Manual de instrucciones Desa (V)V42PA(1)

42 de páginas 2.53 mb
Descargar

Pasar a la página of 42

Summary
  • Desa (V)V42PA(1) - page 1

    FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. WARNING: ...

  • Desa (V)V42PA(1) - page 2

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 2 SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/ ...

  • Desa (V)V42PA(1) - page 3

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching. 6. Carefully super ...

  • Desa (V)V42PA(1) - page 4

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 4 PRODUCT FEA TURES These are a few facts that can help you understand and enjoy your direct-vent fireplace: • The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to ...

  • Desa (V)V42PA(1) - page 5

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 CLEARANCES Minimum clearances to combustibles for the fireplace are as follows: Back, and sides 0"/mm Perpendicular walls 6" (152mm) Floor 0"/mm Ceiling to louver opening 42" (1067mm) Front 36" (914mm) Top of Standoffs 0 ...

  • Desa (V)V42PA(1) - page 6

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 6 Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porc ...

  • Desa (V)V42PA(1) - page 7

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 These models are tested and approved for use with DESA (direct- vent) pipe components and terminations. The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate soli ...

  • Desa (V)V42PA(1) - page 8

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 8 INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal T ermination • V ertical T ermination Horizontal Termination Installation IMPORTANT: Horizontal square terminations require only inner portion of wall fi ...

  • Desa (V)V42PA(1) - page 9

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 WARNING: Do not recess vent termination into any wall. This will cause a fire hazard. 6. Noncombustib le Exterior Wall: Position the horizontal vent cap in the center of the 8 1 / 2 " round hole and attach to the exte- rior wall with four w ...

  • Desa (V)V42PA(1) - page 10

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 10 Horizontal High Wind Square Termination Wall Firestop 45 ° Elbow Figure 14 - Horizontal Termination Configuration for Square or Round Terminations 45 ° Elbow Wall Firestop Horizontal Round Termination Exterior Portion of Wall Firestop (Round Te ...

  • Desa (V)V42PA(1) - page 11

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 Figure 15 - Horizontal Termination Configuration for Corner Installation Using One 90 ° Elbow Square Termination Wall Firestop Not to Exceed (H) Limits As Required for (V) See Chart for Pipe Section Required 45 ° Elbow 90 ° Elbow 90 ° Elbo ...

  • Desa (V)V42PA(1) - page 12

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 12 V enting with T wo 90 ° Elbo ws V ertical (V) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. 20' max. 20' max. Figure 18 - Horizontal Ter ...

  • Desa (V)V42PA(1) - page 13

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 INSTALLATION FOR VERTICAL TERMINATION Note: Vertical restrictor must be installed in all vertical installations. 1. Determine the route your vertical venting will take. If ceiling joists, roof rafters, or other framing will obstruct the ventin ...

  • Desa (V)V42PA(1) - page 14

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 14 VENTING INST ALLA TION INSTRUCTIONS Continued Vertical Termination Configurations Figures 21 through 24 show four different configurations for verti- cal termination. V enting with T wo 90 ° Elbo w s V ertical (V) Horizontal (H 1 ) + Horizontal ...

  • Desa (V)V42PA(1) - page 15

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 VENTING INST ALLA TION INSTRUCTIONS Continued V er tical V enting V = 40' max. Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown) Note: Install restrictor into inner collar of fi ...

  • Desa (V)V42PA(1) - page 16

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 16 01507 Storm Collar - Galvanized (4) 01508 Wall Strap (4) 01514 Combustible Siding Standoff - Galvanized (1) 01607 Wall Firestop - Galvanized (4) VR-58 Vertical Restrictor - Galvanized VENTING INST ALLA TION INSTRUCTIONS Continued VENTING INSTALLA ...

  • Desa (V)V42PA(1) - page 17

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 . FIREPLACE INST ALLA TION Model BK Installation Follow all instructions provided in the blower accessory kit. 1. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two sp ...

  • Desa (V)V42PA(1) - page 18

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 18 9. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. T urn blower on and check for operation. T urn blower off by turning knob fully counterclockwise before ...

  • Desa (V)V42PA(1) - page 19

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 FIREPLACE INST ALLA TION Continued FIREPLACE INSTALLATION Installing Optional Blower Accessories (Cont.) Installing Gas Piping to Fireplace Location Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models Blower Wiring Diagram CAUTI ...

  • Desa (V)V42PA(1) - page 20

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 20 Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage firep ...

  • Desa (V)V42PA(1) - page 21

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 FIREPLACE INST ALLA TION Continued FIREPLACE INSTALLATION Checking Gas Connections (Cont.) Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 33). 2. Pressurize supply piping system by either o ...

  • Desa (V)V42PA(1) - page 22

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 22 FIREPLACE INST ALLA TION Continued FIREPLACE INSTALLATION Installing Optional Wireless Hand-Held Remote Control - RC, (C)GHRCB, (C)GHRCTB Series Installing Remote Receiver 1. Open bottom louver and locate the switch bracket on the left. 2. Unscre ...

  • Desa (V)V42PA(1) - page 23

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 Lock Unlock FIREPLACE INST ALLA TION Continued FIREPLACE INSTALLATION Removing/Replacing Glass Door Installing Optional Brick Liner Models BL42DA(SA) and BL42DHA(SA) REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this fireplace with a b ...

  • Desa (V)V42PA(1) - page 24

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 24 FIREPLACE INST ALLA TION Continued FIREPLACE INSTALLATION Installing Optional Brick Liner Models BL42D(S) and BL42DH(S) (Cont.) Installing Logs, Lava Rock and Glowing Embers Figure 43 - Installing Rear Brick Panel Figure 44 - Installing Left Side ...

  • Desa (V)V42PA(1) - page 25

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 FIREPLACE INSTALLATION Installing Logs, Lava Rock and Glowing Embers (Cont.) FIREPLACE INST ALLA TION Continued WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or b ...

  • Desa (V)V42PA(1) - page 26

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 26 OPERA TING FIREPLACE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting t ...

  • Desa (V)V42PA(1) - page 27

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 OPERA TING FIREPLACE Continued OPTIONAL HAND-HELD REMOTE OPERATION OPERATING FIREPLACE Optional Hand-Held Remote Operation O F F P I L O T O N L O I H ON OFF REMOTE ON OFF Blower Control Knob (Optional Accessory) Variable Control Knob Selector ...

  • Desa (V)V42PA(1) - page 28

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 28 OPERATING FIREPLACE Optional Hand-Held Remote (Cont.) Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower Accessory INSPECTING BURNERS Pilot Assembly Burner Flame Pattern OPERA TING FIREPLACE Continued OPERATING OPTIONAL BL ...

  • Desa (V)V42PA(1) - page 29

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 CLEANING AND MAINTENANCE Glass Door Pilot and Burners Logs Venting System PILOT AND BURNERS • Remove ember material before cleaning burners and replace when cleaning is complete. • Burner and controls should be cleaned with compressed air ...

  • Desa (V)V42PA(1) - page 30

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 30 TROUBLESHOOTING TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a quali- fied service person should service and repair heater. CAUTION: Never use a wir ...

  • Desa (V)V42PA(1) - page 31

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Glass soots Fireplace prod ...

  • Desa (V)V42PA(1) - page 32

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 32 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neigh ...

  • Desa (V)V42PA(1) - page 33

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 33 33 (V)V42NA(1) CHDV42NRA (V)V42PA(1) Btu 25,000/ 25,000/ 23,000/ 35,000 Btu/hr 35,000 Btu/hr 33,000 Btu/hr Gas Type Natural Natural Propane/LP Ignition Piezo Piezo Piezo Manifold Pressure 3.5" w.c. 3.5" w.c. 10.0" w.c. Minimum Inle ...

  • Desa (V)V42PA(1) - page 34

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 34 6 7 21 18 19 14 13 2 12 20 8 1 4 11 9 15 3 17 16 5 10-2 10-1 10-5 10-4 10-3 10-7 16 22 10-6 ILLUSTRATED PARTS BREAKDOWN (V)V42NA(1), (V)V42NSA(1), (V)V42NHA(1), (V)V42PA(1), (V)V42PSA(1), (V)V42PHA(1), CHDV42NRA ILLUSTRA TED P AR TS BREAKDOWN (V) ...

  • Desa (V)V42PA(1) - page 35

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 35 35 REFRACTORY BRICK PANELS V42NSA(1) VV42NSA(1) CHDV42NRA VV42NHA(1) V42PSA(1) VV42PSA(1) V42NHA(1), V42PHA(1) VV42PHA(1) DESCRIPTION QTY 111299-02 111299-01 111302-02 111302-01 Left Refractory Brick Panel 1 111297-02 111297-01 111300-02 111300-0 ...

  • Desa (V)V42PA(1) - page 36

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 36 ILLUSTRA TED P AR TS BREAKDOWN BURNER ASSEMBLY FOR MODELS (V)V42NA(1), (V)V42NSA(1), (V)V42NHA(1), (V)V42PA(1), (V)V42PSA(1), (V)V42PHA(1), CHDV42NRA ILLUSTRATED PARTS BREAKDOWN Models (V)V42NA(1), (V)V42NSA(1), (V)V42NHA(1), (V)V42PA(1), (V)V42P ...

  • Desa (V)V42PA(1) - page 37

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 37 37 P ARTS LIST BURNER ASSEMBLY FOR MODELS (V)V42NA(1), (V)V42NSA(1), (V)V42NHA(1), (V)V42PA(1) (V)V42PSA(1), (V)V42PHA(1), CHDV42NRA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed ...

  • Desa (V)V42PA(1) - page 38

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 38 ACCESSORIES Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESA’s Sales Department at 1-866-672-6040. for information. You can also write to the address listed on the back page of t ...

  • Desa (V)V42PA(1) - page 39

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 39 39 ACCESSORIES 1. Where will the product be used? ❍ Living/F amily Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Gar age ❍ Bedroom ❍ Bathroom ❍ Other 2. If you bought this product yourself , did you plan to purchase this type ...

  • Desa (V)V42PA(1) - page 40

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 40 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required T APE T APE ...

  • Desa (V)V42PA(1) - page 41

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 41 41 NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________ ...

  • Desa (V)V42PA(1) - page 42

    111906-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 42 LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintaine ...

Fabricante Desa Categoría Indoor Fireplace

Los documentos del dispositivo Desa (V)V42PA(1) que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Desa
- manuales de instrucciones (V)V42PA(1)
- hojas de producto Desa
- folletos informativos
- o etiquetas energéticas Desa (V)V42PA(1)
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Desa (V)V42PA(1).

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Desa (V)V42PA(1), instrucciones de servicio, instrucciones cortas o instrucciones de usuario Desa (V)V42PA(1). Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Desa (V)V42PA(1).

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Desa (V)V42PA(1), ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Desa (V)V42PA(1). Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Desa (V)V42PA(1).

El manual de instrucciones completo de Desa debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Desa (V)V42PA(1) - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Desa (V)V42PA(1), preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Desa (V)V42PA(1) que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Desa (V)V42PA(1) - que deben facilitarnos los primeros pasos durante el uso de Desa (V)V42PA(1)
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Desa (V)V42PA(1)
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Desa (V)V42PA(1) en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Desa (V)V42PA(1)?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Desa (V)V42PA(1), haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Desa (V)V42PA(1) probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)