    1-800-K EA TI NG www .keatingofchicago.com Users Manual I N ST ANT R E CO VE R Y ® GAS FR YE R SERIES 2 0 0 9 R EAD AN D SA VE TH I S MAN U AL F OR FUTUR E R E FE R E NCE. Keep this manual for training new personnel. I M PORT ANT SAFETY I N STR UCTION S . . . . . . . . . . . . . . . . i I NTROD U C TI ON . . . . . . . . . . . . . . . . . . . . . . ...

  • Keating Of Chicago Fryer - page 2

    i W A RNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. FOR Y OU R S A FETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of ...

  • Keating Of Chicago Fryer - page 3

    INTRODUCTION Instructions in this manual should be read thor oughly before attempting to operate this Keating Gas Fryer . All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel. Operating information for Keating equipment has been prepar ed for use by ...

  • Keating Of Chicago Fryer - page 4

    operation. Air for combustion enters the fryer from the bottom of the cabinet and the bottom of the control panel. DO NOT BLOCK BOTTOM OF KEA TING INST ANT RECOVER Y ® GAS FR YER CABINET . DO NOT OBSTRUCT FLUE. Y our Keating Instant Recovery ® Gas Fryer is designed to be serviced from the fr ont. MINIMUM CLEARANCE MINIMUM CLEARANCE SUIT ABLE FOR ...

  • Keating Of Chicago Fryer - page 5

    3 FLEXIBLE GAS CONNECTORS AND QUICK DISCONNECT DEVICES For an appliance equipped with casters: The installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or the Standard for Connectors for Moveable Gas Appliances, CAN/CGA-6.16, and a quick disconnect device that complies wi ...

  • Keating Of Chicago Fryer - page 6

    4 FILLING NOTE: Before filling the fryer make certain the fryer vessel is sanitized, dry and the drain valve is completely closed. NOTE: Solid shortening can not be used in a Keating Model AA Gas Fryer . If solid shortening is used, it should be melted prior to filling the fryer vessel. Damage done by melting solid shortening in the fryer vessel wi ...

  • Keating Of Chicago Fryer - page 7

    5 SERIES 2000 BB MODELS OPERA TING INSTRUCTIONS BB CONTROL P ANEL – SERIES 2000 ST AR T -UP PROCEDURE WARNING: DO NOT ST AR T FRYER WITHOUT FIRST FILLING FR Y POT . STEP 1. Set "MEL T -IDLE-FR Y" switch to "IDLE" position and thermostat to the "OFF" position. STEP 2. T urn "MAIN POWER" switch to the "O ...

  • Keating Of Chicago Fryer - page 8

    6 SERIES 2000 TS MODELS OPERA TING INSTRUCTIONS TS CONTROL P ANEL – SERIES 2000 ST AR T -UP PROCEDURE WARNING: DO NOT ST AR T FRYER WITHOUT FIRST FILLING FR Y POT . STEP 1. Set "MEL T -IDLE-FR Y" switch to "IDLE" position and thermostat to the "OFF" position. STEP 2. T u r n "MAIN POWER" switch to "ON& ...

  • Keating Of Chicago Fryer - page 9

    7 Select "MEL T" with solid shortening until liquid shortening is 1" from full mark then switch to the "FR Y" position after packing shortening around burner tubes. SHUTDOWN PROCEDURE STEP 1. Set thermostat to the "OFF" position. STEP 2. T urn "MAIN POWER" switch to the "OFF" position. Its gree ...

  • Keating Of Chicago Fryer - page 10

    OPERA TION OF THIS FR YER SHOULD BE LIMITED TO PERSONNEL WHO HA VE BEEN THOROUGHL Y TRAINED IN OPERA TING PROCEDURES. CARE SHOULD BE T AKEN WHEN LOWERING BASKETS INTO FR YER TO PREVENT SPLASHING HOT OIL FROM FR YER VESSEL. If your fryer has timers, push the “ T1, ” “ T2 ” or “ T3 ” button on the digital timer(s). For fryers with automat ...

  • Keating Of Chicago Fryer - page 11

    9 1. Operator should be outfitted with proper attir e including: •Oil and heat resistant gloves •Oil and heat resistant apr on •Safety goggles •Oil and heat resistant footwear 2. T urn off the fryer and open the door . 3. Put suitable container under drain valve. 4. Drain oil from fryer by slowly turning handle. The drain will be completely ...

  • Keating Of Chicago Fryer - page 12

    SAFE & EASY FIL TER (SIDE VIEW) A KEA TING FR YER OR FIL TER SHOULD BE DRAINED ONL Y UNDER THE SUPERVISION OF PROPERL Y TRAINED PERSONNEL. WHEN DISCARDING OIL, A COVERED RECEPT ACLE APPROVED FOR USE WITH HOT OIL SHOULD BE USED. USE OF A NON-APPROVED RECEPT ACLE OR METHOD OF DRAINING THE OIL COULD JEOP ARDIZE THE SAFETY OF THE OPERA TOR. 1.Opera ...

  • Keating Of Chicago Fryer - page 13

    11 OPERA TOR SELF HELP Before calling for service, r eview this list. It may save you both time and expense. This list includes common occurrences that ar e not the result of defective workmanship or materials in this appliance. NOTE : For a fryer with a Central Filter or Safe & Easy ® Filter always check the rear drain operating handle before ...

  • Keating Of Chicago Fryer - page 14

    Thermostat Bulb Positioning 10×11, 18 & larger Fryer Gas DO NOT ADJUST THERMOST A T SET SCREW - IT VOIDS ANY WARRANTY ON P AR T W ARRANTY REP AIRS Keating's warranty begins with the date of installation. In the event that your Fryer , under warranty , needs repairs other than r outine cleaning, you are r equired to contact KEA TING OF CHI ...

  • Keating Of Chicago Fryer - page 15

    13 PROBLEM PROBABLE CAUSE SOLUTION Constant pilot won’t light. a. Gas isn’t turned on. b. Clogged constant pilot tubing. c. Constant pilot valve isn’t turned on. a. T urn manual gas valve on. If using flexible connector with quick disconnect, make sure quick disconnect is completely engaged. b. T urn fryer and manual gas valve off. Clean tubi ...

  • Keating Of Chicago Fryer - page 16

    Burners will not light. a. Gas valve knob in incorrect position (AA & CMG models). b. Switch not set to fry (BB & TS models). c. Thermostat is faulty . d. Fry/Off/Melt switch (BB & TS models) or On/Off switch (AA & CMG models) is faulty . e. Faulty gas valve. a. Rotate gas valve knob to ON. T urn power switch ON. Set thermostat to d ...

  • Keating Of Chicago Fryer - page 17

    TROUBLESHOOTING CHAR T (continued) Flames come out top of flue. a. Excessive gas supply or pressur e. b. Collapsed burner radiants. c. Exhaust problems. a. Adjust pressur e, change bur ner orifices or install in-line regulator . b. Replace radiants. c. Install or adjust flue restrictors. If problem persists, contact your HV AC repr esentative. Flam ...

  • Keating Of Chicago Fryer - page 18

    P AR TS LIST ORDERING P ARTS Parts may be order ed by part number by calling Keating at 1-800-KEA TING or your local service company . Y ou may also order online at Keating’ s part stor e, www .keatingofchicago.com. Refer to the limited warranty in this manual for complete service and ordering information. The model/serial plate is located on the ...

  • Keating Of Chicago Fryer - page 19

    17 GAS FR YER ASSEMBL Y T op & Side Views Front View Door Catch, Magnet (Series 2000 to 1 1/2001) T op & Side Views Front View Door Catch, Magnet (Series 2001 to current) Item # 22 ...

  • Keating Of Chicago Fryer - page 20

    18 SERIES 2000 - 2005 RUNNER PILOT ASSEMBL Y (S park Ignition Models - See p age 27) ...

  • Keating Of Chicago Fryer - page 21

    19 SERIES 2005-2009 RUNNER PILOT ASSEMBL Y (S park Ignition Models - See p age 27) 2 3 10 6 Locknut 6 7 8 14 3 6 10 Locknut 6 7 8 14 2 3 10 10 Locknut 6 7 8 14 12 12 14 8 7 6 Locknut 11 to Gas V alve to Gas V alve 10 10 Locknut Locknut 3 6 6 7 7 8 11 14 8 10 10 6 11 14 9 3 14 14 11 Locknut 6 7 8 Models: Series 2005 10x11, 14AA & CMG Models: Ser ...

  • Keating Of Chicago Fryer - page 22

    CONTROL P ANEL AA & CM GAS – SERIES 2006 C T O 250 275 350 H R B I L A S E T A I D F I T L A 375 300 325 OFF ON POWER QTY . DESCRIPTION P/N A 1 THERMOST A T DIAL PLA TE 250º-375°F 058037 B 1 THERMOST A T KNOB 004163 C 1 GAS FR YER THERMOST A T 14AA & 14CM 023145 10×11, 18 & Lar ger 035553 D 1 SWITCH ROCKER WHITE ON/OFF 035030 E 1 H ...

  • Keating Of Chicago Fryer - page 23

    J G H D A B, C CONTROL P ANEL BB GAS – SERIES 2000 Control Panel Fr ont Back Panel 21 QTY . DESCRIPTION P/N A 1 THERMOST A T DIAL PLA TE 250°-375ºF 058037 B 1 THERMOST A T KNOB 004163 C 1 GAS FRYER THERMOST A T 14 ” BB, TS, IFM, CPU 035574 10x11, 18 ” and Lar ger 035575 D 1 SWITCH MEL T -IDLE-FR Y 032829 E1 HIGH LIMIT (RESETT ABLE) contact ...

  • Keating Of Chicago Fryer - page 24

    22 C T O 250 275 350 H R B I L A S E T A I D F I T L A 3 75 300 325 FRY OFF ON ON POWER POWER MEL T CONTROL P ANEL BB SP ARK IGNITION - SERIES 2006 Control Panel Fr ont Back Panel - Rear Drain Unit QTY . DESCRIPTION P/N A 1 THERMOST A T DIAL PLA TE 250°-375ºF 058037 B 1 THERMOST A T KNOB 004163 C 1 GAS FR YER THERMOST A T 14 ” BB, TS, IFM, CPU ...

  • Keating Of Chicago Fryer - page 25

    23 CONTROL P ANEL TS GAS - SERIES 2000 QTY . DESCRIPTION P/N A 1 THERMOST A T DIAL PLA TE 250°F 058037 B 1 THERMOST A T KNOB 004163 C 1 GAS FRYER THERMOST A T 14 ” BB, TS, IFM, CPU 035574 10x11, 18 ” & Lar ger 035575 D 1 SWITCH ROCKER WHITE 058328 E 2 DIGIT AL TIMER 24V 056921 F 1 SWITCH MEL T -IDLE-FR Y 032829 G 1 INDICA TING LIGHT GREEN ...

  • Keating Of Chicago Fryer - page 26

    QTY . DESCRIPTION P/N A 1 SWITCH TOGGLE POWER 059141 B 1 LIGHT INDICA TING ROUND - CLEAR 057863 C 1 SWITCH TOGGLE PILOT 059142 D 1 LIGHT INDICA TING ROUND - AMBER 056588 E 1 SWITCH TOGGLE MEL T - FRY 059143 F 1 LIGHT INDICA TING ROUND - GREEN 056587 G 1 LIGHT INDICA TING ROUND - RED 057861 H 2 TIMER DIGIT AL 24V 056921 I 1 THERMOST A T 035575 J 1 T ...

  • Keating Of Chicago Fryer - page 27

    25 CONTROL P ANEL TS SP ARK IGNITION - SERIES 2007 FOR 34 X 24 MODEL, SERIES 2009 FOR ALL OTHER MODELS QTY . DESCRIPTION P/N A 1 SWITCH TOGGLE POWER 059141 B 1 INDICA TING LIGHT CLEAR 057863 C 1 SWITCH TOGGLE MEL T -FRY 059143 D 1 INDICA TING LIGHT GREEN 056587 E 1 INDICA TING LIGHT RED 057861 F 2 DIGIT AL TIMER 24V 056921 G 1 THERMOST A T 035575 H ...

  • Keating Of Chicago Fryer - page 28

    26 CPU CONTROL P ANEL SERIES 2007 CPU CONTROL P ANEL SERIES 2010 Control Panel Fr ont Control Panel Fr ont A B C D E Back Panel - Front Drain Unit Back Panel - Front Drain Unit I F G H J Back Panel - Rear Drain Unit Back Panel - Rear Drain Unit F J K O L M I N QTY . DESCRIPTION P/N A 1 SWITCH ROCKER WHITE ON/OFF 035030 B 1 SWITCH ROCKER WHITE MOMEN ...

  • Keating Of Chicago Fryer - page 29

    Design V alid Appr ox. Sept. 2004 - Current QTY . DESCRIPTION P/N A 1 SP ARK IGNITION ELECTRODE 030253 B 1 RUNNER PILOT TUBE 10×11 021656 14 ” 028828 18 ” 021658 20 ” 021730 24 ” 037623 34×24 C* 1 SP ARK IGNITION MODULE 058439 *Not Shown A B 27 SP ARK IGNITION DESIGN V ARIA TIONS Design V alid Appr ox. Feb. 2002- Sept. 2004 QTY . DESCRIPT ...

  • Keating Of Chicago Fryer - page 30

    28 DESCRIPTION QTY P AR T # 1 TRANSFORMER 120/208/240/480V 1 056036 2 CIRCUIT BREAKER 3A/250V 1 053338 3 RELA Y DPDT 24V AC 2 030844 4 RECTIFIER 1 018321 5 POWER CORD 1 021289 6 CONNECTION 3 CIRCUITS PLUG 1 032210 7 CONNECTOR 2 CIRCUIT CAP 2 032207 8 COVER FOR CIRCUIT BREAKER 1 054664 9 PUSH ROD 1 018096 10 SCREW 1 / 4 "-20" X 1 1 / 4 &qu ...

  • Keating Of Chicago Fryer - page 31

    29 DESCRIPTION QTY P AR T # 1 TRANSFORMER STEPDOWN 24VAC 100V A 1 058359 2 RELA Y DPDT 24V AC 2 030844 RELA Y DPDT 24V AC (CPU MODEL) 2 017673 3 RECTIFIER 24VDC 1 018321 4 BUSHING STRAIN RELIEF 5 / 8 ” HOLE 2 000470 5 BUSHING STRAIN RELIEF 3 / 4 ” HOLE 1 033800 *Circuit br eaker is located under the control panel BASKET LIFT POWER SUPPL Y BOX 2 ...

  • Keating Of Chicago Fryer - page 32

    30 ELECTRICAL BOX ASSEMBL Y GAS FR YER (TS and BB ONL Y) 2000 SERIES QTY . DESCRIPTION P/N A 1 TRANSFORMER 120V/240V TO 24V 024032 B 1 2 PIN CONNECTOR 032207 C 1 9 PIN CONNECTOR 028303 D 1 F A T MEL T 24V 037470 D A C B ...

  • Keating Of Chicago Fryer - page 33

    31 CM & AA 2000 ELECTRICAL ASSEMBL Y FRONT DRAIN SEE INSIDE FR YER DOOR FOR CURRENT WIRING DIAGRAMS COMPONENT CODES: P – POWER SWITCH TH – THERMOSTAT HL – HIGH LIMIT AA 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER ...

  • Keating Of Chicago Fryer - page 34

    32 BB 2000 ELECTRICAL ASSEMBL Y AA 2010 ELECTRICAL ASSEMBL Y FRONT DRAIN ...

  • Keating Of Chicago Fryer - page 35

    33 BB 2006 ELECTRICAL ASSEMBL Y Electrical Assembly not shown to scale BB 2000 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER ...

  • Keating Of Chicago Fryer - page 36

    34 BB 2006 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER 34 X 24 BB 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN ...

  • Keating Of Chicago Fryer - page 37

    35 34 X 24 BB 2008 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER 34 X 24 BB 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER ...

  • Keating Of Chicago Fryer - page 38

    36 Electrical Assembly not shown to scale TS 2000 ELECTRICAL ASSEMBL Y BB 2006 SP ARK IGNITION WITH SAFE & EASY ® FIL TER ...

  • Keating Of Chicago Fryer - page 39

    37 TS 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN TS 2000 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER ...

  • Keating Of Chicago Fryer - page 40

    38 TS 2007 ELECTRICAL ASSEMBL Y BASKET LIFT FRONT DRAIN TS 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER ...

  • Keating Of Chicago Fryer - page 41

    39 TS 2007 ELECTRICAL ASSEMBL Y SP ARK IGNITION FRONT DRAIN TS 2009 ELECTRICAL ASSEMBL Y BASKET LIFT FRONT DRAIN ...

  • Keating Of Chicago Fryer - page 42

    40 TS 2007 ELECTRICAL ASSEMBL Y SP ARK IGNITION WITH SAFE & EASY ® FIL TER TS 2009 ELECTRICAL ASSEMBL Y BASKET LIFT FRONT DRAIN ...

  • Keating Of Chicago Fryer - page 43

    41 34 X 24 TS 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN 34 X 24 TS 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN ...

  • Keating Of Chicago Fryer - page 44

    42 34 X 24 TS 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER 34 X 24 TS 2008 AND ALL TS MODELS 2009 ELECTRICAL ASSEMBL Y FRONT DRAIN ...

  • Keating Of Chicago Fryer - page 45

    43 34 X 24 TS 2007 AND ALL TS MODELS 2009 ELECTRICAL ASSEMBL Y SP ARK IGNITION WITH SAFE & EASY ® FIL TER 34 X 24 TS 2008 AND ALL TS MODELS 2009 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER ...

  • Keating Of Chicago Fryer - page 46

    44 CPU 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER CPU 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN ...

  • Keating Of Chicago Fryer - page 47

    45 CPU 2007 ELECTRICAL ASSEMBL Y SP ARK IGNITION WITH SAFE & EASY ® FIL TER CPU 2007 ELECTRICAL ASSEMBL Y SP ARK IGNITION FRONT DRAIN ...

  • Keating Of Chicago Fryer - page 48

    46 BASKET LIFT ELECTRICAL ASSEMBL Y NON-CPU MODELS SERIES 2007 BASKET LIFT ELECTRICAL ASSEMBL Y PRE 2007 (ALL FRYERS) ...

  • Keating Of Chicago Fryer - page 49

    47 BASKET LIFT ELECTRICAL ASSEMBL Y WITH CPU MODELS SERIES 2007 ...

  • Keating Of Chicago Fryer - page 50

    ...

  • Keating Of Chicago Fryer - page 51

    ...

  • Keating Of Chicago Fryer - page 52

    KEA TI N G LI M ITE D W AR RANTY C AR D PLEASE CO M PLETE AND MAI L A T O NCE–WARR ANTY IS N O T I N EF FECT U NTIL CAR D IS R ETU R NE D. W AR RANTY CAR D IS AL SO AV AI LABLE T O C OM PLETE ON LI NE A T YOU R CO NVEN I E NC E. CO M P ANY: ___________________________________________________________________________________________________________ ...

Fabricante Keating Of Chicago Categoría Fryer

Los documentos del dispositivo Keating Of Chicago Fryer que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Keating Of Chicago
- manuales de instrucciones Fryer
- hojas de producto Keating Of Chicago
- folletos informativos
- o etiquetas energéticas Keating Of Chicago Fryer
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Keating Of Chicago Fryer.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Keating Of Chicago Fryer, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Keating Of Chicago Fryer. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Keating Of Chicago Fryer.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Keating Of Chicago Fryer, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Keating Of Chicago Fryer. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Keating Of Chicago Fryer.

El manual de instrucciones completo de Keating Of Chicago debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Keating Of Chicago Fryer - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Keating Of Chicago Fryer, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Keating Of Chicago Fryer que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Keating Of Chicago Fryer - que deben facilitarnos los primeros pasos durante el uso de Keating Of Chicago Fryer
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Keating Of Chicago Fryer
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Keating Of Chicago Fryer en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Keating Of Chicago Fryer?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Keating Of Chicago Fryer, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Keating Of Chicago Fryer probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)