  • Pentair Model 5600 & 5600 Econominder - page 1

    Model 5600 & 5600 Econominder ® Service Manual IMPORTA NT: Fill in p ertinent info rmation on page 3 for future reference. ...

  • Pentair Model 5600 & 5600 Econominder - page 2

    2 Model 5600 & 5600 Econominder ® Table of Contents Job Specification Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 General Residential Installation Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Pentair Model 5600 & 5600 Econominder - page 3

    Model 5600 & 5600 Econominder ® 3 Job Specification Sheet Job Number _______________ _________________ ___ Model Number __ __________________ ____________ W ater T est _____________ _________________ ______ Capacity of Unit __________ ______________ Max. __ ___________ Per Regeneration Mineral T ank Size: Diameter ____ _______________ Heigh t ...

  • Pentair Model 5600 & 5600 Econominder - page 4

    4 Model 5600 & 5600 Econominder ® General Residential Installation Check List W at er Pressur e A minimum of 25 lbs of water pressure is r equ ired for regeneration valve to operate effectively . Electrical Facilities An uninterrupted alternating current (A/C) suppl y is required. Please make sure voltage su pply is compatible with unit before ...

  • Pentair Model 5600 & 5600 Econominder - page 5

    Model 5600 & 5600 Econominder ® 5 Valve Installation and Start-up Procedures 1. Place the softener ta nk where you want to install the unit. NOTE: Be sure the tank is level and on a firm base. 2. During cold weather it is recommended th at the installer warm the valve to room temperature before operatin g. 3. Perform all plumbing according to ...

  • Pentair Model 5600 & 5600 Econominder - page 6

    6 Model 5600 & 5600 Econominder ® Model 5600 Installation and Start-up Procedures NOTE: Install the water softener with th e inlet, outlet and drain connections made according to manufacturer’ s recommendations and to m eet applicable plumbing cod es. 1. Manually index the softener control into the In Service position and let water flow into ...

  • Pentair Model 5600 & 5600 Econominder - page 7

    Model 5600 & 5600 Econominder ® 7 Model 5600 Backwash Filter Installation and Start-up Procedures NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’ s recommendations and to meet applicable pl umbing codes. Before Plugging in the Unit 1. Open a treated water tap down stream of the fi ...

  • Pentair Model 5600 & 5600 Econominder - page 8

    8 Model 5600 & 5600 Econominder ® Model 5600 Backwash Filter Installation and Start-up Procedures (Cont’d.) Cycle Times and Flow Diagrams 1. In Service position. See Figure 4, page 10 . 2. Preliminary Rinse position. — Same as Figure 4, page 10 with standard piston (white end plug) or filter piston (black end plug). — Eliminated with low ...

  • Pentair Model 5600 & 5600 Econominder - page 9

    Model 5600 & 5600 Econominder ® 9 Model 5600 Econominder Installation and Start-up Procedures NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’ s recommendations and to meet applicable pl umbing codes. 1. Manually index the softener control to the In Service position and let water f ...

  • Pentair Model 5600 & 5600 Econominder - page 10

    10 Model 5600 & 5600 Econominder ® Water Conditioner Flow Diagrams Service Position Pr eliminary Rinse Position Figur e 4 : Service Position Figur e 5 : Preliminary Rinse Position ...

  • Pentair Model 5600 & 5600 Econominder - page 11

    Model 5600 & 5600 Econominder ® 11 Water Conditioner Flow Diagrams (Cont’d.) Backwash Position Brine Position Figur e 6 : Backwash Position Figur e 7 : Brine Position ...

  • Pentair Model 5600 & 5600 Econominder - page 12

    12 Model 5600 & 5600 Econominder ® Water Conditioner Flow Diagrams (Cont’d.) Slow Rinse Position Second Backwash Position Figur e 8 : Slow Rinse Position Figur e 9 : Second Ba ckwash Position ...

  • Pentair Model 5600 & 5600 Econominder - page 13

    Model 5600 & 5600 Econominder ® 13 Water Conditioner Flow Diagrams (Cont’d.) Settling Rinse Position Brine T ank Fill Position Figure 10 : Settling Rinse Position Figur e 1 1 : Brine T ank Fill Position ...

  • Pentair Model 5600 & 5600 Econominder - page 14

    14 Model 5600 & 5600 Econominder ® Model 5600 Control Valve Drive Assembly Figur e 12 : Model 5600 Control V alve Drive Assembl y 1 29 27 20 16 15 19 22 5 1A 1A 13 14 37 39 12 38 34 21 7 8 6 9 2 3 4 11 26 28 5 30 35 23 5 25 ...

  • Pentair Model 5600 & 5600 Econominder - page 15

    Model 5600 & 5600 Econominder ® 15 Model 5600 Control Valve Drive Assembly ▲ Not used when a filter valve Item Number No. Req’d Part Number Description 1 1 14448-010 housing, with pin 1 14448-011 housing, with pin drilled for screw 1 14448-012 housing, with pin drilled for thumb screw 1A 1 15494-01 “L” housing, with pin 1 15494-03 “L ...

  • Pentair Model 5600 & 5600 Econominder - page 16

    16 Model 5600 & 5600 Econominder ® Model 5600 and 5600 Econominder Control Valve Drive Assembly Figure 13 : Model 5600 and 5600 Econominder Control V alve Drive Assembly 48 47 10 49 50 12 11 9 8 2 7 2 3 16 15 1 17 55 20 22 23 21 26 14 53 39 42 43 52 Backwash Filter Injector Option 34 33 32 29 20 30 20 31 27 28 46 18 4 19 42 43 5 22 39 40 38 52 ...

  • Pentair Model 5600 & 5600 Econominder - page 17

    Model 5600 & 5600 Econominder ® 17 Model 5600 and 5600 Econominder Control Valve Drive Assembly * not used wi th meter controls ▲ used in backwash fi lter Item Number No. Req’d Part Number Description 1 2-4 13255 adapter clip (c lock or meter) 2 5 13242 seal 5 17772 silicone s eal 3 1 61400-12 valve body asse mbly , 1 ″ dist. 1 61400-11 ...

  • Pentair Model 5600 & 5600 Econominder - page 18

    18 Model 5600 & 5600 Econominder ® Model 5600 Econominder Control Valve Drive Assembly Figur e 14 : Model 5600 Econominder Control V alve Drive Assembly 29 1 27 19 20 18 21 1A 13 12 42 14 44 43 34 16 15 7 8 6 9 2 3 4 28 25 5 23 5 11 35 45 30 37 38 40 39 41 22 24 ...

  • Pentair Model 5600 & 5600 Econominder - page 19

    Model 5600 & 5600 Econominder ® 19 Model 5600 Econominder Control Valve Drive Assembly Item Number No. Req’d Part Number Description 11 14448-000 housing, with roll pin 1 14488-001 housing, with pin drilled for screw 1 14448-0 housing, with pi n drilled for thumb screw 1A 1 15494-01 “L” housin g, with pin 1 15494-03 “L” housing, w it ...

  • Pentair Model 5600 & 5600 Econominder - page 20

    20 Model 5600 & 5600 Econominder ® Bypass Valve Assembly, Plastic Figur e 15 : Bypass V alve Assembly , Plastic Item Number No. Req’d Part Number Description 9 2 13305 o-ring, 1 19 10 2 13255 clip, mounting 11 2 13314 screw , hex washer head, #8-18 x 5/8 " 12A 1 18706 yoke, plastic 1" NP T 1 18706-02 yoke, plastic 3/4" 12B 1 1 ...

  • Pentair Model 5600 & 5600 Econominder - page 21

    Model 5600 & 5600 Econominder ® 21 Bypass Valve Assembly, Brass Figur e 16 : Bypass V alve A ssembly , Brass Item Number No. Req’d Part Number Description 1 1 17290 bypass valve body , 3/4" 1 17290NP bypass valve body , 3/4") 1 13399 bypass valve body , 1" 1 13399NP bypass valve body , 1" (nickel-plated) 2 1 1 1726 seal, ...

  • Pentair Model 5600 & 5600 Econominder - page 22

    22 Model 5600 & 5600 Econominder ® Model 5600 Econominder Meter Assembly Figure 17 : Model 5600 Eco nominder Meter Assembly Item Number No. Req’d Part Number Description 1 4 12473 screw , meter cover assembly 2A 1 14038 meter cover assembly , standard 2B 1 15659 meter cover assembly , extended range (right angle) 3 1 13847 o-ring, meter cove ...

  • Pentair Model 5600 & 5600 Econominder - page 23

    Model 5600 & 5600 Econominder ® 23 Service Instructions Replace Time Brine V alve, Injectors and Scr een 1. Unplug electrical cord from outlet. 2. Turn off water supply to conditioner: — If the conditioner installation h as a “three valve” bypass sy st em, first open the valve in the bypass line, then close the valves at the conditioner ...

  • Pentair Model 5600 & 5600 Econominder - page 24

    24 Model 5600 & 5600 Econominder ® Service Instructions (Cont’d.) Replace Timer 1. Unplug electrical cord from outlet. 2. Turn off water supply t o conditioner: — If the conditioner i nstallation has a “three valve” bypass system, fi rst open the valve in the bypass l ine, then close the valves at the conditioner inlet and ou tlet. — ...

  • Pentair Model 5600 & 5600 Econominder - page 25

    Model 5600 & 5600 Econominder ® 25 Service Instructions (Cont’d.) Replace Piston Assembly 1. Unplug electrical cord from outlet. 2. Turn off water supply to conditioner: — If the conditioner installation h as a “three valve” bypass sy st em, first open the valve in the bypass line, then close the valves at the conditioner inl et and ou ...

  • Pentair Model 5600 & 5600 Econominder - page 26

    26 Model 5600 & 5600 Econominder ® Service Instructions (Cont’d.) Replace Seals and Spacers 1. Unplug electrical cord from outlet. 2. Turn off water supply t o conditioner: — If the conditioner i nstallation has a “three valve” bypass system, fi rst open the valve in the bypass l ine, then close the valves at the conditioner inlet and ...

  • Pentair Model 5600 & 5600 Econominder - page 27

    Model 5600 & 5600 Econominder ® 27 Service Instructions (Cont’d.) Replace Meter 1. Unplug electrical cord from outlet. 2. Turn off water supply to conditioner: — If the conditioner installation h as a “three valve” bypass sy st em, first open the valve in the bypass line, then close the valves at the conditioner inl et and outlet. — ...

  • Pentair Model 5600 & 5600 Econominder - page 28

    28 Model 5600 & 5600 Econominder ® Service Instructions (Cont’d.) Replace Meter Cover and/or Impeller 1. Unplug electrical cord from outlet. 2. Turn off water supply to conditioner: — If the conditioner installation h as a “three valve” bypass sy st em, first open the valve in the bypass line, then close the valves at the conditioner i ...

  • Pentair Model 5600 & 5600 Econominder - page 29

    Model 5600 & 5600 Econominder ® 29 Model 5600 and 5600 Econominder Troubleshooting PROBLEM CAUSE CORRECTION 1. Softener fails to regenerate. A. Electrical service to un it has been interrupted. A. Assure permanent electrical service (check fuse, plug, pull chain or switch). B. T imer is defective. B. Replace timer . C. Power failure. C. Reset ...

  • Pentair Model 5600 & 5600 Econominder - page 30

    30 Model 5600 & 5600 Econominder ® Model 5600 and 5600 Econominder Troubleshooting (Cont’d.) General Service Hints for Meter Contr ol PROBLEM CAUSE CORRECTION 9. Softener fails to draw brine. A. Draw line flow control is plugged. A. Clean drain line flow control. B. Injector is plugged. B. Clean or replace injectors. C. Injector screen plugg ...

  • Pentair Model 5600 & 5600 Econominder - page 31

    Model 5600 & 5600 Econominder ® 31 Model 5600SF Troubleshooting PROBLEM CAUSE CORRECTION 1. Filter fails to backwash. A. Electrical service to unit has been interrupted. A. Assure permanent electrical service (check fuse, plug, pull chain or switch). B. T imer is defective. B. Replace timer . C. Power failure. C. Reset time of day . 2. Filter ...

  • Pentair Model 5600 & 5600 Econominder - page 32

    32 Model 5600 & 5600 Econominder ® Service Assemblies Part Number Description 60102-00 piston, softener 60102-10 piston, filter 60102-20 piston, low water 60125 seal kit 60084-XX injector 60032 brine valve 60514 brine cam, 3-18 60514-01 brine cam, 6-36 60514-02 brine cam, minutes 60510 coupling, with clip and screws 60040 bypass, brass 3/4&quo ...

  • Pentair Model 5600 & 5600 Econominder - page 33

    Model 5600 & 5600 Econominder ® 33 Notes: ...

  • Pentair Model 5600 & 5600 Econominder - page 34

    34 Model 5600 & 5600 Econominder ® Notes: ...

  • Pentair Model 5600 & 5600 Econominder - page 35

    ...

  • Pentair Model 5600 & 5600 Econominder - page 36

    P/N 40106 Rev . H 05/05 ...

Fabricante Pentair Categoría Water Dispenser

Los documentos del dispositivo Pentair Model 5600 & 5600 Econominder que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Pentair
- manuales de instrucciones Model 5600 & 5600 Econominder
- hojas de producto Pentair
- folletos informativos
- o etiquetas energéticas Pentair Model 5600 & 5600 Econominder
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Pentair Model 5600 & 5600 Econominder.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Pentair Model 5600 & 5600 Econominder, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Pentair Model 5600 & 5600 Econominder. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Pentair Model 5600 & 5600 Econominder.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Pentair Model 5600 & 5600 Econominder, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Pentair Model 5600 & 5600 Econominder. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Pentair Model 5600 & 5600 Econominder.

El manual de instrucciones completo de Pentair debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Pentair Model 5600 & 5600 Econominder - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Pentair Model 5600 & 5600 Econominder, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Pentair Model 5600 & 5600 Econominder que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Pentair Model 5600 & 5600 Econominder - que deben facilitarnos los primeros pasos durante el uso de Pentair Model 5600 & 5600 Econominder
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Pentair Model 5600 & 5600 Econominder
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Pentair Model 5600 & 5600 Econominder en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Pentair Model 5600 & 5600 Econominder?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Pentair Model 5600 & 5600 Econominder, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Pentair Model 5600 & 5600 Econominder probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)