    Installation & User Guide Models: R231-13 / R231-14 / R231-15 / R231-16 / R231-17 / R231-1J / R231-1X / R231-1Y / R231-47 / R231-49 / R231-51 / R231-53 / R231-55 / R231-57 / R231-59 / R231-61 R ADIANCE A CCESS L INE C ARDS RX LK FX S M LK RX 100 BASE RX LK FX RX LK T X 100 BASE RX LK FX S M RX LK T X 100 BASE T X T X MAN FD PWR MAN FD PWR MAN F ...

  • METRObility Optical Systems RADIANCE R231-13 - page 2

    This publication is protected by the copyright laws of the United States and other countries, with all rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic, mechanical, chemical, optical or oth ...

  • METRObility Optical Systems RADIANCE R231-13 - page 3

    T able of Contents Radiance Access Line Cards Installation & User Guide Overview .............................................................................................................. 4 Installation Guide ............................................................................................... 6 STEP 1: Unpack the Line Cards ..... ...

  • METRObility Optical Systems RADIANCE R231-13 - page 4

    4 Overview Overview The Metrobility ® Radiance 100Mbps Access Line Cards ar e the industry’ s first media converters with the ability to reach across a wide area network (W AN) to communicate, test and reconfigure an unmanaged remote device, without reducing the available bandwidth to the customer site. This capability is accomplished through th ...

  • METRObility Optical Systems RADIANCE R231-13 - page 5

    Radiance Access Line Cards 5 The Radiance access line card provides the following key features: • Remote management using Metrobility’ s unique Radiance technology which enables communication with an unmanaged remote device. • Complete Remote Monitoring (RMON) Group 1 Ethernet Statistics support. • Remote link testing capability that does n ...

  • METRObility Optical Systems RADIANCE R231-13 - page 6

    6 Installation Guide Installation Guide Follow the simple steps outlined in this section to install and start using the Radiance access line cards. NOTE: Electr ostatic dischar ge pr ecautions should be taken when handling any line car d. Pr oper gr ounding is r ecommended (i.e., wear a wrist strap). Unpack the Line Cards Y our order has been provi ...

  • METRObility Optical Systems RADIANCE R231-13 - page 7

    Radiance Access Line Cards 7 * DIP switches can also be managed via console commands or through Metrobility’ s NetBeacon or WebBeacon management software. Refer to the Command Line Interface Reference Guide , NetBeacon Element Management Software Installation & User Guide or WebBeacon Management Software Installation & User Guide for soft ...

  • METRObility Optical Systems RADIANCE R231-13 - page 8

    8 Installation Guide Link Loss Carry Forward Link Loss Carry Forward (LLCF) is provided as an aid in troubleshoot- ing a remote connection. When LLCF is enabled, loss of the receive signal at the TX port prevents the FX port from transmitting an idle signal onto the cable. Conversely , if the FX port does not detect a receive signal, the TX port do ...

  • METRObility Optical Systems RADIANCE R231-13 - page 9

    Radiance Access Line Cards 9 • Grasp the card by the front panel as shown. • Insert the card into a slot in the chassis making sure that the top and bottom edges of the board are aligned with the top and bottom card guides in the chassis. Do not force the card into the chassis unneces- sarily . It should slide in easily and evenly . FX PWR RX R ...

  • METRObility Optical Systems RADIANCE R231-13 - page 10

    10 Installation Guide • Slide the card in until the top and bottom edges of the front panel are flush and even with the top and bottom edges of the chassis. • T o secure the line card to the chassis, turn the thumbscrew clockwise until it is snug. The card is now properly installed and ready for connection to the network. • It is not necessar ...

  • METRObility Optical Systems RADIANCE R231-13 - page 11

    Radiance Access Line Cards 11 The singlemode (SM) connector supports a maximum segment length of 20, 40, 60, or 100 km, depending on the model. NOTE: T o enable remote management, make sure the management (MAN) LED is ON after connecting the fiber cable to the remote access line card. If not, reset one of the access line cards via software or a pow ...

  • METRObility Optical Systems RADIANCE R231-13 - page 12

    12 User Guide User Guide This section contains information about the operating featur es of the Radiance access line cards. LED Indicators The Radiance access line cards provide several LEDs on the front panel for the visible verification of unit status and proper functionality . These LEDs can help with troubleshooting and overall network diagnosi ...

  • METRObility Optical Systems RADIANCE R231-13 - page 13

    Radiance Access Line Cards 13 Default Software Settings The following settings can only be changed via software commands. * Bandwidth Allocation .............................................................................. 100Mbps Maximum Burst Size ....................................................................................... 16K Loopbac ...

  • METRObility Optical Systems RADIANCE R231-13 - page 14

    14 User Guide The maximum burst size can be adjusted to one of the following settings: 16, 32, 64, 128 or 256 kilobytes. Loopback Mode Y ou can enable loopback on either port on the locally managed card or on the remote fiber port. The loopback function allows a port to return its incoming data back to the sender , while continuing to receive and t ...

  • METRObility Optical Systems RADIANCE R231-13 - page 15

    Radiance Access Line Cards 15 Disabling a port stops the data flow to and from that port. Although data is neither sent nor received, the disabled port continues to accept, process and transmit management packets. However , if LLCF is enabled and the opposite port has no link, management packets will not be transmitted. Remote Management Statistics ...

  • METRObility Optical Systems RADIANCE R231-13 - page 16

    16 User Guide Singlemode Fiber Optic Power Monitors Through software * , you can read the input and output power levels of the singlemode fiber optic port on the access line cards with diagnostic capabilities. Input Power Level The accuracy of the input power monitor is ± 1 dBm from -28 dBm to -12 dBm. The accuracy is ± 2 dBm from -31 dBm to -29 ...

  • METRObility Optical Systems RADIANCE R231-13 - page 17

    Radiance Access Line Cards 17 Link Loss Carry Forward (LLCF) * The access line cards incorporate an LLCF function for troubleshooting a remote connection. When LLCF is enabled, the ports do not transmit a link signal until they receive a link signal from the opposite port. The diagram below shows a typical network configuration with a good link sta ...

  • METRObility Optical Systems RADIANCE R231-13 - page 18

    18 User Guide Link Loss Return (LLR) The fiber optic ports of the access line cards have been designed with an LLR function * for troubleshooting a remote connection. When LLR is enabled, the fiber port’ s transmitter shuts down if its receiver fails to detect a valid receive link. LLR should only be enabled on one end of the link and is typicall ...

  • METRObility Optical Systems RADIANCE R231-13 - page 19

    Radiance Access Line Cards 19 T opology Solutions Radiance R5000 Remote Device Customer Premises CO/POP SNMP Control Remote Communications Path Status Reporting Configuration Instructions Used Bandwidth = 0 ...

  • METRObility Optical Systems RADIANCE R231-13 - page 20

    20 User Guide T echnical Specifications Data Rate Data Rate ____________________ 100Mbps half duplex, 200Mbps full duplex Bit Delay ____________________________________ 66 bits (fiber to copper) ____________________________________ 51 bits (copper to fiber) Network Connections Singlemode F/O Interface (R231-14, R231-16) Connector __________________ ...

  • METRObility Optical Systems RADIANCE R231-13 - page 21

    Radiance Access Line Cards 21 Singlemode CWDM F/O Interface (R231-47, -49, -51, -53, -55, -57, -59, -61) Connector _____________________________________________________ LC W avelength ________________________________________ (see tables below) Supported Link Length __________________________ up to 60 km full duplex Cable T ype _____________________ ...

  • METRObility Optical Systems RADIANCE R231-13 - page 22

    22 User Guide Product Safety , EMC and Compliance Statements This equipment complies with the following requirements: •U L • CSA • EN60950 (safety CE) • FCC Part 15, Class A • EN55022 Class A (emissions CE) • EN55024: 1998 (immunity) • DOC Class A (emissions) • Class 1 Laser Product This product shall be handled, stored and disposed ...

  • METRObility Optical Systems RADIANCE R231-13 - page 23

    Radiance Access Line Cards 23 W arranty and Servicing Three-Y ear W arranty for the Radiance Access Line Card Metrobility Optical Systems, Inc. warrants that every Radiance access line card will be free from defects in material and workmanship for a period of THREE YEARS from the date of Metrobility shipment. This warranty covers the original user ...

  • METRObility Optical Systems RADIANCE R231-13 - page 24

    Product Manuals The most recent version of this manual is available online at http://www .metrobility .com/support/manuals.htm Product Registration T o register your product, go to http://www .metrobility .com/support/registration.asp 25 Manchester Street, Merrimack, NH 03054 USA tel: 1.603.880.1833 • fax: 1.603.594.2887 www .metrobility .com 566 ...

Produzent METRObility Optical Systems Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts METRObility Optical Systems RADIANCE R231-13 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen METRObility Optical Systems
- Bedienungsanleitungen RADIANCE R231-13
- Produktkarten METRObility Optical Systems
- Informationsbroschüren
- oder Energieetiketten METRObility Optical Systems RADIANCE R231-13
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung METRObility Optical Systems RADIANCE R231-13.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen METRObility Optical Systems RADIANCE R231-13, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen METRObility Optical Systems RADIANCE R231-13. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts METRObility Optical Systems RADIANCE R231-13 ansehen.

Die komplette Bedienungsanleitung des Geräts METRObility Optical Systems RADIANCE R231-13, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von METRObility Optical Systems RADIANCE R231-13 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von METRObility Optical Systems RADIANCE R231-13 verständlich ist.

Eine gänzliche Bedienungsanleitung von METRObility Optical Systems sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von METRObility Optical Systems RADIANCE R231-13 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von METRObility Optical Systems RADIANCE R231-13 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich METRObility Optical Systems RADIANCE R231-13, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts METRObility Optical Systems RADIANCE R231-13 - die uns die ersten Schritte während der Nutzung von METRObility Optical Systems RADIANCE R231-13 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit METRObility Optical Systems RADIANCE R231-13 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von METRObility Optical Systems RADIANCE R231-13 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich METRObility Optical Systems RADIANCE R231-13?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit METRObility Optical Systems RADIANCE R231-13 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit METRObility Optical Systems RADIANCE R231-13 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)