered Ra ck Pow er Distr ibution Unit 3 How to Install the Ba sic and Meter e d PDU Attach the cor d r etention tray s Attac h the cord r etent ion tra ys to the PDU , usin g four flat-he ad screws (provid ed) per tray . Attach cor ds to the tray Attach a cord to the tra y by looping the cord and s ecuring i t to the tray , using a wi ...
-
American Power Conversion AP7862J - page 8
How to Install the Basic and Metered PDU 4 Basic an d Metered Ra ck Pow er Distr ibutio n Unit T oo lless mounting 1. Slide t he mounting pe gs into the holes loca ted in the channel i n the rear pa nel of the enclo sure. 2. S nap t he PDU into plac e by pushing it downwar d until it locks i nto positi on. Note Y ou can mount two PDU s on one side ...
-
American Power Conversion AP7862J - page 9
How to Install the Basic and Metered PDU Basic an d Metered Ra ck Pow er Distr ibution Unit 5 Bracket-mo unting Y ou can or der a rack -mount bracket ki t from APC ( AR8116BLK) . The bracket s attach to the PDU in either of two direc tions, shown in the figure s in step 1. Consider the ori entati on of the PDU in the enclo sure before a t tachin g ...
-
American Power Conversion AP7862J - page 10
How to Install the Basic and Metered PDU 6 Basic an d Metered Ra ck Pow er Distr ibutio n Unit 2. Insert mounting screws (p rovided with the bracket ki t) in the top and bott om positions in t he channel where t he brackets ali gn with the h oles. T ighten the screws t o secure t he PDU to the encl osure. – Recessed orientation – Raised orie nt ...
-
American Power Conversion AP7862J - page 11
Basic an d Metered Ra ck Pow er Distr ibution Unit 7 Operation Disp lay inte rface (AP78 62J only) Link - Rx/Tx 10 / 100 Status Serial Port Rese t Pre ss to sele ct li ne. Pre ss a nd h ol d to in ver t d ispla y . - W ar ning - OK - Overl oad L3 L2 L1 Amps Amps Phase Indicator LED s: • Indicates the phase corr ...
-
American Power Conversion AP7862J - page 12
8 Basic an d Metered Ra ck Pow er Distr ibutio n Unit Quick Configuration for a Meter ed PDU Over v iew Y ou must con figure the f ollowing TCP/IP settings before the PDU can operate on a network: • IP addr ess of the PDU • Subnet mask • De fault g atewa y TCP/IP configuration methods Use one of the following to define the TCP/IP settin gs: ? ...
-
American Power Conversion AP7862J - page 13
Quick Config uration for a Metered PDU Basic an d Metered Ra ck Pow er Distr ibution Unit 9 BOOTP & DHCP configuration The Boot Mode setting, a TCP/IP opt ion in th e PDU ’s Network menu, identi fies how TCP/IP settin gs will be defined. Th e possibl e settings are Manual , DHCP only , BOOTP only , and DHCP & BOOTP (the defaul t setti ng) ...
-
American Power Conversion AP7862J - page 14
Quick Conf igurati on for a Metered PDU 10 Basic an d Metered Ra ck Pow er Distr ibution Unit DHCP . Y ou can use a RFC2 131/RFC2132 -com plian t DHCP server to configur e the TCP/IP se ttings for t he PDU . 1. The PDU sends a DH CP reques t that uses the following to identif y itself : – V endor Cla ss Identi fier ( APC by de faul t) – Client ...
-
American Power Conversion AP7862J - page 15
Quick Config uration for a Metered PDU Basic an d Metered Ra ck Pow er Distr ibution Unit 11 Local access to the contr ol console Y ou can use a local computer to connect to the PDU to access t he control console. 1. Select a serial port a t the local compu t er , and dis able any servic e which uses that port. 2. Use the c onfiguration c able (940 ...
-
American Power Conversion AP7862J - page 16
Quick Conf igurati on for a Metered PDU 12 Basic an d Metered Ra ck Pow er Distr ibution Unit 3. Use T elnet to access the PDU at its newly ass i gned IP a ddress. For example: telnet 156.205.14.141 4. Use apc for bot h User Name and Password. 5. See “Contr ol console” on t his page t o finish the con figurati on. Contr ol console After yo u lo ...
-
American Power Conversion AP7862J - page 17
Basic an d Metered Ra ck Pow er Distr ibution Unit 13 How to Access a Configur ed PDU Over v iew After t he PDU is r unning on your network, you c an use se veral dif ferent interf aces to access the PDU . Br o wser interface As your br owser , use Microsoft ® In ternet Explorer 5.5 (or h ighe r) to configur e PDU options or t o view the Event log ...
-
American Power Conversion AP7862J - page 18
14 Basic an d Metered Ra ck Pow er Distr ibution Unit How to Recover Fr om a Lost Passwor d Y o u can use a lo cal c omp uter that con nect s to t he PDU through t he serial port on t he front panel of the unit. 1. Select a serial port at a local co m pute r , and disabl e any servic e that uses the port. 2. Use the c onfiguration c able (940-01 44 ...
-
American Power Conversion AP7862J - page 19
Basic an d Metered Ra ck Pow er Distr ibution Unit 15 Specifications AP786 2J/AP75 62J Electrical Nominal in put voltage 173 V , 3-phase Acceptable input voltage ± 10 % Nominal input voltage Inpu t fr eque ncy 47 – 63 Hz Input connectors NEMA L21-20 plug Output connecto rs 42 NEMA 5- 15 outlet s Maximum tot al current dr aw 20 A per Phas e Physi ...
-
American Power Conversion AP7862J - page 20
16 Basic an d Metered Ra ck Pow er Distr ibution Unit W arranty and Service Limited war ranty APC warrants the PDU to be free fr om de fec ts in ma teri als an d workmanshi p for a per iod of two years f rom the date of pu rchase. I ts obligat i on und er this wa rranty is limited to repairing or replaci ng, at it s own sole op tion, any such def e ...
-
American Power Conversion AP7862J - page 21
Basic an d Metered Ra ck Pow er Distr ibution Unit 17 Life-Support Policy General po licy American Po wer Conversion ( APC ) does not recommend the use of any of its produ cts in the f ollow ing situat ions: • In lif e-support applications where fa ilure or malfuncti on of the APC product can be reasonably exp ected to c ause failure o f the life ...
-
American Power Conversion AP7862J - page 22
...
-
American Power Conversion AP7862J - page 23
Radio Fr equency Interfer ence This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inte rference when the equipment is operated in a commercial environment. This equipment generates, uses, and ...
-
American Power Conversion AP7862J - page 24
APC W orldwide Customer Support Customer s upport for this or any other APC product is avai lable at no char ge in any of the following ways : • V isit th e APC W eb site t o find answers to fr equently asked ques tions ( FA Q s), to acces s documents in the APC Knowledge Ba se, and to s ubmit customer sup port reque sts. – www .apc.com ( Corpo ...
Haben Sie eine Frage bezüglich American Power Conversion AP7862J?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit American Power Conversion AP7862J nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit American Power Conversion AP7862J hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.