    Report No. 317-S-05-5 IN ST AL LA TI ON AN D OP ER A TIO N IN ST RU CT IO NS Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not light any appliance. • Do not touch any electrical switches; do not use any phone in your building. • Immediately ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 2

    2 1. 0 I MP OR T AN T SA F ET Y AN D W ARN I NG IN F OR MA T IO N W ARNINGS If th e info rma tio n in this manu al is not fol- low ed e xac tly , a fi re or exp los ion may res ult cau sin g pro per ty dama ge, pers ona l inj ury or los s o f li fe. IMPOR T ANT Rea d and un der stan d the se ins tru ctio ns com ple tel y bef ore inst alli ng or op ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 3

    3 2.0 GENERAL INFORMA TION This appliance is a high efficiency , unvented, flame effect gas heater . It provides radiant and convected warmth both efficiently and safely utilizing the latest type catalytic convertor burner technology . The appliance does not require a flue system of any type as the catalytic converter cleans the flue products ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 4

    4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE THE FOLLOWING BOXED INFORMA TION APPLIES TO REQUIRE- MENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS. Note: The following requirements reference various Massachusetts and national codes not contained in this document. Unvented Room Heaters shall be installed in accordance with 527 CMR 30.00 and 24 ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 5

    5 7.0 COMBUSTION AND VENTILA TION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventil ation air . The heater may be located in unusually tight construction provided the space is unconfined, or if confined, is provided with two permanent openi ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 6

    6 8.0 SITE REQUIREMENTS This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall. This appliance may be installed in any room in a home except bedrooms or bathrooms - or areas where large amounts of steam are likely to be generated. It should be noted that heaters create warm air currents. These currents mov ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 7

    7 After having selected the final mounting position of the appliance, taking into account the site requirem ents as specifie d in Section 8 of these instr uc- tions, the integrity of the wall, and the feasibility of the proposed supply pipe routing, the firebox of appliance may be secured to the wall. T o ensure customer safety , be sure to desi ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 8

    8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE Insert the wall mounting screws into the top wall plugs, taking care to leave the screws protruding approximately 3/8” from the wall. Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance. Insert the lower mounting screws into the low ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 9

    9 13.0 CHECKING THE GAS CONNECTIONS T urn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bubble leak solution). NOTE: using a soapy water solution (50% dish soap, 50% water) is an effective leak test solution, but it is not recommended, because the soap residue that is left on the pipes/fittings can result ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 10

    10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 15.0 SP ARK GAP The gap between the spark electrode and the pilot should be 1/8” to 3/16” to produce a good spark. There should be no need to adjust this. If under any circumstances the piezo electric spark fails, the pilot cannot be lit manually . 16.0 ASSEMBL Y OF THE GLASS FACIA Figure ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 11

    11 5. Secure the grill in position using two M6 screws and two no. 8 self tapping screws as shown in Figure 14 . 17.0 FITTING THE GLASS F ACIA The glass facia panel is supported by four M6 screws which protrude from the front of the outer casing. Insert the M6 retaining screws and ensure they are unscrewed approximately 1/8” so the keyhole shaped ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 12

    12 19.0 BRIEFING THE CUSTOMER W ARNING Do not add log s or orn amen ts such as pine con es, ver mic uli te or roc k woo l. Usi ng the se add ed ite ms can ca use soo tin g. All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire. Show the customer how to remove and replace the glass facia. A ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 13

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 13 Clean the pilot assembly with a soft brush and blow through. Check the aeration holes are free of any dirt or lint. Clean thoroughly internally , the connection can be removed from the base of the pilot unit using two spanners to make cleaning easier . Do not damage or try to dismantle the pil ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 14

    14 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lit with a piezo spark igniter . When lighting the pilot, follow these instructions exactly . B. BEFORE OPERA TING ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 15

    15 27.0 TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections. • Air not fully purged. Purge supply or wait longer . • Spark grounding to metal work, reset gap correctly . • Blocked pilot, clean out internally . Pilot lights but then goes out • Severe rest ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 16

    16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE Figure 22 Figure 21 29.0 POSITIONING OF FIELD REMOV ABLE P ARTS W ARNING Fai lur e to pos itio n the part s in acc orda nce with the se diag rams or fail ure to use only part s sp ecifi cal ly appr ove d wit h t his hea ter ma y re sul t i n p rop ert y da mag e o r pe rso nal inj ury . Visua ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 17

    17 30.0 NOTES ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 18

    18 Printed in U.S.A. © Lennox Hearth Products 2007 P/N 850,055M REV . A 12/2007 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. 1110 West T aft Avenue • Orang ...

Fabricante Lennox Hearth Categoría Electric Heater

Los documentos del dispositivo Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lennox Hearth
- manuales de instrucciones Catalytic Vent-Free Wall Mounted Gas FirePlace
- hojas de producto Lennox Hearth
- folletos informativos
- o etiquetas energéticas Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace.

El manual de instrucciones completo de Lennox Hearth debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - que deben facilitarnos los primeros pasos durante el uso de Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)