Bedienungsanleitung Carrier PTACSTAT-NP-HC

32 Seiten 0.52 mb
Download

Zur Seite of 32

Summary
  • Carrier PTACSTAT-NP-HC - page 1

    P T A C S T A T --- N P --- H C , P T A C S T A T --- N P --- H P Installat ion Inst ructio ns Oper ating Manual A07050 Non - - - Programmable T hermostat NOTE : Read the en tire in structio n man ual b efo re startin g th e in stallatio n. ...

  • Carrier PTACSTAT-NP-HC - page 2

    2 ...

  • Carrier PTACSTAT-NP-HC - page 3

    3 T ABLE OF CON TENTS P AGE SAFETY CONSIDERA TIONS 3 .................................... INTRODUCTI ON 4 .............................................. INST ALLA TION CONSIDERA TIONS 4 .............................. INST ALLA TION 5 ............................................... Step 1 — T herm o stat Locatio n 5 ............................... ...

  • Carrier PTACSTAT-NP-HC - page 4

    4 sign ifies a h azard wh ich co u ld resu lt in perso nal in ju ry or death . CAUTION is use d t o ide nti f y unsa fe pra ct ic e s whi c h m ay r e sul t in mi nor pe r sona l i njur y or produc t a nd prope r ty da ma ge. NOTE i s us e d to hi ghli ght s ugge st ions whic h wi ll result in enh an ced installatio n , reliability, or o peratio n ...

  • Carrier PTACSTAT-NP-HC - page 5

    5 Bat teries Battery o p eration is availab le for installation s where there is n o co mmo n (C) wir e a vai l abl e at t he the r mos ta t. For bat t er y oper a ti on, ins ta ll t wo alka l ine AA bat t er ie s . The the rmos t at is desi gne d to ope ra t e up t o one year on a se t of batteries. A battery in d icator on th e disp lay w arns wh ...

  • Carrier PTACSTAT-NP-HC - page 6

    6 Ther mos ta t s hould NOT be mounte d S Clos e to a window , on a n outs ide wal l , or next to a door le a ding t o the outs i de. S Expose d to dir ec t l ight or he at f r om the s un, a la mp, f ir epl ace, or o th er temp eratu re - - rad iatin g o b jects wh ich co u ld cau se a false read in g . S Clos e to or in dir ec t ai r fl ow from t ...

  • Carrier PTACSTAT-NP-HC - page 7

    7 ENVIRONMENT AL HAZARD Failu re to fo llow this cautio n may resu lt in en viro n men tal dam age . Mercu ry is a hazar dous wast e . Fede ra l re gula t ions r equi r e t ha t Me rc ur y be di spos e d of pr ope rl y . CAUTION ! 3. Ope n the rmos t at ( mounti ng ba se ) to e xpos e mounti ng hol es . The ba s e ca n be re moved to simpl i fy mou ...

  • Carrier PTACSTAT-NP-HC - page 8

    8 5. Drill two 3 /16 - - in . mo un tin g ho les in wall where mark ed. 6. Secur e mount ing ba s e t o wa ll with 2 a nc hors a nd sc re ws provi de d (a ddi ti onal anc hori ng hol es ava i la ble f or more s ec ur e m ounti ng, if nee de d) m aki ng sur e al l wi r es ext e nd thr ough hole in m ounti ng bas e . 7. Ad ju st leng th and ro u tin ...

  • Carrier PTACSTAT-NP-HC - page 9

    9 R W Y O Gh Gl C C Gl Gh O Y W R Rc - 24 VAC, from cooling equipment Rh - 24 V AC , from heating equipment W - Hea ting C - Common 24 V A C G - Fan Y - Cooling O/B reversing valve Not used OR OR or PT AC T erminal Designations Thermostat T erminal Designations A08092 Fig. 3 - - T er minal D es ignat ions ...

  • Carrier PTACSTAT-NP-HC - page 10

    10 ELECTRICAL OPERA TION HAZARD Failu re to follo w this cautio n m ay result in eq u ip men t dam age or im prope r oper a ti on. Imp ro per wirin g or installatio n m ay dam age the therm ostat. Ch eck to mak e sure wirin g is correct before pro ceed in g with installatio n o r turnin g o n u nit. CAUTION ! 9. Pu sh an y ex cess wire into w all a ...

  • Carrier PTACSTAT-NP-HC - page 11

    11 11. Cl ose ther mos ta t as s embl y ma king s ur e pi ns on bac k of ci rc ui t boar d align w ith so ckets in con n ecto r . 12. Tur n ON powe r t o unit . Whe n powe r i s a ppl ie d, al l di s pla y icons ar e l it for 2 s ec onds to t e st t he di s pla y . Foll owi ng this , t he equi pme nt type f or whic h t he the rm ost at is conf i gu ...

  • Carrier PTACSTAT-NP-HC - page 12

    12 Opti on 17 - - Ti me bet we en e quipm ent st a ges (HP only) Opti on 18 - - Conti nuous ba c kli ghti ng ( when 24V AC is suppli ed onl y) Op tio n 26 - - Minim u m coo lin g setpo in t Op tio n 27 - - Max imu m heatin g setp o int Opti on 39 - - Dis pla y s et poi nt onl y (or se t point and r oom a ir ) Op tio n 99 - - Reset to factory d efau ...

  • Carrier PTACSTAT-NP-HC - page 13

    13 Mean in gs: PC or P H selects PT AC u n its (P ackag ed T erm inal Air C on d itio ners). PH c ontr ols a PT AC wi th 1 s pe ed he at pump with 1 s t age of a ux he at . PC c ontr ols a PT AC wi th 1 s pee d a ir condi ti one r wi th 1 s t age of E1 he a t. NOTE : A PH ther mos ta t c an be conve r te d to contr ol a He at Cool s yst em . Opt io ...

  • Carrier PTACSTAT-NP-HC - page 14

    14 Opti on 1 1 - - Mi nimum Deadband Be twe e n Heat ing And Cool ing Selectio n s: 01 thr ough 06 — De f aul t i s 02. Sets th e min im um allo wab le n u mb er o f deg rees b etween h eatin g and co o ling setpo in ts. O ne setp o in t will “p u sh ” the o th er to main tain th is d ifference. Opt ion 13 - - Room Ai r T em per atur e Off s ...

  • Carrier PTACSTAT-NP-HC - page 15

    15 Opti on 17 - - Mi nim um T ime Bet we en Equi pme nt St ages (H P only) Selectio n s: 10, 15, 20, 25 minut es — De f aul t is 15. Whe n ther e a re t wo sta ge s of hea t ava ila ble , thi s i s the am ount of t im e the fi r st st a ge must ope r at e be for e the s e cond st age c a n turn on. Wi th hea t pumps, longe r ti me s ca n re duce ...

  • Carrier PTACSTAT-NP-HC - page 16

    16 Opti on 39 - - Dis pl ay Set poi nt Only or Set point and Room T empe r atur e This confi gura t ion opt ion de t er mi nes what t he dis pla y on the ther mos ta t wil l loo k lik e. Selectio n s: SP — Wi ll di spl a y the s et point onl y . rt — W ill di spl a y the se t point a nd room ai r te mpe ra t ure Def aul t = SP Op tio n 99 - - R ...

  • Carrier PTACSTAT-NP-HC - page 17

    17 T o enter the In staller T est mo de, u se th e same p ro cess as is u sed to en ter In staller Confi gura t ion, onl y hold the F AN ke y longer . More spe c if ic a ll y , pres s and hold the F AN for about 15 s ec onds unt il the di spl a y re ads I n on the l e ft a nd S in the sm al le r di spl ay . The MOD E wil l be OFF . The MODE key (up ...

  • Carrier PTACSTAT-NP-HC - page 18

    18 OPERA TING THE THERMOST A T NOTE : Should t he t he rmos t at los e pow er , i t wi ll tur n ba ck on wi t h the la st se t ti ngs pri or t o the powe r outa ge . But ton I den tificat ion A08088 Fig . 5 - - B u tton Iden tificatio n a - - F AN Sel ec t s whet he r the f an ope ra te s c onti nuousl y (on) or i n cycl e mode (a ut o) b - - MODE ...

  • Carrier PTACSTAT-NP-HC - page 19

    19 Dis play b ack light ing The dis pl ay has t wo le vel s of light ing, hi gh le vel a nd cont inuous l ow leve l. Hi gh le ve l li ght ing c ome s on for 1 0 se c onds any ti me a but ton is pr e ss e d. Conti nuous low l e vel light ing i s onl y a vai la bl e i f the t her mos ta t i s ope ra te d f rom 24V AC. It is not a va il abl e wi th ba ...

  • Carrier PTACSTAT-NP-HC - page 20

    20 4 Ther mos ta t mode i s Cool 5 Ther mos ta t mode i s He at 6 Ther mos ta t mode i s em er genc y heat 7 Fahr e nhei t 8C e l s i u s 9 Ba tt er y s tr engt h indi c at or 10 Aux Heat is On 11 Co mp resso r is On (if flashin g , it is waitin g to com e on ) 12 Cur re nt s e tpoi nt ( i f c onfi gur ed t o dis pla y r oom te mp) Set ti ng the te ...

  • Carrier PTACSTAT-NP-HC - page 21

    21 duri ng your he ati ng and c ool ing c yc le s ( a uto mode , s ome ti me s know n as cycl e mode ). Th e therm ostat is set at the factory to ru n au to matically as need ed (au to ). H ere’ s ho w to ch ang e the setting so it run s conti nuously . 1. Pres s t he fa n button on the le ft . The di spl ay me ss a ge wil l cha nge fr om a u t o ...

  • Carrier PTACSTAT-NP-HC - page 22

    22 T wo AA ba tt e ri es s houl d l as t about one yea r . Whe n the batt e ri es ha ve los t about one- - thi rd of the ir powe r , a batt er y ic on appe a rs on t he dis pla y ( two- - thi rds of it wil l be bla ck). As t he ba tt er ie s ge t wea ke r , t he ic on goes down to one bl ac k bar and t he n none. When t he icon is empt y , you wi l ...

  • Carrier PTACSTAT-NP-HC - page 23

    23 TROUBL E SHOOTIN G YOUR THERMOST A T What if... The batt e ry ic on is dis playe d The bat te r y ic on a ppea r s on the di spl ay onl y when t he bat te r y st ar t s to l ose powe r . Repl ac e i t when one- - thi rd of the i con is bl ac k. If your the rmos t at i s bat t er y powe re d a nd you wai t unt i l t he i c on is j ust a si lhoue ...

  • Carrier PTACSTAT-NP-HC - page 24

    24 Th ere are icons fla sh ing on th e th ermo sta t d ispla y Ther e a re s e ver al i nte r nal t im er s whi ch inf lue nc e the the rmos t at ’ s oper a ti on. If a ti me r i s pre vent ing t he equipm ent fr om t urni ng on, the di s pla y ic ons whi ch s how the e qui pment i s oper a ti ng, wil l be f la shi ng to indic a te a t urn- - on ...

  • Carrier PTACSTAT-NP-HC - page 25

    25 THERMOST A T LIMITED W ARRANTY FO R W ARRANT Y SERVICE OR REP AIR, YO U MUST FOLLO W THESE STEPS IN ORDER: FIR S T : Co n tact th e installer. SECOND: Cont a ct t he nea re st di st ri butor . (Se e te le phone yel low pa ges .) THIRD : Conta ct : Car ri e r Corpor at ion PT AC Consume r Rel a ti ons P .O. Box 4808 Syra c use , Ne w Y ork 13221 ...

  • Carrier PTACSTAT-NP-HC - page 26

    26 LIMIT ED W ARRANTY for THERM OST A T Car r ie r Corpor at i on (he re i naf te r “ Company” ) wa rr a nts t his pr oduc t a ga ins t fa i lur e due to def e ct in mat er i al and workma ns hip unde r norma l use and main tenan ce as fo llow s. If a part fails du e to defect w ith in five (5 ) years fro m the dat e of pur cha s e, Compa ny wi ...

  • Carrier PTACSTAT-NP-HC - page 27

    27 5. If the da te of ori gina l pur cha se ca nnot be ver if ie d, the n the wa rr a nty per i od begins ni ne ty (90) da ys fr om the da te of pr oduct ma nuf ac t ure (a s indi c at ed by t he model and s e ri al number) . LIMI T A TIONS OF W ARRANTIES: ALL I MPLIED W ARRANTIES AND/ OR CONDITI ONS (IN CLUDING IM PLIED W ARRANTIES OR CONDITI ONS ...

  • Carrier PTACSTAT-NP-HC - page 28

    28 6. Failu re to start d u e to voltag e con d ition s, blo wn fu ses, op en circuit bre a ker s , or da ma ges due t o the ina de quac y or int er r upti on of ele c tr ic a l service. 7. Dama ge as a re sul t of floods , wi nds, fi re s , li ghtni ng, accid en ts, co rrosiv e envi r onment s or ot her c ondit i ons beyond the c ont rol of Compa ...

  • Carrier PTACSTAT-NP-HC - page 29

    29 T ab le 1 sho ws th e th ermo stat ou tp ut s for each availab le stage o f heatin g o r cool i ng. It ma y be use ful i n che ckout or t r ouble shoot i ng. T a ble 1 – Output s EQUI P MEN T CONFIGU RA TION OPTION #1 COOL ST AGE 1 HEA T ST AGE 1 HEA T ST AGE 2 EM HEAT PC Y, G W --- --- --- --- PH RVS = C (O ) Y, G , O / B Y, G Y, G , W W PH R ...

  • Carrier PTACSTAT-NP-HC - page 30

    30 WIRING DIAG RAMS GL or GH G R Rc Rh Y W W CC O M 52MPT AC or Thermostat A08096 Fig. 7 - - A/C Ther mos tat T ypic al Ins tal lat i on GL or GH O/B O Thermostat 52MPT AC W W Y Y G Rh Rc R C COM or Reversing Valve Heat Cool Fan 24V AC Heating 24V AC Cooling Common A08097 Fig. 8 - - HP Ther most at T ypic al Ins tal lat i on ...

  • Carrier PTACSTAT-NP-HC - page 31

    31 THERMOST A T CONFIGURA TION RECORD Config uration Optio ns Op tion 01 ____ Equ ipm ent T ype Op tion 03 ____ Fah re nh eit/Cen tigr ade Sele ction Op tion 04 ____ Unu se d for PT AC Op tion 07 ____ Unu se d for PT AC Op tion 10 ____ Rever sin g V alve Op tion 11 ____ Minim um Deadban d Betwe en Heat ing and Coolin g Setp oints Op tion 13 ____ Ro ...

  • Carrier PTACSTAT-NP-HC - page 32

    32 Copyright 2008 Carrier Corp. S 7310 W . Morris St . S Indianapolis, I N 46231 Printed i n U.S.A. Editi on Da te: 0 3/0 8 Manufacturer r eserves the right to change, at any time, specifications and de signs without no tice and witho ut oblig ations. C a t a l o g N o : P T A C S T A T --- N P --- 0 1 S I Replaces : NEW ...

Produzent Carrier Kategorie Thermostat

Dokumente, die wir vom Produzenten des Geräts Carrier PTACSTAT-NP-HC erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Carrier
- Bedienungsanleitungen PTACSTAT-NP-HC
- Produktkarten Carrier
- Informationsbroschüren
- oder Energieetiketten Carrier PTACSTAT-NP-HC
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Carrier PTACSTAT-NP-HC.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Carrier PTACSTAT-NP-HC, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Carrier PTACSTAT-NP-HC. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Carrier PTACSTAT-NP-HC ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Carrier PTACSTAT-NP-HC, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Carrier PTACSTAT-NP-HC hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Carrier PTACSTAT-NP-HC verständlich ist.

Eine gänzliche Bedienungsanleitung von Carrier sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Carrier PTACSTAT-NP-HC bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Carrier PTACSTAT-NP-HC befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Carrier PTACSTAT-NP-HC, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Carrier PTACSTAT-NP-HC - die uns die ersten Schritte während der Nutzung von Carrier PTACSTAT-NP-HC erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Carrier PTACSTAT-NP-HC hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Carrier PTACSTAT-NP-HC im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Carrier PTACSTAT-NP-HC?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Carrier PTACSTAT-NP-HC nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Carrier PTACSTAT-NP-HC hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)