  • SMC Networks SMCRPU14 - page 1

    Redundant Po wer Unit F ault-tolerant networking! • Supports up to four sw itch units • A C lin e draws po wer from dif ferent supply circuit • DC line pro vides backup po wer to attached de vices • Thermal ove rload protectio n • Over -volt age protection for each outp ut channel • Over -current pr otection can shut down the RPU • Sh ...

  • SMC Networks SMCRPU14 - page 2

    ...

  • SMC Networks SMCRPU14 - page 3

    38 T esla Irvine, CA 9261 8 Phone: (9 49) 67 9-8000 Redundant P ower Unit User Guide Po wers u p to four SMC networking de vices Janurary 2005 Pub. # 150200 050500A R0 1 ...

  • SMC Networks SMCRPU14 - page 4

    Information fu rnished by SM C Netw orks , Inc . (SM C) is bel ieve d to be ac curate a nd reliab le. H owev er , no respon sibility is assumed by SMC fo r its use, nor fo r any infrin gemen ts of pate nts or othe r rights of th ird par ties whic h may re sul t fro m its u se. No l ice nse i s g rant ed by i mpli catio n or othe rwise unde r any pa ...

  • SMC Networks SMCRPU14 - page 5

    i L IMITED W ARRA NTY Limited W ar ranty Statement: SM C Networks, Inc. (“SMC ”) warr ants it s product s to be free from defect s in wor kmanship and materials , under normal use and ser vice, for the applicable wa r ranty term . All SMC products carry a standard 90-day limited warranty from the date of purc hase from SMC or its Authorized R e ...

  • SMC Networks SMCRPU14 - page 6

    L IMIT ED W AR RANTY ii WARRA NTIE S EXCLUSIV E: IF AN SMC PRODUCT DOES NOT OPERA TE AS W ARRANTED ABO VE, CUSTOMER’ S SOLE REMED Y SHALL BE REP AIR OR REPLA CEMENT OF THE PRODUCT I N QUESTION , AT SMC’S OPTION . THE FOREGOING W ARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER W ARRANTIES OR CONDITIONS , EXPRESS OR IMPLIED , EI ...

  • SMC Networks SMCRPU14 - page 7

    C OMPLIANCES iii C OMPLIANCES FCC - C lass B This e quipment has been tested and found to comply wit h the limi ts for a Class B d igital d evice, pursuant t o P ar t 15 of the FCC Rules. These li mits are de signed to provide reas onable pro tecti on again st harmful interf eren ce in a re sid entia l insta llati on. This equ ipm ent gene rate s , ...

  • SMC Networks SMCRPU14 - page 8

    C OMPLIANCES iv EC Confor mance Declaration - Class B SMC contact f or these pr oducts in E urope is: SMC Networks Europe, Edifici o Conata II, Ca lle F ructuó s Gela bert 6-8, 2 o , 4 a , 08970 - Sant Joan Despí, Barcelona , Spain. This i nfor mation techno log y equipment complies wi th the requir ements of the Council Dire ctive 89/336 /EEC on ...

  • SMC Networks SMCRPU14 - page 9

    C OMPLIANCES v Australia A S/NZS 3548 (1995) - Clas s B SMC contact f or product s in Australi a is: SMC Communication s Pty . Ltd. Suite 18, 12 T r yon Road, Lind field NSW 2070, Phon e: 61-2-9 4160437 F ax: 61-2-9 41604 74 Ple ase rea d th e foll ow ing s afety infor mati on ca refully before in stalling the RPU: WAR N IN G : Installation and rem ...

  • SMC Networks SMCRPU14 - page 10

    C OMPLIANCES vi F rance and Peru only This unit cannot be po wered from IT † supplies . If your supplies are of IT type, this unit must be powered by 230 V (2P +T) via an isolation transfor mer ratio 1:1, with the secondary con- nection point labelled Neutral, connected directly to earth (g round). † Impéd ance à l a terre V euillez lire à f ...

  • SMC Networks SMCRPU14 - page 11

    C OMPLIANCES vii • Vous d evez raccor der ce groupe à un e sortie m ise à la t erre (mi se à la masse) afin de respecter les normes internatio nales de sécurité. • Le coupl eur d’a ppareil ( le connec teur du g roupe et non pas la pris e murale) doit r especter une config uratio n qui perm et un br anchement sur une entrée d’appa reil ...

  • SMC Networks SMCRPU14 - page 12

    C OMPLIANCES viii Bitte unbedingt vor dem Einbauen des RPU die folgenden Sich erheitsanweisungen durchlesen: WAR N UN G: Die Installation u nd der A usbau de s Geräts darf nu r durch Fachperson al erf olge n. • Diese An leitung ist fr die Benutzung d urch Netzwerkadministrato ren vorges ehen , die fr die Inst allat ion und das eins tellen v on N ...

  • SMC Networks SMCRPU14 - page 13

    C OMPLIANCES ix W ar nin gs and Cautionar y Messa ges Wa r n i n g s (in German) Warni ng: This product does not cont ain any serviceable u ser parts. Warni ng: Installation and removal of the unit must be carr ied out by qualified personnel onl y. Warni ng: When connecting this device to a power ou tlet, connect t he field ground lead on the tri-p ...

  • SMC Networks SMCRPU14 - page 14

    x En vironmental Statem ent The manufact urer of this product ende av ours to sus tain an envi ronmentall y-friend ly policy throughout the enti re producti on proces s . Th is is achieved tho ugh the fol lowing means : • Adherence to national legi slation and regulations on envi ronmental production standards. • Conservation of oper ational re ...

  • SMC Networks SMCRPU14 - page 15

    ix T ABLE OF C ONTENTS 1 About the Redundant Po wer Unit . . . . . . . . . . . . . . . . 1 -1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Features a nd Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Front and Rea r Panels . . . . . . . ...

  • SMC Networks SMCRPU14 - page 16

    T ABLE OF C ONTENTS x ...

  • SMC Networks SMCRPU14 - page 17

    1-1 C HAPTER 1: A BOUT THE R EDUNDANT P OWER U NIT Overview This Redundant P ower Unit (SMCRPU14) can supply 600 W atts of backup pow er to four s witches in the ev ent of an A C loss or failure of an internal power supp ly . Featur es and Benefit s • Supports four switch units w ith 12 VDC supply of up to 150 W. • Indicato r LEDs lo cated on t ...

  • SMC Networks SMCRPU14 - page 18

    1-2 • Shor t-cir cuit protecti on prev ents the RPU f rom being d amag ed from a short cir cuit on any outp ut chann el. • The RP U will op erate und er a no- load condit ion. Front and Re ar Panels F our status indic ators Link, Ac tivity , Fan, Ther mal, and P ower indicators are locat ed on the RP U’ s fron t panel. Wh ile the A C supply a ...

  • SMC Networks SMCRPU14 - page 19

    1-3 Tabl e 1-1 Por t Sta tus L EDs LED (1-4 ) Condition Status Link Off The port does not have a valid connection to a switch. On Yellow The port has a valid conne ction to a switc h. Flashing Yellow There has been an RPU internal power failure. Activity Off The port is not providing power to the connected switch. Flashing Green The port has been s ...

  • SMC Networks SMCRPU14 - page 20

    1-4 ...

  • SMC Networks SMCRPU14 - page 21

    2-1 C HAPTER 2: I NSTALLING THE R EDUNDANT P OWER U NIT Installa tion Th e RPU may be placed on a de sktop or mo unted in a rack. Caution: DO NO T pla ce the R PU on th e f loor a s the case is not waterproof. It is re commended th at this RPU be installed in a network equ ipme nt rack. Selecting a Site RPU un its can b e mou nted in a stan dard 1 ...

  • SMC Networks SMCRPU14 - page 22

    2-2 - Make sure that a separa t e groun ded powe r outlet that provide s 100 to 240 VAC, 50-60 Hz, is within 2 m (6.56 feet) of each device and i s powered fr om an in dependent circuit breaker. A s with any equipmen t, usin g a filt er or surg e suppr essor is recommend ed. Equipm ent Checkl ist After un pack ing the RPU , che ck th e conten ts to ...

  • SMC Networks SMCRPU14 - page 23

    2-3 Mountin g RPU un its can b e mou nted in a stan dard 1 9-inch eq uipmen t rack or on a deskt op or s helf . Mount ing ins tr uctio ns for e ach type of sit e follo w . Rack Mounting Before rack m ounti ng the unit , pay p artic ular attenti on t o the following factors: • Temperat ure: Si nce the tem peratur e within a rack assembly may be hi ...

  • SMC Networks SMCRPU14 - page 24

    2-4 T o ra ck-mount de vices: 1. Attac h the brack ets to the d evice using th e screws pr ovided in th e Bracket Mounting K it. Figure 2-1 Attaching the Brackets 2. Mount th e device in the r ack, using four rack-mount ing screws (not provided ). Figure 2-2 Installing the RPU in a Rack 3. If also installing RPUs , m ount them in the rack below the ...

  • SMC Networks SMCRPU14 - page 25

    2-5 Montage (Rack Mounti ng - Ger man) SMCRPU14 RPU- Einheiten kön nen an ein standardmäßiges 19-Zoll Einrichtungs rack, einen Arbeitstisc h oder ein R e gal montiert werden. F olg end finden Sie di e Montageanweisungen für jeden P ositionstyp . Rac k- Mon tage Beachten Sie die folgenden Faktoren, bev or Sie die Rack-Montage beginnen: • Tempe ...

  • SMC Networks SMCRPU14 - page 26

    2-6 Desktop or Shelf Mounting 1. Attach the fou r adhesive feet to the bot tom of the first RP U unit. Figure 2-3 Attaching the Adhesive Feet 2. Set the device on a flat s urface near an A C pow er source , making sure there a re at le ast fiv e centimeters or tw o inc hes of space on all si des for prope r air f low . Conne cting Switch es to the ...

  • SMC Networks SMCRPU14 - page 27

    2-7 Figure 2-4 Power Receptacle 2. Co nnec t one end of a DC co rd to the re dundant power rece pt acle o n the s uppor ted switch a nd th e other end to an availab le rece pt acle o n the RPU . 3. R epeat steps 1 and 2 for co nnecting up to four sup ported switc hes to the RPU . 4. Connect o ne end o f the A C cord to the A C receptacle on the RPU ...

  • SMC Networks SMCRPU14 - page 28

    2-8 Figure 2-5 Connecting the RPU in a Stack Note: For Internat ional use, you may need to change the AC line cord. Y ou must use a line cord set that has been approved for the receptacle type in y our country . RPU output por t Stack RPU input port AC Power Supply No.1 AC Power Supply No.2 RPU Unit 100-240V,50-60Hz 8A ...

  • SMC Networks SMCRPU14 - page 29

    A-1 A PPENDIX A T ROUBLESHOOTING Diagnosi ng RPU Indicat ors Table A-1 Troubleshoot ing Chart Symptom Action Power LED is Off • Internal power supply is disconnected. • Check connections bet ween the RPU, the power cord, and th e wal l ou tlet. • Contact Technical Support. Link LED is Off • The port does not have a valid connection t o a sw ...

  • SMC Networks SMCRPU14 - page 30

    A-2 Power and Cooling Problems If the PWR LED does not tur n o n when the p ow er c ord is p lug g ed in, you may ha ve a probl em with the po wer outlet, pow er cord , or in ternal pow er supply . However , if the unit powers off after r unning for a w hile, c heck for loose p ow er connection s , po wer l osses or surges at t he po wer o utlet, a ...

  • SMC Networks SMCRPU14 - page 31

    B-1 A PPENDIX B. S PECIFICATIONS Physical Chara cteristics Por ts 4 RPU DC power outlets (IEC socket 216C743-07) LEDs P or t: Link, Activity System: P ower , Fan, Therm al We i g h t 5.5 kg (12.1 lbs) Size 44.0 x 32.3 x 4.3 cm (17.34 x 12.6 x 1.69 in.) Te m p e r a t u r e Operating: 0 to 45 ° C (32 to 110 ° F) Storage: -40 to 70 ° C (- 40 to 15 ...

  • SMC Networks SMCRPU14 - page 32

    B-2 Po wer Supply Internal, auto-r anging transform er: 100 to 240 V AC , 50 to 60 Hz Output 11.5 VDC Po wer Consumption 644 W (Maximum) 161 W (Maximum per por t) Maximu m Cur rent 7.8 A @ 110 V AC 3.5 A @ 240 V A C Overload Protec tion P or ts are s hutdown w hen ou tput exceed s 150 W Po wer Supply +12 VDC Initial acc uracy: +/ - 1% Current: 2 A ...

  • SMC Networks SMCRPU14 - page 33

    B-3 Safety CSA/ C U S (CSA 60950 -00 & UL609 50) CB: IEC 60950 EN 60950 (TÜV /GS) ...

  • SMC Networks SMCRPU14 - page 34

    B-4 ...

  • SMC Networks SMCRPU14 - page 35

    I NDEX - 1 A adhesive feet, attaching 2-6 air flow requirements 2-1 B brackets, attaching 2-4 C CE Mar k 0-iv compliances 0-i ii EMC B-2 safety B-3 contents of pac kage 2-2 cooling pro blems A-2 cord sets, international 2-8 D desktop mou nting 2-6 E EC conformanc e 0-iv EMC/safety c ompliance 0-iii equipment check list 2-2 F front panel of RPU 1-2 ...

  • SMC Networks SMCRPU14 - page 36

    I NDE X I NDEX -2 specificat ions compliances B-2 environmental B- 1 physical B -1 power B-2 standard s compliance B-2 IEEE B-2 standards compli ance 0-iii surge suppress or, using 2-2 T temperature within a rack 2-3 troublesh ooting in-band acce ss A-2 power and cool ing problems A-2 RPU indicators A-1 ...

  • SMC Networks SMCRPU14 - page 37

    ...

  • SMC Networks SMCRPU14 - page 38

    38 T esla Irvine, C A 9261 8 Phone: (949 ) 679-8000 FOR TECHNICAL SUPPOR T , CALL: From U.S.A. an d Canada (2 4 hours a day , 7 days a week) (800) SMC-4-YOU; (94 9) 679-8000; Fax: (949) 679-1481 From E urope (8:00 AM - 5:30 PM UK Time) 44 (0) 118 974 870 0; Fax: 44 (0) 118 974 87 01 INTERNET E-mail a ddresses: techsupp ort@smc.c om europea n.techsu ...

Produzent SMC Networks Kategorie Power Supply

Dokumente, die wir vom Produzenten des Geräts SMC Networks SMCRPU14 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen SMC Networks
- Bedienungsanleitungen SMCRPU14
- Produktkarten SMC Networks
- Informationsbroschüren
- oder Energieetiketten SMC Networks SMCRPU14
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung SMC Networks SMCRPU14.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen SMC Networks SMCRPU14, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen SMC Networks SMCRPU14. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts SMC Networks SMCRPU14 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts SMC Networks SMCRPU14, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von SMC Networks SMCRPU14 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von SMC Networks SMCRPU14 verständlich ist.

Eine gänzliche Bedienungsanleitung von SMC Networks sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von SMC Networks SMCRPU14 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von SMC Networks SMCRPU14 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich SMC Networks SMCRPU14, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts SMC Networks SMCRPU14 - die uns die ersten Schritte während der Nutzung von SMC Networks SMCRPU14 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit SMC Networks SMCRPU14 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von SMC Networks SMCRPU14 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich SMC Networks SMCRPU14?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit SMC Networks SMCRPU14 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit SMC Networks SMCRPU14 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen