Manual de instrucciones York LD11556

12 de páginas 0.83 mb
Descargar

Pasar a la página of 12

Summary
  • York LD11556 - page 1

    LD1 1555 INST ALLA TION, OPERA TION, & MAINTENANCE F AN COIL AIR CONDITIONERS NEW RELEASE Form 1 15.20-NOM6 (1 106) ***** W ARNING TO INST ALLER, SERVICE PERSONNEL AND OWNER ***** Altering the product or replacing parts with non-authorize d factory parts voids all warranty or implied warranty and may result in adverse operational performance an ...

  • York LD11556 - page 2

    JOHNSON CONTROLS 2 FORM 1 15.20-NOM6 (1 106) T ABLE OF CONTENTS FIG. 2 – PHYSICAL DIMENSIONS (INCHES) Reference Documents: • Parts List, Fan Coil Air Conditioners Form 1 15.20-RP2 (Latest) These documents can be ordered through Publications Dept. or downloaded @ http://intranet.york.com/web0003/ library/default.asp F D C B 2 1.75 A DRAIN KNOCKO ...

  • York LD11556 - page 3

    3 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) INST ALLA TION RECEIVING Material in this shipment has been inspected at the factory and released to the transportation agency in good condition. When received, a visual inspect ion of all carton s shoul d be ma de imme diatel y . An y evid ence of rough handlin g or app arent damage should be note d on ...

  • York LD11556 - page 4

    JOHNSON CONTROLS 4 FORM 1 15.20-NOM6 (1 106) INST ALLA TION 2 . Frame around the perimeter of the unit as required for securing the drywall. See T able 1 below for drywall openings. 3. Mo unt the un it in its perma nent locat ion, maki ng sure it is level to insure proper drainage and operation (two 1/2” holes have been provided on each end of th ...

  • York LD11556 - page 5

    5 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) INST ALLA TION DUCTWORK Ductwork recommendations are as follows: • Insulate to prevent condensation during cooling. • Size to the unit openings are generally ac cept abl e bu t ar e de ter mine d by the eng ine erin g drawings. • Be sure units are ducted per local codes or national codes, as applic ...

  • York LD11556 - page 6

    JOHNSON CONTROLS 6 FORM 1 15.20-NOM6 (1 106) T able 2 - ELECTRICAL DA T A UNIT MODEL KW TOT AL AMPS MIN. CIR. AMP ACITY MAX.OVERCURRENT PROTECTION 240V 208V 240V 208V 240V 208V 240V 208V 4CWE 0 0 0.0 1.1 N/A N/A N/A N/A N/A 1 1 0.8 5.3 4.7 7 6 15 15 2 2 1.5 9.4 8.3 12 1 1 15 15 3 3 2.3 13.6 1 1.9 17 15 20 15 4 4 3.0 17.8 15.5 23 20 25 20 6CWE 0 0 0 ...

  • York LD11556 - page 7

    7 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) PIPING All piping connections are 5/8" OD copper tubing (see Fig.4). The supply and return piping must be adequately sized to meet the design water flow requirements as spec ified for the speci fic insta llatio n . Al l chille d water piping must be insulated to prevent condensation. It is also r ...

  • York LD11556 - page 8

    JOHNSON CONTROLS 8 FORM 1 15.20-NOM6 (1 106) Drain Piping Con dens ate drai n lin es mu st be inst alle d wit h ade quat e slope away from the unit to assure positive drainage. Since the drain pan is located on the suction side of the blower , a negative pressure exists at the drain pan and a minimum trap of 1-1/2" must be provided in the drai ...

  • York LD11556 - page 9

    9 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) SEQUENCE OF OPERA TION YCW With a Chilled W ater Coil The unit will respond to a cooling command from the thermostat by powering a water control valve open. The fan will operate at the speed selected at the thermostat. When the space reaches the temperature setpoint at the thermostat, the cooling valve w ...

  • York LD11556 - page 10

    JOHNSON CONTROLS 10 FORM 1 15.20-NOM6 (1 106) MAINTENANCE MOTOR The blower motor should be cleaned annually and if it has oiling ports, it should be oiled with a good grade of SAE 20 oil. Normally a few drops of oil in each bearing is sufficient. COIL The coil must be kept clean by any of the following methods. 1. Cleaning with low-pressure compre ...

  • York LD11556 - page 11

    1 1 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) This Page Intentionally Left Blank ...

  • York LD11556 - page 12

    T ele. 800-861-1001 www .Y ork.com P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in USA T ele. 800-861-1001 P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in USA T ele. 800-861-1001 Copyright © by Johnson Controls 2006 ALL RIGHTS RESER VED www .Y ork.com C ...

Fabricante York Categoría Air Conditioner

Los documentos del dispositivo York LD11556 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones LD11556
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York LD11556
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York LD11556.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York LD11556, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York LD11556. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York LD11556.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York LD11556, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York LD11556. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York LD11556.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York LD11556 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York LD11556, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York LD11556 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York LD11556 - que deben facilitarnos los primeros pasos durante el uso de York LD11556
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York LD11556
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York LD11556 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York LD11556?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York LD11556, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York LD11556 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)