Carrier 58MEC - page 1
1 58MEC D E L U X E 4 --- W A Y M U L T I P O I S E 2 --- S T A G E CONDENSING GAS F URNACE SIZES 060 TO 120 Service and Maintenance Instructions NOTE : Read the en tire in structio n man ual b efo re starting th e installatio n . T ABLE OF CONTENTS P AGE SAFETY CONSIDERA TI ONS 1 ......................... GENERAL 2 ................................ ...
-
Carrier 58MEC - page 2
2 Installin g and serv icing heatin g eq uip m ent can be h azar dous due to gas a nd el e ct r ic a l c ompone nts . Only t r aine d and qualif ie d se r vic e agenc y per s onnel s hould inst all , r e pair , or ser v ic e heat in g equi pme nt. Unt r aine d per s onnel can per f orm basic maint e nance f unc ti ons de sc ri be d in User’ s Inf ...
-
Carrier 58MEC - page 3
3 1. D iscon n ect all p ow er to the fu rnace. DO N OT TOU CH THE CONTROL OR ANY WIRE CONNECTED TO THE CONTROL PRIOR T O DISCHARGI NG YOUR BODY’S ELECTROST A TIC CHARGE T O GROUND. 2. Fir ml y touch a cl e an, unpa i nte d, me ta l sur f ac e of the fur - nac e cha s si s whic h is clos e to t he contr ol. T ools hel d in a per s on’ s hand du ...
-
Carrier 58MEC - page 4
4 T a ble 1 – Furnac e Ai r Fil te r T able FURNACE CAS IN G WIDTH IN (MM) FIL TER QUAN TITY AN D SIZE * FIL TER TYPE IN (MM) * SID E RETURN { * IN (MM) BO T TOM RETURN * IN (MM) 17 - - - 1/2 (445) (1) 16 x 25 x 3/4 { (406 x 635 x 19) { (1) 16 x 25 x 3/4 (406 x 635 x 19) 3/4 (19 mm) thick washab le 21 (533 ) (1) 16 x 25 x 3/4 (406 x 635 x 19) (1) ...
-
Carrier 58MEC - page 5
5 COLLECT OR BO X TUBE (PINK) COLLECT OR BO X TUBE (GREEN) INDUCER HOUSING (MOLDED) DRAIN TUBE (BEHIND COLLECT OR BO X DRAIN TUBE) COLLECT OR BO X DRAIN TUBE (BLUE) FIELD-INST ALLED F ACT OR Y -SUPPLIED DRAIN TUBE COUPLING (LEFT DRAIN OPTION) FIELD-INST ALLED F ACT OR Y -SUPPLIED DRAIN TUBE FIELD-INST ALLED F ACT OR Y -SUPPLIED 1 ⁄ 2 -IN. CPVC ST ...
-
Carrier 58MEC - page 6
6 UNIT DAMAGE HAZARD Failu re to follo w this cautio n may resu lt in damag e to furn ace. Labe l al l w ir es pri or t o di sc onne ct ion w hen s e rvi ci ng cont rol s. W ir i ng er ror s ca n c aus e impr oper and da nge rous oper at i on. CAUTION ! 5. Rem o ve w ires fro m g as v alve. No te lo catio n for reassem bly. 6. Re move burne r box p ...
-
Carrier 58MEC - page 7
7 21. Ch eck fo r g as leak s. 22. Repl a ce ma i n furna ce door . Step 4 — Cl ean in g H eat Ex ch an gers The foll owi ng it em s s hould be per for me d by a qua li f ie d se rvi c e techn ician . PRIMARY HE AT EXCH ANGE RS If the h eat ex ch ang ers g et an accu mu latio n of lig h t d irt or du st on the ins ide , they m ay be cl e ane d by ...
-
Carrier 58MEC - page 8
8 induc e r as s embl y . See Fl ushi ng Colle ct or Box and Dra ina ge Syst e m s ec ti on f or de t ai ls on re movi ng induc e r a s se mbl y . Step 5 — Flushing Collector Box and Drainage Syst em 1. Tu rn o ff gas and electrical sup plies to fu rnace. 2. Rem ove mai n furna c e door. 3. Dis connec t i nduce r mot or and pre ssur e s wit c h w ...
-
Carrier 58MEC - page 9
9 F urnac e i s sh ipped from fact ory in upfl ow configurati on. Pre ssure tube a nd dr ain t ube r outing MUST match the di agrams bel ow . Tub e loca tion whe n us ed in DO WNF LOW applic ation T ube l ocat i on whe n use d on HORIZONT AL - RIGHT appli catio n PLUG CAP COLLECTOR BOX DRAI N TUBE (BL UE & WHITE STRI PED) COLLECTOR BOX TUBE (PI ...
-
Carrier 58MEC - page 10
10 BURNER FLAME BURNER MANIFOLD A89020 Fig. 1 1 - - Burner Fla me RTV PA M A93081 Fig. 12 - - Gas ket on Coll ec tor Box Step 6 — S ervi cin g Ho t Su rface Ign i ter The igni te r does NOT re quire a nnua l ins pec t ion. Che ck igni te r resistance b efo re remo v al. 1. Tu rn o ff gas and electrical sup plies to fu rnace. 2. Rem ove mai n furn ...
-
Carrier 58MEC - page 11
11 A05075 Fig . 1 3 - - Ig niter B ra ck et 2-5/32˝ (55 mm) A04181 Fig. 14 - - Igni te r Step 7 — E lectri cal Co ntrols an d Wiri ng ELECTRICAL SHOCK HAZARD Fai l ure t o foll ow thi s war ning coul d res ult in per s onal i njur y or dea th. Ther e may be more than 1 e le ctr ic a l s uppl y to t he uni t . Chec k accessories an d co o lin g u ...
-
Carrier 58MEC - page 12
12 115- V FUSED DISCONNECT SWITCH (WHEN REQUIRED) JUNCTION BOX CONTROL BOX 24- V TERMINAL BL OCK TWO- WIRE HEA TING- ONL Y FIVE WIRE 1-ST AGE THERMOST A T TERMINALS FIELD-SUPPLIED FUSED DISCONNECT CONDENSING UNIT FURNACE COM R WY R G C GND GND GND GND GND GND FIELD 24- V WIRING FIELD 115-, 208/230-, 460- V WIRING F ACTORY 24- V WIRING F ACTORY 115- ...
-
Carrier 58MEC - page 13
13 TEST / TWIN HUM PL T SEC-2 SEC-1 COM 24V AC PL1 W2 Y DHUM G COM W/W1 Y/Y2 R 24V FUSE 3-AMP EAC-2 EAC-1 L1 BL -1 PR-1 L2 COM HI H T COOL LO H T SP ARE 2 SPARE 1 24V MTR T APS BLOWER SPEED TERMINALS 1 15-V AC (L2) NEUTRAL CONNECTIONS LED OPERA TION & DIAGNOSTIC LIGHT 3-AMP FUSE 24- V THERMOS T AT TERMINALS SET UP SWITCHES LOW HE A T ONL Y AND ...
-
Carrier 58MEC - page 14
14 A99118 Fig. 19 - - Induce r H ousing Dr ai n T ube Cap Reco rd th e co de an d rep eat th e d isco nn ect an d reco n nect o f th e red wire, record in g each co de un til cod e 1 1 is d isplay ed in d icating no addi t iona l codes . Aft er t he la st c ode is dis playe d or af t er 2 minute s in th e co de recall m od e th e co n trol w ill re ...
-
Carrier 58MEC - page 15
15 SERVICE To initiate the component test sequence, shut OFF the room thermostat or disconnect t he "R" t hermostat lead. Briefly short the TE ST/TWIN te rminal to the "Com 24V" terminal. St atus LED will flash last stat us code and then turn ON the inducer m otor. The inducer mot or will start i n HIGH speed and remain on HIGH ...
-
Carrier 58MEC - page 16
16 A08343 Fig. 22 - - W ir ing Di agram 58MEC ...
-
Carrier 58MEC - page 17
17 Is LED status light on? Is LED status light blinking rapidly without a pause? Is LED status light blinking ON/OFF slowly with a combination of short and l ong flashes? Determine status code. The status code is a 2 digit number with the first digit determined by the number of short flashes and the second digit by the number of long flashes? Go to ...
-
Carrier 58MEC - page 18
18 11 NO PREVIOUS CODE – Stored codes are erased after 72 hour s. On RED LED boards stored status codes can also be erased whenev er power (115V or 24V) is interrupted. Run system through a low-heat, high-heat, or cooling cycle to chec k sys tem. 12 BLOWER ON AFTER PO WER UP – (115V OR 24V) – Normal operation. Blower r uns for the selected b ...
¿Tienes una pregunta acerca de Carrier 58MEC?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Carrier 58MEC, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Carrier 58MEC probablemente compartirá una forma de solucionarlo.