  • Regency P40-NG1 - page 1

    T ested by: FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-661b MODELS: P40-NG1 Natural Gas P40-LP1 Propane P40 Gas Fireplace FOR YOUR SAFETY What to do if you smell gas:  Do not try to light any appliance  Do not touch any electrical switch: do not use any phone in your building.  Immediately ...

  • Regency P40-NG1 - page 2

    Regency ® P40-1 Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The P40 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P40 has been approved by W arnock Hersey for both safety and ef ? ...

  • Regency P40-NG1 - page 3

    Regency ® P40-1 Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS Conversion Kit #502-969 from NG to LP ..................... 27 Conversion Kit #502-966 from LP to NG ..................... 29 Brick Panel Installation ................................................ 31 Aeration Adjustment .................................................... 36 Standa ...

  • Regency P40-NG1 - page 4

    Regency ® P40-1 Direct V ent Gas Fireplace 4 INST ALLA TION INST ALLA TION This is a copy of the label that accompanies each P40-NG1 and P40-LP1 Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . NOTE: Regency ® units are constantly being improved. Check the label on the unit and if there is a difference, th ...

  • Regency P40-NG1 - page 5

    Regency ® P40-1 Direct V ent Gas Fireplace 5 INST ALLA TION INST ALLA TION 5.08: Modifica tions to NFPA-54, Chapter 10 (2) Revise 10.8. 3 by adding the follow ing additiona l requirements: (a) For all side wall hor izontally vente d gas fueled equipm ent installed in every dwellin g, building or struc ture used in whole or in part for residential ...

  • Regency P40-NG1 - page 6

    Regency ® P40-1 Direct V ent Gas Fireplace 6 INST ALLA TION INST ALLA TION 34" (864mm) 40” (1016mm) 8” (203mm) Outer Dia. 5” (127mm) Inner Dia. 40” (1016mm) 35-7/8” (889mm) 35-1/4" (895mm) 20-1/16” (508mm) Dimensions ...

  • Regency P40-NG1 - page 7

    Regency ® P40-1 Direct V ent Gas Fireplace 7 INST ALLA TION INST ALLA TION IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The P40 Direct V ent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a ...

  • Regency P40-NG1 - page 8

    Regency ® P40-1 Direct V ent Gas Fireplace 8 INST ALLA TION INST ALLA TION HEARTH REQUIREMENTS A 40" (1016mm) wide x 16" (406mm) deep x 1-1/2" (38mm) thick hearth is required, unless the unit is raised 4" (102mm). 4) This appliance is Listed for bedroom installations when used with the FireWizard (millivolt thermostat system). ...

  • Regency P40-NG1 - page 9

    Regency ® P40-1 Direct V ent Gas Fireplace 9 INST ALLA TION INST ALLA TION CLEARANCES The clearances listed below are minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent sy ...

  • Regency P40-NG1 - page 10

    Regency ® P40-1 Direct V ent Gas Fireplace 10 INST ALLA TION INST ALLA TION 13” Mantel 8” Mantel 1” Mantel 33” to floor 2 0 12 14 6 4 8 10 17” 21” 2 0 12 6 16 18 20 4 14 8 10 Combustible Material T op Standoff Non-Combustible Header (On Edge) Side View To p Louvers 12” 8-1/2” 10-1/4” To p Nailing Strip Non-Combustible Material Fu ...

  • Regency P40-NG1 - page 11

    Regency ® P40-1 Direct V ent Gas Fireplace 11 INST ALLA TION INST ALLA TION 10-1/4” Above Fireplace 6” 6” Diagram 1 1) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 42-1/2" high x 40-1/2" wide x 20-1/16" deep (1080mm H x 1029mm W x 508mm D), see Diagram 1. Also see Diagr ...

  • Regency P40-NG1 - page 12

    Regency ® P40-1 Direct V ent Gas Fireplace 12 INST ALLA TION INST ALLA TION VENTING INTRODUCTION The P40 uses the "balanced fl ue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heat ...

  • Regency P40-NG1 - page 13

    Regency ® P40-1 Direct V ent Gas Fireplace 13 INST ALLA TION INST ALLA TION EXTERIOR VENT TERMINA TION REQUIREMENTS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *#(min. 12"/30cm) D= V ...

  • Regency P40-NG1 - page 14

    Regency ® P40-1 Direct V ent Gas Fireplace 14 INST ALLA TION INST ALLA TION VENTING ARRANGEMENTS HORIZONT AL TERMINA TION (FLEX) Regency ® Direct V ent System These venting systems, in combination with the P40 Direct V ent Gas Fireplace, have been tested and listed as a direct vent heater system by W arnock Hersey . The location of the terminatio ...

  • Regency P40-NG1 - page 15

    Regency ® P40-1 Direct V ent Gas Fireplace 15 INST ALLA TION INST ALLA TION RIGID PIPE VENTING SYSTEMS BASIC HORIZONT AL & VERTICAL TERMINA TIONS Rigid Pipe V ent Systems of fer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized ? ...

  • Regency P40-NG1 - page 16

    Regency ® P40-1 Direct V ent Gas Fireplace 16 INST ALLA TION INST ALLA TION Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ Metal-Fab ® Sure Seal 6” Pipe Length, Galvanized 58DV A-06 1208 5DT -6 5D6 6” Pipe Length, Black 58DV A-06B 1208B 5DT -6B 5D6B 9” Pipe Length, Galvanized 58DV A-0 ...

  • Regency P40-NG1 - page 17

    Regency ® P40-1 Direct V ent Gas Fireplace 17 INST ALLA TION INST ALLA TION L676 & L900 Direct V ent Fireplace IMPORT ANT NOTE • A V ent Guard is required when the AstroCap is installed above grade at 7 feet or lower . • The Simpson Dura-V ent and Selkirk Direct T emp horizontal termination caps cannot be used in any applications. • Only ...

  • Regency P40-NG1 - page 18

    Regency ® P40-1 Direct V ent Gas Fireplace 18 INST ALLA TION INST ALLA TION The diagram shows all allowable combinations of vertical runs with horizontal terminations, one 90 o elbow (two 45 o elbows equal one 90 o elbow). Note: Must use optional rigid pipe adapter (Part # 770-994) when using any Rigid V ent System (ie. Simpson Dura-V ent pipe). ? ...

  • Regency P40-NG1 - page 19

    Regency ® P40-1 Direct V ent Gas Fireplace 19 INST ALLA TION INST ALLA TION H H1 V Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. One 90 o elbow = T wo 45 o elbows. Option V H + H1 A) 2' Min. 2' Max. B) 3' Min. 5' Max. C) 4' Min. 6' Max. ...

  • Regency P40-NG1 - page 20

    Regency ® P40-1 Direct V ent Gas Fireplace 20 INST ALLA TION INST ALLA TION V H1 H V1 V1 V H V ertical V enting with T wo (2) 90 o Elbows V ertical V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. One 90 o elbow = T wo 45 o elbows. Option V H V + V1 A) 0' Min. 2' Max. 1' Min. B) 1' Min. 4' Max. 2&apos ...

  • Regency P40-NG1 - page 21

    Regency ® P40-1 Direct V ent Gas Fireplace 21 INST ALLA TION INST ALLA TION • V ent must be supported at offsets. • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances" section. • Refer to "V ent Restrictor Position" section ...

  • Regency P40-NG1 - page 22

    Regency ® P40-1 Direct V ent Gas Fireplace 22 INST ALLA TION INST ALLA TION Diagram 7 Diagram 6 10) Install wall thimble in the center of the 1 1" (279mm) square and attach with wood screws (Diagram 7). Diagram 5 7) Insure that the 1-1/4"(32mm) pipe clearances to combustible materials are maintained (Diagram 5). Install the termination c ...

  • Regency P40-NG1 - page 23

    Regency ® P40-1 Direct V ent Gas Fireplace 23 INST ALLA TION INST ALLA TION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation. W all straps are available for thi ...

  • Regency P40-NG1 - page 24

    Regency ® P40-1 Direct V ent Gas Fireplace 24 INST ALLA TION INST ALLA TION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 ...

  • Regency P40-NG1 - page 25

    Regency ® P40-1 Direct V ent Gas Fireplace 25 INST ALLA TION INST ALLA TION P40-NG1 SYSTEM DA T A For 0 to 4500 feet altitude Front Burner Ori fi ce: #44 Back Burner Ori fi ce: #35 Max. Input Rating 45,000 Btu/h Min. Input Rating 13,000 Btu/h Supply Pressure min.5.0" w .c. Manifold Pressure (High) 3.5"+/- 0.3"w .c. Log Set : Ceram ...

  • Regency P40-NG1 - page 26

    Regency ® P40-1 Direct V ent Gas Fireplace 26 INST ALLA TION INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect p ...

  • Regency P40-NG1 - page 27

    Regency ® P40-1 Direct V ent Gas Fireplace 27 INST ALLA TION INST ALLA TION CONVERSION KIT #502-969 FROM NG T O LP LP Conversion Kit Contains: Qty . Part # Description 1 910-462 LP Conversion Coil 1 910-037 LP Pilot Orifi ce 1 904-345 Orifi ce #53 1 904-575 Orifi ce #55 1 904-529 Allen Key 1 918-590 LP Conversion Decal 1 908-528 Red Propane Lab ...

  • Regency P40-NG1 - page 28

    Regency ® P40-1 Direct V ent Gas Fireplace 28 INST ALLA TION INST ALLA TION 14) Re-install pilot shield. 15) Set aeration on both front and rear burner for LP gas; Rear 3/16" Front 3/8" 16) Reverse steps 8 to 4. 17) Remove the Power Module by lifting it up off of the velcro and move it over to the side. Power Module Control Module 18) Re ...

  • Regency P40-NG1 - page 29

    Regency ® P40-1 Direct V ent Gas Fireplace 29 INST ALLA TION INST ALLA TION CONVERSION KIT #502-966 FROM LP TO NG NG Conversion Kit Contains: Qty . Part # Description 1 910-463 NG Conversion Coil 1 910-036 NG Pilot Orifi ce 1 904-644 Orifi ce #35 1 904-568 Orifi ce #44 1 910-249 J9 Jumper 1 904-529 Allen Key 1 908-514 NG Conversion Decal 1 908- ...

  • Regency P40-NG1 - page 30

    Regency ® P40-1 Direct V ent Gas Fireplace 30 INST ALLA TION INST ALLA TION 14) Re-install pilot shield. 15) Set aeration on both front and rear burner for LP gas; Rear 1/4" Front 1/8" 16) Reverse steps 8 to 4. 17) Remove the Power Module by lifting it up off of the velcro and move it over to the side. Power Module Control Module 18) Rem ...

  • Regency P40-NG1 - page 31

    Regency ® P40-1 Direct V ent Gas Fireplace 31 INST ALLA TION INST ALLA TION IMPORT ANT Dangerous operating conditions may occur if the panels are broken. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit. 3) Place the 2 small Back Brick Panels at the base of the fi rebox on the left and right sid ...

  • Regency P40-NG1 - page 32

    Regency ® P40-1 Direct V ent Gas Fireplace 32 INST ALLA TION INST ALLA TION Read the instructions below carefully and refer to the pictures. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. Log kit (Part # 503-930) contains the following pieces: a) 03-32 Back Log b) 03-40 Ember ...

  • Regency P40-NG1 - page 33

    Regency ® P40-1 Direct V ent Gas Fireplace 33 INST ALLA TION INST ALLA TION 11 ) Place log 03-33 on the back burner in between the burner tubes. Slide the log to the left until it touches the end of the burner tube. 03-33 Burner Tu b e 10) Fit log 03-34 into the 1st log stand post and rest on the ember bed. 1st Log Stand Post 03-34 03-40 6) Spread ...

  • Regency P40-NG1 - page 34

    Regency ® P40-1 Direct V ent Gas Fireplace 34 INST ALLA TION INST ALLA TION 12) Place the bottom of log 03-46 onto the 2nd log stand post and fi t the top of log 03-46 into the pin on the left side of log 03-33. 13) Place the end of log 03-36 on the 3rd log stand post and fi t the top of log 03-36 into the pin on the right side of log 03-33. 03- ...

  • Regency P40-NG1 - page 35

    Regency ® P40-1 Direct V ent Gas Fireplace 35 INST ALLA TION INST ALLA TION Completed Log Set Installation 03-37 03-36 03-46 03-34 03-32 03-47 03-40 03-38(1) 03-38(2) 16) Place one of log 03-38 on the exposed base brick on the left side of the unit as shown. 17) Place the second piece of log 03-38 on the exposed base brick on the right side of the ...

  • Regency P40-NG1 - page 36

    Regency ® P40-1 Direct V ent Gas Fireplace 36 INST ALLA TION INST ALLA TION Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR NOTE: Install Finishing T rim prior to installing the Flush Door and Louvers. 1) The standard fl ush door comes with a black frame. T o install the frame, simply hook the top door fl ange onto the top of the unit and swing the doo ...

  • Regency P40-NG1 - page 37

    Regency ® P40-1 Direct V ent Gas Fireplace 37 INST ALLA TION INST ALLA TION WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. A receptacle is provided on the left hand side of the unit. 120 V olt AC power must be wired to the receptacle and the control ...

  • Regency P40-NG1 - page 38

    Regency ® P40-1 Direct V ent Gas Fireplace 38 INST ALLA TION INST ALLA TION Leave these two screws secured Remove the center screw Loosen these four screws Leave these two screws secured Cut Outs Oblong Hole T op Flange Bottom Flange Cut Outs Rear view of Full Screen Door Frame Shown Inside T op of Outer Frame 1) Before beginning the installation; ...

  • Regency P40-NG1 - page 39

    Regency ® P40-1 Direct V ent Gas Fireplace 39 INST ALLA TION INST ALLA TION Upper Air Register Simply push in the Full Screen Door Frame until it aligns against the fi nished wall. Secure T op Flange of Full Screen Door Frame as described in step 4b. For the Bottom Flange of the Full Screen Door Frame, push the bottom of the Frame until it aligns ...

  • Regency P40-NG1 - page 40

    Regency ® P40-1 Direct V ent Gas Fireplace 40 OPERA TION OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the door frame is ...

  • Regency P40-NG1 - page 41

    Regency ® P40-1 Direct V ent Gas Fireplace 41 OPERA TION OPERA TING INSTRUCTIONS During the fi rst few fi res, a white fi lm may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the fi lm will bake on and become very dif fi cult to remove. Use a non-abrasive cleaner and DO ...

  • Regency P40-NG1 - page 42

    Regency ® P40-1 Direct V ent Gas Fireplace 42 OPERA TION OPERA TING INSTRUCTIONS SUMMAR Y OF CONTROLS For the Manual Control Box, located on right hand side of the bottom louver . On/Off Button If the unit is off, pressing and releasing this button once will switch the unit on. The unit will be on high for 20 seconds and then resume to its last se ...

  • Regency P40-NG1 - page 43

    Regency ® P40-1 Direct V ent Gas Fireplace 43 OPERA TION OPERA TING INSTRUCTIONS COPY OF LIGHTING PLA TE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1) Push in gas control knob slightly and turn clockwise to “OFF”. Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in ...

  • Regency P40-NG1 - page 44

    Regency ® P40-1 Direct V ent Gas Fireplace 44 MAINTENANCE MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year . When cleaning the logs, use a soft clean paint brush as the l ...

  • Regency P40-NG1 - page 45

    Regency ® P40-1 Direct V ent Gas Fireplace 45 MAINTENANCE MAINTENANCE CAUTION: Wear gloves when removing damaged or broken glass. W ARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or quali fi ed service person. DOOR GLASS Y our Regency ® fi repla ...

  • Regency P40-NG1 - page 46

    Regency ® P40-1 Direct V ent Gas Fireplace 46 MAINTENANCE MAINTENANCE V AL VE REPLACEMENT 1) Shut off the main gas supply and unplug the power to the ECS system. 2) Remove the main gas line pipe from the gas valve. 3) Remove logs and brick panels if installed. 4) Remove the log stand by undoing the 2 screws, one on the left and right side. 5) Remo ...

  • Regency P40-NG1 - page 47

    Regency ® P40-1 Direct V ent Gas Fireplace 47 MAINTENANCE MAINTENANCE 1) Unplug the power source. 2) Remove the manual control panel by removing the 2 screws. 3) Remove the DC Sparker by removing the 2 screws that secure the DC Sparker to the fi rebox and lift out. DC Sparker 4) Remove the cover on the DC Sparker and unplug the red (+) and black ...

  • Regency P40-NG1 - page 48

    Regency ® P40-1 Direct V ent Gas Fireplace 48 MAINTENANCE MAINTENANCE Power Module 3) Remove the Control Module by lifting it up off of the velcro and pull out. 1) Unplug the power source. 2) Remove the Power Module by lifting it up off of the velcro and pull out. Control Module 4) Remove the Heat Shield from the Control Module by removing the 2 s ...

  • Regency P40-NG1 - page 49

    Regency ® P40-1 Direct V ent Gas Fireplace 49 P AR TS LIST P ARTS LIST MAIN ASSEMBL Y Part # Description 10) 502-528 Brick Panel Base (Set of 3) 502-901 Brick Panel Set Standard Brown 502-902 Brick Panel Set Standard Red 1 1) 502-097 Log Stand 12) 502-033 Front Air Box 13) 948-450 Burner T ube Front NG/LP 14) 948-462 Burner T ube Rear NG/LP 15) 50 ...

  • Regency P40-NG1 - page 50

    Regency ® P40-1 Direct V ent Gas Fireplace 50 P AR TS LIST P ARTS LIST 120 122 121 125 127 128 129 126 V AL VE TRA Y ASSEMBL Y Part # Description 120) 904-644 Ori fi ce # 35 121) 904-568 Ori fi ce # 44 122) 910-008 Pilot Assembly 125) 910-460 V alve NG - SIT 825 126) 910-937 V alve Solenoid - 3 V olt 127) 910-928 Wire Harness Solenoid Switch 128 ...

  • Regency P40-NG1 - page 51

    Regency ® P40-1 Direct V ent Gas Fireplace 51 P AR TS LIST P ARTS LIST FLUSH DOOR & LOUVERS Part # Description 502-910 Flush Louvers (Set) - Black 133) * Flush Louver - T op 134) * Flush Louver - Bottom 135) 940-349/P Glass (Flush) 138) 502-003 Flush Door Frame 139) 936-155 Glass Gasket (T adpole) 140) 948-042 Spring Hinge 502-924 Finishing T ...

  • Regency P40-NG1 - page 52

    Regency ® P40-1 Direct V ent Gas Fireplace 52 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _____________________________________ ...

  • Regency P40-NG1 - page 53

    Regency ® P40-1 Direct V ent Gas Fireplace 53 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _____________________________________ ...

  • Regency P40-NG1 - page 54

    Regency ® P40-1 Direct V ent Gas Fireplace 54 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _____________________________________ ...

  • Regency P40-NG1 - page 55

    Regency ® P40-1 Direct V ent Gas Fireplace 55 W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime wa ...

  • Regency P40-NG1 - page 56

    Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ...

Fabricante Regency Categoría Indoor Fireplace

Los documentos del dispositivo Regency P40-NG1 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Regency
- manuales de instrucciones P40-NG1
- hojas de producto Regency
- folletos informativos
- o etiquetas energéticas Regency P40-NG1
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Regency P40-NG1.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Regency P40-NG1, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Regency P40-NG1. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Regency P40-NG1.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Regency P40-NG1, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Regency P40-NG1. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Regency P40-NG1.

El manual de instrucciones completo de Regency debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Regency P40-NG1 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Regency P40-NG1, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Regency P40-NG1 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Regency P40-NG1 - que deben facilitarnos los primeros pasos durante el uso de Regency P40-NG1
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Regency P40-NG1
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Regency P40-NG1 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Regency P40-NG1?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Regency P40-NG1, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Regency P40-NG1 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen