Bedienungsanleitung Subaru Robin Power Products RGX3510

86 Seiten 3.02 mb
Download

Zur Seite of 86

Summary
  • Subaru Robin Power Products RGX3510 - page 1

    . Generator Model RGXl810/RGX2410 RGX3510/RGX5510 ...

  • Subaru Robin Power Products RGX3510 - page 2

    CONTENTS Section Title Page 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. SPECIFICATIONS ."."""• """ O" O" O" O" C."."• ""."."• "O""" "O" 00-0-0" """ O" O""" O" O""""""& ...

  • Subaru Robin Power Products RGX3510 - page 3

    Section Title Page 11 . TROUBLESHOOTlNG .................................................................... 11-1 No AC Output ........................................................................ 11-2 ACvoltage istoo high ortoo low ................................................... 66 66 68 11 -3 AC voltage is normal at no.load. but the load c ...

  • Subaru Robin Power Products RGX3510 - page 4

    1. SPECIFICATIONS T I I T i i 00 rr NN 55 Inm E Q 0 O W Q a I Ln m I- 01 07 m - P CI CI 3 a CI tlOlVNtl3llV 3NIDN3 -1- ...

  • Subaru Robin Power Products RGX3510 - page 5

    ! >j c 6' si 0 d i N g ln - N g W 3 0 0 0 In - 3 0 0 m m ? l" I i i- ,. iI + x 0 cd Q u .- s I I X 3 X J a, c, m Y -. 8- w ULLL i '_ klOlVNkl3llV 3NIE)N3 i I .. -2- ...

  • Subaru Robin Power Products RGX3510 - page 6

    2. PERFOMANCE CURVES 2-1 MODEL RGX1810 2k 1.5k t lk z W I- 0.5k 2 0 0 s RGXl810 Output Ma. ...................... Rated ..................... Frequency ........................ Voltage ........................... 1500W 1300W 50Hz 110v 5 CURRENT(A) - RGXl810 Output Max. ...................... 1800W 1500W 1 1 ov, 120v ..................... 2k t Rated ...

  • Subaru Robin Power Products RGX3510 - page 7

    t t h 3 -1k 5 n -0.5k I- RGXl810 Output Ma. ...................... Rated ..................... Frequency ........................ Voltage ........................... 1800W 1500W 60Hz 220v - CURRENT(A) - 12* lk 1.5k t n 3 -0.5k 2 Y + t- 3 -0 o 5 CURRENT(A) - RGXl810 Output Ma. ...................... Rated ..................... Frequency ............ ...

  • Subaru Robin Power Products RGX3510 - page 8

    t2k t ‘3 -1.5k 5 5 0 -1k -0.5k -0 RGX1810 Output Max. ...................... 1800W Rated ..................... Frequency ........................ 60Hz Voltage ...................... 1 1 OV/220V 1500W CURRENT(A1- 2-2 MODEL RGX2410 /)* 1.5k 1 CURRENT(A) C z 61 3 60 s 59 L h > V 3 t 120 E 110 Y 100 s e 0 4 8 12 16 20 1.5k 0.5k 0 LO CURRENT(A1- -5 ...

  • Subaru Robin Power Products RGX3510 - page 9

    0 CURRENT(A) - -2k -1.5k z RGX2410 Output Ma. ...................... Rated ..................... Frequency ........................ Voltage ........................... 2400W 2000w 60Hz 220v -0 0 2 4 6 8 10 12 CURRENT(A) - -6- ...

  • Subaru Robin Power Products RGX3510 - page 10

    t 53 - 52 z * 51 5 50 E Y 0 x s 49 240 E 220 s = 120 g 200 110 100 0 4 8 12 16 20 RGX2410 Output Max. ...................... rk t ..................... 2000w Rated 1700W Frequency ........................ 50Hz 1.5k E n I- 3 c 3 lk CURRENT(A1 - CURRENT(A1- 2-3 MODEL RGX3510 B CURRENT(A1- lk 0 RGX3510 Output Max. ...................... 3k 3000W 2500W ...

  • Subaru Robin Power Products RGX3510 - page 11

    B CURRENT(A) - t t 63 62 61 60 59 240 220 200 0 4 8 12 16 CURRENT(A) - 4k 3k 2k t z lk 5 os n c 3k 2k t lk c 3 n 00 5 RGX3510 Output Ma. ...................... Rated ..................... Frequency ......................... 60Hz 3500W 3000W Voltage .................... 1 1 ov, 120v RGX3510 4k Output Ma. ...................... 3500W -a- ...

  • Subaru Robin Power Products RGX3510 - page 12

    0 10 20 30 CURRENT(A) - -9 3k t 2k 3 E lk 0 0 4k 3k t. z 2k 2 0 + s lk D '3k t 2k z 5 n lk g 0 0 RGX3510 Output Max. ...................... Rated ..................... Frequency ........................ Voltage ........................... 3000W 2500W 50Hz 240V RGX3510 Output Ma. ...................... Rated ..................... Frequency .... ...

  • Subaru Robin Power Products RGX3510 - page 13

    2-4 MODEL RGX5510 t -5k -4k -3k -2k -1k -0 .6k .5k ,4k 3k ,2k .lk 0 RGX5510 Output Max. ...................... t ..................... 5500W Rated 4aoow Frequency ........................ Voltage ..................... 60Hz 1 1 OV/120V z RGX5510 Output Ma. ...................... 5000W 4400W ..................... -5k t Rated ........................ ...

  • Subaru Robin Power Products RGX3510 - page 14

    6k 5k t 4k z 3k 2k lk 0 0 -2k 5 -1k 0 RGX5510 Output Ma. ...................... Rated ..................... Frequency ........................ 5500W 4800W 60Hz Voltage ........................... 220v CURRENT(A) - -2k -1k -0 CURRENT(A) - - 11 - ...

  • Subaru Robin Power Products RGX3510 - page 15

    RGX5510 Output Ma. ...................... 5500W 4800W ..................... 1””t Rated ........................ Frequency 60Hz Voltage ...................... 1 1 OV/220V 12OV/24OV 5k s I- -4k g 3 3 0 t 3k -2k -1k -0 CURRENT(A1- 2-5 DC OUTPUT (Option) DC Voltage ............... DCAmpere ............... DC output ............... 12v 8.3A 1 oow Th ...

  • Subaru Robin Power Products RGX3510 - page 16

    3. FEATURES 3-1 BRUSHLESS ALTERNATOR Newly developed brushless alternator eliminates troublesome brush maintenance. 3-2 CONDENSER-TYPE VOLTAGE REGULATOR A trouble free condenser type voltage regulator ensures a stable voltage under all working conditions. 3-3 OIL SENSOR Oil sensor automatically shuts off the engine whenever the oil level falls down ...

  • Subaru Robin Power Products RGX3510 - page 17

    4. GENERAL DESCRIPTION 4-1 EXTERNAL VIEW FULL POWER SWITCH VOLTMETER NO-FUSEBREAKER (RGX5510 DUAL VOLTAGE TYPE ONLY) IDLE CONTROL SWITCH DC FUSE HOLDER CHOKE LEVER (Option) AIR CLEANER AC RECEPTACLE DC OUTPUT TERMINAL (Option) EARTH (GROUND) TERMINAL FUEL COCK PLUG COVER (SPARK PLUG. INSIDE) OIL SENSOR TAN? CAP FUEL,GAUGE (Option : RGX 351 0 ONLY ...

  • Subaru Robin Power Products RGX3510 - page 18

    4-2 CONTROL PANEL RGX1810, RGX2410 : 50Hz, 60H~-llOV,12OV TYPE VOLTMETER DC FUSE (Option) DC OUTPUT TERMINAL (Option) RGX1810, RGX2410 : 50Hz, 60H~-220V, 240V TYPE VOLTMETER DC FUSE (Optionj DC OUTPUT TERMINAL (Optio / No-FUSEBREAKER AC RECEPTACLE 'EARTH (GROUND) TERMINAL / NO - FUSE BREAKER %AC RECEPTACLE - 15 - ...

  • Subaru Robin Power Products RGX3510 - page 19

    RGXl810, RGX2410 : 50Hz, 60Hz-11 OV/220V, 120V/240V TYPE VOLTMETER NO - FUSE BREAKER 220V RECEPTACLE DC FUSE (Option) 1 1 OV RECEPTACLE DC OUTPUT TERMINAL (Option) EARTH (GROUND) TERMINAL RGXl810,2410 : 50Hz-220V WITH SPECIAL RECEPTACLE] DC FUSE (Option) ,220V RECEPTACLE DC OUTPUT TERMINAL (Option) - 16- ...

  • Subaru Robin Power Products RGX3510 - page 20

    RGX1810,2410 : AUSTRALIA, 50HZ-240V VOLTMETER DC OUTPUT TERMINAL (Option) RGX3510 50Hz, 60Hz-1 lOV, 120V TYPE START SWITCH VOLTMETER (Option) I / NO - FUSE BREAKER 240V RECEPTACLE . NO-FUSEBREAKER / AC RECEPTACLE EARTH (GROUND) TERMINAL - 17- DC FUSE / (Option) DC OUTPUT TERMINAL (Option) ...

  • Subaru Robin Power Products RGX3510 - page 21

    RGX3510 : 50Hz, 60Hz-220VY 240V TYPE START SWITCH (Option) VOLTMETER / AC RECEPTACLE EAR~H (GROUND) TERMINAL RGX3510 : 5OHZ, 60Hz-1 10V/22OVy 120V/240V TYPE START SWITCH (Option) VOLTMETER I AC RECEPTACLE -c No -FUSE BREAKER / EARTH (GROUND) TERMINAL - 18- / DC FUSE (Option) DC OUTPUT TERMINAL (Option) NO-FUSEBREAKER / DCFUSE (Option) DC OUTPUT ...

  • Subaru Robin Power Products RGX3510 - page 22

    RGX3510 : 50Hz-220V [WITH SPECIAL RECEPTACLE] START SWITCH VOLTMETER (Option) I / 220v RECEPTACLE - EARTH (GROUND) TERMINAL RGX3510 : AUSTRALIA, 50HZ-240V START SWITCH VOLTMETER (Option) d I i C 0 0 1 No-FUSEBREAKER / /Dc FUSE (Option) DC'OUTPUT TERMINAL (Option) 240V RECEPTACLE EARTH (GROUND) TERMINAL - 19 - NO - FUSE BREAKER /Dc FUSE (Op ...

  • Subaru Robin Power Products RGX3510 - page 23

    RGX5510 : 50Hz, 60Hz-1 lOV, 120V TYPE DC FUSE (Option) VOLTMETER AC RECEPTACLE AC RECEPTACLE f NO-FUSEBREAKER - START SWITCH (Option) EARTH (GROUND) TERMINAL DC OUTPUT TERMINAL (Option) 0 RGX5510 : 60H~-220V/240V TYPE DC FUSE (Option) I J NO-FUSEBREAKER / -START SWITCH (Option) EARTH (GROUND) TERMINAL DC OUTPUT TERMINAL (Option) - 20 - ...

  • Subaru Robin Power Products RGX3510 - page 24

    RGX5510 : ~OHZ, 60H~-lIOV/220V, 120V/240V TYPE 220V RECEPTACLE VOLTMETER FULL POWER SWITCH NO -FUSE BREAKER DC FUSE (Option) - START SWITCH (Option) I 1 1 OV RECEPTACLE EARTH (GROUND) TERMINAL ' DC OUTPUT TERMINAL (Option) RGX5510 : 50Hz-220V [WITH SPECIAL RECEPTACLE] I VOLTMETER DC FUSE (Option) 220V RECEPTACLE NO - FUSE BREAKER / START SWITC ...

  • Subaru Robin Power Products RGX3510 - page 25

    RGX5510 : AUSTRALIA, 50Hz-240V VOLTMETER DC FUSE (Option) NO-FUSEBREAKER I / -START SWITCH (Option) 240V RECEPTACLE EARTH (GROUND) TERMINAL DC OUTPUT TERMINAL (Option) - 22 - ...

  • Subaru Robin Power Products RGX3510 - page 26

    4-3 LOCATION of SERIAL NUMBER and SPECIFICATION NUMBER Serial number and specification number are stamped on the LABEL (MODEL NAME) stuck on the side wall of control box. NOTE: Always specify these numbers when inquiring about the generator or ordering spare parts in order to get correct parts and accurate service. PEL, MODEL NAME - 23 - ...

  • Subaru Robin Power Products RGX3510 - page 27

    5. CONSTRUCTION AND FUNCTION 5-1 CONSTRUCTION REAR COVER ROTOR COMPLETE STATOR COMPLETE MOUNT RIBBER STATOR BOLT BALL BEARING THROUGH BOLT FRONT COVER 5-2 FUNCTION 5-2-1 STATOR The stator consists of a laminated silicon steel j I sheet core, a main coil and a condenser coil which I are wound in the core slots. The condenser coil excites the rotor f ...

  • Subaru Robin Power Products RGX3510 - page 28

    5-2-2 CONDENSER One or two condensers are installed in the control box and are connected to the condenser coil of the stator. These condensers and condenser coil regulate the output voltage. 5-2-3 ROTOR The rotor consists of a laminated silicon steel sheet core and a field coil which is wound over the core. DC current in the field coil magnetizes t ...

  • Subaru Robin Power Products RGX3510 - page 29

    5-2-4 DC FUSE (OPTION) I The 10 ampere DC fuse mounted on the control panel protects whole DC circuit from getting damage by overload or short circuit. 5-2-5 NO-FUSE BREAKER The KO-Fuse breaker protects the generator from getting damage by overloading or short circuit in Fig. 5-6 the appliance. Table 5-1 shows the capacity of No-Fuse breaker by eac ...

  • Subaru Robin Power Products RGX3510 - page 30

    5-2-6 RECEPTACLE and AC PLUG (STD.SPEC.) These are used for taking AC output power from the generator. A total of six kinds of receptacles, each varying in rated voltage and current from another, are used. Each model has at least one receptacle to deliver the rated generator output. As many AC plugs as the receptacles, each matching the correspondi ...

  • Subaru Robin Power Products RGX3510 - page 31

    5-3 GENERATOR OPERATION PERMANENT MAGNET FOR INITIAL EXCITATION ,- STATOR MAIN COIL ECEPTACLE APPLIANCE DIODE CONDENSER COIL CONDENSER Fig. 5-8 5-3-1 GENERATION Of NO-LOAD VOLTAGE IVhen the generator starts running: the permanent magnet built-in to the rotor generates 3 to 6V of AC voltage in the main coil and condenser coil wound on the stator. As ...

  • Subaru Robin Power Products RGX3510 - page 32

    5-3-3 FULL POWER SWITCH The full power switch is provided for the dual voltage type to take out the full rated power from one receptacle in each voltage. 0 Dual voltage type - RGX1810,2410,3510 N.F.B. * k -Qj- ""_ I I -Q+ """ REC: 11 OV (or 120V) RECr 220V (or 240V) Fig. 5-9 I I I Lower Voltage Receptacle Higher Voltage (RE ...

  • Subaru Robin Power Products RGX3510 - page 33

    0 Dual voltage type - RGX5510 120/24ov r - - - i (or 110/22OVl 240V (or 22OVl I 120V (or llOV1 Fig. 5- 10 - Ret. 1 Rec. 2 - Ret. 1 r i I MC, Fig. 5- 1 1 Switch i LOWER VOLTAGE HIGHER VOLTAGE Position I RECEPTACLE ; RECEPTACLE 11ov ' 120v ; I or I Rated output i No output can be taken. 110:'220v , Half of rated output : Rated output i 120/ ...

  • Subaru Robin Power Products RGX3510 - page 34

    Two main coils are wound over stator core. Each main coil outputs half the rated power at the lower voltage (llOV or 120V). These main coils are wound to be in the same phase. The full power switch reconnects these main coils in parallel or in series. Fig. 5-9 shows a circuit diagram.When the full power switch is set for single lower voltage indica ...

  • Subaru Robin Power Products RGX3510 - page 35

    5-4 ELECTRONIC IGNITION SYSTEM The electronic ignition system features a power transistor as the current control element. Therefore, the ignition system is an electronic contact point-free type that operates with the power transistor impulses controlling the current. This system is also called TIC (transistor igniter circuit) and is virtually free ...

  • Subaru Robin Power Products RGX3510 - page 36

    5-5 OIL SENSOR 5-5-1 DESCRIPTION 0 The oil sensor mainly functions to detect position of the surface of engine oil in the crankcase of engines for general use and to stop the engine automatically when the oil level goes down below the lower limit specified. This prevents seizure of engine from occurring due to insufficient amount of oil in the cran ...

  • Subaru Robin Power Products RGX3510 - page 37

    [Judgement of oil level] When sufficient oil is in the crankcase, both of inner and outer electrodes are immersed in the oil through which current flows across the electrodes. The sensor judges that oil in the crankcase is sufficient. %'hen oil level goes down and the inner electrode is exposed to the air due to consumption of oil, no current ...

  • Subaru Robin Power Products RGX3510 - page 38

    !& Detection circuit-...... This detects quantity of oil, sufficient or not, according to difference of electric resistance across inner and outer electrodes. n n & Delay circuit a. e. - This his prevents the sensor from making an unnecessary stop of the engine by momentary lowering of the oil level due to the engine being slanted or affect ...

  • Subaru Robin Power Products RGX3510 - page 39

    6. 1. 2. 3. 4. 5. 6. SAFETY PRECAUTIONS Use extreme caution near-fuel. A constant danger of explosion or fire exists. Do not fill the fuel tank while the engine is running. Do not smoke or use opern flame near the fuel tank. Be careful not to spill fuel when refueling. If spilt, wipe it and let dry before starting the engine. Do not place inflammab ...

  • Subaru Robin Power Products RGX3510 - page 40

    7. RANGE OF APPLICATIONS Generally, the power rating of an electrical appliance indicates the amount of work that can be done by it. The electric power required for operating an electrical appliance is not always equal to the output wattage of the appliance. The electrical appliances generally have a label showing their rated voltage, frequency, an ...

  • Subaru Robin Power Products RGX3510 - page 41

    (5) Appliances without any indication as to power consumption Some appliances have no indication as to power consumption; but instead the work load (output) is indicated. In such a case, power consumption is to be worked out according to the numerical formula mentioned below. (Output of electrical appliance) (Efficiency) = (Power consumption) Effic ...

  • Subaru Robin Power Products RGX3510 - page 42

    NOTES: Wiring between generator and electrical appliances 1. Allowable current of cable Use a cable with an allowable current that is higher than the rated input current of the load (electrical appliance). If the input current is higher than the allowable current of the cable used, the cable will become excessively heated and deteriorate the insula ...

  • Subaru Robin Power Products RGX3510 - page 43

    8. MEASURING PROCEDURES 8-1 MEASURING INSTRUMENTS 8-1-1 "Dr. ROBIN" GENERATOR TESTER The "Dr. Robin" generator tester is exclusively designe.d for fast, easy diagnosis and repair of I ! Robin generators. I .:. The "Dr. Robin" has the following features: (1) Functions of voltmeter, frequency meter, meggertester, capacit ...

  • Subaru Robin Power Products RGX3510 - page 44

    8-1-2 INSTRUMENTS ! j (1) VOLTMETER AC voltmeter is necessary.The approximate AC voltage ranges of the voltmeters to be used for various types of generators are as /. ;G@ i I e 0 to 15OV: Type with an output voltage of : .. . i .. a. . follows: ! G 5 I 110 or 120V 4 3 0 to 3OOV: Type with an output voltage of 220,230 or 240V 0 to EOV, 0 to 33OV: D ...

  • Subaru Robin Power Products RGX3510 - page 45

    (4) CIRCUIT TESTER Used for measuring resistance, etc. MEGGER TESTER Used for measuring generator insulation resistance. . Select one Kith testing voltage range of 5oov. (6) TACHOMETER Use the contactless type tacho meter. ! Fig. 8-5 1 i I Fig. 8-6 J Fig. 8-7 - 42 - ...

  • Subaru Robin Power Products RGX3510 - page 46

    8-2 AC OUTPUT MEASURING Use a circuit like the shown in Fig.8-8 for measuring AC output. A hot plate or lamp with a power factor of 1.0 may be used as a load. Adjust the load and rpm. and check that the voltage range is as specified in Table 8-2 at the rated amperage and rated rpm. Rated voltage Table 8-2 117-13OV I 215-238V I 235-26QV 107 - 11 9V ...

  • Subaru Robin Power Products RGX3510 - page 47

    8-4 MEASURING INSULATION RESISTANCE Use a "Dr. Robin'' generator tester in megger tester mode or use a megger tester to check the insulation resistance. Connect a megger tester to one of receptacle output terminals and the ground terminal, then measure the insulation resistance. An insulation resistance of 1 megohm or more is normal. ...

  • Subaru Robin Power Products RGX3510 - page 48

    Measure the insulation resistances between the live parts and the grounded parts. 0 CONTROL PANEL i Fig. 8-13 Any part where the insulation resistance is less than lMQ has faulty insulation, and may cause electric leakage and electric shock. Replace the faulty part. - 45 - ...

  • Subaru Robin Power Products RGX3510 - page 49

    9. CHECKING FUNCTIONAL MEMBERS 9-1 VOLTMETER Check the voltmeter if it is turned on by applying specific voltage. i Voltmeter cannot be checked with circuit tester ! AC because its resistance is too large. I i i Voltmeter I Fig. 9-1 9-2 AC RECEPTACLES . Using a "Dr. Robin" or a circuit tester, check continuity between the two terminals at ...

  • Subaru Robin Power Products RGX3510 - page 50

    9-3 NO-FUSE BREAKER Check continuity between each of two terminals at the rear of the No-Fuse breaker while it is mounted on the control panel. Normally, there is continuity between each of the two when the 30-Fuse breaker is on while there is no continuity when the No-Fuse breaker is off. 9-4 STATOR Disengage connectors on the wires from stator an ...

  • Subaru Robin Power Products RGX3510 - page 51

    9-5 (1) ROTOR ASSEMBLY Using a "Dr. Robin" or a circuit tester, measure the resistance of the field coil at the terminals. (0) ! MODEL I RGXl810 I RGX2410 i RGX3510 i RGX5510 I I RESISTANCE 1.62 R 2.0 R 1.88 R 1.74 R Table 9-2 NOTE 1: Because a diode is soldered to the coil ends at the terminals, resistance may be measured only when teste ...

  • Subaru Robin Power Products RGX3510 - page 52

    NORMAL CAPACITY OF CONDENSER I RGX1810 I RGX2410 I RGX3510 I RGX5510 I I 1 7,z F 2OcF i 17,zF+20#F I 28,zFX2 Table 9-3 W If such an instrument is unavailable, the condenser can be checked by replacing with a new one. If the generator performs good with new condenser, the cause of trouble is defect in original condenser. 9-7 DIODE RECTIFIER Brown Br ...

  • Subaru Robin Power Products RGX3510 - page 53

    W Checking table for digital circuit tester. ! Apply red @needle of the circuit tester Digital circuit tester I Brown j Brown I Orange Brown;White I Brown Brown I NO contir;uity 11 - NO continuity i NO continuity I Ccntinuity Orange. i Continuity i Continuity No coniinuiiy Continuity Continuity Apply black 0 needle of the circuit tester i I ! ’ B ...

  • Subaru Robin Power Products RGX3510 - page 54

    10. DISASSEMBLY AND ASSEMBLY 10-1 PREPARATION and PRECAUTIONS 1) Be sure to memorize the location of individual parts when disassembling the generator so that the v generator can be reassembled correctly. Tag the disassembled part with the necessary information to facilitate easier and smoother reassembly. 2) For more convenience,divide the parts i ...

  • Subaru Robin Power Products RGX3510 - page 55

    10-2 DISASSEMBLY PROCEDURES Step ;Part to remove I Description Remarks Tool I 1. Fuel Tank i (1) Discharge fuel from the tank. 1. Shut the fuel strainer. 2. Remove the strainer cup. 3. Put a vessel LO receive fuel under the strainer and open the fuel cock to dischzrge fuel. (See Fig. 10-1.) 1. Atrach [he straicer cap to tine srrainer bo+. Use utmos ...

  • Subaru Robin Power Products RGX3510 - page 56

    Step 2. - Part to remove I . Description I Remarks i Tool Control Box (1) Take off the grommet from the rear pannel of control box. ! - (2) Disconnect the connectors on the wiring from the control box to the alternator. (3) Rerxove the fuel strainer. Rerr.o.:e the nut on top of the fuel strainer located beside the contro! box. [See Fig. 10-5.)- L F ...

  • Subaru Robin Power Products RGX3510 - page 57

    I step Part to remove I Description Remarks Tool 1 (See Fig 10-8.) box wrench 3. I Pipe Frame (1) Remove SIDE PLATE from frame. 10 mm spanner or I 6 mm bolt . . . . . . . . . . . . . . . . 2 PC-. i I (2) Remove the nuts Lvhich fix [he engine 1 1 and alternator on the mount rubbers. 1 (3) Dismount the engine and alternator from I Take out the engine ...

  • Subaru Robin Power Products RGX3510 - page 58

    I Description Step I Part to remove 1 Remarks ! Tool L 4. Rear Cover ! il j Remove the four bolts Lvhich fxen the I 12 mm. spanner or I I . . rear cover to the front cover. i box wench -1 69 bolt-. . . . . . . . . . . . . . . . 4 pes. I I I i Do not give 2 strong hit 1 Plastic hammer ! (2) Rmove the rear cover by hitting on the I on the legs. I i l ...

  • Subaru Robin Power Products RGX3510 - page 59

    Step Tool Remarks Description Part to remove 5. Stator I i j ! I 6. - STATOR COVER CLAMP Fig. 70-73 (1 j Take off the through bolt. i Apply a box wench on the head of j through bolt. Hit the wrench hzndle with I a hammer cocnter-clockwise to loosen. ! ! I Fig. 10-14 (2) Put the engine on the working table recoil starter side down. Box wrench Plasti ...

  • Subaru Robin Power Products RGX3510 - page 60

    Step Part to remove Description ! Remarks i ! i 6. Rotor (3j Use a bolt and oil as a tool for pulling j I out rotor in the following procedures : 1 : 1. Pour engine oil into the center hole of i ! rotor shaft. Fill Lvith oil to the shaft end. (See Fig. 10-15.) thread size: 1 : 2. Prepare a bolt with the following i I I i i RGX1810, 2410,3510. . h.I ...

  • Subaru Robin Power Products RGX3510 - page 61

    step I Part to remove Description Remarks i Tool (1) Remo1.e rhe front cover. I Loosen the four bois and remove the I front cover. 30 bolt. . . . . . . . . . . . . . . . 4 pes. 12 mm Socket vrench I I Fig. 10-18 - 58 - ...

  • Subaru Robin Power Products RGX3510 - page 62

    10-3 ASSEMBLY PROCEDURES 10-3-1 FRONT COVER Attach the front cover to the engine main bearing cover. Match the faucet joint and tighten the bolts. M8 X 18mm bolt. . . . . .4 pcs. “8 spring washer . . . . . 4 pcs. 120 - 140 kgocrn ‘1 8.7- 10.1 ft*lb 10-3-2 ROTOR (1) Wipe off oil, grease and dust from the tapered portion of (2) Mount the rotor ...

  • Subaru Robin Power Products RGX3510 - page 63

    10-3-3 STATOR (1) Put the stator in the rear cover setting the four : - grooves on the side of stator with thread holes ' of the rear cover; i ! ! (2) Attach.the stator cover around the stator. ! STATOR COVER I I """" I' I :' I .T- -. . - I I Fig. 10-20 10-3-4 REAR COVER (1) Put the rear cover with stator over the ...

  • Subaru Robin Power Products RGX3510 - page 64

    (3) Attach the bushing over the lead wire drawn out from the rear cover. Press the smaller -end of the bushing into the window of the rear cover. i I j Fig. 10-22 10-3-5 FRAME (1) Attach the mount rubbers to the frame. Insert the setting tongue of mount rubber into the hole on the frame and tighten the nut from the bottom of the frame. h18 flan, nu ...

  • Subaru Robin Power Products RGX3510 - page 65

    Install the engine and alternator assembly into the frame. Put the engine and alternator assembly into the frame from the side of it. Tighten the nuts over the mount rubber bolts to fix. Tightening torque 1 1.8 - 13.7 Nom :. 120 - 140 kg*cm .i ’, 8.7 - 10.1 ft*lb ; Fig. 10-24 NOTE : When tightening the nuts, slightly lift the engine and alternato ...

  • Subaru Robin Power Products RGX3510 - page 66

    (3) Press the upper end of the bushing into the bottom window of the control box. Attach the grommet for the oil sensor wires to the rear panel of the control box. (4) Mount the control box to the frame. 346 X12 mm flange bolt .......... 3 pcs I Tightening torque I 3.9 - 5.9 Nom / 40- 60 kg-cm ':! !, 2.9-4.3 ftolb / (5) Fasten the one earth ca ...

  • Subaru Robin Power Products RGX3510 - page 67

    10-3-7 FUEL TANK 1) Connect the rubber pipe to the engine carburetor and fasten it with a hose clamp. Attach the banjo to the opposite end of the rubber pipe, tighten it with a hose clamp, and fasten the pipe to the fuel strainer with the banjo bolt. 2) Fasten the strainer to the strainer bracket with the joint nuts. 3) Mount the fuel tank on the s ...

  • Subaru Robin Power Products RGX3510 - page 68

    10-4 CHECKING, DISASSEMBLY and REASSEMBLY of the CONTROL BOX 10-4-1 CHECKING OF THE CONTROL BOX Dismount the control box from frame. Remove the control panel and check each components and wiring. Refer to Section 9 for the detail of checking procedure for the components in the control box. 10-4-2 DISASSEMBLY (1) Remove the control panel from the co ...

  • Subaru Robin Power Products RGX3510 - page 69

    11. TROUBLESHOOTING 11-1 NO AC OUTPUT 11 -1 -1 CHECKING CONDENSER 1) Check the capacity of condensers using a ”Dr. R0bin”generator tester in capacitance meter mode. NOTE : Be sure to discharge condensers by shorting condenser leads each other before checking their capacitance, or the accurate reading cannot be obtained. RGX1810, RGX2410 RGX3510 ...

  • Subaru Robin Power Products RGX3510 - page 70

    3) Check the insulation resistance between stator core and each stator lead using a Dr. Robin generator tester in megger tester mode or a ' megger tester. (Fig. 11-3) If insulation is bad, replace stator with a new j one. I I Fig. 1 1-3 11 -1-3 CHECKING ROTOR 1) Remove rear cover and stator. Using a Dr. Robin or a circuit tester, measure the r ...

  • Subaru Robin Power Products RGX3510 - page 71

    3 ) Measure the insulation across on e o f the soldered terminal s o f the rotor and th e core. (Fig . 11-6) I f insulation is bad, replace rotor with a new one. 11-2 AC VOLTGE IS TOO HIGH OR TOO LOW 11-2- 1 CHECKIN G ENGINE SPEED I f the engine speed is too hig h o r to o low. , adjus t it t o the rated r.p.m. [Ho w t o adjus t engin e r.p.m.1 w L ...

  • Subaru Robin Power Products RGX3510 - page 72

    11-3 AC VOLTAGE IS NORMAL AT NO-LOAD, BUT THE LOAD CANNOT BE APPLIED. 11-3-1 CHECK THE ENGINE SPEED. If the engine speed is low, adjust it to the rated r.p.m. * Refer to Step 11-2-1 for engine speed adjustment. 11-3-2 CHECK THE TOTAL WATTAGE OF APPLIANCES CONNECTED TO THE GENERATOR. Refer to Section 7 “RANGE OF APPLICATIONS” for the wattage of ...

  • Subaru Robin Power Products RGX3510 - page 73

    11 -4-2 CHECK THE DC FUSE. Check the fuse in the fuse holder. If the fuse is blown, check for the cause of fuse blowing, and then replace with a new one. NOTE: If the DC output is used to charge a large capacity battery or an over-dis- charged battery, an excessive current may flow causing fuse blow. FC-SE : 10A 11-4-3 CHECK THE WIRING. Check all t ...

  • Subaru Robin Power Products RGX3510 - page 74

    11-5 IDLE CONTROL (Option for 60Hz only) 11 -5-1 ENGINE- SPEED IS NOT INCREASED WHEN A LOAD IS APPLIED (1) Inspect the solenoid bracket. Check the bend angle of solenoid bracket. i If the bracket is distorted, correct the angle ' with proper tool. 1 I ! SOLENOID SOLENOID BRACKET RGX5510 Fig. 11-12 (2) Check the wattage of load appied to the ge ...

  • Subaru Robin Power Products RGX3510 - page 75

    (4) Check the wiring through ZCT on the IDLE CONTROL UNIT BOARD. 0 Single Voltage Type Make sure that an output wire from main coil is passing through the ZCT on the IDLE CONTROL UNIT. 0 Dual Voltage Type Check that two output wires (black wire and red wire) from main coils are passing through the ZCT on the IDLE CONTROL UNIT in the same direction. ...

  • Subaru Robin Power Products RGX3510 - page 76

    11-5-2 ENGINE SPEED IS NOT REDUCED WHEN LOAD IS OFF. (1) Check the distortion of the SOLENOID BRACKET as shown in step 11-5-1-(1). (2) Check the FUSE on wiring of IDLE CONTROL UNIT. Remove the. control panel from control box. Check the FUSE in the fuse holder of IDLE COKTROL UNIT. If fuse is blown, replace with a new one. (FUSE : 0.2A) FUSE HOLDER ...

  • Subaru Robin Power Products RGX3510 - page 77

    12. WIRING DIAGRAM 1. RGX1810, RGX2410 (llOV, 120V) I 1 EhlC I I I NFB GENERATOR CONTROLBOX "I I" "I 1 '-3 1 YELLOW "I I " " I DC OUTPUT : Available as option DC OUT 2. RGX1810, RGX2410 (220V, 240v) GENERATOR CONTROL BOX L "I r " " iii II NFB AK n I I, GREENBELLOW YELLOW P I E YELLOW BROWN DC OUT BR ...

  • Subaru Robin Power Products RGX3510 - page 78

    3. RGXl810, RGX2410 (1 1 OV/22OV) (1 20V/240V) GENERATOR CONTROL BOX 7°F 1" DC OUTPUT : Available as option 4. RGX3510 (1 lOV, 120V) GENERATOR "1 I" CONTROL BOX " .. DC OUT " " DC OUTPUT : Available as option - 75 - ...

  • Subaru Robin Power Products RGX3510 - page 79

    5. RGX3510 (220V, 240V) DC OUTPUT : Available as option 6. RGX3510 (1 1 OV/22OV) (120V/240V) GENERATOR CONTROLBOX "I I" I I II NFB DC OUT - E DC OUTPUT : Available as option - 76 - ...

  • Subaru Robin Power Products RGX3510 - page 80

    7. RGX5510 (1 1 OV, 120V) GENERATOR CONTROL BOX "1 I" " AK I DC OUTPUT-: Available as option 8. RGX5510 (220V, 240V) GENERATOR CONTROL BOX " " - 77 - ...

  • Subaru Robin Power Products RGX3510 - page 81

    9. RGX5510 (1 1 OV/220V) (1 20V/240V) GENERATOR CONTROLBOX "1 I " " I NFBl lc ORAN YELLOW YELLOW +T DC OUT 0 BROWN - BROWN/WHITE "1 I " " DC OUTPUT : Available as option - 78 - ...

  • Subaru Robin Power Products RGX3510 - page 82

    ENGINE WIRING DIAGRAM .: RECOIL STATER TYPE """_ rm-4 I J r--- -0 I _J " ENGINE - 79 - ...

  • Subaru Robin Power Products RGX3510 - page 83

    0 ENGINE WIRING DIAGRAM : ELECTRIC STATER (Optional Equipment) TYPE for RGX3510 ""7 I ...

  • Subaru Robin Power Products RGX3510 - page 84

    0 ENGINE WIRING DIAGRAM : ELECTRIC STATER (Optional Equipment) TYPE for RGX5510 I GREENiWHITE Ir--------"h The battery cords have a cross sectional area of 22 mm'. """" - 0.75 mm2 "- 1.25 mm2 - 81 - ...

  • Subaru Robin Power Products RGX3510 - page 85

    Symbols I Part Name M c AC Winding SC . 1 Auxiliary Winding DC DC Outpgt Terminal T Diodes Stack Assy D C I Condenser Field Winding FC DC Winding F Fuse NFB, j No-Fuse Breaker NFB, 1 No-Fuse Breaker FP SW I Fdll Power Switch S SW i Engine Stop Switcn I os Spark Plug SP Oil Sensor M G j Magneto IG ' j Ignition Coil MG. SW Magnetic Swiich E Ea ...

  • Subaru Robin Power Products RGX3510 - page 86

    I ISSUE EMD-GS1001 I @FUJI HEAVY INDUSTRIES LTD. ...

Produzent Subaru Robin Power Products Kategorie Portable Generator

Dokumente, die wir vom Produzenten des Geräts Subaru Robin Power Products RGX3510 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Subaru Robin Power Products
- Bedienungsanleitungen RGX3510
- Produktkarten Subaru Robin Power Products
- Informationsbroschüren
- oder Energieetiketten Subaru Robin Power Products RGX3510
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Subaru Robin Power Products RGX3510.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Subaru Robin Power Products RGX3510, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Subaru Robin Power Products RGX3510. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Subaru Robin Power Products RGX3510 ansehen.

Die komplette Bedienungsanleitung des Geräts Subaru Robin Power Products RGX3510, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Subaru Robin Power Products RGX3510 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Subaru Robin Power Products RGX3510 verständlich ist.

Eine gänzliche Bedienungsanleitung von Subaru Robin Power Products sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Subaru Robin Power Products RGX3510 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Subaru Robin Power Products RGX3510 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Subaru Robin Power Products RGX3510, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Subaru Robin Power Products RGX3510 - die uns die ersten Schritte während der Nutzung von Subaru Robin Power Products RGX3510 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Subaru Robin Power Products RGX3510 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Subaru Robin Power Products RGX3510 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Subaru Robin Power Products RGX3510?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Subaru Robin Power Products RGX3510 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Subaru Robin Power Products RGX3510 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)